NOTE: For more information regarding Intel Xeon processors, please see the following http://www.intel.com/xeon. |
|
|
|
|
|
Processor
Up to two of the following depending on model |
|
Model |
CPU frequency |
Cores
|
L3 Cache |
Power |
QPI |
DDR4 Hz |
|
E5-2690v3 |
2.6GHz |
12 |
30MB |
135W |
9.6GT/s |
2133 |
|
E5-2680v3 |
2.5GHz |
12 |
30MB |
120W |
9.6GT/s |
2133 |
|
E5-2670v3 |
2.3GHz |
12 |
30MB |
120W |
9.6GT/s |
2133 |
|
E5-2667v3 |
3.2GHz |
8 |
20MB |
135W |
9.6GT/s |
2133 |
|
E5-2660v3 |
2.6GHz |
10 |
25MB |
105W |
9.6GT/s |
2133 |
|
E5-2650v3 |
2.3GHz |
10 |
25MB |
105W |
9.6GT/s |
2133 |
|
E5-2650Lv3 |
1.8GHz |
12 |
30MB |
65W |
9.6GT/s |
2133 |
|
E5-2643v3 |
3.4GHz |
6 |
20MB |
135W |
9.6GT/s |
2133 |
|
E5-2640v3 |
2.6GHz |
8 |
20MB |
90W |
8.0GT/s |
1866 |
|
E5-2630v3 |
2.4Ghz |
8 |
20MB |
85W |
8.0GT/s |
1866 |
|
E5-2630Lv3 |
1.8GHz |
8 |
20MB |
55W |
8.0GT/s |
1866 |
|
E5-2620v3 |
2.4GHz |
6 |
15MB |
85W |
8.0GT/s |
1866 |
|
E5-2609v3 |
1.9GHz |
6 |
15MB |
85W |
6.4GT/s |
1600 |
|
E5-2603v3 |
1.6GHz |
6 |
15MB |
85W |
6.4GT/s |
1600 |
|
E5-2698v4 |
2.2GHz |
20 |
50MB |
135W |
9.6GT/s |
2400 |
|
E5-2697v4 |
2.3GHz |
18 |
45MB |
145W |
9.6GT/s |
2400 |
|
E5-2695v4 |
2.1GHz |
18 |
45MB |
120W |
9.6GT/s |
2400 |
|
E5-2683v4 |
2.1GHz |
16 |
40MB |
120W |
9.6GT/s |
2400 |
|
E5-2620v4 |
2.1GHz |
8 |
20MB |
85W |
8.0GT/s |
2133 |
NOTE: All processors above 120W use a high efficiency Heatsink. Doublewide PCIe cards are only supported with this Heatsink. For processors with a standard Heatsink that require double wide PCIe cards, the Graphics Enablement kit option is also required (719082-B21). |
|
|
|
|
|
Chipset |
|
Intel® C610 Series Chipset |
|
Intel® E5-2600v3 Processor Family |
|
NOTE: For more information regarding Intel chipsets, please see the following URL: http://www.intel.com/products/server/chipsets/. | |
|
| |
|
|
On System Management Chipset |
|
HPE iLO (Firmware HPE iLO4 2.0) 4GB NAND
NOTE: 1GB USB user space configurable via UEFI and accessible via iLO. Read and learn more in the iLO QuickSpecs. | | |
|
| |
|
|
Memory
One of the following depending on model
|
Type:
|
HPE SmartMemory |
|
|
|
DDR4 Registered (RDIMM) or Load Reduced (LRDIMM) |
|
|
|
DIMM Slots Available |
24 |
(12 DIMM slots per processor, 4 channels per processor, 3 DIMMs per channel) |
|
|
Maximum Capacity (LRDIMM) |
1.5TB |
(24 x 64GB LRDIMM @2133MHz) | |
|
Maximum Capacity (RDIMM) |
768GB |
(24 x 32GB RDIMM @2133MHz) | | |
|
|
|
| |
|
| |
|
|
Memory Protection |
|
Advanced ECC |
Advanced ECC uses single device data correction to detect and correct single and all multibit error that occurs within a single DRAM chip. | |
|
Online spare |
Memory online spare mode detects a rank that is degrading and switches operation to the spare rank. | | |
|
| |
|
|
Expansion Slots |
|
|
Primary Riser (Standard) |
|
Expansion Slots # |
Technology |
Bus Width |
Connector Width |
Bus Number |
Form Factor |
Notes |
|
1 |
PCIe 3.0 |
x8 |
x16 |
7 |
Full-height, half-length slot |
Proc 1 |
|
2 |
PCIe 3.0 |
x8 |
x16 |
10 |
Full-height, half-length slot |
Proc 1 |
|
3 |
PCIe 3.0 |
x8 |
x8 |
13 |
Half Length/Full Height |
Proc 1 |
|
* Default bus assignment (in decimal). Inserting cards with PCI bridges may alter the actual bus assignment number. ** Indicates the number of physical electrical lanes running to the connector.
