Сегодня покупают
← Вернуться назад
Нужна помощь с конфигурацией?
Пришлите SKU, спецификацию или список требований. Специалист Apltech проверит совместимость компонентов и найдёт актуальные артикулы
Получить консультацию →

HP 6200 Switch Series: технические характеристики и документация

В архиве
HP 6200 yl Switch Series

Overview

HP 6200 yl Switch Series  (Retired)

 

 

 

 

Models

HP 6200-24G-mGBIC yl Switch

J8992A


 

Introduction

The HP 6200-24G-mGBIC yl Switch is an advanced Layer 3 stackable switch in 1U height. It has 24 mini-GBIC slots and an expansion slot for an optional 4-port 10GbE module.

Designed to be deployed as an aggregator of traffic from the edge to the core of the network, this switch supports a variety of Gigabit mini-GBICs, such as SX, LX, LH, and 1000BASE-T. The foundation for this switch is a purpose-built ProVision ASIC that allows the most demanding networking features, such as quality of service (QoS) and security, to be implemented in a scalable yet granular fashion. With its high-performance architecture, 10GbE capability, and programmable ASIC, this switch offers excellent investment protection, flexibility, and scalability.


 

Key features

  • Distribution layer
  • Layer 2 to 4 and intelligent edge feature set
  • High performance
  • Low-cost mini-GBIC connectivity
  • 10GbE uplinks

 

Features and Benefits

Software-defined networking

  • NEW OpenFlow
    supports OpenFlow 1.0 and 1.3 specifications to enable SDN by allowing separation of the data (packet forwarding) and control (routing decision) paths

Quality of Service (QoS)

  • Advanced classifier-based QoS
    classifies traffic using multiple match criteria based on Layer 2, 3, and 4 information; applies QoS policies such as setting priority level and rate limit to selected traffic on a per-port or per-VLAN basis
  • Layer 4 prioritization
    enables prioritization based on TCP/UDP port numbers
  • Traffic prioritization
    allows real-time traffic classification into eight priority levels mapped to eight queues
  • Bandwidth shaping:
    • Port-based rate limiting
      provides per-port ingress/egress enforced maximum bandwidth
    • Classifier-based rate limiting
      uses access control list (ACL) to enforce maximum bandwidth for ingress traffic on each port
    • Reduced bandwidth
      provides per-port, per-queue egress-based reduced bandwidth
  • Class of Service (CoS)
    sets the IEEE 802.1p priority tag based on IP address, IP Type of Service (ToS), Layer 3 protocol, TCP/UDP port number, source port, and DiffServ

Management

  • Remote intelligent mirroring
    mirrors selected ingress/egress traffic based on ACL, port, MAC address, or VLAN to a local or remote HP 8200 zl, 6600, 6200 yl, 5400 zl, or 3500 Switch located anywhere on the network
  • RMON, XRMON, and sFlow
    provide advanced monitoring and reporting capabilities for statistics, history, alarms, and events
  • IEEE 802.1AB Link Layer Discovery Protocol (LLDP)
    advertises and receives management information from adjacent devices on a network, facilitating easy mapping by network management applications
  • Command authorization
    leverages RADIUS to link a custom list of CLI commands to an individual network administrator's login; an audit trail documents activity
  • Friendly port names
    allow assignment of descriptive names to ports
  • Dual flash images
    provide independent primary and secondary operating system files for backup while upgrading
  • Multiple configuration files
    can be stored to the flash image
  • Uni-Directional Link Detection (UDLD)
    monitors a cable between two switches and shuts down the ports on both ends if the cable is broken, turning the bidirectional link into a unidirectional one; this prevents network problems such as loops
  • Management simplicity
    provides common software features and CLI implementation across all ProVision-based switches (including the zl and yl switches)
  • Comware-compatible CLI:
    • Comware-compatible CLI
      bridges the experience of HP Comware CLI users who are using the HP ProVision software CLI
    • Display and fundamental Comware CLI commands
      are embedded in the switch CLI as native commands; display output is formatted as on Comware-based switches, and fundamental commands provide a Comware-familiar initial switch setup
    • Configuration Comware CLI commands
      when Comware commands are entered, CLI help is elicited to formulate the correct ProVision software CLI command

Connectivity

  • Jumbo frames
    on Gigabit Ethernet and 10-Gigabit Ethernet ports, jumbo frames allow high-performance remote backup and disaster-recovery services
  • IPv6:
    • IPv6 host
      enables switches to be managed in an IPv6 network
    • Dual stack (IPv4 and IPv6)
      transitions from IPv4 to IPv6, supporting connectivity for both protocols
    • MLD snooping
      forwards IPv6 multicast traffic to the appropriate interface
    • IPv6 ACL/QoS
      supports ACL and QoS for IPv6 network traffic
    • IPv6 routing
      supports static and OSPFv3 routing protocols
    • 6in4 tunneling
      supports encapsulation of IPv6 traffic in IPv4 packets

Performance

  • High-speed/capacity architecture
    105.6 Gbps crossbar switching fabric provides intramodule and intermodule switching with 75.7 million pps throughput on the purpose-built ProVision ASICs
  • Selectable queue configurations
    allows for increased performance by selecting the number of queues and associated memory buffering that best meet the requirements of the network applications

Resiliency and high availability

  • NEW Virtual Router Redundancy Protocol (VRRP)
    allows groups of two routers to dynamically back each other up to create highly available routed environments in IPv4 and IPv6 networks
  • IEEE 802.1s Multiple Spanning Tree Protocol
    provides high link availability in multiple VLAN environments by allowing multiple spanning trees; encompasses IEEE 802.1D Spanning Tree Protocol and IEEE 802.1w Rapid Spanning Tree Protocol
  • IEEE 802.3ad Link Aggregation Control Protocol (LACP) and HP port trunking
    support up to 144 trunks, each with up to eight links (ports) per trunk
  • Distributed trunking
    enables loop-free and redundant network topology without using Spanning Tree Protocol; allows a server or switch to connect to two switches using one logical trunk for redundancy and load sharing
  • Uplink Failure Detection
    provides active-standby network path redundancy for servers that are configured for active-standby NIC teaming
  • NEW SmartLink
    provides easy-to-configure link redundancy of active and standby links

Layer 2 switching

  • IEEE 802.1ad Q-in-Q
    increases the scalability of an Ethernet network by providing a hierarchical structure; connects multiple LANs on a high-speed campus or metro network
  • HP switch meshing
    dynamically load balances across multiple active redundant links to increase available aggregate bandwidth
  • VLAN support and tagging
    supports complete IEEE 802.1Q standard and 2,048 VLANs simultaneously
  • IEEE 802.1v protocol VLANs
    isolate select non-IPv4 protocols automatically into their own VLANs
  • GARP VLAN Registration Protocol
    allows automatic learning and dynamic assignment of VLANs
  • Rapid Per-VLAN Spanning Tree (RPVST+)
    allows each VLAN to build a separate spanning tree to improve link bandwidth usage; is compatible with PVST+

Layer 3 services

  • User Datagram Protocol (UDP) helper function
    allows UDP broadcasts to be directed across router interfaces to specific IP unicast or subnet broadcast addresses and prevents server spoofing for UDP services such as DHCP
  • Loopback interface address
    defines an address in Routing Information Protocol (RIP) and Open Standard Path First (OSPF), improving diagnostic capability
  • Route map
    provide more control during route redistribution; allow filtering and altering of route metrics

Layer 3 routing

  • Static IP routing
    provides manually configured routing for both IPv4 and IPv6 networks
  • Routing Information Protocol (RIP)
    provides RIPv1 and RIPv2 routing
  • OSPF
    provides OSPFv2 for IPv4 routing and OSPFv3 for IPv6 routing
  • Border Gateway Protocol (BGP)
    provides IPv4 Border Gateway Protocol routing, which is scalable, robust, and flexible

Security

  • Switch CPU protection
    provides automatic protection against malicious network traffic trying to shut down the switch
  • Virus throttling
    detects traffic patterns typical of WORM-type viruses and either throttles or entirely prevents the virus from spreading across the routed VLANs without requiring external appliances
  • ICMP throttling
    defeats ICMP denial-of-service attacks by enabling any switch port to automatically throttle ICMP traffic
  • Multiple user authentication methods:
    • IEEE 802.1X users per port: provides authentication of multiple IEEE 802.1X users per port; prevents user "piggybacking" on another user's IEEE 802.1X authentication
    • Web-based authentication: authenticates from Web browser for clients that do not support IEEE 802.1X supplicant; customized remediation can be processed on an external Web server
    • MAC-based authentication: client is authenticated with the RADIUS server based on client's MAC address
    • Concurrent IEEE 802.1X, Web, and MAC authentication schemes per port: switch port will accept up to 32 sessions of IEEE 802.1X, Web, and MAC authentications
  • Access control lists (ACLs)
    provide filtering based on the IP field, source/destination IP address/subnet, and source/destination TCP/UDP port number on a per-VLAN or per-port basis
  • Identity-driven ACL
    enables implementation of a highly granular and flexible access security policy and VLAN assignment specific to each authenticated network user
  • DHCP protection
    blocks DHCP packets from unauthorized DHCP servers, preventing denial-of-service attacks
  • STP BPDU port protection
    blocks Bridge Protocol Data Units (BPDUs) on ports that do not require BPDUs, preventing forged BPDU attacks
  • Dynamic IP lockdown
    works with DHCP protection to block traffic from unauthorized hosts, preventing IP source address spoofing
  • Dynamic ARP protection
    blocks ARP broadcasts from unauthorized hosts, preventing eavesdropping or theft of network data
  • Detection of malicious attacks
    monitors 10 types of network traffic and sends a warning when an anomaly that potentially can be caused by malicious attacks is detected
  • Port security
    allows access only to specified MAC addresses, which can be learned or specified by the administrator
  • MAC address lockout
    prevents particular configured MAC addresses from connecting to the network
  • Source-port filtering
    allows only specified ports to communicate with each other
  • RADIUS/TACACS+
    eases switch management security administration by using a password authentication server
  • Secure Shell
    encrypts all transmitted data for secure remote CLI access over IP networks
  • Secure Sockets Layer (SSL)
    encrypts all HTTP traffic, allowing secure access to the browser-based management GUI in the switch
  • Secure FTP
    allows secure file transfer to and from the switch; protects against unwanted file downloads or unauthorized copying of a switch configuration file
  • Management Interface Wizard
    helps secure management interfaces such as SNMP, telnet, SSH, SSL, Web, and USB at the desired level
  • Secure management access
    securely encrypts all access methods (CLI, GUI, or MIB) through SSHv2, SSL, and/or SNMPv3
  • Switch management logon security
    can require either RADIUS or TACACS+ authentication for secure switch CLI logon
  • Security banner: displays customized security policy when users log in to the switch
  • USB Secure Autorun (requires HP PCM+)
    deploys, diagnoses, and updates a switch using a USB flash drive; works with a secure credential to prevent tampering
  • STP Root Guard
    protects the root bridge from malicious attacks or configuration mistakes

