Lenovo ThinkSystem M.2 Adapters: технические характеристики и документация
Abstract
M.2 is a solid-state drive (SSD) form factor primarily used as an operating system boot solution. Lenovo ThinkSystem servers support M.2 drives either with the addition of a supported M.2 adapter or module, or directly on the system board.
This product guide provides essential presales information to understand the ThinkSystem M.2 adapters, their key features and specifications, components and options, and configuration guidelines. This guide is intended for technical specialists, sales specialists, sales engineers, IT architects, and other IT professionals who want to learn more about the M.2 components, and consider their use in IT solutions.
Change History
Changes in the March 17, 2026 update:
- Added the following hot-swap M.2 adapters for drive bays:
- ThinkSystem SR630 V4 Front M.2 RAID B550d-2HS SATA/NVMe Enablement Kit, 4XH7B11659
- ThinkSystem SR650/a V4 Front M.2 RAID B550d-2HS SATA/NVMe Enablement Kit, 4XH7B11660
- Added the following hot-swap M.2 adapters for PCIe slots:
- ThinkSystem SR630 V4 Rear M.2 RAID B550p-2HS SATA/NVMe Enablement Kit, 4XH7B11658
- ThinkSystem SR650/a V4 Rear M.2 RAID B550p-2HS SATA/NVMe Enablement Kit, 4XH7B11661
- ThinkSystem M.2 RAID B550p-2HS SATA/NVMe Enablement Kit, 4XH7B11701
- Added the following internal M.2 adapters:
- ThinkSystem M.2 B350i-2i NVMe Enablement Kit, 4Y37B09897
- ThinkSystem M.2 RAID B550i-2i SATA/NVMe Enablement Kit, 4Y37B09898
Introduction
M.2 is a solid-state drive (SSD) form factor primarily used as an operating system boot solution in conventional rack and tower servers, or as small form factor storage offering for edge servers.
Lenovo ThinkSystem servers support M.2 drives in one of four ways, depending on the server selected:
- One or two drives, mounted in a hot-swap M.2 adapter, either in a drive bay or in a PCIe slot
- One or two drives, mounted in an M.2 adapter, in a dedicated internal location
- Two or four drives, mounted horizontally in an M.2 adapter
- Installed directly on the system board
One example is the ThinkSystem M.2 RAID B540i-2i SATA/NVMe Adapter, as shown in the following figure, with one M.2 drive installed.

Figure 1. ThinkSystem M.2 RAID B540i-2i SATA/NVMe Adapter
Did you know?
Many of the M.2 adapters include a built-in RAID controller and allows two installed M.2 drives to be configured either as RAID-1, RAID-0, or two independent drives (JBOD mode).
The Dual M.2 Adapter features a Lenovo patented design that provides a tool-less method for attaching back-to-back M.2 modules to the adapter.
Part number information
M.2 adapters for ThinkSystem servers are grouped as follows:
- Part number information - B350/B550 adapters
- Part number information - B340/B545 adapters and earlier
- Part number information - 1st generation adapters
Part number information - B350/B550 adapters
The following table lists the ordering for B350 and B550 M.2 adapters.
Drive support for CTO orders: For configure-to-order in DCSC, the B350 and B550 adapters listed in the table can only be configured with the following drives. Hot-swap enablement components will automatically be derived if a B550p or B550d controller is selected:
- ThinkSystem M.2 VA 480GB Read Intensive NVMe NHS SSD, C286
- ThinkSystem M.2 VA 960GB Read Intensive NVMe NHS SSD, C287
- ThinkSystem M.2 VA 1.92TB Read Intensive NVMe NHS SSD, C288
Drive support for field upgrades: For field upgrades, only the following part numbers are supported:
- Hot-swap drives, for use with B550p/B550d adapters:
- ThinkSystem M.2 VA 480GB Read Intensive NVMe HS SSD, 4XB7B14665
- ThinkSystem M.2 VA 960GB Read Intensive NVMe HS SSD, 4XB7B14666
- ThinkSystem M.2 VA 1.92TB Read Intensive NVMe HS SSD, 4XB7B14667
- Non-hot-swap drives, for use with B350i/B550i adapters (not supported with B550p/B550d adapters):
- ThinkSystem M.2 VA 480GB Read Intensive NVMe NHS SSD, 4XB7A93140
- ThinkSystem M.2 VA 960GB Read Intensive NVMe NHS SSD, 4XB7A93141
- ThinkSystem M.2 VA 1.92TB Read Intensive NVMe NHS SSD, 4XB7A93142
SATA drives are currently not supported.
| Part number | Feature | Description | NVMe | SATA | RAID |
|---|---|---|---|---|---|
| Hot-swap M.2 adapter (install in a drive bay) (server specific) | |||||
| 4XH7B11659 | CD0S | ThinkSystem SR630 V4 Front M.2 RAID B550d-2HS SATA/NVMe Enablement Kit | Yes (x1) | No | Yes (0,1) |
| 4XH7B11660 | CD0S | ThinkSystem SR650/a V4 Front M.2 RAID B550d-2HS SATA/NVMe Enablement Kit | Yes (x1) | No | Yes (0,1) |
| Hot-swap M.2 adapter (install in a PCIe slot) (server specific) | |||||
| 4XH7B11658 | CCCZ | ThinkSystem SR630 V4 Rear M.2 RAID B550p-2HS SATA/NVMe Enablement Kit | Yes (x1) | No | Yes (0,1) |
| 4XH7B11661 | CCCZ | ThinkSystem SR650/a V4 Rear M.2 RAID B550p-2HS SATA/NVMe Enablement Kit | Yes (x1) | No | Yes (0,1) |
| 4XH7B11701 | CCCZ | ThinkSystem M.2 RAID B550p-2HS SATA/NVMe Enablement Kit | Yes (x1) | No | Yes (0,1) |
| Internal M.2 adapters (non-hot-swap) | |||||
| 4Y37B09898 | CC7G | ThinkSystem M.2 RAID B550i-2i SATA/NVMe Enablement Kit | Yes (x1) | No | Yes (0,1) |
| 4Y37B09897 | CC7H | ThinkSystem M.2 B350i-2i NVMe Enablement Kit | Yes (x1) | No | None |
Part number information - B340/B545 adapters and earlier
The following table lists the ordering for the previous generation M.2 adapters with a side-by-side design.
Drive support: The adapters listed in the table below do NOT support the following drives:
- Hot-swap drives:
- ThinkSystem M.2 VA 480GB Read Intensive NVMe HS SSD, 4XB7B14665
- ThinkSystem M.2 VA 960GB Read Intensive NVMe HS SSD, 4XB7B14666
- ThinkSystem M.2 VA 1.92TB Read Intensive NVMe HS SSD, 4XB7B14667
- Non-hot-swap drives:
- ThinkSystem M.2 VA 480GB Read Intensive NVMe NHS SSD, 4XB7A93140
- ThinkSystem M.2 VA 960GB Read Intensive NVMe NHS SSD, 4XB7A93141
- ThinkSystem M.2 VA 1.92TB Read Intensive NVMe NHS SSD, 4XB7A93142
| Part number | Feature | Description | NVMe | SATA | RAID |
|---|---|---|---|---|---|
| Hot-swap M.2 adapter (install in a drive bay) (server specific) | |||||
| 4XH7B04175 | C217 | ThinkSystem SR630 V4 M.2 RAID B540d-2HS SATA/NVMe Enablement Kit | Yes (x1) | Yes | Yes (0,1) Broadcom |
| 4XH7B03857 | C217 | ThinkSystem SR650/a V4 M.2 RAID B540d-2HS SATA/NVMe Enablement Kit | Yes (x1) | Yes | Yes (0,1) Broadcom |
| Hot-swap M.2 adapter (install in a PCIe slot) (server specific) | |||||
| 4XH7A96836 | C0JJ | ThinkSystem SR630 V4 M.2 RAID B540p 2HS SATA/NVMe Kit | Yes (x1) | Yes | Yes (0,1) Broadcom |
| 4XH7B03860 | C0JJ | ThinkSystem SR650/a V4 M.2 RAID B540p-2HS SATA/NVMe Enablement Kit | Yes (x1) | Yes | Yes (0,1) Broadcom |
| 4XH7B08878 | C0JJ | ThinkSystem SR850 V4/SR860 V4 Rear M.2 RAID B540p-2HS SATA/NVMe Enablement Kit | Yes (x1) | Yes | Yes (0,1) Broadcom |
| Assembly kit for drives for use in hot-swap M.2 drive bays (1 kit needed per M.2 drive) | |||||
| 4XH7A96837 | C1LJ + C2RD | ThinkSystem V4 Hot Swap M.2 SATA/NVMe Drive Assembly Kit | - | - | - |
| Internal M.2 adapters (non-hot-swap) | |||||
| 4Y37A93746 | C26V | ThinkSystem M.2 RAID B545i-2i SATA/NVMe Adapter | Yes (x1) | Yes | Yes (0,1) Broadcom |
| 4Y37A90063 | BYFF | ThinkSystem M.2 RAID B540i-2i SATA/NVMe Adapter | Yes (x1) | Yes | Yes (0,1) Broadcom |
| CTO only | BZPA | ThinkEdge SE455 V3 M.2 RAID B540i-2i SATA/NVMe Adapter with Carrier | Yes (x1) | Yes | Yes (0,1) Broadcom |
| 4Y37A09739 | B5XH | ThinkSystem M.2 SATA 2-Bay RAID Adapter | No | Yes | Yes (0,1) Marvell |
| 4Y37A09750 | B8P9 | ThinkSystem M.2 NVMe 2-Bay RAID Adapter | Yes (x1) | No | Yes (0,1) Marvell |
| 4Y37A91802 | C0JK | ThinkSystem M.2 B340i-2i NVMe Enablement Adapter | Yes (x1) | No | None |
| 4Y37A09738 | B5XJ | ThinkSystem M.2 SATA/NVMe 2-Bay Enablement Kit | Yes (x1) | Yes | None |
| 4Y37A79663 | BM8X | ThinkSystem M.2 SATA/x4 NVMe 2-Bay Adapter | Yes (x4) | Yes | None |
| Internal M.2 adapter in a PCIe adapter bracket (non-hot-swap) | |||||
| 4C57A85377 | B5XJ + BMTU | ThinkSystem M.2 SATA/NVMe 2-Bay Enablement Adapter | Yes (x1) | Yes | None |
Part number information - 1st generation adapters
The following table lists the ordering for the 1st generation M.2 adapters with a back-to-back design.
| Part number | Feature | Description | NVMe | SATA | RAID |
|---|---|---|---|---|---|
| Internal M.2 adapters with back-to-back design (non-hot-swap) | |||||
| 7Y37A01092 | AUMU | ThinkSystem M.2 Enablement Kit | No | Yes (1 drive) | No |
| 7Y37A01093 | AUMV | ThinkSystem M.2 with Mirroring Enablement Kit | No | Yes | Yes (0,1) |
| 4M17A60519 | B88P | ThinkSystem SE350 M.2 Mirroring Enablement Kit | No | Yes | Yes (0,1) |
| Internal M.2 4-bay adapters (SE350 only) (non-hot-swap) | |||||
| 4M17A37281 | B6FF | ThinkSystem SE350 M.2 SATA/NVMe 4-bay Data Drive Enablement Kit | Yes (x1) | Yes | None |
| 4M17A37606 | B6FG | ThinkSystem SE350 M.2 SATA 4-Bay Data RAID Mirroring Enablement Kit | No | Yes | Yes (0,1) |
| M.2 thermal kit (some servers) | |||||
| 4XH7A08791 | B31F | ThinkSystem SR650/SR550/SR590 M.2 Thermal Kit | - | - | - |
Implementation
M.2 is primarily used as an operating system boot solution for conventional rack and tower servers. In edge servers, M.2 is also used for data and application storage, however best practices for edge servers is placing the boot/OS on different drives to data/applications. Drive endurance is an important criteria for both OS and data drives, so care should be taken to select the M.2 drives that match the intended workload. Review the endurance values for the drives you plan to use and ensure they meet the requirements for the OS and applications you plan to run.
Tip: The M.2 adapters and modules are also referred to as enablement kits. In the product publications, they are referred to as M.2 backplanes. These terms are interchangeable.
Implementation of M.2 in ThinkSystem servers is in several ways, as described in the following subsections:
- Hot-swap M.2
- Integrated on the system board
- M.2 adapter with side-by-side drives
- M.2 adapter with back-to-back drives
- M.2 adapter in a PCIe slot
- SE350 data drive implementation
Hot-swap M.2
Starting with ThinkSystem V4, some servers support hot-swap M.2 drives, installed front or rear of the server, for installation in drive bays or in a PCIe slot. The following figure shows the SR650 V4 with front and rear hot-swap M.2 drive bays.

Figure 2. Hot-swap M.2 drive bays
Hot-swap M.2 drive bays require hot-swap M.2 drives. For configure-to-order builds, the hot-swap drive assembly is automatically included in the order for all M.2 drives.
For field upgrades, implementation is as follows:
- For B550 hot-swap M.2 adapters, only specific hot-swap M.2 drives are supported as listed in the Part number information section.
- For B540 hot-swap M.2 adapters, non-hot-swap drives need to be ordered along with a separate kit for each drive, ThinkSystem V4 Hot Swap M.2 SATA/NVMe Drive Assembly Kit (4XH7A96837). The Drive Assembly Kit contains the following components, as shown in the figure below:
- M.2 heatsink
- M.2 drive tray
- M.2 adapter

Figure 3. Components of the ThinkSystem V4 Hot Swap M.2 SATA/NVMe Drive Assembly Kit
Integrated on the system board
On the ST50 V2, ST250 and SR250, a single M.2 drive is installed directly on the system board.
On the ST45 V3, SD530 V3 and SD550 V3, two M.2 drives are installed directly on the system board.
On the SD650 V3, SD650-I V3, SD650-N V3, SD665 V3, and SD665-N V3, a single M.2 drive is installed directly on a cold plate mounted on CPU 1
M.2 adapter with side-by-side drives
Starting with ThinkSystem V2 servers, an M.2 module is mounted horizontally and is cabled to the system board. See the Part number information section for the available adapters.
The following figure shows the B540i SATA/NVMe M.2 adapter with a single 960GB 2280 M.2 drive installed.

Figure 4. SATA/NVMe M.2 Module with 2 drives
M.2 adapter with back-to-back drives
On servers with 1st Gen and 2nd Gen Intel Xeon Scalable processors, and on the SE350, the M.2 drives install into an M.2 adapter which in turn is installed in a dedicated slot in the server. With two M.2 drives configured, the drives are configured by default as a RAID-1 mirrored pair for redundancy. There are two M.2 adapters supported:
- Single M.2 Adapter, which supports one M.2 drive; available as the ThinkSystem M.2 Enablement Kit
- Dual M.2 Adapter, which supports one or two M.2 drives; available as the ThinkSystem M.2 with Mirroring Enablement Kit. Includes a built-in RAID controller and allows two installed M.2 drives to be configured either as RAID-1, RAID-0, or two independent drives (JBOD mode).
The Dual M.2 Adapter, as shown in the following figure, with one 128GB M.2 drive partially inserted. The second M.2 drive is installed on the other side of the adapter.

Figure 5. Dual M.2 Adapter and a 128 GB M.2 drive
The Single M.2 Adapter is shown in the following photo, with the 32GB M.2 drive installed.

Figure 6. Single M.2 Adapter and a 32 GB M.2 drive
M.2 adapter in a PCIe slot
On the ST50 V3, ST250 V3, SR250 V3, and the previous generation SR250 V2 and ST250 V2, the M.2 side-by-side module is mounted in a bracket that is installed in a PCIe slot.

Figure 7. M.2 adapter installed in a PCIe slot
The M.2 module offered is:
- ThinkSystem M.2 SATA/NVMe 2-Bay Enablement Adapter, 4C57A85377, which is a combination of the ThinkSystem M.2 SATA/NVMe 2-Bay Enablement Kit (feature B5XJ) and a Dummy PCIe Card bracket (feature BMTU)
SE350 data drive implementation
On the ThinkSystem SE350 edge server, additional M.2 data drives are mounted on a 4-drive adapter that plugs into the PCIe riser.
