Dell PowerEdge XR4520c: руководство по обслуживанию

Sled dimensions

Figure 1. Sled dimensions

This figure shows the dimensions of the XR4520c server sled.

Table 1. PowerEdgeXR4520c sled dimensionsThis table provides the dimensions of the sled:
X Y Z (handle closed).
167.2 mm (6.58 inches)83.25 mm (3.27 inches)342.5 mm (13.48 inches)

System weight

Table 1. PowerEdge XR4520c system weightThe table below shows the maximum weight of the system.
System configuration Maximum weight (with all SSDs)
1 x DIMM, 1 x M.2 NVMe SSDs on M.2 riser, 1 x M.2 NVMe SSD on BOSS-N1 3.15 kg (6.94 pound)
4 x DIMMs, 4 x M.2 NVMe SSDs on M.2 riser, 2 x M.2 NVMe SSDs on BOSS-N1, 1 x Double Width GPU 4.69 kg (10.34 pound)

Processor specifications

Table 1. PowerEdge XR4520c processor specifications This table provides processor specifications for the system.
Supported processor Number of processors supported
3rd Generation Intel Xeon D Scalable processor with up to 20 cores One

Cooling fan specifications

The PowerEdgeXR4520csystem supports up to three Standard (STD) cabled cooling fans for reverse and normal air-flow.

Table 1. Cooling fan specificationsCooling fan specifications
Fan type Label color Label image
3 x Standard (STD) fans (210 mm cable length) on the upper layer No labelThis image shows the Standard (STD) cabled cooling fans

Supported operating systems

The PowerEdge XR4520c system supports the following operating systems:

  • Canonical Ubuntu Server LTS
  • Microsoft Windows Server with Hyper-V
  • Red Hat Enterprise Linux
  • SUSE Linux Enterprise Server
  • VMware ESXi
  • Dell NativeEdge OS

For more information, go to OS support.

System battery specifications

The PowerEdge XR4520c system supports CR 2032 3.0-V lithium coin cell system battery.

Memory specifications

The PowerEdge XR4520c system supports the following memory specifications for optimized operation.
Table 1. Memory specificationsThe table below shows the memory specifications:
DIMM type DIMM rank DIMM capacity Single processor
Minimum system capacity Maximum system capacity
RDIMM Dual rank 16 GB 16 GB 64 GB
32 GB 32 GB 128 GB
64 GB 64 GB 256 GB
LRDIMM Quad rank 128 GB 128 GB 512 GB
Table 2. Memory module socketsThe table below shows the memory module sockets for the system:
Memory module sockets Speed
4, 288-pin 3200 MT/s
NOTE:Memory DIMM slots are not hot swappable.
NOTE:The DIMM memory speed is 3200 MT/s. However, the system memory operating speed is up to 2933 MT/s due to CPU restrictions.

Expansion card riser specifications

WARNING:Consumer-Grade GPU should not be installed or used in the Enterprise Server products.
The PowerEdge XR4520c system supports one PCI express (PCIe) expansion card riser on the upper layer of the sled.
Table 1. Expansion card slots supported on the 2U sledThis table provides information about the expansion card slots that are supported on the 2U sled.
PCIe slots Expansion card riser Processor connection Height Length Slot width
Slot 1 and 2 Riser 1C Processor 1 Full Height Three-quarter Length x16 PCIe (Gen 4)

Storage controller specifications

The PowerEdge XR4520c system supports Boot Optimized Storage Subsystem (BOSS-N1): 2 x M.2 SSDs as internal boot.

Drives

The PowerEdge XR4520c system supports 4 x M.2 SSDs (M.2 2280 and M.2 22110) on the M.2 riser and 8 x M.2 NVMe SSDs on the PCIe Add-in card (AIC) installed on the riser module assembly.

GPU specifications

The PowerEdge XR4520c system supports up to two 150W single-width GPUs or one 250W double-width GPU.

NOTE:Systems configured with GPUs will have higher fan acoustics.