Convergence

  • IP multicast routing
    includes PIM Sparse and Dense modes to route IP multicast traffic
  • IP multicast snooping (data-driven IGMP)
    automatically prevents flooding of IP multicast traffic
  • LLDP-MED (Media Endpoint Discovery)
    is a standard extension of LLDP that stores values for parameters such as QoS and VLAN to automatically configure network devices such as IP phones
  • Auto VLAN configuration for voice:
    • RADIUS VLAN: uses a standard RADIUS attribute and LLDP-MED to automatically configure a VLAN for IP phones
    • CDPv2: uses CDPv2 to configure legacy IP phones
  • NEW Local MAC Authentication
    assigns attributes such as VLAN and QoS using locally configured profile that can be a list of MAC prefixes

Warranty and support

  • Lifetime Warranty 2.0
    advance hardware replacement for as long as you own the product with next-business-day delivery (available in most countries)†
  • Electronic and telephone support (for Lifetime Warranty 2.0)
    limited 24x7 telephone support is available from HP for the first 3 years; limited electronic and business hours telephone support is available from HP for the entire warranty period; to reach our support centers, refer to
    http://www.hp.com/networking/contact-support; for details on the duration of support provided with your product purchase, refer to www.hp.com/networking/warrantysummary
  • Software releases
    to find software for your product, refer to
    http://www.hp.com/networking/support; for details on the software
    releases available with your product purchase, refer to www.hp.com/networking/warrantysummary

†HP warranty includes repair or replacement of hardware for as long as you own the product, with next business day advance replacement (available in most countries). The disk drive included with HP AllianceOne Advanced Services and Services zl Modules, HP Threat Management Services zl Module, HP AllianceOne Extended zl Module with Riverbed Steelhead, HP MSM765zl Mobility Controller and HP Survivable Branch Communication zl Module powered by Microsoft Lync has a five-year hardware warranty. For details, refer to the Software license and hardware warranty statements at http://www.hp.com/networking/warranty.


Configuration

 

Build To Order:
BTO is a standalone unit with no integration. BTO products ship standalone are not part of a CTO or Rack-Shippable solution.

 

HP 6200-24G-mGBIC yl Switch

J8992A

  • 24 open mini-GBIC (SFP) slots
  • min=0 \ max=24 SFP Transceivers
  • 1U - Height

See Configuration Note:1, 2

 

 

PDU Cable NA/MEX/TW/JP

J8992A#B2B

  • C15 PDU Jumper Cord (NA/MEX/TW/JP)

 

 

PDU Cable ROW

J8992A#B2C

  • C15 PDU Jumper Cord (ROW)

 

 

 

Configuration Rules:

 

 

 

 

Note 1

The following Transceivers install into this switch:

 

HP X121 1G SFP LC SX Transceiver

J4858C

HP X121 1G SFP LC LX Transceiver

J4859C

HP X111 100M SFP LC FX Transceiver

J9054C

HP X121 1G SFP RJ45 T Transceiver

J8177C

HP X112 100M SFP LC BX-D Transceiver

J9099B

HP X112 100M SFP LC BX-U Transceiver

J9100B

HP X121 1G SFP LC LH Transceiver

J4860C

HP X122 1G SFP LC BX-D Transceiver

J9142B

HP X122 1G SFP LC BX-U Transceiver

J9143A

HP X131 10G X2 SC ER Transceiver

J8438A

HP X131 10G X2 SC SR Transceiver

J8436A

HP X131 10G X2 SC LR Transceiver

J8437A

HP X131 10G X2 SC LRM Transceiver

J9144A

 

 

 

Note 2

Localization required on orders without #B2B or #B2C options.

 

 

Remarks:

 

 

Drop down under power supply should offer the following options and results:
Switch/Router/Power Supply to PDU Power Cord - #B2B in North America, Mexico, Taiwan, and Japan or #B2C ROW. (Watson Default B2B or B2C for Rack Level CTO)
Switch/Router/Power Supply to Wall Power Cord - Localized Option (Watson Default for BTO and Box Level CTO)

 

 

Factory Racked Models

 

 

 

HP 6200-24G-mGBIC yl Switch

J8992A

  • 24 open mini-GBIC (SFP) slots
  • min=0 \ max=24 SFP Transceivers
  • 1U - Height

See Configuration Note:1, 2

 

 

Configuration Rules:

 

 

 

 

Note 1

The following Transceivers install into this switch:

 

HP X121 1G SFP LC SX Transceiver

J4858C

HP X121 1G SFP LC LX Transceiver

J4859C

HP X111 100M SFP LC FX Transceiver

J9054C

HP X121 1G SFP RJ45 T Transceiver

J8177C

HP X112 100M SFP LC BX-D Transceiver

J9099B

HP X112 100M SFP LC BX-U Transceiver

J9100B

HP X121 1G SFP LC LH Transceiver

J4860C

HP X122 1G SFP LC BX-D Transceiver

J9142B

HP X122 1G SFP LC BX-U Transceiver

J9143A

HP X131 10G X2 SC ER Transceiver

J8438A

HP X131 10G X2 SC SR Transceiver

J8436A

HP X131 10G X2 SC LR Transceiver

J8437A

HP X131 10G X2 SC LRM Transceiver

J9144A

 

 

 

Note 2

If this switch is factory installed in HP Universal Racks, Then the J9583A#0D1 is required.
AMS then J9583A#0D1is required.
EMEA then J9583A#0D1 is required.
APD, Japan and China then J9583A#0D1 is required.

CLIC Only - Allow the J9583AZ in all regions.

 

 

Enter the following menu selections as integrated to the CTO Model X server above if order is factory built.

 

 

Modules

 

 

 

System (std 0 // max=2) User Selection (min 0 / max=2) per Chassis

 

 

 

HP 10GbE 2-port SFP+/2-port CX4 yl Mod

J9312A

  • min=0 \ max=2 SFP Transceivers

See Configuration Note:1

 

 

HP 10GbE 2-port X2 / 2-port CX4 yl Module

J8694A

 

 

Configuration Rules:

 

 

 

 

Note 1

The following Transceivers install into this switch:

 

HP X121 1G SFP LC SX Transceiver

J4858C

HP X121 1G SFP LC LX Transceiver

J4859C

HP X111 100M SFP LC FX Transceiver

J9054C

HP X121 1G SFP RJ45 T Transceiver

J8177C

HP X112 100M SFP LC BX-D Transceiver

J9099B

HP X112 100M SFP LC BX-U Transceiver

J9100B

HP X121 1G SFP LC LH Transceiver

J4860C

HP X122 1G SFP LC BX-D Transceiver

J9142B

HP X122 1G SFP LC BX-U Transceiver

J9143A

HP X131 10G X2 SC ER Transceiver

J8438A

HP X131 10G X2 SC SR Transceiver

J8436A

HP X131 10G X2 SC LR Transceiver

J8437A

HP X131 10G X2 SC LRM Transceiver

J9144A

 

 

Transceivers

 

 

 

SFP Transceivers

 

 

 

HP X121 1G SFP LC SX Transceiver

J4858C

HP X121 1G SFP LC LX Transceiver

J4859C

HP X111 100M SFP LC FX Transceiver

J9054C

HP X121 1G SFP LC LH Transceiver

J4860C

HP X121 1G SFP RJ45 T Transceiver

J8177C

HP X122 1G SFP LC BX-D Transceiver

J9142B

HP X122 1G SFP LC BX-U Transceiver

J9143B

HP X112 100M SFP LC BX-D Transceiver

J9099B

HP X112 100M SFP LC BX-U Transceiver

J9100B

HP X131 10G X2 SC ER Transceiver

J8438A

HP X131 10G X2 SC SR Transceiver

J8436A

HP X131 10G X2 SC LR Transceiver

J8437A

HP X131 10G X2 SC LRM Transceiver

J9144A

 

 

Cables

 

 

 

Multi-Mode Cables

 

HP .5m Multi-mode OM3 LC/LC FC Cable

AJ833A

HP 1m Multi-mode OM3 LC/LC FC Cable

AJ834A

HP 2 m Multimode OM3 LC/LC FC Cable

AJ835A

HP 5 m Multimode OM3 LC/LC FC Cable

AJ836A

HP 15 m Multimode OM3 LC/LC FC Cable

AJ837A

HP 30 m Multimode OM3 LC/LC FC Cable

AJ838A

HP 50 m Multimode OM3 LC/LC FC Cable

AJ839A

HP Premier Flex LC/LC OM4 2f 1m Cbl

QK732A

HP Premier Flex LC/LC OM4 2f 2m Cbl

QK733A

HP Premier Flex LC/LC OM4 2f 5m Cbl

QK734A

HP Premier Flex LC/LC OM4 2f 15m Cbl

QK735A

HP Premier Flex LC/LC OM4 2f 30m Cbl

QK736A

HP Premier Flex LC/LC OM4 2f 50m Cbl

QK737A

 

 

Switch Options

 

 

 

Rack Mount kits

 

 

 

HP X410 1U Univ 4-post Rack Mnt Kit

J9583A

 

See Configuration Note:1, 2

 

 

Rack Shelf

AB469A

 

See Configuration Note:3

 

 

Configuration Rules:

 

 

 

Note 1

Default with switch.

