HPE Modular Power Distribution Units (Zero-U/1U Modular PDUs) |
|
|
|
HPE Modular PDUs have a unique modular architecture designed specifically for data center customers who want to maximize power distribution and space efficiencies in the rack. Modular PDUs consist of two building blocks - the Control Unit (core) and the optional Extension Bar(s) (sticks). The Control Unit is 1U/0U, and the optional Extension Bars mount directly to the frame of the rack in multiple locations. Available models range from 24A to 48A current ratings, with output connections ranging from four to six C-IEC C20 outlets. |
|
|
|
|
Models
|
North America, Japan, and South America (Except Argentina and Chile) | ||
|
200 - 240v 1Ø |
HPE Basic Modular 8.3kVA/CS8265C 40A/208V Outlets (4) C19/Horizontal NA/JP PDU |
252663-D75 |
|
HPE Basic Modular 4.9kVA/L6-30P 24A/208V Outlets (4) C19/Horizontal NA/JP Core Only PDU |
252663-D74 | |
|
200 - 240v 3Ø |
HPE Basic Modular 3Ph 8.6kVA/L15-30P 24A/208V Outlets (6) C19/Horizontal NA/JP PDU |
AF512A |
|
HPE Basic Modular 3Ph 14.4kVA/CS8365C 40A/208V Outlets (6) C19/Horizontal NA/JP PDU |
AF519A | |
|
HPE Basic Modular 3Ph 17.3kVA/60309 60A 4-wire 48A/208V Outlets (6) C19/Horizontal NA/JP PDU |
AF511A | |
|
|
|
|
|
International (Including Argentina and Chile) | ||
|
200 - 240v 1Ø |
HPE Basic Modular 9.2kVA/60309 63A 3-wire 40A/230V Outlets (4) C19/Horizontal INTL PDU |
252663-B34 |
|
HPE Basic Modular 7.3kVA/60309 3-wire 32A/230V Outlets (4) C19/Horizontal INTL Core Only PDU |
252663-B33 | |
|
380 - 415v 3Ø |
HPE Basic Modular 3Ph 11kVA/60309 5-wire 16A/230V Outlets (6) C19/Horizontal INTL PDU |
AF513A |
|
HPE Basic Modular 3Ph 22kVA/60309 5-wire 32A/230V Outlets (6) C19/Horizontal INTL PDU |
AF518A | |
|
| ||
|
* These Modular Distribution Units are "core only" and do not include any PDU extension bars. | ||
Standard Features
|
Features List |
|
|
| |
|
Key Features |
4.9 kVA to 9.2kVA1Ø models
8.6 kVA to 22 kVA 3Ø models
Easy installation in 1U or Zero U configurations |
|
| |
|
Unique Modular Design Architecture |
Modular PDUs have unique modular design architecture. This "Building block" concept consists of two main parts, the Control Unit, and the optional extension bar(s). . The Control Unit is zero-U or 1U rack mountable. Optional extension bars mount directly to the rack-frame.
3Ø Modular PDUs
|
|
| |
|
Easy Installation |
Installation is quick and easy. Whether you choose to mount the Modular PDU in zero-U or 1U, all required mounting brackets, accessories, and installation instructions are shipped with the product. |
|
| |
|
Compatibility |
Ideal for use with the HP10000 G2, 11000 G2, and Intelligent Series Racks, the Modular PDUs are largely designed for the dense rack environment. These Modular PDUs connect directly to the facility input power. |
|
| |
|
Warranty Upgrade Options |
HPE Modular PDUs are backed by a limited 3-year warranty. |
Service and Support
|
HPE Support Services |
Support services provide a range of life cycle support options that let you choose the service levels that meet your business requirements, from basic to mission-critical.
