Technical Specifications
| Processor | ||
|---|---|---|
| Processor type | One or two Intel Xeon processors E5-2400 v2 product family | |
| Expansion Bus | |||
|---|---|---|---|
| Bus type | PCI Express Generation 2 and 3 | ||
| Expansion slots using riser card: | |||
| Riser 1 | (Slot 1) One half-height, half length x4 link (for single processor) or One half-height, half length x16 link (for two processors) | ||
| Riser 2 | (Slot 2) One full-height, half-length x16 link | ||
| Memory | ||
|---|---|---|
| Architecture | 800 MT/s, 1066 MT/s, 1333 MT/s, or 1600 MT/s DDR3 registered, unbuffered or load-reduced Error Correcting Code (ECC) DIMMs | |
| Support for advanced ECC or memory optimized operation | ||
| Memory module sockets | Twelve 240-pin | |
| Memory module capacities | ||
| RDIMMs | 4 GB (single-rank), 8 GB (single- and dual-rank), 16 GB (dual-rank), and 32 GB (quad-rank) | |
| UDIMMs | 4 GB (single- rank) and 8 GB (single- and dual-rank) | |
| Minimum RAM |
4 GB with one processor 8 GB with two processors |
|
| Maximum RAM | 192 GB with one processor | |
| 384 GB with two processors | ||
| Drives | ||
|---|---|---|
| Hard drives |
Up to four 2.5 inch hot-swappable SAS or SATA SSDs.
|
|
| Connectors | ||
|---|---|---|
| Back | ||
| NIC | Two 10/100/1000 Mbps | |
| Serial | 9-pin, DTE, 16550-compatible | |
| USB | Two 4-pin, USB 2.0-compliant | |
| Video | 15-pin VGA | |
| iDRAC7 | One optional 1 GbE Ethernet | |
| External vFlash card | One flash memory card slot with iDRAC
Enterprise card
|
|
| Front | ||
| USB | Two 4-pin, USB 2.0-compliant | |
| Video | 15-pin VGA | |
| Internal | ||
| USB | One 4-pin, USB 2.0-compliant | |
| Internal Dual SD Module | Two optional flash memory card slots
with the internal SD module
|
|
| Video | ||
|---|---|---|
| Video type | Integrated Matrox G200 with iDRAC7 | |
| Video memory | 16 MB shared with iDRAC application memory | |
| Power | ||
|---|---|---|
| AC Power Supply (per power supply) | ||
| Wattage | 550 W | |
Heat dissipation
|
2132 BTU/hr maximum (redundant, 550 W power supply) |
|
Voltage
|
100–240 V AC, autoranging, 50/60 Hz | |
| Battery | ||
| Coin-cell battery | 3 V CR2032 Lithium coin cell | |
| Expanded Operating Temperature | ||
|---|---|---|
|
||
| < 10% of annual operating hours | 5 °C to 40 °C at 5% to 85% RH with 26
°C dew point.
For temperatures between 35 °C and 40 °C, de-rate maximum allowable dry bulb temperature by 1 °C per 175 m above 950 m (1 °F per 319 ft). |
|
| < 1% of annual operating hours | –5 °C to 45 °C at 5% to 90% RH with 26
°C dew point.
For temperatures between 40 °C and 45 °C, de-rate maximum allowable dry bulb temperature by 1 °C per 125 m above 950 m (1 °F per 228 ft). |
|
| Expanded Operating Temperature Restrictions |
|
|
| Environmental | ||
|---|---|---|
|
||
| Temperature | ||
| Maximum Temperature Gradient (Operating and Storage) | 20 °C/h (36 °F/h) | |
| Storage Temperature Limits | –40 °C to 65 °C (–40 °F to 149 °F) | |
| Temperature (Continuous Operation) | ||
| Temperature Ranges (for altitude less than 950 m or 3117 ft) | 10 °C to 45 °C (50 °F to 113 °F) with no direct sunlight on the equipment. | |
| Humidity Percentage Range | 10% to 80% Relative Humidity with 26 °C (78.8 °F) maximum dew point. | |
| Relative Humidity | ||
| Storage | 5% to 95% RH with 33 °C (91 °F) maximum dew point. Atmosphere must be non-condensing at all times. | |
| Vibration | ||
| Operating | MIL-STD-810G, Method 514.6, Figure 514.6D-9, 0.00220783 g2/Hz at 10-500 Hz (overall 1.04 Grms), 1 hour per axis | |
| Non-operating | MIL-STD-810G, Method 514.6, Figure 514.6, Procedure I, Category 4, Figure 514.6C-1 (US highway truck vibration), Vertical: 5-500 Hz at 1.04 Grms, Transverse: 5-500 Hz at 0.204 Grms, Longitudinal: 5-500 Hz at 0.740 Grms, 1 hour per axis | |
| Shock | ||
| Operating | MIL-STD-810G, Method 516.6, Procedure I, 20G for rotational hard drives and 40G for solid state drives, 11 ms, saw tooth, 3 shocks, +/- per axis | |
| Non-operating | MIL-STD-810G, Method 516.6, Procedure V, 40G, 11 ms, saw tooth, 3 shocks, +/- per axis | |
| Maximum Altitude | ||
| Operating |
3048 m ( 10,000 ft) per IEC 60950-1. 4572 m (15,000 ft) per MIL-STD-810G, Method 500.5, Procedure II |
|
| Storage | 12,192 m (40,000 ft). | |
| Operating Altitude De-rating | ||
| Up to 35 °C (95 °F) | Maximum temperature is reduced by 1 °C/300 m (1 °F/547 ft) above 950 m (3,117 ft). | |
| 35 °C to 40 °C (95 °F to 104 °F) | Maximum temperature is reduced by 1 °C/175 m (1 °F/319 ft) above 950 m (3,117 ft). | |
| 40 °C to 45 °C (104 °F to 113 °F) | Maximum temperature is reduced by 1 °C/125 m (1 °F/228 ft) above 950 m (3,117 ft). | |
Particulate
Contamination
|
||
Air Filtration
|
Data center air filtration as defined
by ISO Class 8 per ISO 14644-1 with a 95% upper confidence limit.
|
|
Conductive Dust
|
Air must be free of conductive dust, zinc whiskers, or other conductive particles. | |
Corrosive Dust
|
|
|
| Gaseous Contamination | ||
|
||
| Copper Coupon Corrosion Rate | <300 Å/month per Class G1 as defined by ANSI/ISA71.04-1985. | |
| Silver Coupon Corrosion Rate | <200 Å/month as defined by AHSRAE TC9.9. | |