 

 

Note 2

If this Mounting Kit is order with #0D1 then it integrates to the HP Universal Rack. (not the switch)

 

 

Note 3

This has existing rules that say 1 per 20 if 1U and 1 per 10 if its 3U or more. This rule is fine for ProCurve. Note: Both parts above are required to ship the 62xx Series Switches installed in a rack. Exceptions- The Shelf Kit (AB469A) may be removed if the Switch is supported underneath by a full depth Server of 3U height or greater mounted on fixed rails

 

Technical Specifications

 

HP 6200-24G-mGBIC yl Switch (J8992A)

I/O ports and slots

24 open mini-GBIC (SFP) slots
Supports a maximum of 4 10-GbE ports, with optional module

Physical characteristics

Dimensions

17.44(w) x 15.43(d) x 1.73(h) in
(44.3 x 39.2 x 4.4 cm) (1U height)

Weight

14.11 lb (6.4 kg)

Memory and processor

Processor

Freescale PowerPC 8540 @ 666 MHz, 4 MB flash, 256 MB DDR SDRAM

Mounting and enclosure

Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only

Performance

1000 Mb Latency

< 3.7 µs (FIFO 64-byte packets)

10 Gbps Latency

< 2.1 µs (FIFO 64-byte packets)

Throughput

up to 75.7 million pps

Routing/Switching capacity

101.8 Gb/s

Switch fabric speed

105.6 Gb/s

Routing table size

10000 entries (IPv4)

Environment

Operating temperature

32ºF to 131ºF (0ºC to 55ºC); 32°F to 104°F (40°C) when used with any X2 10-GbE

Operating relative humidity

15% to 95% @ 104ºF (40ºC), noncondensing

Non-operating/
Storage temperature

–40°F to 158°F (-40°C to 70°C)

Non-operating/
Storage relative humidity

15% to 95% at 149°F (65°C), noncondensing

Altitude

up to 15,000 ft (4.6 km)

Acoustic

Power: 55.1 dB; DIN 45635T.19 per ISO 7779

Electrical characteristics

Description

The switch automatically adjusts to any voltage between 100-127 and 200-240 V with either 50 or 60 Hz.

Maximum heat dissipation

829 BTU/hr (875 kJ/hr)

AC v oltage

100-127/200-240 VAC

Current

1.8/0.9 A

Power consumption

243 W

Frequency

50/60 Hz

Safety

CSA 22.2 No. 60950; UL 60950; IEC 60950; EN 60950

Emissions

FCC Class A; VCCI Class A; EN 55022/CISPR 22 Class A

Immunity

EN

EN 55024, CISPR 24

ESD

IEC 61000-4-2; 4 kV CD, 8 kV AD

Radiated

IEC 61000-4-3; 3 V/m

EFT/Burst

IEC 61000-4-4; 1.0 kV (power line), 0.5 kV (signal line)

Surge

IEC 61000-4-5; 1 kV/2 kV AC

Conducted

IEC 61000-4-6; 3 V

Power frequency magnetic field

IEC 61000-4-8; 1 A/m, 50 or 60 Hz

Voltage dips and interruptions

IEC 61000-4-11; >95% reduction, 0.5 period; 30% reduction, 25 periods

Harmonics

EN 61000-3-2, IEC 61000-3-2

Flicker

EN 61000-3-3, IEC 61000-3-3

Management

HP PCM+; HP PCM (included); command-line interface; Web browser; configuration menu; out-of-band management (serial RS-232C)

Notes

Supported 1G SFP transceivers are revision "B" or later (product number ends with the letter "B" or later; for example, J9142B, J8177C).

Services

3-year, 4-hour onsite, 13x5 coverage for hardware (U2855E)
3-year, 4-hour onsite, 24x7 coverage for hardware (U2856E)
3-year, 4-hour onsite, 24x7 coverage for hardware, 24x7 SW phone support and SW updates (U6304E)
3-year, 24x7 SW phone support, software updates (UE262E)
1-year, post-warranty, 4-hour onsite, 13x5 coverage for hardware (HR889E)
1-year, post-warranty, 4-hour onsite, 24x7 coverage for hardware (HR890E)
1-year, post-warranty, 4-hour onsite, 24x7 coverage for hardware, 24x7 software phone support (HR891E)
Installation with minimum configuration, system-based pricing (U4826E)
Installation with HP-provided configuration, system-based pricing (U4830E)
4-year, 4-hour onsite, 13x5 coverage for hardware (UR868E)
4-year, 4-hour onsite, 24x7 coverage for hardware (UR869E)
4-year, 4-hour onsite, 24x7 coverage for hardware, 24x7 software phone (UR870E)
4-year, 24x7 SW phone support, software updates (UR871E)
5-year, 4-hour onsite, 13x5 coverage for hardware (UR872E)
5-year, 4-hour onsite, 24x7 coverage for hardware (UR873E)
5-year, 4-hour onsite, 24x7 coverage for hardware, 24x7 software phone (UR874E)
5-year, 24x7 SW phone support, software updates (UR875E)
3 Yr 6 hr Call-to-Repair Onsite (UW356E)
4 Yr 6 hr Call-to-Repair Onsite (UW357E)
5 Yr 6 hr Call-to-Repair Onsite (UW358E)
1-year, 6 hour Call-To-Repair Onsite for hardware (HR893E)
1-year, 24x7 software phone support, software updates (HR892E)
1-year, 24x7 software phone support, software updates + Next Business Day Hardware Exchange (HS610E)
1-year, 24x7 software phone support, software updates + 4 hour hardware exchange (HS611E)
3-year, 24x7 software phone support, software updates + Next Business Day Hardware Exchange (HS612E)
3-year, 24x7 software phone support, software updates + 4 hour Hardware Exchange (HS613E)
4-year, 24x7 software phone support, software updates + Next Business Day Hardware Exchange (HS614E)
4-year, 24x7 software phone support, software updates + 4 hour Hardware Exchange (HS615E)
5-year, 24x7 software phone support, software updates + Next Business Day Hardware Exchange (HS616E)
5-year, 24x7 software phone support, software updates + 4 hour Hardware Exchange (HS617E)

Refer to the HP website at www.hp.com/networking/services for details on the service-level descriptions and product numbers. For details about services and response times in your area, please contact your local HP sales office.

Standards and protocols

BGP

RFC 1997 BGP Communities Attribute
RFC 2918 Route Refresh Capability
RFC 4271 A Border Gateway Protocol 4 (BGP-4)
RFC 4456 BGP Route Reflection: An Alternative to Full
Mesh Internal BGP (IBGP)
RFC 5492 Capabilities Advertisement with BGP-4

Device Management

RFC 1591 DNS (client)
HTML and telnet management

General Protocols

IEEE 802.1ad Q-in-Q
IEEE 802.1AX-2008 Link Aggregation
IEEE 802.1D MAC Bridges
IEEE 802.1p Priority
IEEE 802.1Q VLANs
IEEE 802.1s Multiple Spanning Trees
IEEE 802.1v VLAN classification by Protocol and Port
IEEE 802.1w Rapid Reconfiguration of Spanning Tree
IEEE 802.3ad Link Aggregation Control Protocol (LACP)
IEEE 802.3x Flow Control
RFC 768 UDP
RFC 783 TFTP Protocol (revision 2)
RFC 792 ICMP
RFC 793 TCP
RFC 826 ARP
RFC 854 TELNET
RFC 868 Time Protocol
RFC 951 BOOTP
RFC 1058 RIPv1
RFC 1350 TFTP Protocol (revision 2)
RFC 1519 CIDR
RFC 1542 BOOTP Extensions
RFC 2030 Simple Network Time Protocol (SNTP) v4
RFC 2131 DHCP
RFC 2453 RIPv2
RFC 2548 (MS-RAS-Vendor only)
RFC 3046 DHCP Relay Agent Information Option
RFC 3576 Ext to RADIUS (CoA only)
RFC 3768 VRRP
RFC 4675 RADIUS VLAN & Priority
UDLD (Uni-directional Link Detection)

IP Multicast

RFC 3376 IGMPv3 (host joins only)
RFC 3973 PIM Dense Mode
RFC 4601 PIM Sparse Mode