NOTE: Additional information regarding worldwide limited warranty and technical support is available at: http://h17007.www1.hpe.com/us/en/enterprise/servers/warranty/ |
|
| |
|
Parts and Materials |
Hewlett Packard Enterprise will provide HPE-supported replacement parts and materials necessary to maintain the covered hardware product in operating condition, including parts and materials for available and recommended engineering improvements. Parts and components that have reached their maximum supported lifetime and/or the maximum usage limitations as set forth in the manufacturer's operating manual, product quick-specs, or the technical product data sheet will not be provided, repaired, or replaced as part of these services. The defective media retention service feature option applies only to Disk or eligible SSD/Flash Drives replaced by Hewlett Packard Enterprise due to malfunction. |
Related Options
|
Related Options | ||
|
HPE Two C-13 PDU Extension Bars |
HPE Two C13 PDU Extension Bar |
AF500A |
|
HPE Two Fixed Cord Extension Bars |
HPE Fixed Cord Extension Bars |
351655-B21 |
|
HPE Support Services |
HP Install Rack and Rack Options Service |
U2871A |
|
HPE Install Rack and Rack Options Service |
U2871E | |
Modular PDU Family Information
|
Model Selection Matrix |
|
|
|
Core Only Modular PDUs |
|
|
4.9 kVA PDU |
7.3 kVA PDU |
8.3 kVA PDU |
9.2 kVA PDU |
8.6 kVA PDU |
11 kVA PDU |
14.4 kVA |
17.3kVA PDU |
22 kVA PDU |
|
Part Number |
252663-D74 |
252663-B33 |
252663-D75 |
252663-B34 |
AF512A |
AF513A |
AF519A |
HPE Basic Modular 3Ph 22kVA/60309 5-wire 32A/230V Outlets (6) C19/Horizontal INTL PDU |
AF518A |
|
Input Connection (Single Input) |
Input: 3.6m attached cable with L6-30P |
Input: 3.6m attached cable with IEC309-32A, Splash proof |
Input: 3.6m Attached Input cord, Non-NEMA Locking CS8265C, 50A |
Input: 3.6m Attached Input cord, IEC 60309 63A, Splash proof |
Input: 3.6m Attached input cord, NEMA L15-30P |
Input: 3.6m Attached Input cord, IEC 60309 4 pole, 5 wire, 380-415VAC, 16A, Splash proof |
Input: 3.6m Attached input cord, CS8365C plug |
Input 3.6m Attached Input cord IEC 60309 3 pole, 4 wire 200-240VAC 60A Waterproof |
Input: 3.6m Attached Input cord, IEC 60309 4 pole, 5 wire, 380-415VAC, 32A, Waterproof |
|
Facility power connection |
NEMA L6-30R |
IEC60309 2 pole, 3 wire, 200- 240VAC, 32A |
Non-NEMA CS8264C or CS8269, 50A or equivalent |
IEC60309 2 pole, 3 wire, 200- 240VAC, 63A |
208V 3 phase 3 pole 4 wire (Delta) NEMA L15-30R |
IEC60309 4 pole, 5 wire, 380-415 VAC, 16A |
208V 3 phase 3 pole 4 wire (Delta) CS8364C, CS8369, or equivalent |
IEC60309 3 pole, 4 wire, 208VAC 60A |
4 pole, 5 wire, 380-415 VAC, 32A |
|
Output Connections on Modular PDU core |
4 IEC 320 C-19 |
4 IEC 320 C-19 |
4 IEC 320 C-19 |
4 IEC 320 C-19 |
6 IEC 320 C-19 |
6 IEC 320 C-19 |
6 IEC 320 C-19 |
6 IEC 320 C-19 |
6 IEC 320 C-19 |
|
Current (max) |
24A |
32A |
40A |
40A |
41.52A |
16A |
69A |
83.04A |
32A phase |
|
AC Voltage Range |
200-240V |
200-240V |
200-240V |
200-240V |
208v 3Ø Delta |
380-415v 3Ø Wye |
208v 3Ø Delta |
208v 3Ø Delta |
380-415v 3Ø Wye |
|
Frequency (Hertz) |
50/60Hz |
50/60Hz |
50/60Hz |
50/60Hz |
50/60Hz |
50/60Hz |
50/60Hz |
50/60Hz |
50/60Hz |
|
Load Capacity (VA) |
4992 (@208V) |
7360 (@230V) |
8320 (@208V) |
9200 (@230V) |
8600 (@208V) |
11000 (@230v) |
14393 (@208V) |
17300 (@208V) |
22000 |
|
Output Circuit Breakers |
4x15A |
4x16A |
4x15A |
4x15A |
6 X 20A |
6 X 16A |
6 X 20A |
6 X 20A |
6 X 16A |
|
Overload Protection |
Yes, per load group |
Yes, per load group |
Yes, per load group |
Yes, per load group |
Yes, per load group |
Yes, per load group |
Yes, per load group |