NOTE: All slots support PCIe cards to 150W or more depending on card, but an additional Power Cord Option is required (PN 669777-B21). See Option Section below for offering. | | |
|
|
Slot 2 PCIe Riser (Optional 3-slot)
719073-B21 |
|
Expansion Slots # |
Technology |
Bus Width |
Connector Width |
Bus Number |
Device Number |
Form Factor |
Notes |
|
4 |
PCIe 3.0 |
x16 |
x16 |
16 |
|
Full-height, full-length slot |
Proc 2 |
|
5 |
PCIe 3.0 |
x16 |
x16 |
20 |
|
Full-height, full-length slot |
Proc 2 |
|
6 |
PCIe 3.0 |
x8 |
x8 |
23 |
|
Full-height, half-length slot |
Proc 2 |
|
* Default bus assignment (in decimal). Inserting cards with PCI bridges may alter the actual bus assignment number. ** Indicates the number of physical electrical lanes running to the connector. NOTE: When populating the second optional riser slot, the second processor must be installed. NOTE: All slots support PCIe cards to 150W or more depending on card but an additional Power Cord Option is required (PN 669777-B21). See Option Section below for offering. | | |
|
|
|
|
|
Storage Controller
One of the following depending on model |
|
Entry Models |
|
HPE Dynamic Smart Array B140i Controller | |
|
NOTE: The embedded B140i controller will operate in UEFI only mode. For legacy support an additional controller will be needed, and for CTO orders please also select the Legacy mode settings part, 758959-B22.
NOTE: The B140i defaults to AHCI off the chipset. Smart array needs to be enables on the SATA only models if required.
NOTE: The B140i will not operate in Legacy mode. | |
|
Base Models |
|
HPE Dynamic Smart Array B140i Controller |
|
HPE Flexible Smart Array P440ar/2G FIO Controller |
|
HPE Flexible Smart Array P840/4G FIO Controller | | |
|
Performance Models |
|
HPE Dynamic Smart Array B140i Controller |
|
HPE Flexible Smart Array P440ar/2GB | | | |
|
| |
|
|
Internal Storage Devices
One of the following depending on model |
|
Optical Drive
|
|
Ships standard in Performance Models |
|
Optional: DVD-ROM, DVD-RW | |
|
Hard Drives |
|
|
Hard Drive Bays |
|
8 SFF with optional Universal Media bay or 8SFF bay options | | | |
|
|
|
|
|
Power Supply |
|
HPE 800W Flex Slot Platinum Hot Plug Power Supply
HPE 800W Flex Slot -48VDC Hot Plug Power Supply |
All
pre-configured servers ship with a standard 6-foot IEC C-13/C-14
jumper cord (A0K02A). This jumper cord is also included with each
standard AC power supply option kit. If a different power cord
is required, please check the ProLiant
Power Cables
web
page.
To
review the power requirements for your selected system, please
use the HPE Power Advisor Tool located at http://www.hpe.com/info/hppoweradvisor.