IPv6

RFC 1981 IPv6 Path MTU Discovery
RFC 2375 IPv6 Multicast Address Assignments
RFC 2460 IPv6 Specification
RFC 2464 Transmission of IPv6 over Ethernet Networks
RFC 2710 Multicast Listener Discovery (MLD) for IPv6
RFC 2925 Definitions of Managed Objects for Remote
Ping, Traceroute, and Lookup Operations (Ping only)
RFC 3019 MLDv1 MIB
RFC 3315 DHCPv6 (client and relay)
RFC 3484 Default Address Selection for IPv6
RFC 3587 IPv6 Global Unicast Address Format
RFC 3596 DNS Extension for IPv6
RFC 3810 MLDv2 for IPv6
RFC 3810 Multicast Listener Discovery Version 2
(MLDv2) for IPv6
RFC 4022 MIB for TCP
RFC 4087 IP Tunnel MIB
RFC 4113 MIB for UDP
RFC 4213 Basic Transition Mechanisms for IPv6 Hosts
and Routers
RFC 4251 SSHv6 Architecture
RFC 4252 SSHv6 Authentication
RFC 4253 SSHv6 Transport Layer
RFC 4254 SSHv6 Connection
RFC 4291 IP Version 6 Addressing Architecture
RFC 4293 MIB for IP
RFC 4294 IPv6 Node Requirements
RFC 4419 Key Exchange for SSH
RFC 4443 ICMPv6
RFC 4541 IGMP & MLD Snooping Switch
RFC 4861 IPv6 Neighbor Discovery
RFC 4862 IPv6 Stateless Address Auto-configuration
RFC 5095 Deprecation of Type 0 Routing Headers in IPv6
RFC 5340 OSPF for IPv6
RFC 5453 Reserved IPv6 Interface Identifiers
RFC 5519 Multicast Group Membership Discovery MIB
(MLDv2 only)
RFC 5722 Handling of Overlapping IPv6 Fragments

MIBs

IEEE 802.1ap (MSTP and STP MIB's only)
RFC 1213 MIB II
RFC 1493 Bridge MIB
RFC 1724 RIPv2 MIB
RFC 1850 OSPFv2 MIB
RFC 2021 RMONv2 MIB
RFC 2096 IP Forwarding Table MIB
RFC 2613 SMON MIB
RFC 2618 RADIUS Client MIB
RFC 2620 RADIUS Accounting MIB
RFC 2665 Ethernet-Like-MIB
RFC 2668 802.3 MAU MIB
RFC 2674 802.1p and IEEE 802.1Q Bridge MIB
RFC 2737 Entity MIB (Version 2)
RFC 2787 VRRP MIB
RFC 2863 The Interfaces Group MIB
RFC 2925 Ping MIB
RFC 2933 IGMP MIB

Network Management

IEEE 802.1AB Link Layer Discovery Protocol (LLDP)
RFC 2819 Four groups of RMON: 1 (statistics), 2 (history),
3 (alarm) and 9 (events)
RFC 3176 sFlow
ANSI/TIA-1057 LLDP Media Endpoint Discovery
(LLDP-MED)
SNMPv1/v2c/v3
XRMON

OSPF

RFC 2328 OSPFv2
RFC 3101 OSPF NSSA
RFC 5340 OSPF for IPv6

QoS/Cos

RFC 2474 DiffServ Precedence, including 8 queues/port
RFC 2597 DiffServ Assured Forwarding (AF)
RFC 2598 DiffServ Expedited Forwarding (EF)

Security

IEEE 802.1X Port Based Network Access Control
RFC 1492 TACACS+
RFC 2865 RADIUS (client only)
RFC 2866 RADIUS Accounting
RFC 3579 RADIUS Support For Extensible Authentication
Protocol (EAP)
Secure Sockets Layer (SSL)
SSHv2 Secure Shell

Accessories

 

HP 6200 yl Switch Series accessories

HP 6200-24G-mGBIC yl Switch (J8992A)

 

HP 10GbE 2-port SFP+ / 2-port CX4 yl Module

J9312A

HP 10GbE 2-port X2 / 2-port CX4 yl Module

J8694A

HP X131 10G X2 SC ER Transceiver

J8438A

HP X131 10G X2 SC SR Transceiver

J8436A

HP X131 10G X2 CX4 Transceiver

J8440C

HP X111 100M SFP LC FX Transceiver

J9054C

HP X131 10G X2 SC LR Transceiver

J8437A

HP X131 10G X2 SC LRM Transceiver

J9144A

HP X112 100M SFP LC BX-D Transceiver

J9099B

HP X112 100M SFP LC BX-U Transceiver

J9100B

HP X121 1G SFP LC LH Transceiver

J4860C

HP X121 1G SFP LC SX Transceiver

J4858C

HP X121 1G SFP LC LX Transceiver

J4859C

HP X121 1G SFP RJ45 T Transceiver

J8177C

HP X122 1G SFP LC BX-D Transceiver

J9142B

HP X122 1G SFP LC BX-U Transceiver

J9143B

HP LC to LC Multi-mode OM3 2-Fiber 0.5m 1-Pack Fiber Optic Cable

AJ833A

HP Premier Flex LC/LC Multi-mode OM4 2 fiber 1m Cable

QK732A

HP Premier Flex LC/LC Multi-mode OM4 2 fiber 2m Cable

QK733A

HP Premier Flex LC/LC Multi-mode OM4 2 fiber 5m Cable

QK734A

HP Premier Flex LC/LC Multi-mode OM4 2 fiber 15m Cable

QK735A

HP Premier Flex LC/LC Multi-mode OM4 2 fiber 30m Cable

QK736A

HP Premier Flex LC/LC Multi-mode OM4 2 fiber 50m Cable

QK737A

HP 620 Redundant/External Power Supply

J8696A


Accessory Product Details

 

HP 10GbE 2-port X2/2-port CX4 yl Module (J8694A)

Ports

2 open 10-GbE X2 transceiver slots
2 10-GbE ports (IEEE 802.3ak Type 10GBASE-CX4); Duplex: full only

Physical characteristics

Dimensions

7.76(d) x 7.52(w) x 14.29(h) in. (19.7 x 19.1 x 36.3 cm)

Weight

1.54 lb. (0.7 kg)

Environment

Operating temperature

32°F to 131°F (0°C to 55°C)

Operating relative humidity

15% to 95%, noncondensing

Nonoperating/Storage temperature

-40°F to 158°F (-40°C to 70°C)

Nonoperating/Storage relative humidity

15% to 90%, noncondensing

Cabling

Maximum distance:
• CX4: 15 m using CX4 cable or 300 m using media converter with ribbon MMF

Notes

Operating temperature is 32°F to 104°F (0°C to 40°C) if any X2 10-GbE optic or transceiver is inserted in any X2 slot.
One 0.5 m CX4 cable is included.

Services

Refer to the HP website at: http://www.hp.com/networking/services for details on the service-level descriptions and product numbers. For details about services and response times in your area, please contact your local HP sales office.


 

HP 10GbE 2-port SFP+/2-port CX4 yl Module (J9312A)

Ports

2 SFP+ 10-GbE ports (IEEE 802.3ae Type 10GBASE-LR); Duplex: full only
2 CX4 10-GbE ports (IEEE 802.3ak Type 10GBASE-CX4); Duplex: full only

Physical characteristics

Dimensions

7.76(d) x 7.52(w) x 14.29(h) in. (19.7 x 19.1 x 36.3 cm)

Weight

1.45 lb. (0.66 kg)

Environment

Operating temperature

32°F to 131°F (0°C to 55°C)

Operating relative humidity

15% to 95%, noncondensing

Nonoperating/Storage temperature

-40°F to 158°F (-40°C to 70°C)

Nonoperating/Storage relative humidity

15% to 90%, noncondensing

Cabling

Maximum distance:
• CX4: 15 m using CX4 cable or 300 m using media converter with ribbon MMF

Notes

Operating temperature is 32°F to 104°F (0°C to 40°C) if any SFP+ 10-GbE optic or transceiver is inserted in any SFP+ slot.
One 0.5 m CX4 cable is included.

Services

Refer to the HP website at: www.hp.com/networking/services for details on the service-level descriptions and product numbers. For details about services and response times in your area, please contact your local HP sales office.


 

HP 620 Redundant/External Power Supply (J8696A)

Ports

2 redundant power supply ports
Restrictions: 195 W available per port

2 external power supply ports
Restrictions: 398 W available per port

Physical characteristics

Dimensions

15.4(d) x 17.4(w) x 1.73(h) in. (39.12 x 44.2 x 4.39 cm) (1U height)

Weight

15.2 lb. (6.89 kg)

Mounting

Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only

Environment

Operating temperature

32°F to 131°F (0°C to 55°C)

Operating relative humidity

15% to 95% @ 104°F (40°C), noncondensing

Nonoperating/Storage temperature

-40°F to 158°F (-40°C to 70°C)

Nonoperating/Storage relative humidity

15% to 90% @ 149°F (65°C), noncondensing

Altitude

up to 10,000 ft. (3 km)

Acoustic

LwA per ISO 7779: 54.2 dB

Electrical characteristics

Maximum heat dissipation

400 BTU/hr (422 kJ/hr), for the actual 620 itself. PoE-powered device heat dissipation assumed to be outside the 620.

Voltage

100-127/200-240 VAC

Current

16/8 A

Maximum power rating

1440 W

RPS power

390 W

PoE power

796 W

RPS

12 V

PoE

-50 V

Frequency

50/60 Hz

Notes

Maximum power rating and maximum heat dissipation are the worst-case theoretical maximum numbers provided for planning the infrastructure with fully loaded PoE (if equipped), 100% traffic, all ports plugged in, and all modules populated.
Above figures are for maximum RPS and PoE power being supplied to two switches simultaneously. 200 - 240 V power cords shipped with the 620 have a wall plug rated as close to 13 A as specific country standards allow.