USB ports specifications

Table 1. PowerEdge XR4520c USB specificationsThe following table shows the USB specifications for the system:
Front Internal (Optional)
USB port type No. of ports USB port type No. of ports
USB 3.0-compliant port Two USB 3.0-compliant port One
Micro-AB USB 2.0-compliant port for iDRAC Direct One

NIC port specifications

The PowerEdge XR4520c system supports up to four Network Interface Controller (NIC) ports on the Network I/O board.
Table 1. NIC port specification for the systemThis table describes the NIC port specification for the system.
Feature Specifications
Network I/O board 10 GbE SFP x 4 (max 50 Gb), 25 GbE SFP x 4 (max 100 Gb)
NOTE:The Network I/O board throughput depends on the core count of the processor that is used.
  • 10GbE x 4 (max 50Gb) specification is supported on processor with up to 8 cores.
  • 25GbE x 4 (max 100Gb) specification is supported on processor with 12-20 cores or more.

Serial connector specifications

The PowerEdge XR4520c system supports one Micro-USB debug port for Universal Asynchronous Receiver or Transmitter (UART) on the front of the system.

Display port specifications

The PowerEdge XR4520c system supports one Mini-DisplayPort on the front of the system.

iDRAC9 port specifications

The PowerEdge XR4520c system supports one RJ45 port with status LEDs for iDRAC remote management (dedicated port only) on the front of the system.

Video specifications

The PowerEdge XR4520c system supports integrated Matrox G200 graphics controller embedded in the iDRAC (BMC) chip with 16 MB of video frame buffer.
Table 1. Supported video resolution options This table describes the supported front video resolution options for the system.
Resolution Refresh rate (Hz) Color depth (bits)
640 x 480 60 8, 16, 32
800 x 600 60 8, 16, 32
1024 x 768 60 8, 16, 32
1152 x 864 60 8, 16, 32
1280 x 800 60 8, 16, 32
1280 x 1024 60 8, 16, 32
1360 x 768 60 8, 16, 32
1400 x 1050 60 8, 16, 32
1440 x 900 60 8, 16, 32
1600 x 1200 60 8, 16, 32
1680 x 1050 60 8, 16, 32
1920 x 1080 60 8, 16, 32
1920 x 1200 60 8, 16, 32

Environmental specifications

NOTE:For additional information about environmental certifications, refer to the Product Environmental Datasheet located with the Documentation on Dell Support.
Table 1. Operational climatic range ASHRAE category A4The following table shows the operational climatic range ASHRAE category A4
ASHRAE A4 Allowable continuous operations
Temperature Ranges (For Altitude <900 meters or 2953 feet) 5°C-45°C (41°F-113°F) with no direct sunlight on the equipment
Humidity Percent Ranges (Non-Condensing at all times) 8% RH with -12°C minimum dew point to 90% RH with 24°C (75.2°F) maximum dew point
Operational Altitude De-Rating Maximum temperature is reduced by 1°C/125 meters (1.8°F/410 feet) above 900 meters (2,953 feet)
Table 2. Operational climatic range ASHRAE Rugged (limits available components)The following table shows the operational climatic range ASHRAE Rugged (limits available components).
Rugged Allowable continuous operations
Temperature Ranges (For Altitude <900 meters or 2953 feet) -5°C-55°C (23°F-131°F) with no direct sunlight on the equipment
Humidity Percent Ranges (Non-Condensing at all times) 8% RH with -12°C minimum dew point to 90% RH with 24°C (75.2°F) maximum dew point
Operational Altitude De-Rating Maximum temperature is reduced by 1°C/80 meters (1.8°F/262 feet) above 900 meters (2,953 feet)
Table 3. Shared requirementsThe following table shows the shared requirements,
Allowable continuous operations
Maximum Temperature Gradient (applies to both operation and non-operation)

20°C in an hour* (36°F in an hour) and 5°C in 15 minutes (9°F in 15 minutes),

5°C in an hour* (9°F in an hour) for tape hardware

Non-Operational Temperature Limits -40°C-65°C (-40°F-149°F)
Non-Operational Humidity Limits (Non-Condensing at all times) 5% to 95% RH with 27°C (80.6°F) maximum dew point.
Maximum Non-Operational Altitude 12,000 meters (39,370 feet)
Maximum Operational Altitude 3,048 meters (10,000 feet)