There are two M.2 modules offered:
- ThinkSystem SE350 M.2 SATA/NVMe 4-bay Data Drive Enablement Kit, which supports four SATA or four NVMe M.2 drives without RAID support
- ThinkSystem SE350 M.2 SATA 4-Bay Data RAID Mirroring Enablement Kit, which supports four SATA drives and supports RAID 0/1 functionality
The following figure shows the ThinkSystem SE350 M.2 SATA/NVMe 4-bay Data Drive Enablement Kit installed in the PCIe riser.

Figure 8. ThinkSystem SE350 M.2 SATA/NVMe 4-bay Data Drive Enablement Kit
Features
Common features of the all ThinkSystem M.2 solution offerings:
- Hardened boot media that does not use a drive bay
- Support for Power Loss Protection (PLP)
- Tool-less design providing a simple install in limited space
- M.2 SSDs have higher endurance and higher mean time between failures (MTBF) than USB keys
- When using configure-to-order (CTO), you can also select zero drives and add drives as a field upgrade
Tip: 2242, 2260, 2280 and 22110 are the industry terms for the M.2 drive dimensions. For example, 2280 corresponds to a drive that is 22mm wide and 80mm long.
M.2 hot-swap adapters
The B550p-2HS (4XH7B11658, 4XH7B11661, 4XH7B11701, feature CCCZ) and B550d-2HS (4XH7B11659, 4XH7B11660, feature CD0S) all have the following features:
- Supports one or two M.2 drives, either SATA or NVMe
- Each drive is installed in a hot-swap carrier
- Support M.2 2280 (80mm) drive form factor only
- RAID support via an onboard Broadcom SAS3808N RAID Controller
- With 1 drive, supports JBOD
- With 2 drives, supports 2-drive RAID-0, 2-drive RAID-1, or JBOD
- PCIe 4.0 x2 host interface; PCIe 4.0 x1 connection to each drive
- Management and configuration support via UEFI and OS-based tools
- Supports monitoring and reporting of events and temperature
- Firmware update via Lenovo firmware update tools
- Supports SED drive encryption
The B540p-2HS (4XH7B03860, 4XH7B03860, 4XH7B08878, feature C0JJ) and B540d-2HS (4XH7B04175, 4XH7B03857, feature C217) all have the following features:
- Supports one or two M.2 drives, either SATA or NVMe
- Each drive is installed in a hot-swap carrier
- Support M.2 2280 (80mm) drive form factor only
- RAID support via an onboard Broadcom SAS3808N RAID Controller
- With 1 drive, supports JBOD
- With 2 drives, supports 2-drive RAID-0, 2-drive RAID-1, or JBOD
- PCIe 4.0 x2 host interface; PCIe 4.0 x1 connection to each drive
- Management and configuration support via UEFI and OS-based tools
- Supports monitoring and reporting of events and temperature
- Firmware update via Lenovo firmware update tools
- Supports SED drive encryption
Tip: The part numbers are system-unique because they include cables and mounting components that are unique to that server. The functions of the adapters remains the same.
M.2 internal adapters with side-by-side design
The ThinkSystem M.2 RAID B550i-2i SATA/NVMe Enablement Kit (4Y37B09898) has the following features:
- Supports one or two M.2 drives, either SATA or NVMe
- Drives are not hot-swap
- Support 42mm, 60mm and 80mm drive form factors (2242, 2260 and 2280)
- RAID support via an onboard Broadcom SAS3808N RAID Controller
- With 1 drive, supports JBOD
- With 2 drives, supports 2-drive RAID-0, 2-drive RAID-1, or JBOD (default is RAID-1)
- PCIe 4.0 x2 host interface; PCIe 4.0 x1 connection to each drive
- Management and configuration support via UEFI and OS-based tools
- Supports monitoring and reporting of events and temperature
- Firmware update via Lenovo firmware update tools
- Supports SED drive encryption
The ThinkSystem M.2 RAID B545i-2i SATA/NVMe Adapter (4Y37A93746) has the following features:
- Supports one or two M.2 drives, either SATA or NVMe
- Drives are not hot-swap
- Support 42mm, 60mm and 80mm drive form factors (2242, 2260 and 2280)
- RAID support via an onboard Broadcom SAS3808N RAID Controller
- With 1 drive, supports JBOD
- With 2 drives, supports 2-drive RAID-0, 2-drive RAID-1, or JBOD (default is RAID-1)
- PCIe 4.0 x2 host interface; PCIe 4.0 x1 connection to each drive
- Management and configuration support via UEFI and OS-based tools
- Supports monitoring and reporting of events and temperature
- Firmware update via Lenovo firmware update tools
- Supports SED drive encryption
The ThinkSystem M.2 RAID B540i-2i SATA/NVMe Adapter (4Y37A90063) has the following features:
- Supports one or two M.2 drives, either SATA or NVMe
- Drives are not hot-swap
- Support 42mm, 60mm, 80mm and 110mm drive form factors (2242, 2260, 2280 and 22110)
- RAID support via an onboard Broadcom SAS3808N RAID Controller
- With 1 drive, supports JBOD
- With 2 drives, supports 2-drive RAID-0, 2-drive RAID-1, or JBOD
- PCIe 4.0 x2 host interface; PCIe 4.0 x1 connection to each drive
- Management and configuration support via UEFI and OS-based tools
- Supports monitoring and reporting of events and temperature
- Firmware update via Lenovo firmware update tools
- Supports SED drive encryption
The ThinkSystem M.2 SATA 2-Bay RAID Adapter (4Y37A09739) has the following features:
- Supports one or two SATA M.2 drives
- Drives are not hot-swap
- Support 42mm, 60mm, 80mm and 110mm drive form factors (2242, 2260, 2280 and 22110)
- RAID support via an onboard Marvell 88SE9230 SATA RAID Controller
- Support JBOD, RAID-0 and RAID-1 (RAID support requires two M.2 drives)
- PCIe 2.0 x2 host interface; 6Gbps SATA connection to the drives
- Management and configuration support via UEFI and OS-based tools
- Supports monitoring and reporting of events and temperature through I2C
- Firmware update via Lenovo firmware update tools
- No support for SED drive encryption
The ThinkSystem M.2 NVMe 2-Bay RAID Adapter (4Y37A09750) has the following features:
- Supports one or two NVMe M.2 drives
- Drives are not hot-swap
- Support 42mm, 60mm, 80mm and 110mm drive form factors (2242, 2260, 2280 and 22110)
- RAID support via an onboard Marvell 88NR2241 NVMe RAID Controller
- With 1 drive, supports single-drive RAID-0
- With 2 drives, supports 2-drive RAID-0, 2-drive RAID-1, or two single-drive RAID-0 arrays
- PCIe 3.0 x2 host interface; PCIe 3.0 x1 connection to each drive
- Management and configuration support via UEFI and OS-based tools
- Supports monitoring and reporting of events and temperature through I2C
- Firmware update via Lenovo firmware update tools
- No support for SED drive encryption
The ThinkSystem M.2 B350i-2i NVMe Enablement Kit (4Y37B09897) has the following features:
- Supports one or two NVMe M.2 drives (SATA not supported)
- Drives are not hot-swap
- Support M.2 2280 (80mm) drive form factor only
- No built-in RAID support (optionally supports Intel VROC NVMe RAID)
- PCIe 4.0 x4 host interface; PCIe 4.0 x2 connection to each drive
- Management and configuration support via UEFI and OS-based tools
- Supports monitoring and reporting of events and temperature
- Firmware update via Lenovo firmware update tools
- Supports SED drive encryption
The ThinkSystem M.2 B340i-2i NVMe Enablement Adapter (4Y37A91802) has the following features:
- Supports one or two NVMe M.2 drives (SATA not supported)
- Drives are not hot-swap
- Support M.2 2280 (80mm) drive form factor only
- No built-in RAID support (optionally supports Intel VROC NVMe RAID)
- PCIe 4.0 x4 host interface; PCIe 4.0 x2 connection to each drive
- Management and configuration support via UEFI and OS-based tools
- Supports monitoring and reporting of events and temperature
- Firmware update via Lenovo firmware update tools
- Supports SED drive encryption
The ThinkSystem M.2 SATA/NVMe 2-Bay Enablement Kit (4Y37A09738) and ThinkSystem M.2 SATA/NVMe 2-Bay Enablement Adapter (4C57A85377) have the following features:
- Supports one or two M.2 drives, either SATA or NVMe
- Drives are not hot-swap
- When two drives installed, they must be either both SATA or both NVMe
- Support 42mm, 60mm, 80mm and 110mm drive form factors (2242, 2260, 2280 and 22110)
- No integrated RAID support; RAID supported by VROC (Intel servers only) or by a separate PCIe adapter
- Either 6Gbps SATA or PCIe 3.0 x1 interface to the drives depending on the drives installed
- Supports monitoring and reporting of events and temperature through I2C
- Firmware update via Lenovo firmware update tools
- When connected to a separate PCIe RAID adapter, supports SED drive encryption via the RAID adapter, otherwise no SED support
The ThinkSystem M.2 SATA/x4 NVMe 2-Bay Adapter (4Y37A79663) has the following features:
- Supports one or two M.2 drives, either SATA or NVMe
- Drives are not hot-swap
- When two drives installed, they must be either both SATA or both NVMe
- Support 42mm, 60mm, 80mm and 110mm drive form factors (2242, 2260, 2280 and 22110)
- No integrated RAID support; RAID supported by VROC (Intel servers only) or by a separate PCIe adapter
- Either 6Gbps SATA or PCIe 4.0 x4 interface to the drives depending on the drives installed
- Supports monitoring and reporting of events and temperature through I2C
- Firmware update via Lenovo firmware update tools
- When connected to a separate PCIe RAID adapter, supports SED drive encryption via the RAID adapter, otherwise no SED support
M.2 internal adapters with back-to-back design
Features of the ThinkSystem M.2 with Mirroring Enablement Kit (7Y37A01093) and ThinkSystem SE350 M.2 Mirroring Enablement Kit (4M17A60519):
- PCIe 2.0 x2 host interface (connects to the PCH)
- Based on the Marvell 88SE9230 6 Gbps SATA controller
- Supports one or two 6 Gbps SATA M.2 drives
- Support 42mm, 60mm and 80mm drive form factors (2242, 2260 and 2280 respectively)
- RAID functionality provided by the M.2 adapter
- RAID 1 by default; also supports RAID 0 and JBOD
- UEFI-based settings to enable/disable RAID mode and to review inventory
- Supports Secure Boot
- Adapter and drive firmware update using Lenovo firmware tools
- Management via I2C interface
- 7Y37A01093: No SED support
- 4M17A60519: Supports SED drive encryption
Features of the ThinkSystem M.2 Enablement Kit (7Y37A01092):
- 6 Gbps SATA host interface (connects to the PCH)
- Supports one 6 Gbps SATA M.2 drive
- Support 42mm, 60mm and 80mm drive form factors (2242, 2260 and 2280 respectively)
- Drive firmware update using Lenovo firmware tools
- Management via I2C interface
- VPD reporting of adapter inventory
- No support for SED drive encryption
SE350 4-bay M.2 adapters
The ThinkSystem SE350 M.2 SATA/NVMe 4-bay Data Drive Enablement Kit (4M17A37281) has the following features:
- Supports four SATA or four NVMe M.2 drives (no mixing of drive types)
- Support 42mm, 60mm, 80mm and 110mm drive form factors (2242, 2260, 2280 and 22110 respectively)
- For SATA drives, RAID 0, 1, 5, 10, provided by the PCH controller in the processor
- For NVMe, JBOD support only; no RAID support
- SED drive support
- Either 6Gbps SATA or PCIe 3.0 x1 interface to the drives depending on the drives installed
- Supports SED drive encryption
The ThinkSystem SE350 M.2 SATA 4-Bay Data RAID Mirroring Enablement Kit (4M17A37606) has the following features:
- Supports four SATA M.2 drives (NVMe drives not supported)
- Support 42mm, 60mm, 80mm and 110mm drive form factors (2242, 2260, 2280 and 22110 respectively)
- RAID support via two independent Marvell 88SE9230 6 Gbps SATA controllers
- Each controller connects to two M.2 drives, offering RAID-0 or RAID-1
- Also supports one M.2 drive in a non-RAID (JBOD) configuration
- Supports SED drive encryption
M.2 drives
For the technical specifications of all M.2 drives, as well as server support, see the ThinkSystem SSD Portfolio:
https://lenovopress.com/lp1261-lenovo-thinksystem-ssd-portfolio#term=%2522M.2%2522&availability=Available
Drive compatibility: The B550 and B350 adapters are only supported with a small subset of drives as stated in the Part number information section.
Performance data of NVMe drives: The performance numbers for NVMe drives are based on a PCIe x4 connection to the processor, however, when installed in some M.2 adapters, the NVMe drives only have a x2 or x1 connection. As a result, this performance data should only be used for comparative purposes.
Server support
The following tables list the ThinkSystem servers that are compatible.
