HPE Metered and Switched Power Distribution Units (PDU): технические характеристики и документация
В архивеOverview
|
HPE Metered and Switched Power Distribution Units (PDU) | |
|
| |
|
Looking for a power distribution unit that meets the demands of high temperature operating environments and provides monitoring and switching capabilities? The HPE Metered and Switched Power Distribution Unit (PDU) provides both local and remote power management for your IT racks. An advanced LCD screen provides local monitoring and alert indications, while remote access and configuration are available through secure Web, SNMP, CLI, or Telnet interfaces. Remote outlet monitoring offers ±1% billing grade accuracy while remote switching capabilities support power on/off functionality to remotely reboot equipment or restrict outlet usage. The PDU features a low-profile, single-piece design that provides multiple mounting options with ease of access to rear devices for maintenance. It is compatible with all HPE Advanced and Enterprise Series racks, as well as with many non-Hewlett Packard Enterprise racks using standard button and keyhole mounting. Multiple options are available supporting vertical/0U configurations with both single and 3-phase models. | |
|
|
|
|
Half Height Model (H8B49A shown) |
Full Height Model (H8B48A shown) |
|
|
|
|
Full Height Model (H8B50A & H8B51A shown) |
Full Height Model (H8B52A shown) |
|
|
|
|
Full Height Model (H8B53A shown) |
Full Height Model (H8B54A shown) |
|
|
|
|
|
|
|
Full Height Model (H8B55A & H8B56A shown) |
Models
|
Single Phase, Half Height (22U) |
|
|
HPE Metered Switched 3.6kVA/60320 C20 Detachable 16A/230V Outlets (7) C13 (1) C19/Vertical WW PDU |
H8B49A |
|
Single Phase, Full Height (42U) |
|
|
HPE Metered Switched 2.8kVA/L5-30P 24A/120V Outlets (24) 5-20R /Vertical NA/JP PDU |
H8B48A |
|
HPE Metered Switched 4.9kVA/L6-30P 24A/208V Outlets (20) C13 (4) C19/Vertical NA/JP PDU |
H8B50A |
|
HPE Metered Switched 7.3kVA/60309 3-wire 32A/230V Outlets (20) C13 (4) C19/Vertical INTL PDU |
H8B51A |
|
Three Phase, Full Height (42U) |
|
|
HPE Metered Switched 3Ph 8.6kVA/L15-30P 24A/208V Outlets (18) C13 (6) C19/Vertical NA/JP PDU |
H8B52A |
|
HPE Metered Switched 3Ph 8.6kVA/L2190-30P 24A/208V Outlets (23) C13 C19 (1) 520R/Vertical NA/JP PDU |
H8B53A |
|
HPE Metered Switched 3Ph 11kVA/60309 5-wire 16A/230V Outlets (21) C13 (3) C19/Vertical INTL PDU |
H8B54A |
|
HPE Metered Switched 3Ph 14.4kVA/CS8365C 40A/208V Outlets (12) C13 (12) C19/Vertical NA/JP PDU |
H8B55A |
|
HPE Metered Switched 3Ph 17.3kVA/60309 4-wire 48A/208V Outlets (12) C13 (12) C19/Vertical NA/JP PDU |
H8B56A |
Standard Features
|
Key Features |
Local and remote power distribution management with billing grade accuracy |
|
|
|
Flexible, simple installation and maintenance | |
|
|
|
Compatible With a Wide Range of Hewlett Packard Enterprise and Non-Hewlett Packard Enterprise Rack Solutions | |
|
|
|
| |
|
Billing Grade |
All HPE Metered and Switched Power Distribution Units (PDU) meet IEC 62053-21, Class 1 standards for ±1% or better accuracy in power monitoring of:
Accurate outlet and load segment power monitoring improves circuit utilization and provide information that can help balance power throughout the data center to maximize efficiency and cooling. |
|
| |
|
Remote Access |
|
|
| |
|
Flexible Installation |
The HPE Metered and Switched Power Distribution Units (PDU) are available in two form factors supporting a variety of vertical/0U rack configurations. All HPE Metered and Switched Power Distribution Units (PDU) can be mounted to stay completely out of the critical rear maintenance path needed to service IT equipment in the rack. All vertical models use industry standard button and keyhole mounting for simple drop in installation in HPE Advanced and Intelligent Series racks, as well as many non-Hewlett Packard Enterprise racks.