Environmental Considerations

The PowerEdge XR4520c system is targeted for edge deployments and it meets all the additional standards for thermal, shock, vibration parameters.
Table 1. Environmental considerationsEnvironmental considerations
Industry Configuration Description
Telco GR-1089-CORE Electromagnetic Compatibility and Electrical Safety – Generic Criteria for Network Telecommunications Equipment
GR-63-CORE NEBS Requirements: Physical Protection
SR-3580 (NEBS Level 3) NEBS Criteria Levels
GR-3108-CORE (Class 1) Network Equipment in the Outside Plant (OSP). An exception is made for cold boot at 0C instead of -5C.
Military MILSTD 810H Environmental engineering considerations and laboratory test
MILSTD 461G/// Requirements for the control of electromagnetic interference characteristic of subsystems and equipment
MILSTD 901E High impact shock test – Shipboard
MILSTD 1474E Department of Defense Design Criteria Standard Noise Limits
Marine IEC-60945 Maritime navigation and radiocommunication equipment and systems – General requirements
DNV-GL Environmental Test Specification for Instrumentation and Automation Equipment
Power Industry IEEE 1613 Environmental and testing requirements for communications networking devices in electric power substations
IEC – 61850-3 Communication networks and systems for power utility automation
Safety NA LDV, IEC/EN, CFR, CSA
EMC NA EN, CISPR, ES, DTAG, CFR, ICES, VCCI
EMV NA RoHS, WEEE, EN, ECE

Particulate and gaseous contamination specifications

The following table defines the limitations that help avoid any equipment damage or failure from particulates and gaseous contamination. If the levels of particulates or gaseous pollution exceed the specified limitations and result in equipment damage or failure, you must rectify the environmental conditions. Remediation of environmental conditions is the responsibility of the customer.

Table 1. Particulate contamination specificationsAir filtration specification: Data center air filtration as defined by ISO Class 8 per ISO 14644-1 should have a 95% upper confidence limit. Note: This condition applies only to data center environments. Air filtration requirements do not apply to IT equipment designed to be used outside a data center, in environments such as an office or factory floor. Note: Air entering the data center must have MERV11 or MERV13 filtration. Conductive dust specification: Air must be free of conductive dust, zinc whiskers, or other conductive particles. Note: This condition applies to data center and non-data center environments. Corrosive dust specification: Air must be free of corrosive dust. Residual dust present in the air must have a deliquescent point less than 60% relative humidity. Note: This condition applies to data center and non-data center environments.
Particulate contamination Specifications
Air filtration: Conventional Data Center only Data center air filtration as defined by ISO Class 8 per ISO 14644-1 with a 95% upper confidence limit
NOTE: Filtering room air with a MERV8 filter, as specified in ANSI/ASHRAE Standard 127, is a recommended method for achieving the necessary environmental conditions.
NOTE:Air entering the data center must have MERV11 or MERV13 filtration.
NOTE:This condition applies to data center environments only. Air filtration requirements do not apply to IT equipment designed to be used outside a data center, in environments such as an office or factory floor.
Walk-Up Edge Data Center or Cabinet (sealed, closed loop environment) Filtration is not required for cabinets that are anticipated to be opened six times or less per year. Class 8 per ISO 1466-1 filtration as defined above is required otherwise.
NOTE: In environments commonly above ISA-71 Class G1 or that may have known challenges, special filters may be required.
Conductive dust: data center and non-data center environments Air must be free of conductive dust, zinc whiskers, or other conductive particles.
NOTE: Conductive dust, which can interfere with equipment operation, can originate from various sources, including manufacturing processes and zinc whiskers that may develop on the plating of raised floor tiles.
NOTE:This condition applies to data center and non-data center environments.
Corrosive dust: data center and non-data center environments
  • Air must be free of corrosive dust.
  • Residual dust present in the air must have a deliquescent point less than 60% relative humidity.
NOTE:This condition applies to data center and non-data center environments.
Table 2. Gaseous contamination specificationsThe copper coupon corrosion rate is <300 Å/month per Class G1 as defined by ANSI/ISA71.04. The silver coupon corrosion rate is <200 Å/month as defined by ANSI/ISA71.04.
Gaseous contamination Specifications Notes
Copper coupon corrosion rate ISA-71 Class G1: <300 Å/month Per ANSI/ISA71.04
Silver coupon corrosion rate ISA-71 Class G1: <200 Å/month Per ANSI/ISA71.04