| Part Number | Description | AMD V3 | 2S Intel V3/V4 | 1S V3 | 4S 8S Intel V3/V4 | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
SR635 V3 (7D9H / 7D9G) |
SR655 V3 (7D9F / 7D9E) |
SR645 V3 (7D9D / 7D9C) |
SR665 V3 (7D9B / 7D9A) |
SD535 V3 (7DD8 / 7DD1) |
ST650 V3 (7D7B / 7D7A) |
SR630 V3 (7D72 / 7D73) |
SR650 V3 (7D75 / 7D76) |
SR630 V4 (7DG8 / 7DG9) |
SR650 V4 (7DGC / 7DGD) |
SR650a V4 (7DGC / 7DGD) |
ST45 V3 (7DH4 / 7DH5) |
ST50 V3 (7DF4 / 7DF3) |
ST250 V3 (7DCF / 7DCE) |
SR250 V3 (7DCM / 7DCL) |
SR850 V3 (7D97 / 7D96) |
SR860 V3 (7D94 / 7D93) |
SR950 V3 (7DC5 / 7DC4) |
SR850 V4 (7DJT / 7DJS) |
SR860 V4 (7DJQ / 7DJN) |
||
| Hot-swap M.2 adapter (install in a drive bay) | |||||||||||||||||||||
| CD0S | ThinkSystem M.2 RAID B550d-2HS SATA/NVMe Enablement Kit - Controller Board | N | N | N | N | N | N | N | N | Y | Y | Y | N | N | N | N | N | N | N | N | N |
| C217 | ThinkSystem M.2 RAID B540d-2HS SATA/NVMe Enablement Kit - Controller Board | N | N | N | N | N | N | N | N | Y | Y | Y | N | N | N | N | N | N | N | N | N |
| Hot-swap M.2 adapter (install in a PCIe slot) | |||||||||||||||||||||
| CCCZ | ThinkSystem M.2 RAID B550p-2HS SATA/NVMe Enablement Kit | N | N | N | N | N | N | N | N | Y | Y | Y | N | N | N | N | N | N | N | Y | Y |
| C0JJ | ThinkSystem M.2 RAID B540p-2HS SATA/NVMe Adapter | N | N | N | N | N | N | N | N | Y | Y | Y | N | N | N | N | N | N | N | Y | Y |
| M.2 adapters internal adapters | |||||||||||||||||||||
| 4Y37B09898 | ThinkSystem M.2 RAID B550i-2i SATA/NVMe Enablement Kit | N | N | N | N | N | N | N | N | Y | Y | Y | N | N | N | N | N | N | N | Y | Y |
| 4Y37A93746 | ThinkSystem M.2 RAID B545i-2i SATA/NVMe Adapter | N | N | N | N | N | N | N | N | Y | Y | Y | N | N | N | N | N | N | N | Y | Y |
| 4Y37B09897 | ThinkSystem M.2 B350i-2i NVMe Enablement Kit | N | N | N | N | N | N | N | N | Y | Y | Y | N | N | N | N | N | N | N | Y | Y |
| 4Y37A90063 | ThinkSystem M.2 RAID B540i-2i SATA/NVMe Adapter | Y | Y | Y | Y | Y | Y | Y | Y | N | N | N | N | N | Y | Y | Y | Y | N | N | N |
| BZPA | ThinkEdge SE455 V3 M.2 RAID B540i-2i SATA/NVMe Adapter with Carrier | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
| 4Y37A09739 | ThinkSystem M.2 SATA 2-Bay RAID Adapter | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
| 4Y37A09750 | ThinkSystem M.2 NVMe 2-Bay RAID Adapter | Y | Y | Y | Y | N | Y | Y | Y | N | N | N | N | N | N | N | Y | Y | Y | N | N |
| 4Y37A09738 | ThinkSystem M.2 SATA/NVMe 2-Bay Enablement Kit | Y | Y | Y | N | N | Y | N | N | N | N | N | N | N | N | N | Y | Y | N | N | N |
| 4Y37A79663 | ThinkSystem M.2 SATA/x4 NVMe 2-Bay Adapter | Y | Y | Y | Y | N | N | Y | Y | N | N | N | N | Y | Y | Y | Y | Y | N | N | N |
| M.2 side-by-side adapter in a PCIe adapter bracket | |||||||||||||||||||||
| 4C57A85377 | ThinkSystem M.2 SATA/NVMe 2-Bay Enablement Adapter | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
| M.2 adapters with back-to-back design | |||||||||||||||||||||
| 7Y37A01092 | ThinkSystem M.2 Enablement Kit | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
| 7Y37A01093 | ThinkSystem M.2 with Mirroring Enablement Kit | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
| 4M17A60519 | ThinkSystem SE350 M.2 Mirroring Enablement Kit | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
| M.2 4-bay adapters (SE350 only) | |||||||||||||||||||||
| 4M17A37281 | ThinkSystem SE350 M.2 SATA/NVMe 4-bay Data Drive Enablement Kit | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
| 4M17A37606 | ThinkSystem SE350 M.2 SATA 4-Bay Data RAID Mirroring Enablement Kit | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
| M.2 thermal kit (some servers) | |||||||||||||||||||||
| 4XH7A08791 | ThinkSystem SR650/SR550/SR590 M.2 Thermal Kit | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
| Part Number | Description | AI Servers | Edge | Super computing | |||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
SR675 V3 (7D9Q / 7D9R) |
SR680a V3 B200 (7DM9) |
SR685a V3 (7DHC) |
SR780a V3 (7DJ5) |
SR680a V4 (7DMK) |
SE100 (7DGR) |
SE455 V3 (7DBY) |
SC750 V4 (7DDJ) |
SC777 V4 (7DKA) |
SD665 V3 (7D9P) |
||
| Hot-swap M.2 adapter (install in a drive bay) | |||||||||||
| CD0S | ThinkSystem M.2 RAID B550d-2HS SATA/NVMe Enablement Kit - Controller Board | N | N | N | N | N | N | N | N | N | N |
| C217 | ThinkSystem M.2 RAID B540d-2HS SATA/NVMe Enablement Kit - Controller Board | N | N | N | N | N | N | N | N | N | N |
| Hot-swap M.2 adapter (install in a PCIe slot) | |||||||||||
| CCCZ | ThinkSystem M.2 RAID B550p-2HS SATA/NVMe Enablement Kit | N | N | N | N | Y | N | N | N | N | N |
| C0JJ | ThinkSystem M.2 RAID B540p-2HS SATA/NVMe Adapter | N | N | N | N | Y | N | N | N | N | N |
| M.2 adapters internal adapters | |||||||||||
| 4Y37B09898 | ThinkSystem M.2 RAID B550i-2i SATA/NVMe Enablement Kit | N | N | N | N | N | N | N | N | N | N |
| 4Y37A93746 | ThinkSystem M.2 RAID B545i-2i SATA/NVMe Adapter | N | N | N | N | N | N | N | N | N | N |
| 4Y37B09897 | ThinkSystem M.2 B350i-2i NVMe Enablement Kit | N | N | N | N | N | N | N | N | N | N |
| 4Y37A90063 | ThinkSystem M.2 RAID B540i-2i SATA/NVMe Adapter | N | N | N | N | N | N | Y | N | N | N |
| BZPA | ThinkEdge SE455 V3 M.2 RAID B540i-2i SATA/NVMe Adapter with Carrier | N | N | N | N | N | N | Y | N | N | N |
| 4Y37A09739 | ThinkSystem M.2 SATA 2-Bay RAID Adapter | N | N | N | N | N | N | N | N | N | N |
| 4Y37A09750 | ThinkSystem M.2 NVMe 2-Bay RAID Adapter | Y | N | Y | N | N | N | N | N | N | N |
| 4Y37A09738 | ThinkSystem M.2 SATA/NVMe 2-Bay Enablement Kit | Y | N | N | N | N | N | N | N | N | N |
| 4Y37A79663 | ThinkSystem M.2 SATA/x4 NVMe 2-Bay Adapter | Y | N | N | N | N | N | N | N | N | N |
| M.2 side-by-side adapter in a PCIe adapter bracket | |||||||||||
| 4C57A85377 | ThinkSystem M.2 SATA/NVMe 2-Bay Enablement Adapter | N | N | N | N | N | N | N | N | N | N |
| M.2 adapters with back-to-back design | |||||||||||
| 7Y37A01092 | ThinkSystem M.2 Enablement Kit | N | N | N | N | N | N | N | N | N | N |
| 7Y37A01093 | ThinkSystem M.2 with Mirroring Enablement Kit | N | N | N | N | N | N | N | N | N | N |
| 4M17A60519 | ThinkSystem SE350 M.2 Mirroring Enablement Kit | N | N | N | N | N | N | N | N | N | N |
| M.2 4-bay adapters (SE350 only) | |||||||||||
| 4M17A37281 | ThinkSystem SE350 M.2 SATA/NVMe 4-bay Data Drive Enablement Kit | N | N | N | N | N | N | N | N | N | N |
| 4M17A37606 | ThinkSystem SE350 M.2 SATA 4-Bay Data RAID Mirroring Enablement Kit | N | N | N | N | N | N | N | N | N | N |
| M.2 thermal kit (some servers) | |||||||||||
| 4XH7A08791 | ThinkSystem SR650/SR550/SR590 M.2 Thermal Kit | N | N | N | N | N | N | N | N | N | N |
| Part Number | Description | Edge | 1S Intel V2 | 2S Intel V2 | AMD V1 | Multi node | AI | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
SE350 (7Z46 / 7D1X) |
SE350 V2 (7DA9) |
SE360 V2 (7DAM) |
SE450 (7D8T) |
ST50 V2 (7D8K / 7D8J) |
ST250 V2 (7D8G / 7D8F) |
SR250 V2 (7D7R / 7D7Q) |
ST650 V2 (7Z75 / 7Z74) |
SR630 V2 (7Z70 / 7Z71) |
SR650 V2 (7Z72 / 7Z73) |
SR635 (7Y98 / 7Y99) |
SR655 (7Y00 / 7Z01) |
SR645 (7D2Y / 7D2X) |
SR665 (7D2W / 7D2V) |
SD530 V3 (7DDA / 7DD3) |
SD550 V3 (7DD9 / 7DD2) |
SR670 V2 (7Z22 / 7Z23) |
SR680a V3 (7DHE) |
||
| Hot-swap M.2 adapter (install in a drive bay) | |||||||||||||||||||
| CD0S | ThinkSystem M.2 RAID B550d-2HS SATA/NVMe Enablement Kit - Controller Board | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
| C217 | ThinkSystem M.2 RAID B540d-2HS SATA/NVMe Enablement Kit - Controller Board | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
| Hot-swap M.2 adapter (install in a PCIe slot) | |||||||||||||||||||
| CCCZ | ThinkSystem M.2 RAID B550p-2HS SATA/NVMe Enablement Kit | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
| C0JJ | ThinkSystem M.2 RAID B540p-2HS SATA/NVMe Adapter | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
| M.2 adapters internal adapters | |||||||||||||||||||
| 4Y37B09898 | ThinkSystem M.2 RAID B550i-2i SATA/NVMe Enablement Kit | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
| 4Y37A93746 | ThinkSystem M.2 RAID B545i-2i SATA/NVMe Adapter | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
| 4Y37B09897 | ThinkSystem M.2 B350i-2i NVMe Enablement Kit | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
| 4Y37A90063 | ThinkSystem M.2 RAID B540i-2i SATA/NVMe Adapter | N | N | N | Y | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
| BZPA | ThinkEdge SE455 V3 M.2 RAID B540i-2i SATA/NVMe Adapter with Carrier | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
| 4Y37A09739 | ThinkSystem M.2 SATA 2-Bay RAID Adapter | N | N | N | N | N | N | N | Y | Y | Y | Y | Y | Y | Y | N | N | Y | N |
| 4Y37A09750 | ThinkSystem M.2 NVMe 2-Bay RAID Adapter | N | N | N | N | N | N | N | Y | Y | Y | N | N | Y | Y | N | N | Y | N |
| 4Y37A09738 | ThinkSystem M.2 SATA/NVMe 2-Bay Enablement Kit | N | N | N | Y | N | N | N | Y | Y | Y | Y | Y | Y | Y | N | N | Y | N |
| 4Y37A79663 | ThinkSystem M.2 SATA/x4 NVMe 2-Bay Adapter | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
| M.2 side-by-side adapter in a PCIe adapter bracket | |||||||||||||||||||
| 4C57A85377 | ThinkSystem M.2 SATA/NVMe 2-Bay Enablement Adapter | N | N | N | N | N | Y | Y | N | N | N | N | N | N | N | N | N | N | N |
| M.2 adapters with back-to-back design | |||||||||||||||||||
| 7Y37A01092 | ThinkSystem M.2 Enablement Kit | Y | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
| 7Y37A01093 | ThinkSystem M.2 with Mirroring Enablement Kit | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
| 4M17A60519 | ThinkSystem SE350 M.2 Mirroring Enablement Kit | Y | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
| M.2 4-bay adapters (SE350 only) | |||||||||||||||||||
| 4M17A37281 | ThinkSystem SE350 M.2 SATA/NVMe 4-bay Data Drive Enablement Kit | Y | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
| 4M17A37606 | ThinkSystem SE350 M.2 SATA 4-Bay Data RAID Mirroring Enablement Kit | Y | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
| M.2 thermal kit (some servers) | |||||||||||||||||||
| 4XH7A08791 | ThinkSystem SR650/SR550/SR590 M.2 Thermal Kit | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
| Part Number | Description | SC | Dense V2 | 4S V2 | 8S | 4S V1 | 1S Intel V1 | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
SD665-N V3 (7DAZ) |
SD650 V3 (7D7M) |
SD650-I V3 (7D7L) |
SD650-N V3 (7D7N) |
SD630 V2 (7D1K) |
SD650 V2 (7D1M) |
SD650-N V2 (7D1N) |
SN550 V2 (7Z69) |
SR850 V2 (7D31 / 7D32) |
SR860 V2 (7Z59 / 7Z60) |
SR950 (7X11 / 7X12) |
SR850 (7X18 / 7X19) |
SR850P (7D2F / 2D2G) |
SR860 (7X69 / 7X70) |
ST50 (7Y48 / 7Y50) |
ST250 (7Y45 / 7Y46) |
SR150 (7Y54) |
SR250 (7Y52 / 7Y51) |
||
| Hot-swap M.2 adapter (install in a drive bay) | |||||||||||||||||||
| CD0S | ThinkSystem M.2 RAID B550d-2HS SATA/NVMe Enablement Kit - Controller Board | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
| C217 | ThinkSystem M.2 RAID B540d-2HS SATA/NVMe Enablement Kit - Controller Board | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
| Hot-swap M.2 adapter (install in a PCIe slot) | |||||||||||||||||||
| CCCZ | ThinkSystem M.2 RAID B550p-2HS SATA/NVMe Enablement Kit | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
| C0JJ | ThinkSystem M.2 RAID B540p-2HS SATA/NVMe Adapter | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
| M.2 adapters internal adapters | |||||||||||||||||||
| 4Y37B09898 | ThinkSystem M.2 RAID B550i-2i SATA/NVMe Enablement Kit | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
| 4Y37A93746 | ThinkSystem M.2 RAID B545i-2i SATA/NVMe Adapter | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
| 4Y37B09897 | ThinkSystem M.2 B350i-2i NVMe Enablement Kit | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
| 4Y37A90063 | ThinkSystem M.2 RAID B540i-2i SATA/NVMe Adapter | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
| BZPA | ThinkEdge SE455 V3 M.2 RAID B540i-2i SATA/NVMe Adapter with Carrier | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
| 4Y37A09739 | ThinkSystem M.2 SATA 2-Bay RAID Adapter | N | N | N | N | N | N | N | Y | N | Y | N | N | N | N | N | N | N | N |
| 4Y37A09750 | ThinkSystem M.2 NVMe 2-Bay RAID Adapter | N | N | N | N | N | N | N | Y | N | Y | N | N | N | N | N | N | N | N |
| 4Y37A09738 | ThinkSystem M.2 SATA/NVMe 2-Bay Enablement Kit | N | N | N | N | N | N | N | Y | N | Y | N | N | N | N | N | N | N | N |
| 4Y37A79663 | ThinkSystem M.2 SATA/x4 NVMe 2-Bay Adapter | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
| M.2 side-by-side adapter in a PCIe adapter bracket | |||||||||||||||||||
| 4C57A85377 | ThinkSystem M.2 SATA/NVMe 2-Bay Enablement Adapter | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
| M.2 adapters with back-to-back design | |||||||||||||||||||
| 7Y37A01092 | ThinkSystem M.2 Enablement Kit | N | N | N | N | N | N | N | N | N | N | Y | Y | Y | Y | N | N | N | N |
| 7Y37A01093 | ThinkSystem M.2 with Mirroring Enablement Kit | N | N | N | N | N | N | N | N | N | N | Y | Y | Y | Y | N | N | N | N |
| 4M17A60519 | ThinkSystem SE350 M.2 Mirroring Enablement Kit | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
| M.2 4-bay adapters (SE350 only) | |||||||||||||||||||
| 4M17A37281 | ThinkSystem SE350 M.2 SATA/NVMe 4-bay Data Drive Enablement Kit | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
| 4M17A37606 | ThinkSystem SE350 M.2 SATA 4-Bay Data RAID Mirroring Enablement Kit | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
| M.2 thermal kit (some servers) | |||||||||||||||||||
| 4XH7A08791 | ThinkSystem SR650/SR550/SR590 M.2 Thermal Kit | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
| Part Number | Description | 2S Intel V1 | Dense V1 | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ST550 (7X09 / 7X10) |
SR530 (7X07 / 7X08) |
SR550 (7X03 / 7X04) |
SR570 (7Y02 / 7Y03) |
SR590 (7X98 / 7X99) |
SR630 (7X01 / 7X02) |
SR650 (7X05 / 7X06) |
SR670 (7Y36 / 7Y37) |
SD530 (7X21) |
SD650 (7X58) |
SN550 (7X16) |
SN850 (7X15) |
||
| Hot-swap M.2 adapter (install in a drive bay) | |||||||||||||
| CD0S | ThinkSystem M.2 RAID B550d-2HS SATA/NVMe Enablement Kit - Controller Board | N | N | N | N | N | N | N | N | N | N | N | N |
| C217 | ThinkSystem M.2 RAID B540d-2HS SATA/NVMe Enablement Kit - Controller Board | N | N | N | N | N | N | N | N | N | N | N | N |
| Hot-swap M.2 adapter (install in a PCIe slot) | |||||||||||||
| CCCZ | ThinkSystem M.2 RAID B550p-2HS SATA/NVMe Enablement Kit | N | N | N | N | N | N | N | N | N | N | N | N |
| C0JJ | ThinkSystem M.2 RAID B540p-2HS SATA/NVMe Adapter | N | N | N | N | N | N | N | N | N | N | N | N |
| M.2 adapters internal adapters | |||||||||||||
| 4Y37B09898 | ThinkSystem M.2 RAID B550i-2i SATA/NVMe Enablement Kit | N | N | N | N | N | N | N | N | N | N | N | N |
| 4Y37A93746 | ThinkSystem M.2 RAID B545i-2i SATA/NVMe Adapter | N | N | N | N | N | N | N | N | N | N | N | N |
| 4Y37B09897 | ThinkSystem M.2 B350i-2i NVMe Enablement Kit | N | N | N | N | N | N | N | N | N | N | N | N |
| 4Y37A90063 | ThinkSystem M.2 RAID B540i-2i SATA/NVMe Adapter | N | N | N | N | N | N | N | N | N | N | N | N |
| BZPA | ThinkEdge SE455 V3 M.2 RAID B540i-2i SATA/NVMe Adapter with Carrier | N | N | N | N | N | N | N | N | N | N | N | N |
| 4Y37A09739 | ThinkSystem M.2 SATA 2-Bay RAID Adapter | N | N | N | N | N | N | N | N | N | N | N | N |
| 4Y37A09750 | ThinkSystem M.2 NVMe 2-Bay RAID Adapter | N | N | N | N | N | N | N | N | N | N | N | N |
| 4Y37A09738 | ThinkSystem M.2 SATA/NVMe 2-Bay Enablement Kit | N | N | N | N | N | N | N | N | N | N | N | N |
| 4Y37A79663 | ThinkSystem M.2 SATA/x4 NVMe 2-Bay Adapter | N | N | N | N | N | N | N | N | N | N | N | N |
| M.2 side-by-side adapter in a PCIe adapter bracket | |||||||||||||
| 4C57A85377 | ThinkSystem M.2 SATA/NVMe 2-Bay Enablement Adapter | N | N | N | N | N | N | N | N | N | N | N | N |
| M.2 adapters with back-to-back design | |||||||||||||
| 7Y37A01092 | ThinkSystem M.2 Enablement Kit | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y1 | Y |
| 7Y37A01093 | ThinkSystem M.2 with Mirroring Enablement Kit | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
| 4M17A60519 | ThinkSystem SE350 M.2 Mirroring Enablement Kit | N | N | N | N | N | N | N | N | N | N | N | N |
| M.2 4-bay adapters (SE350 only) | |||||||||||||
| 4M17A37281 | ThinkSystem SE350 M.2 SATA/NVMe 4-bay Data Drive Enablement Kit | N | N | N | N | N | N | N | N | N | N | N | N |
| 4M17A37606 | ThinkSystem SE350 M.2 SATA 4-Bay Data RAID Mirroring Enablement Kit | N | N | N | N | N | N | N | N | N | N | N | N |
| M.2 thermal kit (some servers) | |||||||||||||
| 4XH7A08791 | ThinkSystem SR650/SR550/SR590 M.2 Thermal Kit | N | N | Y | N | N | N | Y | N | N | N | N | N |
- Support of the M.2 Enablement Kit (7Y37A01092) in the SN550 is configure-to-order only. It cannot be installed in the SN550 as a field upgrade option.