NOTE: Facing the outlets into the rack will interfere with the lower few rack U spaces of the rear maintenance zone due to breakers on the PDUs. |
|
| |
|
PDU Form Factors |
NOTE: When mounted in the standard rear facing configuration only 1 Full Height PDU can be mounted per side of the rack. Up to 2 Half Height PDUs can be mounted per side in the standard rear facing configuration in a 42U or taller rack. |
|
| |
|
Environmental monitoring |
An optional environmental sensor attaches to the HPE Metered and Switched Power Distribution Units (PDU) and can measure air temperature and humidity in the front or rear of the rack. The environmental sensor will send alerts over the network based on user defined thresholds. |
|
| |
|
Warranty |
HPE Metered and Switched Power Distribution Units (PDU) are backed by a limited 3-year warranty. |
Service and Support
|
HPE Support Services |
Support services provide a range of life cycle support options that let you choose the service levels that meet your business requirements, from basic to mission-critical.
NOTE: For more complete information on Hewlett Packard Enterprise Services offerings, customers and resellers, please visit us at: http://www.hp.com/hps |
Related Options
|
HPE Environmental |
HP Environmental Sensor for Remote Monitored and Managed PDUs |
E2D53A |
|
| |
|
NOTE: The HPE Environmental Sensor comes with a 6 foot RJ45-RJ45 cable and can be mounted in various locations within the rack using the supplied Velcro strips or mounting screw. RJ45 cables up to 30 feet (9.1m) long may be used. |
| |
|
| ||
|
HPE Country specific |
HP C19 - Nema L6-20P NA/JP 250V 20Amp High Voltage 3.6m Power Cord |
AF593A |
|
HP C19 - NBR-14136 BR 250V 16Amp 2.5m Power Cord |
AF592A | |
|
HP C19 - GB-1002 CN 250V 16Amp 2.5m Power Cord |
AF584A | |
|
HP C19 - IS-1293 IN/PK/BD 250V 16Amp 2.5m Power Cord |
AF582A | |
|
HP C19 - ISI-32 IL 250V 16Amp 2.5m Power Cord |
AF583A | |
|
HP C19 - AS3112-3 AU/NZ 250V 15Amp 3.6m Power Cord |
AF577A | |
|
HP C19 - IEC-309 DK/SE/AR 250V 16Amp 3.6m Power Cord |
AF581A | |
|
HP C19 - CEE-VII EU 250V 16Amp 3.6m Power Cord |
AF576A | |
|
HP C19 - CEI-23-50 IT/CL 250V 16Amp 3.6m Power Cord |
AF580A | |
|
HP C19 - SABS-164 ZA 250V 16Amp 3.6m Power Cord |
AF579A | |
|
HP C19 - BS-1363/A UK/HK/SG 250V 13Amp 3.6m Power Cord |
359615-031 | |
|
HP 240 VAC 4.5M Unterminated End NA Power Cord |
E7806A | |
|
| ||
|
HPE Jumper Cables |
HP C13 - C14 WW 250V 10A Gray 0.7m Jumper Cord |
A0K03A |
|
HP C13 - C14 WW 250V 10Amp 0.7m Jumper Cord |
142257-B28 | |
|
HP C13 - C14 WW 250V 10Amp 1.4m Jumper Cord |
142257-006 | |
|
HP C13 - C14 WW 250V 10A Gray 1.37m Jumper Cord |
A0K04A | |
|
HP C13 - C14 WW 250V 10Amp 1.4m 15 pc Jumper Cord |
142257-007 | |
|
HP C13 - C14 WW 250V 10Amp 2.0m Jumper Cord |
A0K02A | |
|
HP C13 - C14 WW 250V 10Amp Flint Gray 2.0m Jumper Cord |
AF573A | |
|
HP C13 - C14 WW 250V 10Amp 2.5m Jumper Cord |
142257-002 | |
|
HP C13 - C14 WW 250V 10Amp 3.0m Jumper Cord |
142257-003 | |
|