Yes, per load group |
Yes, per load group |
|
|
|
|
|
|
HPE Power Cables |
Cable |
Description |
Part Number |
|
IEC C-13 |
4.5 ft (1.37 m), x15 |
HPE C13 - C14 WW 250V 10Amp 1.4m 15 pc Jumper Cord |
142257-007 |
|
4.5 ft (1.37 m), x1 |
HPE C13 - C14 WW 250V 10Amp 1.4m Jumper Cord |
142257-006 | |
|
1.6 ft (0.5m) x1 |
HPE C13 - C14 WW 250V 10Amp 0.7m Jumper Cord |
142257-B28 | |
|
8 ft (2.5m) x1 |
HPE C13 - C14 WW 250V 10Amp 2.5m Jumper Cord |
142257-002 | |
|
6 ft (1.83m) x1 |
HPE C13 - Nema 5-15P US/CA 110V 10Amp 1.83m Power Cord |
AF556A | |
|
|
|
|
|
|
IEC C-19 |
8 ft (2.5m) x 1 |
HPE C19 - C20 WW 250V 16Amp 2.5m Jumper Cord |
295633-B22 |
|
12 ft (3.66m) x1 |
HPE C19 - Nema L6-20P NA/JP 250V 20Amp High Voltage 3.6m Power Cord |
AF593A | |
|
Disclaimer: HPE makes no recommendations regarding power connector manufactures. The model numbers listed in the above tables are strictly for the purpose of providing examples. Please consult a licensed professional to determine the best connector or receptacle for your specific needs. | |||
Technical Specifications
|
All PDUs |
|
|
Shipping Weight |
20.2 lb (9.16 kg) |
|
Operating Temperature |
50° to 122° F (10° to 50° C) |
|
Operating Relative Humidity (%) |
10% to 90% |
|
Operating Elevation |
0 to 10,000 ft (0 to 3048 m) |
|
Storage Temperature |
-4° to 140° F (-20° to 60° C) |
|
Storage Relative Humidity (%) |
5% to 95% |
|
Storage Elevation |
0 to 30,000 ft (0 to 9144 m) |
|
Input Plug Length |
142 inches (360.7 cm) |
|
Conformance Standards |
UL, CUL, CE, NOM, D - 40A models |
|
1Ø 4.9kVA to 9.2kVA |
|
|
Mechanical Dimensions (WxHxD) |
17.46 x 1.66 x 6.00 in (44.34 x 4.21 x 15.24 cm) |
|
Unit Weight |
18 lb (8.16 kg) |
|
Shipping Dimensions (WxHxD) |
21.5 x 12.25 x 13.0 in (54.61 x 31.12 x 33.02 cm) |
|
3Ø 8.6 kVA to 22 kVA |
|
|
Mechanical Dimensions (WxHxD) |
17.5 x 1.62 x 7.5 in (44.45 x 4.11 x 19.22 cm) |
|
Unit Weight |
20 lb (9.07 kg) |
|
Shipping Dimensions (WxHxD) |
21.5 x 12.25 x 15.0 in (54.61 x 31.12 x 38.1 cm) |
|
Shipping Weight |
22.2 lb (10.07 kg) |
|
Kit Contents |
|
|
All Modular PDUs |
All models ship with: |
|
| |
|
Environment-friendly Products and Approach |
End-of-life Management and Recycling |
Hewlett Packard Enterprise offers end-of-life product return, trade-in, and recycling programs, in many geographic areas, for our products. Products returned to Hewlett Packard Enterprise will be recycled, recovered or disposed of in a responsible manner. http://www8.hp.com/us/en/hpe/hp-information/livingprogress/environmentalprogress/product-recycling.html#.V-lPA_krKiM The EU WEEE directive (2002/95/EC) requires manufacturers to provide treatment information for each product type for use by treatment facilities. This information (product disassembly instructions) is posted on the Hewlett Packard Enterprise web site. These instructions may be used by recyclers and other WEEE treatment facilities as well as HPE OEM customers who integrate and re-sell Hewlett Packard Enterprise equipment. http://www8.hp.com/us/en/hpe/hp-information/livingprogress/environmentalprogress/product-recycling.html#.V-lPA_krKiM |
Summary of Changes
|
Date |
Version History |
Action |
Description of Change | ||||||||||||||||||
|
23-Oct-2017 |
Version 28 |
Changed |
Care Pack naming and Service and Support- Parts and Materials updated. | ||||||||||||||||||
|
07-Oct-2016 |
From Version 26 to 27 |
Changed |
QuickSpecs was rebranded. | ||||||||||||||||||
|
29-Sep-2014 |
From Version 25 to 26 |
Changed |
Change made in the Technical Specifications section. | ||||||||||||||||||
|
30-Jul-2013 |
From Version 24 to 25 |
Removed |
EOL models were removed. | ||||||||||||||||||
|
17-Feb-2012 |