Operating system support
The adapters support the following operating systems:
- Hot-swap M.2 adapters - drive-bay based
- ThinkSystem SR630 V4 Front M.2 RAID B550d-2HS SATA/NVMe Enablement Kit, 4XH7B11659
- ThinkSystem SR650/a V4 Front M.2 RAID B550d-2HS SATA/NVMe Enablement Kit, 4XH7B11660
- ThinkSystem SR630 V4 M.2 RAID B540d-2HS SATA/NVMe Enablement Kit, 4XH7B04175
- ThinkSystem SR650/a V4 M.2 RAID B540d-2HS SATA/NVMe Enablement Kit, 4XH7B03857
- Hot-swap M.2 adapters - PCIe-slot based
- ThinkSystem SR630 V4 Rear M.2 RAID B550p-2HS SATA/NVMe Enablement Kit, 4XH7B11658
- ThinkSystem SR650/a V4 Rear M.2 RAID B550p-2HS SATA/NVMe Enablement Kit, 4XH7B11661
- ThinkSystem M.2 RAID B550p-2HS SATA/NVMe Enablement Kit, 4XH7B11701
- ThinkSystem SR630 V4 M.2 RAID B540p 2HS SATA/NVMe Kit, 4XH7A96836
- ThinkSystem SR650/a V4 M.2 RAID B540p-2HS SATA/NVMe Enablement Kit, 4XH7B03860
- ThinkSystem SR850 V4/SR860 V4 Rear M.2 RAID B540p-2HS SATA/NVMe Enablement Kit, 4XH7B08878
- Internal M.2 adapters with side-by-side design
- ThinkSystem M.2 RAID B550i-2i SATA/NVMe Enablement Kit, 4Y37B09898
- ThinkSystem M.2 RAID B545i-2i SATA/NVMe Adapter, 4Y37A93746
- ThinkSystem M.2 RAID B540i-2i SATA/NVMe Adapter, 4Y37A90063
- ThinkSystem M.2 B350i-2i NVMe Enablement Kit, 4Y37B09897 - OS independent
- ThinkSystem M.2 B340i-2i NVMe Enablement Adapter, 4Y37A91802 - OS independent
- ThinkSystem M.2 SATA 2-Bay RAID Adapter, 4Y37A09739
- ThinkSystem M.2 NVMe 2-Bay RAID Adapter, 4Y37A09750
- ThinkSystem M.2 SATA/NVMe 2-Bay Enablement Kit, 4Y37A09738 - OS independent
- ThinkSystem M.2 SATA/x4 NVMe 2-Bay Adapter, 4Y37A79663 - OS independent
- M.2 side-by-side adapter in a PCIe adapter bracket
- ThinkSystem M.2 SATA/NVMe 2-Bay Enablement Adapter, 4C57A85377 - OS independent
- Internal M.2 adapters with back-to-back design
- ThinkSystem M.2 Enablement Kit, 7Y37A01092
- ThinkSystem M.2 with Mirroring Enablement Kit, 7Y37A01093
- ThinkSystem SE350 M.2 Mirroring Enablement Kit, 4M17A60519
- M.2 4-bay adapters (SE350 only)
- ThinkSystem SE350 M.2 SATA/NVMe 4-bay Data Drive Enablement Kit, 4M17A37281 - OS independent
- ThinkSystem SE350 M.2 SATA 4-Bay Data RAID Mirroring Enablement Kit, 4M17A37606
Tip: These tables are automatically generated based on data from Lenovo ServerProven. Other M.2 adapters are considered operating system independent.
ThinkSystem SR630 V4 Front M.2 RAID B550d-2HS SATA/NVMe Enablement Kit, 4XH7B11659
The following table lists the OS support for the ThinkSystem SR630 V4 Front M.2 RAID B550d-2HS SATA/NVMe Enablement Kit.
| Operating systems | SR630 V4 |
|---|---|
| Microsoft Windows Server 2022 | Y |
| Microsoft Windows Server 2025 | Y |
| Red Hat Enterprise Linux 9.4 | Y |
| Red Hat Enterprise Linux 9.5 | Y |
| Red Hat Enterprise Linux 9.6 | Y |
| Red Hat Enterprise Linux 9.7 | Y |
| Red Hat Enterprise Linux 9.8 | Y |
| Red Hat Enterprise Linux 10.0 | Y |
| Red Hat Enterprise Linux 10.1 | Y |
| Red Hat Enterprise Linux 10.2 | Y |
| SUSE Linux Enterprise Server 15 SP6 | Y |
| SUSE Linux Enterprise Server 15 SP7 | Y |
| SUSE Linux Enterprise Server 16 | Y |
| Ubuntu 26.04 LTS or later with HWE kernel | Y |
| VMware vSphere Hypervisor (ESXi) 8.0 U3 | Y |
| VMware vSphere Hypervisor (ESXi) 9.0 | Y |
| VMware vSphere Hypervisor (ESXi) 9.1 | Y |
ThinkSystem SR650/a V4 Front M.2 RAID B550d-2HS SATA/NVMe Enablement Kit, 4XH7B11660
The following table lists the OS support for the ThinkSystem SR650/a V4 Front M.2 RAID B550d-2HS SATA/NVMe Enablement Kit.
| Operating systems | SR650 V4/SR650a V4 |
|---|---|
| Microsoft Windows Server 2022 | Y |
| Microsoft Windows Server 2025 | Y |
| Red Hat Enterprise Linux 9.4 | Y |
| Red Hat Enterprise Linux 9.5 | Y |
| Red Hat Enterprise Linux 9.6 | Y |
| Red Hat Enterprise Linux 9.7 | Y |
| Red Hat Enterprise Linux 9.8 | Y |
| Red Hat Enterprise Linux 10.0 | Y |
| Red Hat Enterprise Linux 10.1 | Y |
| Red Hat Enterprise Linux 10.2 | Y |
| SUSE Linux Enterprise Server 15 SP6 | Y |
| SUSE Linux Enterprise Server 15 SP7 | Y |
| SUSE Linux Enterprise Server 16 | Y |
| Ubuntu 26.04 LTS or later with HWE kernel | Y |
| VMware vSphere Hypervisor (ESXi) 8.0 U3 | Y |
| VMware vSphere Hypervisor (ESXi) 9.0 | Y |
| VMware vSphere Hypervisor (ESXi) 9.1 | Y |
ThinkSystem SR630 V4 M.2 RAID B540d-2HS SATA/NVMe Enablement Kit, 4XH7B04175
| Operating systems | SR630 V4 |
|---|---|
| Microsoft Windows Server 2022 | Y |
| Microsoft Windows Server 2025 | Y |
| Red Hat Enterprise Linux 9.4 | Y |
| Red Hat Enterprise Linux 9.5 | Y |
| Red Hat Enterprise Linux 9.6 | Y |
| Red Hat Enterprise Linux 9.7 | Y |
| Red Hat Enterprise Linux 9.8 | Y |
| Red Hat Enterprise Linux 10.0 | Y |
| Red Hat Enterprise Linux 10.1 | Y |
| Red Hat Enterprise Linux 10.2 | Y |
| SUSE Linux Enterprise Server 15 SP6 | Y |
| Ubuntu 24.04 LTS or later with HWE kernel | Y |
| Ubuntu 26.04 LTS or later with HWE kernel | Y |
| VMware vSphere Hypervisor (ESXi) 8.0 U3 | Y |
| VMware vSphere Hypervisor (ESXi) 9.0 | Y |
| VMware vSphere Hypervisor (ESXi) 9.1 | Y |
ThinkSystem SR650/a V4 M.2 RAID B540d-2HS SATA/NVMe Enablement Kit, 4XH7B03857
| Operating systems | SR650 V4/SR650a V4 |
|---|---|
| Microsoft Windows Server 2022 | Y |
| Microsoft Windows Server 2025 | Y |
| Red Hat Enterprise Linux 9.4 | Y |
| Red Hat Enterprise Linux 9.5 | Y |
| Red Hat Enterprise Linux 9.6 | Y |
| Red Hat Enterprise Linux 9.7 | Y |
| Red Hat Enterprise Linux 9.8 | Y |
| Red Hat Enterprise Linux 10.0 | Y |
| Red Hat Enterprise Linux 10.1 | Y |
| Red Hat Enterprise Linux 10.2 | Y |
| SUSE Linux Enterprise Server 15 SP6 | Y |
| SUSE Linux Enterprise Server 16 | Y |
| Ubuntu 24.04 LTS or later with HWE kernel | Y |
| Ubuntu 26.04 LTS or later with HWE kernel | Y |
| VMware vSphere Hypervisor (ESXi) 8.0 U3 | Y |
| VMware vSphere Hypervisor (ESXi) 9.0 | Y |
| VMware vSphere Hypervisor (ESXi) 9.1 | Y |
ThinkSystem SR630 V4 Rear M.2 RAID B550p-2HS SATA/NVMe Enablement Kit, 4XH7B11658
The following table lists the OS support for the ThinkSystem SR630 V4 Rear M.2 RAID B550p-2HS SATA/NVMe Enablement Kit.
| Operating systems | SR630 V4 |
|---|---|
| Microsoft Windows Server 2022 | Y |
| Microsoft Windows Server 2025 | Y |
| Red Hat Enterprise Linux 9.4 | Y |
| Red Hat Enterprise Linux 9.5 | Y |
| Red Hat Enterprise Linux 9.6 | Y |
| Red Hat Enterprise Linux 9.7 | Y |
| Red Hat Enterprise Linux 9.8 | Y |
| Red Hat Enterprise Linux 10.0 | Y |
| Red Hat Enterprise Linux 10.1 | Y |
| Red Hat Enterprise Linux 10.2 | Y |
| SUSE Linux Enterprise Server 15 SP6 | Y |
| SUSE Linux Enterprise Server 15 SP7 | Y |
| SUSE Linux Enterprise Server 16 | Y |
| Ubuntu 26.04 LTS or later with HWE kernel | Y |
| VMware vSphere Hypervisor (ESXi) 8.0 U3 | Y |
| VMware vSphere Hypervisor (ESXi) 9.0 | Y |
| VMware vSphere Hypervisor (ESXi) 9.1 | Y |
ThinkSystem SR650/a V4 Rear M.2 RAID B550p-2HS SATA/NVMe Enablement Kit, 4XH7B11661
The following table lists the OS support for the ThinkSystem SR650/a V4 Rear M.2 RAID B550p-2HS SATA/NVMe Enablement Kit.
| Operating systems | SR650 V4/SR650a V4 |
|---|---|
| Microsoft Windows Server 2022 | Y |
| Microsoft Windows Server 2025 | Y |
| Red Hat Enterprise Linux 9.4 | Y |
| Red Hat Enterprise Linux 9.5 | Y |
| Red Hat Enterprise Linux 9.6 | Y |
| Red Hat Enterprise Linux 9.7 | Y |
| Red Hat Enterprise Linux 9.8 | Y |
| Red Hat Enterprise Linux 10.0 | Y |
| Red Hat Enterprise Linux 10.1 | Y |
| Red Hat Enterprise Linux 10.2 | Y |
| SUSE Linux Enterprise Server 15 SP6 | Y |
| SUSE Linux Enterprise Server 15 SP7 | Y |
| SUSE Linux Enterprise Server 16 | Y |
| Ubuntu 26.04 LTS or later with HWE kernel | Y |
| VMware vSphere Hypervisor (ESXi) 8.0 U3 | Y |
| VMware vSphere Hypervisor (ESXi) 9.0 | Y |
| VMware vSphere Hypervisor (ESXi) 9.1 | Y |
ThinkSystem M.2 RAID B550p-2HS SATA/NVMe Enablement Kit, 4XH7B11701
The following table lists the OS support for the ThinkSystem M.2 RAID B550p-2HS SATA/NVMe Enablement Kit.
| Operating systems | SR850 V4 |
SR860 V4 |
|---|---|---|
| Microsoft Windows Server 2022 | Y | Y |
| Microsoft Windows Server 2025 | Y | Y |
| Red Hat Enterprise Linux 9.6 | Y | Y |
| Red Hat Enterprise Linux 9.7 | Y | Y |
| Red Hat Enterprise Linux 9.8 | Y | Y |
| Red Hat Enterprise Linux 10.0 | Y | Y |
| Red Hat Enterprise Linux 10.1 | Y | Y |
| Red Hat Enterprise Linux 10.2 | Y | Y |
| SUSE Linux Enterprise Server 15 SP7 | Y | Y |
| SUSE Linux Enterprise Server 16 | Y | Y |
| Ubuntu 26.04 LTS or later with HWE kernel | Y | Y |
| VMware vSphere Hypervisor (ESXi) 9.0 | Y | Y |
| VMware vSphere Hypervisor (ESXi) 9.1 | Y | Y |
ThinkSystem SR630 V4 M.2 RAID B540p 2HS SATA/NVMe Kit, 4XH7A96836
The following table lists the OS support for the ThinkSystem SR630 V4 M.2 RAID B540p 2HS SATA/NVMe Kit.