Thermal restriction matrix

Table 1. XR4000r RAF Configuration Matrix The table describes RAF configuration matrix for XR4000r chassis type:
CPU Type HSK type Fan type RAF Configurations
Edge 2 (Max 55°C) Edge 1 (Max 50°C) ASHRAE A4 (Max 45°C)
Intel® Xeon® D - 2796NT, 20C,120W Vaper Chamber (VC) HSK Standard (STD) fan Yes Yes Yes
Intel® Xeon® D - 2776NT,16C,117W Yes Yes Yes
Intel® Xeon® D - 2753NT,12C,87W Yes Yes Yes
Intel® Xeon® D - 2733NT,8C,80W Yes Yes Yes
Intel® Xeon® D - 2712T,4C,65W Yes Yes Yes
Table 2. XR4000z RAF Configuration Matrix The table describes RAF configuration matrix for XR4000z chassis type:
CPU Type HSK type Fan type RAF Configurations
Edge 2 (Max 55°C) Edge 1 (Max 50°C) ASHRAE A4 (Max 45°C)
Intel® Xeon® D - 2796NT, 20C,120W Vaper Chamber (VC) HSK Standard (STD) fan Yes Yes Yes
Intel® Xeon® D - 2776NT,16C,117W Yes Yes Yes
Intel® Xeon® D - 2753NT,12C,87W Yes Yes Yes
Intel® Xeon® D - 2733NT,8C,80W Yes Yes Yes
Intel® Xeon® D - 2712T,4C,65W Yes Yes Yes

PCI-E Card Support

Table 3. XR4000r PCI-E Card Support Thermal Limitation (RAF Configurations) The table describes PCI-E Card Support Thermal Limitation (RAF Configurations) for XR4000r chassis:
PCI-E Type RAF Configurations
Edge 2 (Max 55°C) Edge 1 (Max 50°C) ASHRAE A4 (Max 45°C)
nvidia GPGPU A2 Not Supported Yes
nvidia GPGPU A30 Yes
Table 4. XR4000z PCI-E Card Support Thermal Limitation (RAF Configurations) The table describes PCI-E Card Support Thermal Limitation (RAF Configurations) for XR4000z chassis:
PCI-E Type RAF Configurations
Edge 2 (Max 55°C) Edge 1 (Max 50°C) ASHRAE A4 (Max 45°C)
nvidia GPGPU A2 Not Supported Yes
nvidia GPGPU A30 Yes
Table 5. M.2 Support Thermal Limitation for XR4000r Chassis (RAF Configurations) M.2 Support Thermal Limitation for XR4000r Chassis (RAF Configurations)
M.2 Type Riser Module BOSS Module AIC Card
Edge 2 (Max 55°C) Edge 1 (Max 50°C) ASHRAE A4 (Max 45°C) Edge 2 (Max 55°C) Edge 1 (Max 50°C) ASHRAE A4 (Max 45°C) Edge 2 (Max 55°C) Edge 1 (Max 50°C) ASHRAE A4 (Max 45°C)
Micron 480GB Yes Yes Yes Yes Yes Yes Yes Yes Yes
Micron 800GB Yes Yes Yes Yes Yes Yes Yes Yes Yes
Micron 960GB Yes Yes Yes Yes Yes Yes Yes Yes Yes
Micron 1.92TB Throttling Active Yes Yes No No No Yes Yes Yes
Micron 3.84TB Throttling Active Yes Yes No No No Yes Yes Yes
Hynix 480GB Yes Yes Yes Yes Yes Yes Yes Yes Yes
Hynix 800GB Yes Yes Yes Yes Yes Yes Yes Yes Yes
Hynix 960GB Yes Yes Yes Yes Yes Yes Yes Yes Yes
Hynix 1.92TB Yes Yes Yes No No No Yes Yes Yes
Hynix 3.84BT Yes Yes Yes No No No Yes Yes Yes
Table 6. M.2 Support Thermal Limitation for XR4000z Chassis (RAF Configurations)M.2 Support Thermal Limitation for XR4000z Chassis (RAF Configurations)
M.2 Type Riser Module BOSS Module AIC Card
Edge 2 (Max 55°C) Edge 1 (Max 50°C) ASHRAE A4 (Max 45°C) Edge 2 (Max 55°C) Edge 1 (Max 50°C) ASHRAE A4 (Max 45°C) Edge 2 (Max 55°C) Edge 1 (Max 50°C) ASHRAE A4 (Max 45°C)
Micron 480GB Yes Yes Yes Yes Yes Yes Yes Yes Yes
Micron 800GB Yes Yes Yes Yes Yes Yes Yes Yes Yes
Micron 960GB Yes Yes Yes Yes Yes Yes Yes Yes Yes
Micron 1.92TB Throttling Active Yes Yes No No No Yes Yes Yes
Micron 3.84TB Throttling Active Yes Yes No No No Yes Yes Yes
Hynix 480GB Yes Yes Yes Yes Yes Yes Yes Yes Yes
Hynix 800GB Yes Yes Yes Yes Yes Yes Yes Yes Yes
Hynix 960GB Yes Yes Yes Yes Yes Yes Yes Yes Yes
Hynix 1.92TB Yes Yes Yes No No No Yes Yes Yes
Hynix 3.84BT Yes Yes Yes No No No Yes Yes Yes
Table 7. XR4000r NAF Configuration Matrix The table describes NAF configuration matrix for XR4000r chassis type:
CPU Type HSK type Fan type RAF Configurations
Edge 2 (Max 55°C) Edge 1 (Max 50°C) ASHRAE A4 (Max 45°C)
Intel® Xeon® D - 2796NT, 20C,120W Vaper Chamber (VC) HSK Fan No No Yes
Intel® Xeon® D - 2776NT,16C,117W No No Yes
Intel® Xeon® D - 2753NT,12C,87W No No Yes
Intel® Xeon® D - 2733NT,8C,80W No No Yes
Intel® Xeon® D - 2712T,4C,65W No No Yes

PCI-E Card Support

Table 8. PCI-E Card Support Thermal Limitation (NAF Configurations) for XR4000r The table describes PCI-E Card Support Thermal Limitation (RAF Configurations) for XR4000r chassis:
TDP (W) NAF Configurations
Edge 2 (Max 55°C) Edge 1 (Max 50°C) ASHRAE A4 (Max 45°C)
nvidia GPGPU A2 Not Supported Yes
nvidia GPGPU A30 Yes
Table 9. M.2 Support Thermal Limitation for XR4000r Chassis (RAF Configurations) The table describes PCI-E Card Support Thermal Limitation (NAF Configurations) for XR4000r chassis:
M.2 Type Riser Module BOSS Module AIC Card
Edge 2 (Max 55°C) Edge 1 (Max 50°C) ASHRAE A4 (Max 45°C) Edge 2 (Max 55°C) Edge 1 (Max 50°C) ASHRAE A4 (Max 45°C) Edge 2 (Max 55°C) Edge 1 (Max 50°C) ASHRAE A4 (Max 45°C)
Micron 480GB Not Supported Not Supported Yes Not Supported Not Supported Yes Not Supported Not Supported Yes
Micron 800GB Not Supported Not Supported Yes Not Supported Not Supported Yes Not Supported Not Supported Yes
Micron 960GB Not Supported Not Supported Yes Not Supported Not Supported Yes Not Supported Not Supported Yes
Micron 1.92TB Not Supported Not Supported Yes No No No Not Supported Not Supported Yes
Micron 3.84TB Not Supported Not Supported Yes No No No Not Supported Not Supported Yes
Hynix 480GB Not Supported Not Supported Yes Not Supported Not Supported Yes Not Supported Not Supported Yes
Hynix 800GB Not Supported Not Supported Yes Not Supported Not Supported Yes Not Supported Not Supported Yes
Hynix 960GB Not Supported Not Supported Yes Not Supported Not Supported Yes Not Supported Not Supported Yes
Hynix 1.92TB Not Supported Not Supported Yes No No No Not Supported Not Supported Yes
Hynix 3.84BT Not Supported Not Supported Yes No No No Not Supported Not Supported Yes