Safety

CSA 22.2 No. 60950; EN 60950/IEC 60950; UL 60950

Emissions

FCC Class A; VCCI Class A; EN 55022/CISPR 22 Class A

Immunity

EN

EN 55024, CISPR 24

ESD

IEC 61000-4-2

Radiated

IEC 61000-4-3

EFT/Burst

IEC 61000-4-4

Surge

IEC 61000-4-5

Conducted

IEC 61000-4-6

Power frequency magnetic field

IEC 61000-4-8

Voltage dips and interruptions

IEC 61000-4-11

Harmonics

EN 61000-3-2, IEC 61000-3-2

Flicker

EN 61000-3-3, IEC 61000-3-3

Management

Unmanaged power supply; provides information via LEDs (LEDs repeated on front and back panel) or through port interfaces of attached devices

Notes

The 620 supports the HP Switch 2900 Series (RPS) and 3500yl Series (RPS/PoE), as well as 6200yl (RPS) switches. The HP Switch 5400zl Series is not supported.
The 620 includes four 2 m RPS/EPS cables. These cables can be used to carry either RPS or PoE power to the switch being powered.

Services

3-year, 4-hour onsite, 13x5 coverage for hardware (U9270E)
3-year, 4-hour onsite, 24x7 coverage for hardware (U9271E)
4-year, 4-hour onsite, 13x5 coverage for hardware (UR854E)
4-year, 4-hour onsite, 24x7 coverage for hardware (UR855E)
5-year, 4-hour onsite, 13x5 coverage for hardware (UR857E)
5-year, 4-hour onsite, 24x7 coverage for hardware (UR858E)
3 Yr 6 hr Call-to-Repair Onsite (UW371E)
4 Yr 6 hr Call-to-Repair Onsite (UW372E)
5 Yr 6 hr Call-to-Repair Onsite (UW373E)

Refer to the HP website at:
http://www.hp.com/networking/services for details on the service-level descriptions and product numbers. For details about services and response times in your area, please contact your local HP sales office.


 

HP X131 10G X2 SC ER Transceiver (J8438A)

HP X131 10G X2 SC ER Transceiver: An X2 format
10-gigabit transceiver with SC connectors using ER
technology.

Ports

1 SC 10-GbE port (IEEE 802.3ae Type 10GBASE-ER); Duplex: full only

Connectivity

Connector type

SC

Wavelength

1550 nm

Physical characteristics

Dimensions

3.48(d) x 1.42(w) x 0.43(h) in. (8.84 x 3.61 x 1.09 cm)

Weight

0.35 lb. (0.16 kg)

Transceiver form factor

X2

Environment

Operating temperature

32ºF to 104ºF (0ºC to 40ºC)

Operating relative humidity

15% to 95%, noncondensing

Electrical characteristics

Power consumption typical

3 W

Power consumption maximum

4.5 W

Cabling

Cable type::
Low metal content, single-mode fiber-optic, complying with ITU-T G.652 and ISO/IEC 793-2 Type B1;

Cable length

2m to 30km (max 40km on engineered links)

Fiber type

Single Mode

Notes

Conditioning patch cord cables are not supported
For fiber patch cords, use Ultra Physical Contact (UPC) surface termination/polish. Angled Physical Contact (APC) is not recommended.

Services

Refer to the HP website at www.hp.com/networking/services for details on the service-level descriptions and product numbers. For details about services and response times in your area, please contact your local HP sales office.


 

HP X131 10G X2 SC SR Transceiver (J8436A)

HP X131 10G X2 SC SR Transceiver: An X2 format 10-gigabit transceiver with SC connectors using SR technology.

Ports

1 SC 10-GbE port (IEEE 802.3ae Type 10GBASE-SR); Duplex: full only

Connectivity

Connector type

SC

Wavelength

850 nm

Physical characteristics

Dimensions

3.48(d) x 1.42(w) x 0.43(h) in. (8.84 x 3.61 x 1.09 cm)

Weight

0.35 lb. (0.16 kg)

Transceiver form factor

X2

Environment

Operating temperature

32ºF to 158ºF (0ºC to 70ºC)

Operating relative humidity

0% to 95%, noncondensing

Nonoperating/Storage temperature

-40ºF to 185ºF (-40ºC to 85ºC)

Nonoperating/Storage relative humidity

0% to 95%, noncondensing

Altitude

up to 10,000 ft. (3 km)

Electrical characteristics

Power consumption typical

1.7 W

Power consumption maximum

2.4 W

Cabling

Cable type::
62.5/125 µm or 50/125 µm (core/cladding) graded-index, low metal content, multimode fiber optic, complying with ITU-T G.651 and ISO/IEC 793-2 Type A1b or A1a, respectively;

Maximum distance:

  • 2-26m with 62.5 µm multimode cable @ 160 MHz*km
  • 2-33m with 62.5 µm multimode cable @ 200 MHz*km
  • 2-66m with 50 µm multimode cable @ 400 MHz*km
  • 2-82m with 50 µm multimode cable @ 500 MHz*km
  • 2-300m with 50 µm multimode cable @ 2000 MHz*km

Cable length

2-300m

Fiber type

Multi Mode

Notes

For fiber patch cords, use Ultra Physical Contact (UPC) surface termination/polish. Angled Physical Contact (APC) is not recommended.

Services

Refer to the HP website at http://www.hp.com/networking/services for details on the service-level descriptions and product numbers. For details about services and response times in your area, please contact your local HP sales office.


 

HP X131 10G X2 CX4 Transceiver (J8440C)

HP X131 10G X2 CX4 Transceiver: An X2 format 10-gigabit CX4 transceiver.

Ports

1 CX4 10-GbE port (IEEE 802.3ak Type 10GBASE-CX4); Duplex: full only

Connectivity

Connector type

CX4

Physical characteristics

Dimensions

3.54(d) x 1.42(w) x 0.53(h) in. (8.99 x 3.61 x 1.35 cm)

Weight

0.18 lb. (0.08 kg)

Transceiver form factor

X2

Environment

Operating temperature

32ºF to 131ºF (0ºC to 55ºC)

Operating relative humidity

15% to 95%, noncondensing

Nonoperating/Storage temperature

-40ºF to 185ºF (-40ºC to 85ºC)

Altitude

up to 10,000 ft. (3 km)

Electrical characteristics

Power consumption typical

1.0 W

Power consumption maximum

3.3 W

Cabling

Maximum distance:
• 15m with CX4 cables
• 300m with optical media converter and multimode fiber cable

Notes

Connector: CX4; Duplex: full
For suggested vendors of CX4 cables, please see the "Cabling" answers on the "HP 10-GbE Transceivers" FAQs Web page.

Services

Refer to the HP website at www.hp.com/networking/services for details on the service-level descriptions and product numbers. For details about services and response times in your area, please contact your local HP sales office.


 

HP X111 100M SFP LC FX Transceiver (J9054C)

Ports

1 LC 100BASE-FX port (IEEE 802.3u Type 100BASE-FX); Duplex: half or full

Physical characteristics

Dimensions

2.7(d) x 0.54(w) x 0.48(h) in. (6.86 x 1.38 x 1.22 cm)

Weight

0.06 lb. (0.03 kg)

Environment

Operating temperature

32°F to 158°F (0°C to 70°C)

Operating relative humidity

5% to 95%

Nonoperating/Storage temperature

-40°F to 185°F (-40°C to 85°C)

Nonoperating/Storage relative humidity

5% to 85%

Altitude

up to 10,000 ft. (3 km)

Cabling

Cable type:
62.5/125 ìm or 50/125 ìm (core/cladding) diameter, graded-index, low metal content, multimode fiber optic, complying with ITU-T G.651 and ISO/IEC 793-2 Type A1b or A1a, respectively;
Maximum distance:
• 2 km (full duplex) or 412 m (half duplex)

Notes

Transmitter wavelength: 1310nm
Power consumption is 1.1 watt maximum.
For supported platforms and minimum software requirements to support this product, see the document titled "Support for the J9054C 100-FX SFP-LC Transceiver" on the "ProCurve Mini-GBICs and SFPs" Manuals Web page.

Services

Refer to the HP website at: http://www.hp.com/networking/services for details on the service-level descriptions and product numbers. For details about services and response times in your area, please contact your local HP sales office.


 

HP X131 10G X2 SC LR Transceiver (J8437A)

An X2 form-factor transceiver that supports the 10-Gigabit LR standard, providing 10-Gigabit connectivity up to 10 km on single-mode fiber.