| Operating systems | SR630 V4 |
|---|---|
| Red Hat Enterprise Linux 9.8 | Y |
| Red Hat Enterprise Linux 10.1 | Y |
| Red Hat Enterprise Linux 10.2 | Y |
| Ubuntu 26.04 LTS or later with HWE kernel | Y |
| VMware vSphere Hypervisor (ESXi) 9.1 | Y |
ThinkSystem SR650/a V4 M.2 RAID B540p-2HS SATA/NVMe Enablement Kit, 4XH7B03860
The following table lists the OS support for the ThinkSystem SR650/a V4 M.2 RAID B540p-2HS SATA/NVMe Enablement Kit.
| Operating systems | SR650 V4/SR650a V4 |
|---|---|
| Microsoft Windows Server 2022 | Y |
| Microsoft Windows Server 2025 | Y |
| Red Hat Enterprise Linux 9.4 | Y |
| Red Hat Enterprise Linux 9.5 | Y |
| Red Hat Enterprise Linux 9.8 | Y |
| Red Hat Enterprise Linux 10.2 | Y |
| SUSE Linux Enterprise Server 15 SP6 | Y |
| Ubuntu 24.04 LTS or later with HWE kernel | Y |
| Ubuntu 26.04 LTS or later with HWE kernel | Y |
| VMware vSphere Hypervisor (ESXi) 8.0 U3 | Y |
| VMware vSphere Hypervisor (ESXi) 9.0 | Y |
| VMware vSphere Hypervisor (ESXi) 9.1 | Y |
ThinkSystem SR850 V4/SR860 V4 Rear M.2 RAID B540p-2HS SATA/NVMe Enablement Kit, 4XH7B08878
The following table lists the OS support for the ThinkSystem SR850 V4/SR860 V4 Rear M.2 RAID B540p-2HS SATA/NVMe Enablement Kit.
| Operating systems | SR850 V4 |
SR860 V4 |
|---|---|---|
| Microsoft Windows Server 2022 | Y | Y |
| Microsoft Windows Server 2025 | Y | Y |
| Red Hat Enterprise Linux 9.6 | Y | Y |
| Red Hat Enterprise Linux 9.7 | Y | Y |
| Red Hat Enterprise Linux 9.8 | Y | Y |
| Red Hat Enterprise Linux 10.0 | Y | Y |
| Red Hat Enterprise Linux 10.1 | Y | Y |
| Red Hat Enterprise Linux 10.2 | Y | Y |
| SUSE Linux Enterprise Server 15 SP7 | Y | Y |
| SUSE Linux Enterprise Server 16 | Y | Y |
| Ubuntu 26.04 LTS or later with HWE kernel | Y | Y |
| VMware vSphere Hypervisor (ESXi) 9.0 | Y | Y |
| VMware vSphere Hypervisor (ESXi) 9.1 | Y | Y |
ThinkSystem M.2 RAID B550i-2i SATA/NVMe Enablement Kit, 4Y37B09898
The following table lists the OS support for the ThinkSystem M.2 RAID B550i-2i SATA/NVMe Enablement Kit.
| Operating systems | SR630 V4 |
SR650 V4/SR650a V4 |
SR850 V4 |
SR860 V4 |
|---|---|---|---|---|
| Microsoft Windows Server 2022 | Y | Y | Y | Y |
| Microsoft Windows Server 2025 | Y | Y | Y | Y |
| Red Hat Enterprise Linux 9.4 | Y | Y | N | N |
| Red Hat Enterprise Linux 9.5 | Y | Y | N | N |
| Red Hat Enterprise Linux 9.6 | Y | Y | Y | Y |
| Red Hat Enterprise Linux 9.7 | Y | Y | Y | Y |
| Red Hat Enterprise Linux 9.8 | Y | Y | Y | Y |
| Red Hat Enterprise Linux 10.0 | Y | Y | Y | Y |
| Red Hat Enterprise Linux 10.1 | Y | Y | Y | Y |
| Red Hat Enterprise Linux 10.2 | Y | Y | Y | Y |
| SUSE Linux Enterprise Server 15 SP6 | Y | Y | N | N |
| SUSE Linux Enterprise Server 15 SP7 | Y | Y | Y | Y |
| SUSE Linux Enterprise Server 16 | Y | Y | Y | Y |
| Ubuntu 26.04 LTS or later with HWE kernel | Y | Y | Y | Y |
| VMware vSphere Hypervisor (ESXi) 8.0 U3 | Y | Y | N | N |
| VMware vSphere Hypervisor (ESXi) 9.0 | Y | Y | Y | Y |
| VMware vSphere Hypervisor (ESXi) 9.1 | Y | Y | Y | Y |
ThinkSystem M.2 RAID B545i-2i SATA/NVMe Adapter, 4Y37A93746
The following table lists the OS support for the ThinkSystem M.2 RAID B545i-2i SATA/NVMe Adapter.
| Operating systems | SR630 V4 |
SR650 V4/SR650a V4 |
SR850 V4 |
SR860 V4 |
|---|---|---|---|---|
| Microsoft Windows Server 2022 | Y | Y 1 | Y | Y |
| Microsoft Windows Server 2025 | Y | Y 1 | Y | Y |
| Red Hat Enterprise Linux 9.4 | Y | Y 1 | N | N |
| Red Hat Enterprise Linux 9.5 | Y 1 | Y 1 | N | N |
| Red Hat Enterprise Linux 9.6 | Y | Y | Y | Y |
| Red Hat Enterprise Linux 9.7 | Y | Y | Y | Y |
| Red Hat Enterprise Linux 9.8 | Y | Y | Y | Y |
| Red Hat Enterprise Linux 10.0 | Y | Y | Y | Y |
| Red Hat Enterprise Linux 10.1 | Y | Y | Y | Y |
| Red Hat Enterprise Linux 10.2 | Y | Y | Y | Y |
| SUSE Linux Enterprise Server 15 SP6 | Y | Y 1 | N | N |
| SUSE Linux Enterprise Server 15 SP7 | Y | Y | Y | Y |
| SUSE Linux Enterprise Server 16 | Y | Y | Y | Y |
| Ubuntu 24.04 LTS or later with HWE kernel | Y | Y 1 | Y | Y |
| Ubuntu 26.04 LTS or later with HWE kernel | Y | Y | Y | Y |
| VMware vSphere Hypervisor (ESXi) 8.0 U3 | Y 1 | Y 1 | N | N |
| VMware vSphere Hypervisor (ESXi) 9.0 | Y 1 | Y 1 | Y | Y |
| VMware vSphere Hypervisor (ESXi) 9.1 | Y | Y | Y | Y |
1 For limitation, please refer Support Tip TT2940
ThinkSystem M.2 RAID B540i-2i SATA/NVMe Adapter, 4Y37A90063
The following table lists the OS support for the ThinkSystem M.2 RAID B540i-2i SATA/NVMe Adapter.
| Operating systems | SE455 V3 |
ST650 V3 (5th Gen Xeon) |
SD535 V3 |
SR650 V3 (5th Gen Xeon) |
ST250 V3 |
ST250 V3 |
SR250 V3 |
SR250 V3 |
SR630 V3 (4th Gen Xeon) |
SR630 V3 (5th Gen Xeon) |
SR645 V3 |
ST650 V3 (4th Gen Xeon) |
SR860 V3 |
SR850 V3 |
SR655 V3 |
SR650 V3 (4th Gen Xeon) |
SR635 V3 |
SE450 |
SR665 V3 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Microsoft Windows 10 | N | N | N | Y | N | N | N | N | N | Y | Y | N | N | N | Y | Y | Y | N | Y |
| Microsoft Windows 11 | N | N | N | Y | N | N | N | N | Y | Y | Y | N | N | N | Y | Y | Y | N | Y |
| Microsoft Windows Server 2019 | Y | Y | N | Y | N | N | N | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
| Microsoft Windows Server 2022 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
| Microsoft Windows Server 2025 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
| Red Hat Enterprise Linux 8.6 | Y | N | N | N | N | N | N | N | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | Y |
| Red Hat Enterprise Linux 8.7 | N | N | N | N | N | N | N | N | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | Y |
| Red Hat Enterprise Linux 8.8 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
| Red Hat Enterprise Linux 8.9 | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
| Red Hat Enterprise Linux 8.10 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
| Red Hat Enterprise Linux 9.0 | Y | N | N | N | N | N | N | N | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | Y |
| Red Hat Enterprise Linux 9.1 | N | N | N | N | N | N | N | N | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | Y |
| Red Hat Enterprise Linux 9.2 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
| Red Hat Enterprise Linux 9.3 | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
| Red Hat Enterprise Linux 9.4 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
| Red Hat Enterprise Linux 9.5 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
| Red Hat Enterprise Linux 9.6 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
| Red Hat Enterprise Linux 9.7 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
| Red Hat Enterprise Linux 9.8 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
| Red Hat Enterprise Linux 10.0 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
| Red Hat Enterprise Linux 10.1 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
| Red Hat Enterprise Linux 10.2 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
| SUSE Linux Enterprise Server 15 SP4 | Y | N | N | N | N | N | N | N | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | Y |
| SUSE Linux Enterprise Server 15 SP4 with Xen | Y | N | N | N | N | N | N | N | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | Y |
| SUSE Linux Enterprise Server 15 SP5 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
| SUSE Linux Enterprise Server 15 SP5 with Xen | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
| SUSE Linux Enterprise Server 15 SP6 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
| SUSE Linux Enterprise Server 15 SP7 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
| SUSE Linux Enterprise Server 16 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y |
| Ubuntu 24.04 LTS or later with HWE kernel | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
| Ubuntu 26.04 LTS or later with HWE kernel | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
| VMware vSphere Hypervisor (ESXi) 7.0 U3 | Y | Y | Y | Y | N | N | N | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
| VMware vSphere Hypervisor (ESXi) 8.0 | N | N | N | N | N | N | N | N | Y | N | Y | N | N | N | Y | Y | Y | Y | Y |
| VMware vSphere Hypervisor (ESXi) 8.0 U1 | Y | N | N | N | N | N | N | N | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | Y |
| VMware vSphere Hypervisor (ESXi) 8.0 U2 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
| VMware vSphere Hypervisor (ESXi) 8.0 U3 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
| VMware vSphere Hypervisor (ESXi) 9.0 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
| VMware vSphere Hypervisor (ESXi) 9.1 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
ThinkSystem M.2 SATA 2-Bay RAID Adapter, 4Y37A09739
| Operating systems | SR635 |
SR655 |
SR645 |
SR665 |
SR630 V2 |
SR650 V2 |
SR670 V2 |
SR860 V2 |
ST650 V2 |
ST650 V2 |
SN550 V2 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| Microsoft Windows Server 2016 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
| Microsoft Windows Server 2019 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
| Red Hat Enterprise Linux 7.6 | Y 1 | Y 1 | Y 1 | Y 1 | N | N | N | N | N | N | N |
| Red Hat Enterprise Linux 7.7 | Y 1 | Y 1 | Y 1 | Y 1 | N | N | N | N | N | N | N |
| Red Hat Enterprise Linux 7.8 | Y 1 | Y 1 | Y 1 | Y 1 | N | N | N | N | N | N | N |
| Red Hat Enterprise Linux 7.9 | Y 1 | Y 1 | Y 1 | Y 1 | Y | Y | Y | Y | Y | Y | Y |
| Red Hat Enterprise Linux 8.0 | Y 1 | Y 1 | N | N | N | N | N | N | N | N | N |
| Red Hat Enterprise Linux 8.1 | Y 1 | Y 1 | Y 1 | Y 1 | N | N | N | N | N | N | N |
| Red Hat Enterprise Linux 8.2 | Y 1 | Y 1 | Y 1 | Y 1 | Y | Y | Y | Y | Y | Y | Y |
| Red Hat Enterprise Linux 8.3 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
| Red Hat Enterprise Linux 8.4 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
| Red Hat Enterprise Linux 8.5 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
| Red Hat Enterprise Linux 8.6 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
| SUSE Linux Enterprise Server 12 SP5 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
| SUSE Linux Enterprise Server 12 SP5 with Xen | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
| SUSE Linux Enterprise Server 15 SP1 | Y 1 | Y 1 | Y 1 | Y 1 | N | N | N | N | N | N | N |
| SUSE Linux Enterprise Server 15 SP1 with Xen | Y 1 | Y 1 | Y 1 | Y 1 | N | N | N | N | N | N | N |
| SUSE Linux Enterprise Server 15 SP2 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
| SUSE Linux Enterprise Server 15 SP2 with Xen | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
| SUSE Linux Enterprise Server 15 SP3 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
| SUSE Linux Enterprise Server 15 SP3 with Xen | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
| Ubuntu 18.04.5 LTS or later with HWE kernel | N | N | N | N | Y | Y | Y | N | Y | Y | Y |
| Ubuntu 20.04 LTS or later with HWE kernel | N | N | N | N | Y | Y | N | N | N | N | N |
| Ubuntu 22.04 LTS or later with HWE kernel | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
| VMware vSphere Hypervisor (ESXi) 6.7 U3 | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
| VMware vSphere Hypervisor (ESXi) 7.0 | Y 1 | Y 1 | Y 1 | Y 1 | N | N | N | N | N | N | N |
| VMware vSphere Hypervisor (ESXi) 7.0 U1 | Y 1 | Y 1 | Y | Y | N | N | N | Y | N | N | N |
| VMware vSphere Hypervisor (ESXi) 7.0 U2 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
| VMware vSphere Hypervisor (ESXi) 7.0 U3 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
1 The OS is not supported with EPYC 7003 processors.
ThinkSystem M.2 NVMe 2-Bay RAID Adapter, 4Y37A09750
The following table lists the OS support for the ThinkSystem M.2 NVMe 2-Bay RAID Adapter.