Power specifications and technical content for all HPE Server power supplies can be found at http://www.hp.com/go/proliant/powersupply. |
|
| |
|
|
System Fans
One of the following depending on model |
|
|
Non-redundant |
Redundant |
|
2P model |
|
6 fans |
NOTE: High Performance Fan Kit is required for NEBS Compliance. | |
|
| |
|
|
Interfaces |
|
|
|
Video |
2 (1 front, optional via Universal Media Bay, 724865-B21), 1 back not active simultaneously | |
|
FlexibleLOM Network Ports |
4 x 1Gb ports shipping standard with optional FlexibleLOM | |
|
HPE iLO Remote Management Network Port |
1 Gb Dedicated | |
|
NOTE: The Micro SD slot is not a hot-pluggable device. Customers should not attempt to plug an SD card into the SD slot while the server is powered. |
|
USB 3.0 |
Up to 5 total: 1 front, 2 rear, 2 internal (secure), 2 optional USB 2.0 front via Universal Media Bay | |
|
SID (Systems Insight Display) |
Optional |
NOTE: Not shipping as standard. Available as a CTO option or as a field upgrade (768900-B21). | |
|
| |
|
|
Operating Systems and Virtualization Software Support for ProLiant Servers |
|
Microsoft Windows Server |
|
Canonical Ubuntu |
|
Red Hat Enterprise Linux (RHEL) |
|
SUSE Linux Enterprise Server (SLES) |
|
Oracle Solaris |
|
VMware |
|
Citrix XenServer |
|
NOTE: For more information on HPE's Certified and Supported ProLiant Servers for OS and Virtualization Software and latest listing of software drivers available for your server, please visit our Support Matrix at: http://www.hp.com/go/ossupport and our driver download page: http://www.hp.com/support/DL380Gen9. | |
|
| |
|
|
Upgradeability |
|
Upgradeable to two processors (36 Cores)
NOTE: Processor upgrade available from Intel® Xeon® Processors E5-2600v3. Please contact HPE Technology Sales (http://www.hp.com/support), your local Hewlett Packard Enterprise Re-seller. |
|
Up to 24 DIMM slots available for higher Memory capacity |
|
FlexibleLOM connector for 1 Gigabit or 10 Gigabit networking options |
|
HPE Flexible Smart Array or Smart HBA Controllers
Embedded 10-Port SATA, B140i as standard |
|
Optional 3 slot riser (x16, x16, x8), or 2 slot primary riser (x16, x8)
NOTE: To take advantage of the additional 3 PCI slot upgrade, the second processor must be installed. |
|
Redundant Power Supply |
|
Optical Drive supported via Universal Media Bay
NOTE: The Universal Media bay provides front VGA and 2xUSB 2.0, plus ability to add 2SFF and Optical.
NOTE: Universal Media bay is only available with 8 or 8+8SFF chassis & can be populated in Bay1 only. |
|
HPE Legacy Mode (FIO only, 758959-B22)
NOTE: UEFI is the default mode for CTO and BTO SKUs. Can change default to legacy via CTO. | |
|
| |
|
|
Industry Standard Compliance |
|
ACPI 2.0b Compliant |
|
PCIe 3.0 Compliant |
|
PXE Support |
|
WOL Support |
|
Microsoft® Logo certifications |
|
USB 3.0 Support |
|
USB 2.0 Support
NOTE: This support is on the optional Universal Media Bay. |
|
Energy Star |
|
ASHRAE A3/A4
NOTE: The DL380 Gen9 is now one of the first HPE ProLiant Gen9 Servers with Extended Ambient Support up to 45 C for data center infrastructures designed for better energy efficiency such as but not limited to fresh air cooling.
For additional technical thermal details regarding ambient temperatures, humidity and features support please visit: http://www.hpe.com/servers/ashrae. |
|
UEFI (Unified Extensible Firmware Interface Forum)
NOTE: UEFI is the default for the DL380 Gen9. Legacy model can be selected in the field or as a CTO option (758959-B22). | |
|
| |
|
|
Graphics |
|
Integrated
Matrox G200eH2 video standard with 16MB of Video RAM
-
1280
x 1024 (32 bpp)
-
1920
x 1200 (16 bpp)
|
|
|
|
HPE
iLO 4 On System Management Memory
-
16
MB Flash
-
256
MB DDR3 with ECC (112 MB after ECC and video)
|
|
|
| |
|
|
HPE Server UEFI/Legacy ROM |
HPE
Server UEFI /Legacy ROM
Unified
Extensible Firmware Interface (UEFI) is an industry standard that
provides better manageability and more secured configuration while
interacting with your server at boot time. HPE ProLiant Gen9 platform
defaults to UEFI and can be factory or field configured for Legacy
BIOS Boot Mode.
NOTE:
The
UEFI System Utilities function is analogous to the HPE ROM-Based
Setup Utility (RBSU) of legacy BIOS. For more information, please
visit http://www.hp.com/go/proliantuefi/docs.
UEFI
enables numerous new capabilities specific to HPE ProLiant servers
such as:
-
Secure
Boot
-
Operating
system specific functionality
-
Support
for > 2.2 TB (using GPT) boot drives
-
USB
3.0 Stack
-
Embedded
UEFI Shell
-
Mass
Configuration Deployment Tool using
HPE RESTful API.
-
PXE
boot support for IPv6 networks
-
Boot
support for option cards that only support a UEFI option ROM
For
more information please visit http://www.hp.com/go/proliant/uefi.
NOTE: For
UEFI Boot Mode, boot environment and OS image installations should
be configured properly to support UEFI.