From Version 23 to 24 |
Changed |
Model Selection Matrix charts were revised. | ||||||||||||||||||
|
14-Sep-2011 |
From Version 22 to 23 |
Changed |
A Model description was revised. | ||||||||||||||||||
|
30-Aug-2011 |
From Version 21 to 22 |
Changed |
Model descriptions and HPE Two C-13 PDU Extension Bars in Related Options were revised Model Selection Matrix charts were updated | ||||||||||||||||||
|
20-Jun-2011 |
From Version 20 to 21 |
Changed |
Changes made throughout the QuickSpecs. | ||||||||||||||||||
|
04-Mar-2011 |
From Version 19 to 20 |
Changed |
Model Selection Matrix charts were revised. | ||||||||||||||||||
|
11-Sep-2009 |
From Version 18 to 19 |
Changed |
Changed a Note in the Modular PDU Family Information section. | ||||||||||||||||||
|
05-Feb-2009 |
From Version 17 to 18 |
Changed |
Changes affected the North America and Canada versions only. Just the date and version were changed in the Worldwide version. | ||||||||||||||||||
|
17-Nov-2008 |
From Version 16 to 17 |
Changed |
Changes made throughout the QuickSpecs. | ||||||||||||||||||
|
14-Nov-2008 |
From Version 15 to 16 |
Removed |
A note was removed from the Facility power connection row in the Model Selection Matrix. | ||||||||||||||||||
|
14-Jul-2008 |
From Version 14 to 15 |
Changed |
Changes made within the QuickSpecs include: | ||||||||||||||||||
|
|
|
|
Models range in the Overview section to 16A - 48A current ratings Part Number for IEC C-19 12ft Power Cable to AF593A in the Modular PDUs section 1 with 4 IEC 320 C-19 was removed from Extension Bars in the HPE Modular PDUs with Extension Bars Model section Description for the Input Connection of the Core Only Modular PDUs was changed to Waterproof instead of Splashproof AF511A and AF518A SKUs were added to the Technical Specifications section | ||||||||||||||||||
|
12-May-2008 |
From Version 13 to 14 |
Changed |
Changes made throughout the QuickSpecs except for the Service and Support section. | ||||||||||||||||||
|
05-Sep-2007 |
From Version 12 to 13 |
Added |
Added the Environment-friendly Products and Approach object to the Technical Specifications section. | ||||||||||||||||||
|
25-May-2007 |
From Version 11 to 12 |
Changed |
Changes made throughout the QuickSpecs. | ||||||||||||||||||
|
14-May-2007 |
From Version 10 to 11 |
Changed |
The QuickSpecs was rewritten. | ||||||||||||||||||
|
15-Dec-2006 |
From Version 9 to 10 |
Changed |
Changes made within the Product Highlights and Technical Specifications section only. | ||||||||||||||||||
|
27-Nov-2006 |
From Version 8 to 9 |
Changed |
Changes made throughout the Overview and Product Highlights sections | ||||||||||||||||||
|
29-Apr-2005 |
From Version 7 to 8 |
Added |
Added Model No.'s 252663-D75, 252663-B34, 252663-B33, and 252663-D74. | ||||||||||||||||||
|
01-Apr-2005 |
From Version 6 to 7 |
Changed |
Revised Technical Specs and Model Selection Matrix. | ||||||||||||||||||
|
|
|
Added |
Added Care Pack Hardware Installation P/N's. | ||||||||||||||||||
|
28-Jan-2005 |
From Version 5 to 6 |
Changed |
Changed 16A to 24A in the Model Selection Matrix Object in the Modular PDU Family section. | ||||||||||||||||||
|
01-Nov-2004 |
From Version 4 to 5 |
Changed |
The document was completely revised. | ||||||||||||||||||
|
02-Sep-2003 |
From Version 3 to 4 |
Changed |
Document was reformatted. | ||||||||||||||||||
|
11-Dec-2002 |
From Version 2 to 3 |
Changed |
Corrections were made throughout the various Specification Tables. | ||||||||||||||||||
|
19-Nov-2002 |
From Version 1 to 2 |
Changed |
This QuickSpecs was completely revised for this announcement. | ||||||||||||||||||
|
| |||||||||||||||||||||
| |||||||||||||||||||||