| Operating systems | SR650 V3 (4th Gen Xeon) |
ST650 V3 (5th Gen Xeon) |
SR685a V3 |
SR650 V3 (5th Gen Xeon) |
SR630 V3 (4th Gen Xeon) |
SR630 V3 (5th Gen Xeon) |
SR950 V3 |
SR675 V3 |
ST650 V3 (4th Gen Xeon) |
SR860 V3 |
SR850 V3 |
SR655 V3 |
SR645 |
SR635 V3 |
SN550 V2 |
ST650 V2 |
ST650 V2 |
SR860 V2 |
SR670 V2 |
SR650 V2 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Microsoft Windows Server 2016 | N | N | N | N | N | N | N | N | N | N | N | N | Y | N | Y | Y | Y | Y | Y | Y |
| Microsoft Windows Server 2019 | Y 1 | Y | N | Y | Y 2 | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
| Microsoft Windows Server 2022 | Y | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
| Microsoft Windows Server 2025 | Y | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y | Y | Y |
| Red Hat Enterprise Linux 7.7 | N | N | N | N | N | N | N | N | N | N | N | N | Y 6 | N | N | N | N | N | N | N |
| Red Hat Enterprise Linux 7.8 | N | N | N | N | N | N | N | N | N | N | N | N | Y 6 | N | N | N | N | N | N | N |
| Red Hat Enterprise Linux 7.9 | N | N | N | N | N | N | N | N | N | N | N | N | Y 6 | N | Y | Y | Y | Y | Y | Y |
| Red Hat Enterprise Linux 8.1 | N | N | N | N | N | N | N | N | N | N | N | N | Y 6 | N | N | N | N | N | N | N |
| Red Hat Enterprise Linux 8.2 | N | N | N | N | N | N | N | N | N | N | N | N | Y 6 | N | Y | Y | Y | Y | Y | Y |
| Red Hat Enterprise Linux 8.3 | N | N | N | N | N | N | N | N | N | N | N | N | Y | N | Y | Y | Y | Y | Y | Y |
| Red Hat Enterprise Linux 8.4 | N | N | N | N | N | N | N | N | N | N | N | N | Y | N | Y | Y | Y | Y | Y | Y |
| Red Hat Enterprise Linux 8.5 | N | N | N | N | N | N | N | N | N | N | N | N | Y | N | Y | Y | Y | Y | Y | Y |
| Red Hat Enterprise Linux 8.6 | Y 2 | N | N | N | Y 3 | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
| Red Hat Enterprise Linux 8.7 | Y | N | N | N | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
| Red Hat Enterprise Linux 8.8 | Y | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
| Red Hat Enterprise Linux 8.9 | Y | N | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
| Red Hat Enterprise Linux 8.10 | Y | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
| Red Hat Enterprise Linux 9.0 | Y | N | N | N | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
| Red Hat Enterprise Linux 9.1 | Y | N | N | N | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y |
| Red Hat Enterprise Linux 9.2 | Y | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
| Red Hat Enterprise Linux 9.3 | Y | N | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
| Red Hat Enterprise Linux 9.4 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
| SUSE Linux Enterprise Server 12 SP5 | N | N | N | N | N | N | N | N | N | N | N | N | Y | N | Y | Y | Y | Y | Y | Y |
| SUSE Linux Enterprise Server 12 SP5 with Xen | N | N | N | N | N | N | N | N | N | N | N | N | Y | N | Y | Y | Y | Y | Y | Y |
| SUSE Linux Enterprise Server 15 SP1 | N | N | N | N | N | N | N | N | N | N | N | N | Y 6 | N | N | N | N | N | N | N |
| SUSE Linux Enterprise Server 15 SP1 with Xen | N | N | N | N | N | N | N | N | N | N | N | N | Y 6 | N | N | N | N | N | N | N |
| SUSE Linux Enterprise Server 15 SP2 | N | N | N | N | N | N | N | N | N | N | N | N | Y | N | Y | Y | Y | Y | Y | Y |
| SUSE Linux Enterprise Server 15 SP2 with Xen | N | N | N | N | N | N | N | N | N | N | N | N | Y | N | Y | Y | Y | Y | Y | Y |
| SUSE Linux Enterprise Server 15 SP3 | N | N | N | N | N | N | N | N | N | N | N | N | Y | N | Y | Y | Y | Y | Y | Y |
| SUSE Linux Enterprise Server 15 SP3 with Xen | N | N | N | N | N | N | N | N | N | N | N | N | Y | N | Y | Y | Y | Y | Y | Y |
| SUSE Linux Enterprise Server 15 SP4 | Y | N | N | N | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
| SUSE Linux Enterprise Server 15 SP4 with Xen | Y | N | N | N | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
| SUSE Linux Enterprise Server 15 SP5 | Y | Y | N | Y | Y | Y | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
| SUSE Linux Enterprise Server 15 SP5 with Xen | Y | Y | N | Y | Y | Y | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
| SUSE Linux Enterprise Server 15 SP6 | Y | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
| Ubuntu 18.04.5 LTS or later with HWE kernel | N | N | N | N | N | N | N | N | N | N | N | N | N | N | Y | Y | Y | N | Y | Y |
| Ubuntu 20.04.5 LTS or later with HWE kernel | N | N | N | N | N | N | N | Y | N | Y 5 | Y 5 | Y | N | Y | N | N | N | N | N | N |
| Ubuntu 20.04 LTS or later with HWE kernel | Y | N | N | Y | Y | Y | N | N | N | N | N | N | N | N | N | N | N | N | N | Y |
| Ubuntu 22.04.3 LTS or later with HWE kernel | N | Y | N | Y 4 | N | Y | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
| Ubuntu 22.04.5 LTS or later with HWE kernel | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
| Ubuntu 22.04 LTS or later with HWE kernel | Y 3 | N | Y | N | Y 1 | N | N | Y | Y | Y 5 | Y 5 | Y | Y | Y | Y | Y | Y | Y | Y | Y |
| Ubuntu 24.04 LTS or later with HWE kernel | N | Y | Y | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
| VMware vSphere Hypervisor (ESXi) 6.7 U3 | N | N | N | N | N | N | N | N | N | N | N | N | Y | N | Y | Y | Y | N | Y | Y |
| VMware vSphere Hypervisor (ESXi) 7.0 | N | N | N | N | N | N | N | N | N | N | N | N | Y 6 | N | N | N | N | N | N | N |
| VMware vSphere Hypervisor (ESXi) 7.0 U1 | N | N | N | N | N | N | N | N | N | N | N | N | Y | N | N | N | N | Y | N | N |
| VMware vSphere Hypervisor (ESXi) 7.0 U2 | N | N | N | N | N | N | N | N | N | N | N | N | Y | N | Y | Y | Y | Y | Y | Y |
| VMware vSphere Hypervisor (ESXi) 7.0 U3 | Y 2 | Y | N | Y | Y 2 | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
| VMware vSphere Hypervisor (ESXi) 8.0 | Y | N | N | N | Y | N | N | N | N | N | N | Y | N | Y | N | N | N | N | N | N |
| VMware vSphere Hypervisor (ESXi) 8.0 U1 | Y | N | N | N | Y | N | N | Y | Y | Y | Y | Y | N | Y | N | N | N | N | N | N |
| VMware vSphere Hypervisor (ESXi) 8.0 U2 | Y | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
| VMware vSphere Hypervisor (ESXi) 8.0 U3 | Y | Y | N | Y | Y | Y | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
| VMware vSphere Hypervisor (ESXi) 9.0 | Y | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | N | Y | Y |
1 For limitation, please refer Support Tip TT1104 and Support Tip TT1112
2 For limitation, please refer Support Tip TT1104
3 For limitation, please refer Support Tip TT1104 and Support Tip TT1112 and Support Tip TT1092
4 OSE-4928 Tips:TT1844 ; OSE-177 Tips :TT1796
5 For limitation, please refer Support Tip TT1777
6 The OS is not supported with EPYC 7003 processors.
| Operating systems | SR630 V2 |
SR665 V3 |
SR645 V3 |
SR665 |
|---|---|---|---|---|
| Microsoft Windows Server 2016 | Y | N | N | Y |
| Microsoft Windows Server 2019 | Y | Y | Y | Y |
| Microsoft Windows Server 2022 | Y | Y | Y | Y |
| Microsoft Windows Server 2025 | Y | Y | Y | Y |
| Red Hat Enterprise Linux 7.7 | N | N | N | Y 1 |
| Red Hat Enterprise Linux 7.8 | N | N | N | Y 1 |
| Red Hat Enterprise Linux 7.9 | Y | N | N | Y 1 |
| Red Hat Enterprise Linux 8.1 | N | N | N | Y 1 |
| Red Hat Enterprise Linux 8.2 | Y | N | N | Y 1 |
| Red Hat Enterprise Linux 8.3 | Y | N | N | Y |
| Red Hat Enterprise Linux 8.4 | Y | N | N | Y |
| Red Hat Enterprise Linux 8.5 | Y | N | N | Y |
| Red Hat Enterprise Linux 8.6 | Y | Y | Y | Y |
| Red Hat Enterprise Linux 8.7 | Y | Y | Y | Y |
| Red Hat Enterprise Linux 8.8 | Y | Y | Y | Y |
| Red Hat Enterprise Linux 8.9 | Y | Y | Y | Y |
| Red Hat Enterprise Linux 8.10 | Y | Y | Y | Y |
| Red Hat Enterprise Linux 9.0 | Y | Y | Y | Y |
| Red Hat Enterprise Linux 9.1 | Y | Y | Y | Y |
| Red Hat Enterprise Linux 9.2 | Y | Y | Y | Y |
| Red Hat Enterprise Linux 9.3 | Y | Y | Y | Y |
| Red Hat Enterprise Linux 9.4 | Y | Y | Y | Y |
| SUSE Linux Enterprise Server 12 SP5 | Y | N | N | Y |
| SUSE Linux Enterprise Server 12 SP5 with Xen | Y | N | N | Y |
| SUSE Linux Enterprise Server 15 SP1 | N | N | N | Y 1 |
| SUSE Linux Enterprise Server 15 SP1 with Xen | N | N | N | Y 1 |
| SUSE Linux Enterprise Server 15 SP2 | Y | N | N | Y |
| SUSE Linux Enterprise Server 15 SP2 with Xen | Y | N | N | Y |
| SUSE Linux Enterprise Server 15 SP3 | Y | N | N | Y |
| SUSE Linux Enterprise Server 15 SP3 with Xen | Y | N | N | Y |
| SUSE Linux Enterprise Server 15 SP4 | Y | Y | Y | Y |
| SUSE Linux Enterprise Server 15 SP4 with Xen | Y | Y | Y | Y |
| SUSE Linux Enterprise Server 15 SP5 | Y | Y | Y | Y |
| SUSE Linux Enterprise Server 15 SP5 with Xen | Y | Y | Y | Y |
| SUSE Linux Enterprise Server 15 SP6 | Y | Y | Y | Y |
| Ubuntu 18.04.5 LTS or later with HWE kernel | Y | N | N | N |
| Ubuntu 20.04.5 LTS or later with HWE kernel | N | Y | Y | N |
| Ubuntu 20.04 LTS or later with HWE kernel | Y | N | N | N |
| Ubuntu 22.04.3 LTS or later with HWE kernel | N | N | N | N |
| Ubuntu 22.04.5 LTS or later with HWE kernel | N | Y | Y | N |
| Ubuntu 22.04 LTS or later with HWE kernel | Y | Y | Y | Y |
| Ubuntu 24.04 LTS or later with HWE kernel | N | N | N | N |
| VMware vSphere Hypervisor (ESXi) 6.7 U3 | Y | N | N | Y |
| VMware vSphere Hypervisor (ESXi) 7.0 | N | N | N | Y 1 |
| VMware vSphere Hypervisor (ESXi) 7.0 U1 | N | N | N | Y |
| VMware vSphere Hypervisor (ESXi) 7.0 U2 | Y | N | N | Y |
| VMware vSphere Hypervisor (ESXi) 7.0 U3 | Y | Y | Y | Y |
| VMware vSphere Hypervisor (ESXi) 8.0 | N | Y | Y | N |
| VMware vSphere Hypervisor (ESXi) 8.0 U1 | N | Y | Y | N |
| VMware vSphere Hypervisor (ESXi) 8.0 U2 | Y | Y | Y | Y |
| VMware vSphere Hypervisor (ESXi) 8.0 U3 | N | N | N | N |
| VMware vSphere Hypervisor (ESXi) 9.0 | Y | Y | Y | Y |
1 The OS is not supported with EPYC 7003 processors.
ThinkSystem M.2 Enablement Kit, 7Y37A01092
| Operating systems | SR950 (Xeon Gen 2) |
SR630 (Xeon Gen 1) |
SR650 (Xeon Gen 1) |
SR670 (Xeon Gen 1) |
SR670 (Xeon Gen 2) |
SR850 (Xeon Gen 1) |
SR850P (Xeon Gen 2) |
SR860 (Xeon Gen 1) |
SR950 (Xeon Gen 1) |
SR590 (Xeon Gen 1) |
ST550 (Xeon Gen 2) |
ST550 (Xeon Gen 2) |
ST550 (Xeon Gen 1) |
ST550 (Xeon Gen 1) |
SN850 (Xeon Gen 1) |
SE350 |
SD650 (Xeon Gen 1) |
SD530 (Xeon Gen 1) |
SR570 (Xeon Gen 1) |
SR550 (Xeon Gen 1) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| For OS support info. please refer to LeSI Best Recipe. | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | Y 1 | N | N | N |
| Microsoft Windows Server 2012 R2 | N | Y | Y | N | N | Y | N | Y | Y | Y | N | N | Y | Y | Y | N | N | Y | Y | Y |
| Microsoft Windows Server 2016 | Y | Y | Y | N | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
| Microsoft Windows Server 2019 | Y | Y | Y | N | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
| Microsoft Windows Server version 1709 | N | Y | Y | N | N | Y | N | Y | Y | Y | N | N | Y | Y | Y | N | N | Y | Y | Y |
| Microsoft Windows Server version 1803 | N | Y | Y | N | N | Y | N | Y | Y | N | N | N | N | N | N | N | N | Y | N | N |
| Red Hat Enterprise Linux 6.9 | N | Y | Y | N | N | Y | N | Y | Y | Y | N | N | Y | Y | Y | N | N | Y | Y | Y |
| Red Hat Enterprise Linux 6.10 | N | Y | Y | N | N | Y | N | Y | Y | Y | N | N | Y | Y | Y | N | N | Y | Y | Y |
| Red Hat Enterprise Linux 6 Server x64 Edition | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | Y |
| Red Hat Enterprise Linux 7.3 | N | Y | Y | N | N | Y | N | N | Y | N | N | N | Y | Y | Y | N | N | Y | N | Y |
| Red Hat Enterprise Linux 7.4 | N | Y | Y | N | N | Y | N | Y | Y | Y | N | N | Y | Y | Y | N | N | Y | Y | Y |
| Red Hat Enterprise Linux 7.5 | N | Y | Y | Y | Y | Y | N | Y | Y | Y | N | N | Y | Y | Y | N | N | Y | Y | Y |
| Red Hat Enterprise Linux 7.6 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
| Red Hat Enterprise Linux 7.7 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
| Red Hat Enterprise Linux 7.8 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
| Red Hat Enterprise Linux 7.9 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
| Red Hat Enterprise Linux 8.0 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | N | Y | Y | Y |
| Red Hat Enterprise Linux 8.1 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
| Red Hat Enterprise Linux 8.2 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
| Red Hat Enterprise Linux 8.3 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
| Red Hat Enterprise Linux 8.4 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
| Red Hat Enterprise Linux 8.5 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
| Red Hat Enterprise Linux 8.6 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
| SUSE Linux Enterprise Server 11 SP4 | N | Y | Y | N | N | Y | N | Y | Y | Y | N | N | Y | Y | Y | N | N | Y | Y | Y |
| SUSE Linux Enterprise Server 11 SP4 with Xen | N | Y | Y | N | N | Y | N | Y | Y | Y | N | N | Y | Y | Y | N | N | Y | Y | Y |
| SUSE Linux Enterprise Server 12 SP2 | N | Y | Y | N | N | Y | N | N | Y | N | N | N | Y | Y | Y | N | N | Y | N | Y |
| SUSE Linux Enterprise Server 12 SP2 with Xen | N | Y | Y | N | N | Y | N | N | Y | N | N | N | Y | Y | Y | N | N | Y | N | Y |
| SUSE Linux Enterprise Server 12 SP3 | N | Y | Y | N | N | Y | Y | Y | Y | Y | N | N | Y | Y | Y | N | N | Y | Y | Y |
| SUSE Linux Enterprise Server 12 SP3 with Xen | N | Y | Y | N | N | Y | Y | Y | Y | Y | N | N | Y | Y | Y | N | N | Y | Y | Y |
| SUSE Linux Enterprise Server 12 SP4 | Y | Y | Y | N | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | N | Y | Y | Y |
| SUSE Linux Enterprise Server 12 SP4 with Xen | Y | Y | Y | N | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | N | Y | Y | Y |
| SUSE Linux Enterprise Server 12 SP5 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | N | Y | Y | Y |
| SUSE Linux Enterprise Server 12 SP5 with Xen | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | N | Y | Y | Y |
| SUSE Linux Enterprise Server 15 | Y | Y | Y | N | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
| SUSE Linux Enterprise Server 15 SP1 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
| SUSE Linux Enterprise Server 15 SP1 with Xen | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
| SUSE Linux Enterprise Server 15 SP2 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
| SUSE Linux Enterprise Server 15 SP2 with Xen | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
| SUSE Linux Enterprise Server 15 SP3 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
| SUSE Linux Enterprise Server 15 SP3 with Xen | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
| SUSE Linux Enterprise Server 15 with Xen | Y | Y | Y | N | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
| Ubuntu 22.04 LTS or later with HWE kernel | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
| VMware vSphere Hypervisor (ESXi) 6.0 U3 | N | Y | Y | N | N | Y | N | Y | Y | Y | N | N | Y | Y | Y | N | N | Y | Y | Y |
| VMware vSphere Hypervisor (ESXi) 6.5 | N | Y | Y | N | N | Y | N | N | Y | N | N | N | Y | Y | Y | N | N | Y | N | Y |
| VMware vSphere Hypervisor (ESXi) 6.5 U1 | N | Y | Y | N | N | Y | N | Y | Y | Y | N | N | Y | Y | Y | N | N | Y | Y | Y |
| VMware vSphere Hypervisor (ESXi) 6.5 U2 | Y | Y | Y | N | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
| VMware vSphere Hypervisor (ESXi) 6.5 U3 | Y | Y | Y | N | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | N | Y | Y | Y |
| VMware vSphere Hypervisor (ESXi) 6.7 | N | Y | Y | N | N | Y | N | Y | Y | Y | N | N | Y | Y | Y | N | N | Y | Y | Y |
| VMware vSphere Hypervisor (ESXi) 6.7 U1 | Y | Y | Y | N | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | N | Y | Y | Y |
| VMware vSphere Hypervisor (ESXi) 6.7 U2 | Y | Y | Y | N | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
| VMware vSphere Hypervisor (ESXi) 6.7 U3 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
| VMware vSphere Hypervisor (ESXi) 7.0 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
| VMware vSphere Hypervisor (ESXi) 7.0 U1 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
| VMware vSphere Hypervisor (ESXi) 7.0 U2 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
| VMware vSphere Hypervisor (ESXi) 7.0 U3 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
1 1. This item is not a general stand-alone option for Lenovo ThinkSystem SD650 (M/T 7X58). 2. For OS support matrix, pls refer to LeSI Best Recipe. 3. This Item shall be installed/removed by Lenovo support rep only.