Ports

1 SC 10-GbE port (IEEE 802.3ae Type 10GBASE-LR); Duplex: full only

Connectivity

Connector type

SC

Wavelength

1310 nm

Physical characteristics

Dimensions

3.48(d) x 1.42(w) x 0.43(h) in. (8.84 x 3.61 x 1.09 cm)

Weight

0.35 lb. (0.16 kg)

Transceiver form factor

X2

Environment

Operating temperature

32ºF to 104ºF (0ºC to 40ºC)

Operating relative humidity

15% to 95%, noncondensing

Nonoperating/Storage temperature

-40ºF to 185ºF (-40ºC to 85ºC)

Altitude

up to 10,000 ft. (3 km)

Electrical characteristics

Power consumption typical

2 W

Power consumption maximum

3 W

Cabling

Cable type::
Low metal content, single-mode fiber-optic, complying with ITU-T G.652 and ISO/IEC 793-2 Type B1;

Maximum distance:

  • 10 km

Cable length

2m to 10km with 9/125 ìm single-mode cable

Fiber type

Single Mode

Notes

Conditioning patch cord cables are not supported
For fiber patch cords, use Ultra Physical Contact (UPC) surface termination/polish. Angled Physical Contact (APC) is not recommended

Services

Refer to the HP website at www.hp.com/networking/services for details on the service-level descriptions and product numbers. For details about services and response times in your area, please contact your local HP sales office.


 

HP X131 10G X2 SC LRM Transceiver (J9144A)

An X2 form-factor transceiver that supports the 10-Gigabit LRM standard, providing 10-Gigabit connectivity up to 220 m on legacy multimode fiber.

Ports

1 SC 10-GbE port (IEEE 802.3aq Type 10GBASE-LRM); Duplex: full only

Physical characteristics

Dimensions

3.54(d) x 1.59(w) x 0.7(h) in. (9.0 x 4.05 x 1.78 cm)

Weight

0.35 lb. (0.16 kg)

Transceiver form factor

X2

Environment

Operating temperature

32ºF to 158ºF (0ºC to 70ºC)

Operating relative humidity

0% to 95%, noncondensing

Nonoperating/Storage temperature

-40ºF to 185ºF (-40ºC to 85ºC)

Altitude

up to 10,000 ft. (3 km)

Electrical characteristics

Power consumption typical

3.2 W

Power consumption maximum

4.2 W

Cabling

Cable type:
62.5/125 µm or 50/125 µm (core/cladding) diameter, graded-index, low metal content, multimode fiber optic, complying with ITU-T G.651 and ISO/IEC 793-2 Type A1b or A1a, respectively (a mode conditioning patch cord may be needed in some multimode fiber installations);

Maximum distance:
• 0.5-220m with 62.5 µm multimode cable @ 160/500 MHz*km
• 0.5-220m with 62.5 µm multimode cable @ 200/500 MHz*km
• 0.5-100m with 50 µm multimode cable @ 400/400 MHz*km
• 0.5-220m with 50 µm multimode cable @ 500/500 MHz*km
• 0.5-220m with 50 µm multimode cable @ 1500/500 MHz*km

Cable length

.5m to 220m

Fiber type

Multi Mode

Notes

Wavelength: 1310nm
For OM3 cable (50 ìm multimode @ 1500/500 MHz*km), a mode-conditioning patch cord is not required. Other multimode cables may require mode-conditioning patch cords to achieve the maximum distances listed above.
For supported platforms and minimum software requirements to support this product, see the document titled "Support for the J9144A 10-GbE X2-SC LRM Optic" on the "HP 10-GbE Transceivers" Manuals Web page.
Power Consumption: 4W Max

Services

Refer to the HP website at http://www.hp.com/networking/services for details on the service-level descriptions and product numbers. For details about services and response times in your area, please contact your local HP sales office.


 

HP X112 100M SFP LC BX-D Transceiver (J9099B)

A small form-factor pluggable (SFP) 100-Megabit BX (bi-directional) "downstream" transceiver that provides 100 Mbps full-duplex connectivity up to 10 km on one strand of singlemode fiber. The J9099B connects to the J9100B "upstream" transceiver, or to any IEEE-standard 100BASE-BX10-U ("upstream") device.

Ports

1 LC 100BASE-BX10 port (IEEE 802.3ah Type 100BASE-BX10-D); Duplex: full only

Physical characteristics

Dimensions

2.7(d) x 0.55(w) x 0.48(h) in. (6.86 x 1.39 x 1.22 cm)

Weight

0.04 lb. (0.03 kg)

Environment

Operating temperature

32ºF to 158ºF (0ºC to 70ºC)

Operating relative humidity

0% to 95%, noncondensing

Nonoperating/Storage temperature

-40ºF to 185ºF (-40ºC to 85ºC)

Cabling

Type:

Single-mode fiber optic, complying with ITU-T G.652;

Maximum distance:

  • 0.5-10,000 m (single-mode fiber)

Notes

Transmit wavelength: 1550 nm. Receive wavelength: 1310 nm.
Power consumption is 1.1 watt maximum.
For supported platforms and minimum software requirements to support this product, see the document titled "Support for the HP BX Transceivers" on the "HP Mini-GBICs and SFPs" Manuals Web page.
The J9099B connects to the J9100B "upstream" transceiver, or to any IEEE-standard 100BASE-BX10-U ("upstream") device. (A 100-BX-D transceiver can only connect to a 100-BX-U product. You cannot connect two 100-BX-D transceivers together.)

Services

Refer to the HP website at www.hp.com/networking/services for details on the service-level descriptions and product numbers. For details about services and response times in your area, please contact your local HP sales office.


 

HP X112 100M SFP LC BX-U Transceiver (J9100B)

A small form-factor pluggable (SFP) 100-Megabit BX (bi-directional) "upstream" transceiver that provides 100 Mbps full-duplex connectivity up to 10 km on one strand of singlemode fiber. The J9100B connects to the J9099B "downstream" transceiver, or to any IEEE-standard 100BASE-BX10-D ("downstream")
device.

Ports

1 LC 100BASE-BX10 port (IEEE 802.3ah Type 100BASE-BX10-U); Duplex: full only

Physical characteristics

Dimensions

2.7(d) x 0.55(w) x 0.48(h) in. (6.86 x 1.39 x 1.22 cm)

Weight

0.07 lb. (.03 kg)

Environment

Operating temperature

32ºF to 158ºF (0ºC to 70ºC)

Operating relative humidity

0% to 95%, noncondensing

Nonoperating/Storage temperature

-40ºF to 185ºF (-40ºC to 85ºC)

Cabling

Type:

Single-mode fiber optic, complying with ITU-T G.652;

Maximum distance:

  • 0.5-10,000 m (single-mode fiber)

Notes

For supported platforms and minimum software requirements to support this product, see the document titled "Support for the HP BX Transceivers" on the "HP Mini-GBICs and SFPs" Manuals Web page.
The J9100B connects to the J9099B "downstream" transceiver, or to any IEEE-standard 100BASE-BX10- D ("downstream") device. (A 100-BX-U transceiver can only connect to a 100-BX-D product. You cannot connect two 100-BX-U transceivers together.)
Transmit wavelength: 1310 nm. Receive wavelength: 1550 nm.
Power consumption is 1.1 watts maximum.

Services

Refer to the HP website at http://www.hp.com/networking/services for details on the service-level descriptions and product numbers. For details about services and response times in your area, please contact your local HP sales office.


 

HP X121 1G SFP LC LH Transceiver (J4860C)

A small form-factor pluggable (SFP) Gigabit LH transceiver that provides a full-duplex Gigabit solution up to 70 km on single-mode fiber.

Ports

1 LC 1000BASE-LH port (no IEEE standard exists for 1550 nm optics); Duplex: full only

Physical characteristics

Dimensions: 2.17(d) x 0.60(w) x 0.46(h) in. (5.5 x 1.53 x 1.18 cm)
Weight: 0.04 lb. (0.02 kg)

Environment

Operating temperature: -40°F to 185°F (-40°C to 85°C)

Operating relative humidity: 0% to 95% @ 77°F (25°C), noncondensing

Nonoperating/Storage temperature: -40°F to 185°F (-40°C to 85°C)

Altitude: up to 10,000 ft. (3 km)

Cabling

Cable type:

  • Low metal content, single-mode fiber-optic, complying with ITU-T G.652 and ISO/IEC 793-2 Type B1;

Maximum distance:

  • 10-70,000 m (single-mode fiber)

Notes

Power consumption is 0.8 watts typical with 1 watt maximum at 100% utilization.
For distances less than 20 km, a 10 dB attenuator must be used.
For distances between 20 km and 40 km, a 5 dB attenuator must be used.
Attenuators can be purchased from most cable vendors.

Services

Refer to the HP website at www.hp.com/networking/services for details on the service-level descriptions and product numbers. For details about services and response times in your area, please contact your local HP sales office.


 

HP X121 1G SFP LC SX Transceiver (J4858C)

A small form-factor pluggable (SFP) Gigabit SX
transceiver that provides a full-duplex Gigabit solution
up to 550 m on multimode fiber.

Ports

1 LC 1000BASE-SX port; Duplex: full only

Physical characteristics

Dimensions: 2.24(d) x 0.54(w) x 0.48(h) in. (5.69 x 1.37 x 1.22 cm)
Weight: 0.04 lb. (0.02 kg)
Transceiver form factor: SFP

Environment

Operating temperature: 32°F to 158°F (0°C to 70°C)

Operating relative humidity: 5% to 85%, noncondensing

Nonoperating/Storage temperature: -40°F to 203°F (-40°C to 85°C)

Altitude: up to 10,000 ft. (3 km)

Electrical characteristics

Power consumption typical: 0.4 W

Power consumption maximum: 0.7 W

Cabling

Type:

  • 62.5/125 µm or 50/125 µm (core/cladding) diameter, graded-index, low metal content, multimode fiber optic, complying with ITU-T G.651 and ISO/IEC 793-2 Type A1b or A1a, respectively;

Maximum distance:

  • 2-220 m (62.5 µm core diameter, 160 MHz*km bandwidth
  • 2-275 m (62.5 µm core diameter, 200 MHz*km bandwidth
  • 2-500 m (50 µm core diameter, 400 MHz*km bandwidth)
  • 2-550 m (50 µm core diameter, 500 MHz*km bandwidth)

 

Cable length: 2-550m

 

Fiber type: Multi Mode

Services

Refer to the HP website at http://www.hp.com/networking/services for details on the service-level descriptions and product numbers. For details about services and response times in your area, please contact your local HP sales office.