HP C13 - C14 WW 250V 10A Gray 3.0m Jumper Cord |
A0K06A | |
|
HP C20 - C13 WW 250V 15Amp 2.0m Jumper Cord |
AF590A | |
|
HP C19 - C20 WW 250V 16Amp Flint Gray 1.20m Jumper Cord |
AF575A | |
|
HP C19 - C20 WW 250V 16Amp Flint Gray 2.0m Jumper Cord |
AF574A | |
|
HP C19 - C20 WW 250V 16Amp 2.5m Jumper Cord |
295633-B22 | |
|
HP 200-250V 10A C15 to C14 .76m Jumper Cable |
E7807A | |
|
| ||
|
HPE Mounting Brackets |
HP Vertical PDU 10K G2 Mounting Kit |
H6L32A |
|
NOTE: Allows HPE Basic and Metered and Switched Power Distribution Units (PDU) vertical models to be mounted in HPE 10000 G2 series racks and in the HPE Basic Series rack. This bracket is not needed for mounting in the HPE Advanced or Enterprise Series racks. PDUs may interfere with the rear maintenance zone when using these brackets. |
| |
Model Selection Matrix
|
Half Height Vertical Models | |||||||
|
Model |
Part Number |
Input Voltage |
Current (Maximum) |
Load Capacity |
Input Connection |
Output Circuit Breaker |
Outlet Connections |
|
3.6kVA PDU |
H8B49A |
100-240V |
16A |
3680VA |
Detachable cord with IEC 320-C20 inlet |
N/A |
7 x IEC C13 |
|
NOTE: Model H8B49A includes an IEC320-C20 power inlet and does not include an inlet power cord. Customers may choose from multiple Hewlett Packard Enterprise country specific C19 PDU inlet cords that are listed in the “Related Options” section of this QuickSpecs. | |||||||
|
| |||||||
|
Full Height Vertical Models | |||||||
|
Model |
Part Number |
Input Voltage |
Current (Maximum) |
Load Capacity |
Input Connection |
Output Circuit Breaker |
Outlet Connections |
|
2.8kVA PDU |
H8B48A |
100-127V |
24A |
2880VA |
10ft(3m) cord with NEMA L5-30P |
2 x 20A |
24 x NEMA 5-20R |
|
4.9kVA PDU |
H8B50A |
200-240V |
24A |
4992VA |
10ft(3m) cord with NEMA L6-30P |
2 x 20A |
20 x IEC C13 |
|
7.3kVA PDU |
H8B51A |
200-240V |
32A |
7360 |
10ft(3m) cord with IEC 60309 32A 3-wire |
2 x 16A |
20 x IEC C13 |
|
8.6kVA PDU |
H8B52A |
200-240V |
24A |
8646VA |
10ft(3m) cord with NEMA L15-30P |
3 x 20A |
18 x IEC C13 |
|
8.6kVA PDU |
H8B53A |
120/208V |
24A |
8646VA |
10ft(3m) cord with NEMA L21-30P |
3 x 20A |
20 x IEC C13 |
|
11kVA PDU |
H8B54A |
200-240/ 346-415V |
16A |
11040VA |
10ft(3m) cord with IEC 60309 16A 5-wire |
N/A |
21 x IEC C13 |
|
14.4kVA PDU |
H8B55A |
200-240V |
40A |
14410VA |
10ft(3m) cord with |
6 x 20A |
12 x IEC C13 |
|
17.3kVA PDU |
H8B56A |
200-240V |
48A |
17292VA @ 208V |
10ft(3m) cord with IEC 60309 60A 4-wire Watertight |
6 x 20A |
12 x IEC C13 |
|
Disclaimer: Hewlett Packard Enterprise makes no recommendations regarding power connectors. Please consult a licensed professional to determine the best connector or receptacle for your specific needs. | |||||||
|
Voltage |
Amps |
# Wires |
Plug Name |
Sample Plug Image | |
|
100-125V Single Phase |
20 A |
3 |
NEMA L5-20P |
|
|
|
30 A |
3 |
NEMA L5-30P |
|
| |
|
200-240V Single Phase |
20 A |
3 |
IEC C20 |
|
|
|
20 A |
3 |
NEMA L6-20P |
|
| |
|
30 A |
3 |
NEMA L6-30P |
|
| |
|
32 A |
3 |
IEC 309 32A, 2Pole, 3Wire |
|
| |
|
20 A |
5 |
NEMA L21-20P |
|
| |
|
208V Three Phase
|
16 A |
5 |
IEC 309 16 A, 3Pole, 5Wire |
|
|
|
30 A |
5 |
NEMA L21-30P |
|
| |
|
50 A |
4 |
CS8365C |
|
| |
|
60 A |
4 |
IEC 309 60A, 3Pole, 4Wire |
|
| |
|
400 - 415V Three Phase |
32 A |
5 |
IEC 309 32 A, 3Pole, 5Wire |
|
|
Technical Specifications
|
Operational Temperature (NA and NA/JPN models) |
32° to 140° F (0° to 60° C) |
| |||
|
Operating Temperature (INTL and WW models) |
32° to 131° F (0° to 55° C) with an 8A maximum load/outlet |
| |||
|
Operating Relative Humidity (%) |
10% to 90% |
| |||
|
Operating Elevation |
0 to 10,000 ft (0 to 3048 m) |
| |||
|
Storage Temperature |
-4° to 140° F (-20° to 60° C) |
| |||
|
Storage Relative Humidity (%) |
5% to 95% |
| |||
|
Storage Elevation |
0 to 30,000 ft (0 to 9144 m) |
| |||
|
Input Plug Length (attached cord units) |
120 inches (304.8 cm) |
| |||
|
Conformance Standards |
NA/JPN models: UL or CSA, CB Test + FCC, ICES, VCCI |
| |||
|
Mechanical Dimensions (WxHxD) - Half Height model (H8B49A) |
2.05 x 35.5 x 2.09 in (5.2 x 90.2 x 5.3 cm) |
| |||
|
Mechanical Dimensions (WxHxD) - Full Height models (H8B50A/H8B51A/H8B53A/H8B54A) |
2.05 x 66.5 x 2.09 in (5.2 x 168.9 x 5.3 cm) |
| |||
|
Mechanical Dimensions (WxHxD) - Full Height models (H8B48A/H8B52A/H8B55A/H8B56A) |
2.05 x 66.5 x 2.56 in (5.2 x 168.9 x 6.5 cm) |
| |||
|
Unit Weight |
H8B48A: 11.55 lbs (5.24 kg); H8B49A: 4.06 lbs (1.84 kg); H8B52A: 13.74 lbs (6.23 kg); H8B53A: 13.23 lbs (6.00 kg) H8B54A: 10.14 lbs (4.60 kg); H8B55A: 21.91 lbs (9.94 kg); H8B56A: 23.08 lbs (10.47kg) |
| |||
|
Kit Contents - All Metered and Switched PDUs |
All models ship with:
|
| |||
|
|
| ||||
|
|
Environment-friendly Products and Approach |
End-of-life Management and Recycling |
Hewlett Packard Enterprise offers end-of-life Hewlett Packard Enterprise product return, trade-in, and recycling programs in many geographic areas. For trade-in information, please go to: http://www.hp.com/go/green. To recycle your product, please go to: http://www.hp.com/go/green or contact your nearest Hewlett Packard Enterprise sales office. Products returned to Hewlett Packard Enterprise will be recycled, recovered or disposed of in a responsible manner. | ||
|
Date |
Version History |
Action |
Description of Change | ||||||||||||||
|
16-Feb-2016 |
From Version 1 to 12 |
Changed |
Overview, Models, Standard Features, Service and Support, Related Options, Model Selection Matrix, and Technical Specifications were updated. Note the title changed to HPE Metered and Switched Power Distribution Units (PDU). | ||||||||||||||
|
| |||||||||||||||||
|
|
| |||||||||||||||
|
|
|
© Copyright 2016 Hewlett Packard Enterprise Development Company, L.P. The only warranties for Hewlett Packard Enterprise products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. Hewlett Packard Enterprise shall not be liable for technical or editorial errors or omissions contained herein. c04376673 - 15069 - Worldwide - V2 - 16-February-2016 | |||||||||||||||