| Operating systems | SR530 (Xeon Gen 1) |
SR850 (Xeon Gen 2) |
SR860 (Xeon Gen 2) |
SR570 (Xeon Gen 2) |
SD650 (Xeon Gen 2) |
SR650 (Xeon Gen 2) |
SR630 (Xeon Gen 2) |
SN850 (Xeon Gen 2) |
SN550 (Xeon Gen 2) |
SD530 (Xeon Gen 2) |
SR590 (Xeon Gen 2) |
SR550 (Xeon Gen 2) |
SR530 (Xeon Gen 2) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| For OS support info. please refer to LeSI Best Recipe. | N | N | N | N | Y 1 | N | N | N | N | N | N | N | N |
| Microsoft Windows Server 2012 R2 | Y | N | N | N | N | N | N | N | N | N | N | N | N |
| Microsoft Windows Server 2016 | Y | Y | Y | Y | N | Y | Y | Y | Y | Y | Y | Y | Y |
| Microsoft Windows Server 2019 | Y | Y | Y | Y | N | Y | Y | Y | Y | Y | Y | Y | Y |
| Microsoft Windows Server version 1709 | Y | N | N | N | N | N | N | N | N | N | N | N | N |
| Microsoft Windows Server version 1803 | N | N | N | N | N | N | N | N | N | N | N | N | N |
| Red Hat Enterprise Linux 6.9 | Y | N | N | N | N | N | N | N | N | N | N | N | N |
| Red Hat Enterprise Linux 6.10 | Y | N | N | N | N | N | N | N | N | N | N | N | N |
| Red Hat Enterprise Linux 6 Server x64 Edition | N | N | N | N | N | N | N | N | N | N | N | N | N |
| Red Hat Enterprise Linux 7.3 | Y | N | N | N | N | N | N | N | N | N | N | N | N |
| Red Hat Enterprise Linux 7.4 | Y | N | N | N | N | N | N | N | N | N | N | N | N |
| Red Hat Enterprise Linux 7.5 | Y | N | N | N | N | N | N | N | N | N | N | N | N |
| Red Hat Enterprise Linux 7.6 | Y | Y | Y | Y | N | Y | Y | Y | Y | Y | Y | Y | Y |
| Red Hat Enterprise Linux 7.7 | Y | Y | Y | Y | N | Y | Y | Y | Y | Y | Y | Y | Y |
| Red Hat Enterprise Linux 7.8 | Y | Y | Y | Y | N | Y | Y | Y | Y | Y | Y | Y | Y |
| Red Hat Enterprise Linux 7.9 | Y | Y | Y | Y | N | Y | Y | Y | Y | Y | Y | Y | Y |
| Red Hat Enterprise Linux 8.0 | Y | Y | Y | Y | N | Y | Y | Y | Y | Y | Y | Y | Y |
| Red Hat Enterprise Linux 8.1 | Y | Y | Y | Y | N | Y | Y | Y | Y | Y | Y | Y | Y |
| Red Hat Enterprise Linux 8.2 | Y | Y | Y | Y | N | Y | Y | Y | Y | Y | Y | Y | Y |
| Red Hat Enterprise Linux 8.3 | Y | Y | Y | Y | N | Y | Y | Y | Y | Y | Y | Y | Y |
| Red Hat Enterprise Linux 8.4 | Y | Y | Y | Y | N | Y | Y | Y | Y | Y | Y | Y | Y |
| Red Hat Enterprise Linux 8.5 | Y | Y | Y | Y | N | Y | Y | Y | Y | Y | Y | Y | Y |
| Red Hat Enterprise Linux 8.6 | Y | Y | Y | Y | N | Y | Y | Y | Y | Y | Y | Y | Y |
| SUSE Linux Enterprise Server 11 SP4 | Y | N | N | N | N | N | N | N | N | N | N | N | N |
| SUSE Linux Enterprise Server 11 SP4 with Xen | Y | N | N | N | N | N | N | N | N | N | N | N | N |
| SUSE Linux Enterprise Server 12 SP2 | Y | N | N | N | N | N | N | N | N | N | N | N | N |
| SUSE Linux Enterprise Server 12 SP2 with Xen | Y | N | N | N | N | N | N | N | N | N | N | N | N |
| SUSE Linux Enterprise Server 12 SP3 | Y | N | N | N | N | N | N | N | N | N | N | N | N |
| SUSE Linux Enterprise Server 12 SP3 with Xen | Y | N | N | N | N | N | N | N | N | N | N | N | N |
| SUSE Linux Enterprise Server 12 SP4 | Y | Y | Y | Y | N | Y | Y | Y | Y | Y | Y | Y | Y |
| SUSE Linux Enterprise Server 12 SP4 with Xen | Y | Y | Y | Y | N | Y | Y | Y | Y | Y | Y | Y | Y |
| SUSE Linux Enterprise Server 12 SP5 | Y | Y | Y | Y | N | Y | Y | Y | Y | Y | Y | Y | Y |
| SUSE Linux Enterprise Server 12 SP5 with Xen | Y | Y | Y | Y | N | Y | Y | Y | Y | Y | Y | Y | Y |
| SUSE Linux Enterprise Server 15 | Y | Y | Y | Y | N | Y | Y | Y | Y | Y | Y | Y | Y |
| SUSE Linux Enterprise Server 15 SP1 | Y | Y | Y | Y | N | Y | Y | Y | Y | Y | Y | Y | Y |
| SUSE Linux Enterprise Server 15 SP1 with Xen | Y | Y | Y | Y | N | Y | Y | Y | Y | Y | Y | Y | Y |
| SUSE Linux Enterprise Server 15 SP2 | Y | Y | Y | Y | N | Y | Y | Y | Y | Y | Y | Y | Y |
| SUSE Linux Enterprise Server 15 SP2 with Xen | Y | Y | Y | Y | N | Y | Y | Y | Y | Y | Y | Y | Y |
| SUSE Linux Enterprise Server 15 SP3 | Y | Y | Y | Y | N | Y | Y | Y | Y | Y | Y | Y | Y |
| SUSE Linux Enterprise Server 15 SP3 with Xen | Y | Y | Y | Y | N | Y | Y | Y | Y | Y | Y | Y | Y |
| SUSE Linux Enterprise Server 15 with Xen | Y | Y | Y | Y | N | Y | Y | Y | Y | Y | Y | Y | Y |
| Ubuntu 22.04 LTS or later with HWE kernel | Y | Y | Y | Y | N | Y | Y | Y | Y | Y | Y | Y | Y |
| VMware vSphere Hypervisor (ESXi) 6.0 U3 | Y | N | N | N | N | N | N | N | N | N | N | N | N |
| VMware vSphere Hypervisor (ESXi) 6.5 | Y | N | N | N | N | N | N | N | N | N | N | N | N |
| VMware vSphere Hypervisor (ESXi) 6.5 U1 | Y | N | N | N | N | N | N | N | N | N | N | N | N |
| VMware vSphere Hypervisor (ESXi) 6.5 U2 | Y | Y | Y | Y | N | Y | Y | Y | Y | Y | Y | Y | Y |
| VMware vSphere Hypervisor (ESXi) 6.5 U3 | Y | Y | Y | Y | N | Y | Y | Y | Y | Y | Y | Y | Y |
| VMware vSphere Hypervisor (ESXi) 6.7 | Y | N | N | N | N | N | N | N | N | N | N | N | N |
| VMware vSphere Hypervisor (ESXi) 6.7 U1 | Y | Y | Y | Y | N | Y | Y | Y | Y | Y | Y | Y | Y |
| VMware vSphere Hypervisor (ESXi) 6.7 U2 | Y | Y | Y | Y | N | Y | Y | Y | Y | Y | Y | Y | Y |
| VMware vSphere Hypervisor (ESXi) 6.7 U3 | Y | Y | Y | Y | N | Y | Y | Y | Y | Y | Y | Y | Y |
| VMware vSphere Hypervisor (ESXi) 7.0 | Y | Y | Y | Y | N | Y | Y | Y | Y | Y | Y | Y | Y |
| VMware vSphere Hypervisor (ESXi) 7.0 U1 | Y | Y | Y | Y | N | Y | Y | Y | Y | Y | Y | Y | Y |
| VMware vSphere Hypervisor (ESXi) 7.0 U2 | Y | Y | Y | Y | N | Y | Y | Y | Y | Y | Y | Y | Y |
| VMware vSphere Hypervisor (ESXi) 7.0 U3 | Y | Y | Y | Y | N | Y | Y | Y | Y | Y | Y | Y | Y |
1 1. This item is not a general stand-alone option for Lenovo ThinkSystem SD650 (Xeon SP Gen 2), M/T 7X58 (Xeon SP Gen 2). 2. For OS support matrix, pls refer to LeSI Best Recipe. 3. This item shall be installed/removed by Lenovo support rep only.
ThinkSystem M.2 with Mirroring Enablement Kit, 7Y37A01093
| Operating systems | SR950 (Xeon Gen 2) |
SR630 (Xeon Gen 1) |
SR650 (Xeon Gen 1) |
SR670 (Xeon Gen 1) |
SR670 (Xeon Gen 2) |
SR850 (Xeon Gen 1) |
SR850P (Xeon Gen 2) |
SR860 (Xeon Gen 1) |
SR950 (Xeon Gen 1) |
SR590 (Xeon Gen 1) |
ST550 (Xeon Gen 2) |
ST550 (Xeon Gen 2) |
ST550 (Xeon Gen 1) |
ST550 (Xeon Gen 1) |
SN550 (Xeon Gen 1) |
SN850 (Xeon Gen 1) |
SD650 (Xeon Gen 1) |
SD530 (Xeon Gen 1) |
SR570 (Xeon Gen 1) |
SR550 (Xeon Gen 1) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| For OS support info. please refer to LeSI Best Recipe. | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | Y 1 | N | N | N |
| Microsoft Windows Server 2012 R2 | N | Y | Y | N | N | Y | N | Y | Y | Y | N | N | Y | Y | Y | Y | N | Y | Y | Y |
| Microsoft Windows Server 2016 | Y | Y | Y | N | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
| Microsoft Windows Server 2019 | Y | Y | Y | N | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
| Microsoft Windows Server version 1709 | N | Y | Y | N | N | Y | N | Y | Y | Y | N | N | Y | Y | Y | Y | N | Y | Y | Y |
| Microsoft Windows Server version 1803 | N | Y | Y | N | N | Y | N | Y | Y | N | N | N | N | N | Y | N | N | Y | N | N |
| Red Hat Enterprise Linux 6.9 | N | Y | Y | N | N | Y | N | Y | Y | Y | N | N | Y | Y | Y | Y | N | Y | Y | Y |
| Red Hat Enterprise Linux 6.10 | N | Y | Y | N | N | Y | N | Y | Y | Y | N | N | Y | Y | Y | Y | N | Y | Y | Y |
| Red Hat Enterprise Linux 6 Server x64 Edition | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | Y |
| Red Hat Enterprise Linux 7.3 | N | Y | Y | N | N | Y | N | N | Y | N | N | N | Y | Y | Y | Y | N | Y | N | Y |
| Red Hat Enterprise Linux 7.4 | N | Y | Y | N | N | Y | N | Y | Y | Y | N | N | Y | Y | Y | Y | N | Y | Y | Y |
| Red Hat Enterprise Linux 7.5 | N | Y | Y | Y | Y | Y | N | Y | Y | Y | N | N | Y | Y | Y | Y | N | Y | Y | Y |
| Red Hat Enterprise Linux 7.6 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
| Red Hat Enterprise Linux 7.7 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
| Red Hat Enterprise Linux 7.8 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
| Red Hat Enterprise Linux 7.9 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
| Red Hat Enterprise Linux 8.0 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
| Red Hat Enterprise Linux 8.1 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
| Red Hat Enterprise Linux 8.2 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
| Red Hat Enterprise Linux 8.3 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
| Red Hat Enterprise Linux 8.4 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
| Red Hat Enterprise Linux 8.5 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
| Red Hat Enterprise Linux 8.6 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
| SUSE Linux Enterprise Server 11 SP4 | N | Y | Y | N | N | Y | N | Y | Y | Y | N | N | Y | Y | Y | Y | N | Y | Y | Y |
| SUSE Linux Enterprise Server 11 SP4 with Xen | N | Y | Y | N | N | Y | N | Y | Y | Y | N | N | Y | Y | Y | Y | N | Y | Y | Y |
| SUSE Linux Enterprise Server 12 SP2 | N | Y | Y | N | N | Y | N | N | Y | N | N | N | Y | Y | Y | Y | N | Y | N | Y |
| SUSE Linux Enterprise Server 12 SP2 with Xen | N | Y | Y | N | N | Y | N | N | Y | N | N | N | Y | Y | Y | Y | N | Y | N | Y |
| SUSE Linux Enterprise Server 12 SP3 | N | Y | Y | N | N | Y | Y | Y | Y | Y | N | N | Y | Y | Y | Y | N | Y | Y | Y |
| SUSE Linux Enterprise Server 12 SP3 with Xen | N | Y | Y | N | N | Y | Y | Y | Y | Y | N | N | Y | Y | Y | Y | N | Y | Y | Y |
| SUSE Linux Enterprise Server 12 SP4 | Y | Y | Y | N | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
| SUSE Linux Enterprise Server 12 SP4 with Xen | Y | Y | Y | N | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
| SUSE Linux Enterprise Server 12 SP5 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
| SUSE Linux Enterprise Server 12 SP5 with Xen | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
| SUSE Linux Enterprise Server 15 | Y | Y | Y | N | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
| SUSE Linux Enterprise Server 15 SP1 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
| SUSE Linux Enterprise Server 15 SP1 with Xen | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
| SUSE Linux Enterprise Server 15 SP2 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
| SUSE Linux Enterprise Server 15 SP2 with Xen | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
| SUSE Linux Enterprise Server 15 SP3 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
| SUSE Linux Enterprise Server 15 SP3 with Xen | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
| SUSE Linux Enterprise Server 15 with Xen | Y | Y | Y | N | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
| Ubuntu 22.04 LTS or later with HWE kernel | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
| VMware vSphere Hypervisor (ESXi) 6.0 U3 | N | Y | Y | N | N | Y | N | Y | Y | Y | N | N | Y | Y | Y | Y | N | Y | Y | Y |
| VMware vSphere Hypervisor (ESXi) 6.5 | N | Y | Y | N | N | Y | N | N | Y | N | N | N | Y | Y | Y | Y | N | Y | N | Y |
| VMware vSphere Hypervisor (ESXi) 6.5 U1 | N | Y | Y | N | N | Y | N | Y | Y | Y | N | N | Y | Y | Y | Y | N | Y | Y | Y |
| VMware vSphere Hypervisor (ESXi) 6.5 U2 | Y | Y | Y | N | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
| VMware vSphere Hypervisor (ESXi) 6.5 U3 | Y | Y | Y | N | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
| VMware vSphere Hypervisor (ESXi) 6.7 | N | Y | Y | N | N | Y | N | Y | Y | Y | N | N | Y | Y | Y | Y | N | Y | Y | Y |
| VMware vSphere Hypervisor (ESXi) 6.7 U1 | Y | Y | Y | N | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
| VMware vSphere Hypervisor (ESXi) 6.7 U2 | Y | Y | Y | N | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
| VMware vSphere Hypervisor (ESXi) 6.7 U3 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
| VMware vSphere Hypervisor (ESXi) 7.0 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
| VMware vSphere Hypervisor (ESXi) 7.0 U1 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
| VMware vSphere Hypervisor (ESXi) 7.0 U2 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
| VMware vSphere Hypervisor (ESXi) 7.0 U3 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
1 1. This item is not a general stand-alone option for Lenovo ThinkSystem SD650 (M/T 7X58). 2. For OS support matrix, pls refer to LeSI Best Recipe. 3. This Item shall be installed/removed by Lenovo support rep only.