 

HP X121 1G SFP LC LX Transceiver (J4859C)

HP X121 1G SFP LC LX Transceiver: An SFP format
gigabit transceiver with LC connectors using LX
technology.

Ports

1 LC 1000BASE-LX port (IEEE 802.3z Type 1000BASE-LX); Duplex: full only

Physical characteristics

Dimensions: 2.24(d) x 0.54(w) x 0.486(h) in. (5.69 x 1.37 x 1.23 cm)
Weight:0.04 lb. (0.02 kg)

Environment

Operating temperature: 32°F to 158°F (0°C to 70°C)

Operating relative humidity: 0% to 85%, noncondensing

Nonoperating/Storage temperature: -40°F to 212°F (-40°C to 100°C)

Altitude: up to 10,000 ft. (3 km)

Cabling

Type:

  • Either single mode or multimode; 62.5/125 µm or 50/125 µm (core/cladding) diameter, graded-index, low metal content, multimode fiber optic, complying with ITU-T G.651 and ISO/IEC 793-2 Type A1b or A1a, respectively; Low metal content, single-mode fiber-optic, complying with ITU-T G.652 and ISO/IEC 793-2 Type B1;

Maximum distance:

  • 2-550 m (multimode 62.5 µm core diameter, 500 MHz*km bandwidth)
  • 2-550 m (multimode 50 µm core diameter, 400 MHz*km bandwidth)
  • 2-550 m (multimode 50 µm core diameter, 500 MHz*km bandwidth)
  • 2-10,000 m (single-mode fiber)

Notes

A mode conditioning patch cord may be needed in some multimode fiber installations.
Wavelength: 1310nm
Power Consumption: < 500mW Typical

Services

Refer to the HP website at www.hp.com/networking/services for details on the service-level descriptions and product numbers. For details about services and response times in your area, please contact your local HP sales office.


 

HP X122 1G SFP LC BX-D Transceiver (J9142B)

A small form-factor pluggable (SFP) Gigabit-BX (bi-directional) "downstream" transceiver that provides a full-duplex Gigabit solution up to 10 km on one strand of single-mode fiber. The J9142B connects to the J9143B "upstream" transceiver, or to any IEEE-standard 1000BASE-BX10-U ("upstream") device.

Ports

1 LC 1000BASE-BX10 port (IEEE 802.3ah Type 1000BASE-BX10-D); Duplex: full only

Physical characteristics

Dimensions

2.19(d) x 0.54(w) x 0.46(h) in. (5.57 x 1.37 x 1.18 cm)

Weight

0.04 lb. (0.02 kg)

Environment

Operating temperature

32ºF to 158ºF (0ºC to 70ºC)

Operating relative humidity

0% to 95%, non-condensing

Non-operating/
Storage temperature

–40ºF to 185ºF –40ºC to 85ºC)

Cabling

Type:
Single-mode fiber optic, complying with ITU-T G.652;

Maximum distance:

  • 0.5-10,000 m (single-mode fiber)

Notes

Transmit wavelength: 1490 nm. Receive wavelength: 1310 nm.
Power consumption is 1 watt maximum.
For supported platforms and minimum software requirements to support this product, see the document titled "Support for the HP BX Transceivers" on the "HP Mini-GBICs and SFPs" Manuals Web page.
The J9142B connects to the J9143B "upstream" transceiver, or to any IEEE-standard 1000BASE-BX10-U ("upstream") device. (A 1000-BX-D transceiver can only connect to a 1000-BX-U product. You cannot connect two 1000-BX-D transceivers together.)

Services

Refer to the HP website at: http://www.hp.com/networking/services for details on the service-level descriptions and product numbers. For details about services and response times in your area, please contact your local HP sales office.


 

HP X122 1G SFP LC BX-U Transceiver (J9143B)

A small form-factor pluggable (SFP) Gigabit-BX (bi-directional) "upstream" transceiver that provides a full-duplex Gigabit solution up to 10 km on one strand of single-mode fiber. The J9143B connects to the J9142B "downstream" transceiver, or to any IEEE-standard 1000BASE-BX10-D ("downstream")
device.

Ports

1 LC 1000BASE-BX10 port (IEEE 802.3ah Type 1000BASE-BX10-U); Duplex: full only

Physical characteristics

Dimensions

2.19(d) x 0.54(w) x 0.46(h) in. (5.57 x 1.37 x 1.18 cm)

Weight

0.04 lb. (0.02 kg)

Environment

Operating temperature

32ºF to 158ºF (0ºC to 70ºC)

Operating relative humidity

0% to 95%, non-condensing

Non-operating/
Storage temperature

–40ºF to 185ºF –40ºC to 85ºC)

Cabling

Type:
Single-mode fiber optic, complying with ITU-T G.652;

Maximum distance:

  • 0.5-10,000 m (single-mode fiber)

Notes

Transmit wavelength: 1310 nm. Receive wavelength: 1490 nm.
For supported platforms and minimum software requirements to support this product, see the document titled "Support for the HP BX Transceivers" on the "HP Mini-GBICs and SFPs" Manuals Web page.
The J9143B connects to the J9142B "downstream" transceiver, or to any IEEE-standard 1000BASE-BX10-D ("downstream") device. (A 1000-BX-U transceiver can only connect to a 1000-BX-D product. You cannot connect two 1000-BX-U transceivers together.)
Power consumption is 1 watt maximum.

Services

Refer to the HP website at: www.hp.com/networking/services for details on the service-level descriptions and product numbers. For details about services and response times in your area, please contact your local HP sales office.


 

HP 0.5 m Multimode OM3 LC/LC Optical Cable (AJ833A)

Cabling

Cable type:
50/125 µm (core/cladding) diameter, mulitimode fiber optic, with effective modal bandwidth of 2000 MHz/km as detailed in TIA-492AAAC for distances of up to 300 m

Maximum distance:
10Gbps Transfer Rate (Ethernet): 300m

Notes

Cable Specs: Tight buffered duplex fiber optic multimode OM3 50/125 um fiber optic cable and Ethernet assembly with LC duplex connectors on one end and LC duplex connectors on other end.

  • Dimensions: Core diameter: 50 ± 3.0um Cladding diameter: 125 ± 2.0um Coating diameter: 245 ± 10um
  • Optical glass: Bandwidth: For LED sources: 1500/500 MHz-km @850/1300nm.
  • Optical glass: Bandwidth: For Laser sources: 2000/500 MHz-km @850/1300nm. VCSEL Laser sources: 600 / 600 meters @850/1300nm for Gigabit Ethernet compliant links.
  • CABLE: The cable is duplex zipcord graded index 50/125um multimode optical fiber and designed to work in both the 850 and 1300 nm wavelength windows.
  • BULK CABLE & CABLE ASSEMBLY CONFIGURATION:
  • Jacket Material: Riser Grade - Low Smoke Zero Halogen thermoplastic.
  • Jacket Color: Aqua for OM3 multimode per TIA 598
  • Boot Color: White
  • Insertion Loss: less than 0.5 dB @ 850 with LED source, 0.003 dB/M added for lengths > 30 meters.
  • Maximum Cable attenuation: 3.0 dB/km @ 850 nm, 1.0 dB/Km @ 1310 nm @ 23°C as tested in accordance with EIA 455-46.
  • Weight: Air Packed Weight: 1 LB Net Weight: 0.454Kg

Services

Refer to the HP website at http://www.hp.com/networking/services for details on the service-level descriptions and product numbers. For details about services and response times in your area, please contact your local HP sales office.


 

HP Premier Flex LC/LC Multi-mode OM4 2 fiber 1m Cable (QK732A)

Notes

Cable Specs: Graded-index, "bendable" fiber optic multimode OM3+ 50/125um duplex cable and Ethernet assembly with LC duplex connectors on each end.

• Core Diameter: 50um ±3um, Cladding diameter: 125um ±2um; Coating diameter: 245 ± 10um
• Bandwidth: 3000 MHz-km @ 850nm (Laser)
• Jacket Color: Blue
• Jacket Material: Riser Grade – Low Smoke Zero Halogen (LSZH) thermoplastic
• Boot Color: White
• Outer Jacket Print: HP PremierFlex OM3+ Fiber Optic Cable, 50/125um, Type OFNR (UL), LSZH, cUL, OFN FT4, ROHS. Cable also has a longitudinal white stripe that runs the entire length of the cable.
• Insertion Loss: Less than 0.5dB @ 850nm with LED source, 0.003dB/m added for lengths >30m
• Maximum Cable Attenuation: 3.0 dB/km @ 850nm, 1.0 dB/km @ 1310nm @ 23°C as tested in accordance with EIA 455-45

Services

Refer to the HP website at www.hp.com/networking/services for details on the service-level descriptions and product numbers. For details about services and response times in your area, please contact your local HP sales office.


 

HP Premier Flex LC/LC Multi-mode OM4 2 fiber 2m Cable (QK733A)

Notes

Cable Specs: Graded-index, "bendable" fiber optic multimode OM3+ 50/125um duplex cable and Ethernet assembly with LC duplex connectors on each end.