NOTE:
HPE Legacy
FIO Mode Setting
(758959-B22) can be selected to configure the system in Legacy
mode in the factory.
|
|
| |
|
|
Form Factor
One of the following depending on model |
2U Rack form factor
8 SFF Version: 3.44 x 17.54 x 26.75 in (8.73 x 44.55 x 67.94 cm) |
|
NOTE: Dimensions without bezel. |
|
| |
|
|
Embedded Management |
|
HPE Integrated Lights-Out (HPE iLO) |
Monitor your servers for ongoing management, service alerting, reporting and remote management with iLO. Learn more at http://www.hp.com/go/ilo.
|
|
UEFI |
Configure and boot your servers securely with industry standard Unified Extensible Firmware Interface (UEFI). Learn more at http://www.hp.com/go/ProLiant/uefi.
|
|
HPE RESTful API |
RESTful API is an application programming interface. RESTful Web Service API served by iLO's web server. Learn more at http://www.hp.com/go/restfulapi.
|
|
Intelligent Provisioning |
Provision servers by discovering and deploying 1 to few servers with Intelligent Provisioning. Learn more at http://www.hp.com/go/intelligentprovisioning.
|
|
Embedded Remote Support |
HPE's embedded remote support, used with Insight Online direct connect or HPE Insight Remote Support, allows HPE ProLiant servers to transmit hardware events directly to HPE or a Hewlett Packard Enterprise Authorized Partner for automated phone home support. Learn more at http://www.hp.com/go/insightonline/info. | | |
|
|
|
|
|
Server utilities |
|
HPE Smart Update |
Optimize firmware and driver updates with HPE Smart Update solutions. Learn more at http://www.hp.com/go/smartupdate.
|
|
HPE Systems Insight Manager (HPE SIM) |
HPE SIM allows you to monitor the health of your HPE ProLiant Servers and HPE Integrity Servers, and also provides you with basic support for non-Hewlett Packard Enterprise servers.
HPE SIM also integrates with HPE SUM to provide quick and seamless firmware updates. Learn more at http://www.hp.com/go/sim.
|
|
Scripting Tool Kit and Windows PowerShell |
Provision 1 to many servers using your own scripts to discover and deploy them with HPE Scripting Tool Kit for Windows and Linux or HPE Scripting Tools for Windows PowerShell. Learn more at http://www.hp.com/go/ProLiantSTK or http://www.hp.com/go/powershell.
|
|
HPE RESTful Interface Tool |
HPE RESTful Interface tool is a scripting tool to provision servers using RESTful API Interface to discover and deploy servers at scale. Learn more at http://www.hp.com/go/restfulapi.
|
|
HPE iLO Mobile Application |
Enables the ability to access, deploy, and manage your server anytime from anywhere from select smartphones and mobile devices. For additional information please visit: http://www.hp.com/go/ilo/mobileapp.
|
|
HPE Insight Online |
HPE Insight Online, available at no additional cost as part of your HPE warranty, Care Pack or contractual support agreement with HPE, is a personalized dashboard for simplified tracking of IT operations and support information from anywhere, anytime. Learn more at http://www.hp.com/go/insightonline/info. | | |
|
|
|
|
|
Security |
|
Power-on password |
|
Serial interface control |
|
Administrator's password |
|
UEFI |
|
iLO 4 (Integrated Lights-Out 4) has 12 customizable user accounts and SSL encryption |
|
Integrated Lights-Out can be disabled via a Global Setting |
|
iLO Advanced supports directory services integration |
|
TPM 1.2 | |
|
| |
|
Warranty |
This product is covered by a global limited warranty and supported by HPE Services and a worldwide network of Hewlett Packard Enterprise Authorized Channel Partners resellers. Hardware diagnostic support and repair is available for three years from date of purchase. Support for software and initial setup is available for 90 days from date of purchase. Enhancements to warranty services are available through HPE Pointnext operational services or customized service agreements. Hard drives have either a one year or three year warranty; refer to the specific hard drive QuickSpecs for details.
NOTE: Server Warranty includes 3-Year Parts, 3-Year Labor, 3-Year Onsite support with next business day response. Warranty repairs may be accomplished through the use of Customer Self Repair (CSR) parts. These parts fall into two categories: 1) Mandatory CSR parts are designed for easy replacement. A travel and labor charge will result when customers decline to replace a Mandatory CSR part; 2) Optional CSR parts are also designed for easy replacement but may involve added complexity. Customers may choose to have HPE replace Optional CSR parts at no charge. Additional information regarding worldwide limited warranty and technical support is available at: http://h18004.www1.hp.com/products/servers/platforms/warranty/index.html. | |
|
|
|
|