| Operating systems | SR530 (Xeon Gen 1) |
SR850 (Xeon Gen 2) |
SR860 (Xeon Gen 2) |
SR570 (Xeon Gen 2) |
SD650 (Xeon Gen 2) |
SR650 (Xeon Gen 2) |
SR630 (Xeon Gen 2) |
SN850 (Xeon Gen 2) |
SN550 (Xeon Gen 2) |
SD530 (Xeon Gen 2) |
SR590 (Xeon Gen 2) |
SR550 (Xeon Gen 2) |
SR530 (Xeon Gen 2) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| For OS support info. please refer to LeSI Best Recipe. | N | N | N | N | Y 1 | N | N | N | N | N | N | N | N |
| Microsoft Windows Server 2012 R2 | Y | N | N | N | N | N | N | N | N | N | N | N | N |
| Microsoft Windows Server 2016 | Y | Y | Y | Y | N | Y | Y | Y | Y | Y | Y | Y | Y |
| Microsoft Windows Server 2019 | Y | Y | Y | Y | N | Y | Y | Y | Y | Y | Y | Y | Y |
| Microsoft Windows Server version 1709 | Y | N | N | N | N | N | N | N | N | N | N | N | N |
| Microsoft Windows Server version 1803 | N | N | N | N | N | N | N | N | N | N | N | N | N |
| Red Hat Enterprise Linux 6.9 | Y | N | N | N | N | N | N | N | N | N | N | N | N |
| Red Hat Enterprise Linux 6.10 | Y | N | N | N | N | N | N | N | N | N | N | N | N |
| Red Hat Enterprise Linux 6 Server x64 Edition | N | N | N | N | N | N | N | N | N | N | N | N | N |
| Red Hat Enterprise Linux 7.3 | Y | N | N | N | N | N | N | N | N | N | N | N | N |
| Red Hat Enterprise Linux 7.4 | Y | N | N | N | N | N | N | N | N | N | N | N | N |
| Red Hat Enterprise Linux 7.5 | Y | N | N | N | N | N | N | N | N | N | N | N | N |
| Red Hat Enterprise Linux 7.6 | Y | Y | Y | Y | N | Y | Y | Y | Y | Y | Y | Y | Y |
| Red Hat Enterprise Linux 7.7 | Y | Y | Y | Y | N | Y | Y | Y | Y | Y | Y | Y | Y |
| Red Hat Enterprise Linux 7.8 | Y | Y | Y | Y | N | Y | Y | Y | Y | Y | Y | Y | Y |
| Red Hat Enterprise Linux 7.9 | Y | Y | Y | Y | N | Y | Y | Y | Y | Y | Y | Y | Y |
| Red Hat Enterprise Linux 8.0 | Y | Y | Y | Y | N | Y | Y | Y | Y | Y | Y | Y | Y |
| Red Hat Enterprise Linux 8.1 | Y | Y | Y | Y | N | Y | Y | Y | Y | Y | Y | Y | Y |
| Red Hat Enterprise Linux 8.2 | Y | Y | Y | Y | N | Y | Y | Y | Y | Y | Y | Y | Y |
| Red Hat Enterprise Linux 8.3 | Y | Y | Y | Y | N | Y | Y | Y | Y | Y | Y | Y | Y |
| Red Hat Enterprise Linux 8.4 | Y | Y | Y | Y | N | Y | Y | Y | Y | Y | Y | Y | Y |
| Red Hat Enterprise Linux 8.5 | Y | Y | Y | Y | N | Y | Y | Y | Y | Y | Y | Y | Y |
| Red Hat Enterprise Linux 8.6 | Y | Y | Y | Y | N | Y | Y | Y | Y | Y | Y | Y | Y |
| SUSE Linux Enterprise Server 11 SP4 | Y | N | N | N | N | N | N | N | N | N | N | N | N |
| SUSE Linux Enterprise Server 11 SP4 with Xen | Y | N | N | N | N | N | N | N | N | N | N | N | N |
| SUSE Linux Enterprise Server 12 SP2 | Y | N | N | N | N | N | N | N | N | N | N | N | N |
| SUSE Linux Enterprise Server 12 SP2 with Xen | Y | N | N | N | N | N | N | N | N | N | N | N | N |
| SUSE Linux Enterprise Server 12 SP3 | Y | N | N | N | N | N | N | N | N | N | N | N | N |
| SUSE Linux Enterprise Server 12 SP3 with Xen | Y | N | N | N | N | N | N | N | N | N | N | N | N |
| SUSE Linux Enterprise Server 12 SP4 | Y | Y | Y | Y | N | Y | Y | Y | Y | Y | Y | Y | Y |
| SUSE Linux Enterprise Server 12 SP4 with Xen | Y | Y | Y | Y | N | Y | Y | Y | Y | Y | Y | Y | Y |
| SUSE Linux Enterprise Server 12 SP5 | Y | Y | Y | Y | N | Y | Y | Y | Y | Y | Y | Y | Y |
| SUSE Linux Enterprise Server 12 SP5 with Xen | Y | Y | Y | Y | N | Y | Y | Y | Y | Y | Y | Y | Y |
| SUSE Linux Enterprise Server 15 | Y | Y | Y | Y | N | Y | Y | Y | Y | Y | Y | Y | Y |
| SUSE Linux Enterprise Server 15 SP1 | Y | Y | Y | Y | N | Y | Y | Y | Y | Y | Y | Y | Y |
| SUSE Linux Enterprise Server 15 SP1 with Xen | Y | Y | Y | Y | N | Y | Y | Y | Y | Y | Y | Y | Y |
| SUSE Linux Enterprise Server 15 SP2 | Y | Y | Y | Y | N | Y | Y | Y | Y | Y | Y | Y | Y |
| SUSE Linux Enterprise Server 15 SP2 with Xen | Y | Y | Y | Y | N | Y | Y | Y | Y | Y | Y | Y | Y |
| SUSE Linux Enterprise Server 15 SP3 | Y | Y | Y | Y | N | Y | Y | Y | Y | Y | Y | Y | Y |
| SUSE Linux Enterprise Server 15 SP3 with Xen | Y | Y | Y | Y | N | Y | Y | Y | Y | Y | Y | Y | Y |
| SUSE Linux Enterprise Server 15 with Xen | Y | Y | Y | Y | N | Y | Y | Y | Y | Y | Y | Y | Y |
| Ubuntu 22.04 LTS or later with HWE kernel | Y | Y | Y | Y | N | Y | Y | Y | Y | Y | Y | Y | Y |
| VMware vSphere Hypervisor (ESXi) 6.0 U3 | Y | N | N | N | N | N | N | N | N | N | N | N | N |
| VMware vSphere Hypervisor (ESXi) 6.5 | Y | N | N | N | N | N | N | N | N | N | N | N | N |
| VMware vSphere Hypervisor (ESXi) 6.5 U1 | Y | N | N | N | N | N | N | N | N | N | N | N | N |
| VMware vSphere Hypervisor (ESXi) 6.5 U2 | Y | Y | Y | Y | N | Y | Y | Y | Y | Y | Y | Y | Y |
| VMware vSphere Hypervisor (ESXi) 6.5 U3 | Y | Y | Y | Y | N | Y | Y | Y | Y | Y | Y | Y | Y |
| VMware vSphere Hypervisor (ESXi) 6.7 | Y | N | N | N | N | N | N | N | N | N | N | N | N |
| VMware vSphere Hypervisor (ESXi) 6.7 U1 | Y | Y | Y | Y | N | Y | Y | Y | Y | Y | Y | Y | Y |
| VMware vSphere Hypervisor (ESXi) 6.7 U2 | Y | Y | Y | Y | N | Y | Y | Y | Y | Y | Y | Y | Y |
| VMware vSphere Hypervisor (ESXi) 6.7 U3 | Y | Y | Y | Y | N | Y | Y | Y | Y | Y | Y | Y | Y |
| VMware vSphere Hypervisor (ESXi) 7.0 | Y | Y | Y | Y | N | Y | Y | Y | Y | Y | Y | Y | Y |
| VMware vSphere Hypervisor (ESXi) 7.0 U1 | Y | Y | Y | Y | N | Y | Y | Y | Y | Y | Y | Y | Y |
| VMware vSphere Hypervisor (ESXi) 7.0 U2 | Y | Y | Y | Y | N | Y | Y | Y | Y | Y | Y | Y | Y |
| VMware vSphere Hypervisor (ESXi) 7.0 U3 | Y | Y | Y | Y | N | Y | Y | Y | Y | Y | Y | Y | Y |
1 1. This item is not a general stand-alone option for Lenovo ThinkSystem SD650 (Xeon SP Gen 2), M/T 7X58 (Xeon SP Gen 2). 2. For OS support matrix, pls refer to LeSI Best Recipe. 3. This item shall be installed/removed by Lenovo support rep only.
ThinkSystem SE350 M.2 Mirroring Enablement Kit, 4M17A60519
| Operating systems | SE350 |
|---|---|
| Microsoft Windows Server 2016 | Y 1 |
| Microsoft Windows Server 2019 | Y 1 |
| Microsoft Windows Server 2022 | Y |
| Red Hat Enterprise Linux 7.6 | Y 1 |
| Red Hat Enterprise Linux 7.7 | Y |
| Red Hat Enterprise Linux 7.8 | Y |
| Red Hat Enterprise Linux 7.9 | Y |
| Red Hat Enterprise Linux 8.1 | Y |
| Red Hat Enterprise Linux 8.2 | Y |
| Red Hat Enterprise Linux 8.3 | Y |
| Red Hat Enterprise Linux 8.4 | Y |
| Red Hat Enterprise Linux 8.5 | Y |
| Red Hat Enterprise Linux 8.6 | Y |
| Red Hat Enterprise Linux 9.0 | Y |
| SUSE Linux Enterprise Server 15 | Y 1 |
| SUSE Linux Enterprise Server 15 SP1 | Y |
| SUSE Linux Enterprise Server 15 SP1 with Xen | Y |
| SUSE Linux Enterprise Server 15 SP2 | Y |
| SUSE Linux Enterprise Server 15 SP2 with Xen | Y |
| SUSE Linux Enterprise Server 15 SP3 | Y |
| SUSE Linux Enterprise Server 15 SP3 with Xen | Y |
| SUSE Linux Enterprise Server 15 SP4 | Y |
| SUSE Linux Enterprise Server 15 SP4 with Xen | Y |
| SUSE Linux Enterprise Server 15 SP5 | Y |
| SUSE Linux Enterprise Server 15 SP5 with Xen | Y |
| SUSE Linux Enterprise Server 15 with Xen | Y 1 |
| VMware vSphere Hypervisor (ESXi) 6.5 U2 | Y 1 |
| VMware vSphere Hypervisor (ESXi) 6.7 U2 | Y 1 |
| VMware vSphere Hypervisor (ESXi) 6.7 U3 | Y |
| VMware vSphere Hypervisor (ESXi) 7.0 | Y |
| VMware vSphere Hypervisor (ESXi) 7.0 U1 | Y |
| VMware vSphere Hypervisor (ESXi) 7.0 U2 | Y |
| VMware vSphere Hypervisor (ESXi) 7.0 U3 | Y |
| VMware vSphere Hypervisor (ESXi) 8.0 | Y |
| VMware vSphere Hypervisor (ESXi) 8.0 U1 | Y |
| VMware vSphere Hypervisor (ESXi) 8.0 U2 | Y |
1 Failed to revert AK key funtion of ATP SEDs which are installed in Marvell dual boot drive.
ThinkSystem SE350 M.2 SATA 4-Bay Data RAID Mirroring Enablement Kit, 4M17A37606
| Operating systems | SE350 |
|---|---|
| Microsoft Windows Server 2016 | Y |
| Microsoft Windows Server 2019 | Y |
| Microsoft Windows Server 2022 | Y |
| Red Hat Enterprise Linux 7.6 | Y |
| Red Hat Enterprise Linux 7.7 | Y |
| Red Hat Enterprise Linux 7.8 | Y |
| Red Hat Enterprise Linux 7.9 | Y |
| Red Hat Enterprise Linux 8.1 | Y |
| Red Hat Enterprise Linux 8.2 | Y |
| Red Hat Enterprise Linux 8.3 | Y |
| Red Hat Enterprise Linux 8.4 | Y |
| Red Hat Enterprise Linux 8.5 | Y |
| Red Hat Enterprise Linux 8.6 | Y |
| Red Hat Enterprise Linux 9.0 | Y |
| SUSE Linux Enterprise Server 15 | Y |
| SUSE Linux Enterprise Server 15 SP1 | Y |
| SUSE Linux Enterprise Server 15 SP1 with Xen | Y |
| SUSE Linux Enterprise Server 15 SP2 | Y |
| SUSE Linux Enterprise Server 15 SP2 with Xen | Y |
| SUSE Linux Enterprise Server 15 SP3 | Y |
| SUSE Linux Enterprise Server 15 SP3 with Xen | Y |
| SUSE Linux Enterprise Server 15 SP4 | Y |
| SUSE Linux Enterprise Server 15 SP4 with Xen | Y |
| SUSE Linux Enterprise Server 15 SP5 | Y |
| SUSE Linux Enterprise Server 15 SP5 with Xen | Y |
| SUSE Linux Enterprise Server 15 with Xen | Y |
| VMware vSphere Hypervisor (ESXi) 6.5 U2 | Y |
| VMware vSphere Hypervisor (ESXi) 6.7 U2 | Y |
| VMware vSphere Hypervisor (ESXi) 7.0 | Y |
| VMware vSphere Hypervisor (ESXi) 7.0 U1 | Y |
| VMware vSphere Hypervisor (ESXi) 7.0 U2 | Y |
| VMware vSphere Hypervisor (ESXi) 7.0 U3 | Y |
| VMware vSphere Hypervisor (ESXi) 8.0 | Y |
| VMware vSphere Hypervisor (ESXi) 8.0 U1 | Y |
| VMware vSphere Hypervisor (ESXi) 8.0 U2 | Y |
Warranty
The M.2 adapters carry a one-year, customer-replaceable unit (CRU) limited warranty. When the adapters are installed in a supported server, the adapters assume the server’s base warranty and any warranty upgrades.
Related product families
Product families related to this document are the following:
- Drives
- RAID Adapters
Trademarks
Lenovo and the Lenovo logo are trademarks or registered trademarks of Lenovo in the United States, other countries, or both. A current list of Lenovo trademarks is available on the Web at https://www.lenovo.com/us/en/legal/copytrade/.
The following terms are trademarks of Lenovo in the United States, other countries, or both:
Lenovo®
ServerProven®
ThinkEdge®
ThinkSystem®
The following terms are trademarks of other companies:
AMD® and EPYC® are trademarks of Advanced Micro Devices, Inc.
Intel®, the Intel logo and Xeon® are trademarks of Intel Corporation or its subsidiaries.
Linux® is the trademark of Linus Torvalds in the U.S. and other countries.
Microsoft®, Windows 11™, Windows Server®, and Windows® are trademarks of Microsoft Corporation in the United States, other countries, or both.
ATP® is a trademark of IBM in the United States, other countries, or both.
Other company, product, or service names may be trademarks or service marks of others.