• Core diameter: 50um ±3um, Cladding diameter: 125um ±2um; Coating diameter: 245 ± 10um
• Bandwidth: 3000 MHz-km @ 850nm (Laser)
• Jacket Color: Blue
• Jacket Material: Riser Grade – Low Smoke Zero Halogen (LSZH) thermoplastic
• Boot Color: White
• Outer Jacket Print: HP PremierFlex OM3+ Fiber Optic Cable, 50/125um, Type OFNR (UL), LSZH, cUL, OFN FT4, ROHS. Cable also has a longitudinal white stripe that runs the entire length of the cable.
• Insertion Loss: Less than 0.5dB @ 850nm with LED source, 0.003dB/m added for lengths >30m
• Maximum Cable Attenuation: 3.0 dB/km @ 850nm, 1.0 dB/km @ 1310nm @ 23°C as tested in accordance with EIA 455-45

Services

Refer to the HP website at http://www.hp.com/networking/services for details on the service-level descriptions and product numbers. For details about services and response times in your area, please contact your local HP sales office.


 

HP Premier Flex LC/LC Multi-mode OM4 2 fiber 5m Cable (QK734A)

Notes

Cable Specs: Graded-index, "bendable" fiber optic multimode OM3+ 50/125um duplex cable and Ethernet assembly with LC duplex connectors on each end.

• Core diameter: 50um ±3um, Cladding diameter: 125um ±2um; Coating diameter: 245 ± 10um
• Bandwidth: 3000 MHz-km @ 850nm (Laser)
• Jacket Color: Blue
• Jacket Material: Riser Grade – Low Smoke Zero Halogen (LSZH) thermoplastic
• Boot Color: White
• Outer Jacket Print: HP PremierFlex OM3+ Fiber Optic Cable, 50/125um, Type OFNR (UL), LSZH, cUL, OFN FT4, ROHS. Cable also has a longitudinal white stripe that runs the entire length of the cable.
• Insertion Loss: Less than 0.5dB @ 850nm with LED source, 0.003dB/m added for lengths >30m
• Maximum Cable Attenuation: 3.0 dB/km @ 850nm, 1.0 dB/km @ 1310nm @ 23°C as tested in accordance with EIA 455-45

Services

Refer to the HP website at www.hp.com/networking/services for details on the service-level descriptions and product numbers. For details about services and response times in your area, please contact your local HP sales office.


 

HP Premier Flex LC/LC Multi-mode OM4 2 fiber 15m Cable (QK735A)

Notes

Cable Specs: Graded-index, "bendable" fiber optic multimode OM3+ 50/125um duplex cable and Ethernet assembly with LC duplex connectors on each end.

• Core diameter: 50um ±3um, Cladding diameter: 125um ±2um; Coating diameter: 245 ± 10um
• Bandwidth: 3000 MHz-km @ 850nm (Laser)
• Jacket Color: Blue
• Jacket Material: Riser Grade – Low Smoke Zero Halogen (LSZH) thermoplastic
• Boot Color: White
• Outer Jacket Print: HP PremierFlex OM3+ Fiber Optic Cable, 50/125um, Type OFNR (UL), LSZH, cUL, OFN FT4, ROHS. Cable also has a longitudinal white stripe that runs the entire length of the cable.
• Insertion Loss: Less than 0.5dB @ 850nm with LED source, 0.003dB/m added for lengths >30m
• Maximum Cable Attenuation: 3.0 dB/km @ 850nm, 1.0 dB/km @ 1310nm @ 23°C as tested in accordance with EIA 455-45

Services

Refer to the HP website at http://www.hp.com/networking/services for details on the service-level descriptions and product numbers. For details about services and response times in your area, please contact your local HP sales office.


 

HP Premier Flex LC/LC Multi-mode OM4 2 fiber 30m Cable (QK736A)

Notes

Cable Specs: Graded-index, "bendable" fiber optic multimode OM3+ 50/125um duplex cable and Ethernet assembly with LC duplex connectors on each end.

• Core diameter: 50um ±3um, Cladding diameter: 125um ±2um; Coating diameter: 245 ± 10um
• Bandwidth: 3000 MHz-km @ 850nm (Laser)
• Jacket Color: Blue
• Jacket Material: Riser Grade – Low Smoke Zero Halogen (LSZH) thermoplastic
• Boot Color: White
• Outer Jacket Print: HP PremierFlex OM3+ Fiber Optic Cable, 50/125um, Type OFNR (UL), LSZH, cUL, OFN FT4, ROHS. Cable also has a longitudinal white stripe that runs the entire length of the cable.
• Insertion Loss: Less than 0.5dB @ 850nm with LED source, 0.003dB/m added for lengths >30m
• Maximum Cable Attenuation: 3.0 dB/km @ 850nm, 1.0 dB/km @ 1310nm @ 23°C as tested in accordance with EIA 455-45

Services

Refer to the HP website at www.hp.com/networking/services for details on the service-level descriptions and product numbers. For details about services and response times in your area, please contact your local HP sales office.


 

HP Premier Flex LC/LC Multi-mode OM4 2 fiber 50m Cable (QK737A)

Notes

Cable Specs: Graded-index, "bendable" fiber optic multimode OM3+ 50/125um duplex cable and Ethernet assembly with LC duplex connectors on each end.

• Core diameter: 50um ±3um, Cladding diameter: 125um ±2um; Coating diameter: 245 ± 10um
• Bandwidth: 3000 MHz-km @ 850nm (Laser)
• Jacket Color: Blue
• Jacket Material: Riser Grade – Low Smoke Zero Halogen (LSZH) thermoplastic
• Boot Color: White
• Outer Jacket Print: HP PremierFlex OM3+ Fiber Optic Cable, 50/125um, Type OFNR (UL), LSZH, cUL, OFN FT4, ROHS. Cable also has a longitudinal white stripe that runs the entire length of the cable.
• Insertion Loss: Less than 0.5dB @ 850nm with LED source, 0.003dB/m added for lengths >30m
• Maximum Cable Attenuation: 3.0 dB/km @ 850nm, 1.0 dB/km @ 1310nm @ 23°C as tested in accordance with EIA 455-45

Services

Refer to the HP website at http://www.hp.com/networking/services for details on the service-level descriptions and product numbers. For details about services and response times in your area, please contact your local HP sales office.


 

 

 

Summary of Changes

 

 

 

 

 

 

 

 

 

 

 

 

Date

Version History

Action

Description of Change:

24-Jul-2015

From Version 20 to 21

Changed

This QuickSpecs was retired; no further updates will be made.

09-Oct-2014

From Version 19 to 20

Changed

Accessory Product Details were revised

15-Apr-2014

From Version 18 to 19

Changed

Notes sections were revised throughout Configuration.

17-Jan-2014

From Version 17 to 18

Changed

Factory Racked Models and Switch Options were revised.

09-Dec-2013

From Version 16 to 17

Changed

Updated Features and Benefits, Introduction, the specifications, and Accessories, as well as the title of the document.

11-Nov-2013

From Version 15 to 16

Added

Configuration was added.

10-Jun-2013

From Version 14 to 15

Added

OM4 cables were added.

24-Sep-2012

From Version 13 to 14

Changed

Updated Features and Benefits, Introduction, the specifications, and Accessories.

25-Jun-2012

From Version 12 to 13

Changed

Updated Features and Benefits, Introduction, the specifications, and Accessories.

29-Nov-2011

From Version 11 to 12

Changed

The Features and Benefits section was updated.

20-Jun-2011

From Version 10 to 11

Changed

Updated the Accessories section.

14-Dec-2010

From Version 9 to 10

Changed

Corrected the Accessories section.

09-Sep-2010

From Version 8 to 9

Changed

The document was updated throughout to reflect the new name of this products as well as other HP Networking products.

02-Jun-2010

From Version 7 to 8

Changed

Updated the Notes section of Technical Specifications.

Updated Standards and Protocols

Added new cables to the Accessories section.

04-Mar-2010

From Version 6 to 7

Changed

The QuickSpec was completely revised.

16-Mar-2009

From Version 5 to 6

Changed

The Features, Accessories, Services, and Specifications (Performance, Environment, Electrical characteristics, Management, Standards and protocols) have changed for this product

01-Dec-2008

From Version 3 to 5

Added

"HP" to ProCurve Switch 6200yl-24G-mGBIC throughout the QuickSpec, including in the title

IPv6 to Connectivity in the Features and Benefits section and Standards and Protocols in the Technical Specifications section

USB Secure Autorun and STP Root Guard to Security

Classified-based rate limits to Quality of Services (QoS)

HP ProCurve 100-BX-D SFP-LC and HP ProCurve 100-BX-U SFP-LC Transceivers, HP ProCurve 1000-Bx-D SFP-LC Mini-GBIC, HP ProCurve 1000-BX-U SFP-LC Mini-GBIC and HP ProCurve 10-GbE X2-SC LRM Optic to Accessories

 

 

Changed

Remote intelligent mirror in Management in the Features and Benefits section

ProCurve trunking increased to 60 trunks in IEEE 802.3ad Link Aggregation Control Protocol (LACP) in the Features and Benefits section

Static IP Routing and OSPF in Layer 3 Routing in the Features and Benefits section

Multiple user authentication methods in the Features and Benefits section

16-Nov-2006

From Version 2 to 3

Changed

Corrected the Current and Power consumption specifications.

18-Aug-2006

From Version 1 to 2

Changed

Changes made throughout the QuickSpec.

 

To learn more, visit www.hp.com/networking

© Copyright 2015 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein.