Dell EMC PowerEdge XR11: технические характеристики и спецификации

Chassis dimensions

Figure 1. Chassis dimensions
This image shows chassis dimension for the PowerEge XR11 system.
Table 1. Chassis dimensionsThis table provides the dimensions of the system:
Drives Xa Xb Y Za Zb Zc
4 x 2.5-inch drives with Rear Accessed configuration 482.6 mm (19 inches)434.0 mm (17 inches)42.8 mm (1.68 inches)31 mm (1.22 inches)Without bezel

45.0 mm (1.77 inches)With bezel

400 mm (15.74 inches)

Ear to rear wall

432 mm (17 inches)

Ear to outermost part of rear wall

4 x 2.5-inch drives with Front Accessed configuration 482.6 mm (19 inches)434.0 mm (17 inches)42.8 mm (1.68 inches)63 mm (2.48 inches) Without bezel

Bezel is not supported

400 mm (15.74 inches)

Ear to rear wall

408 mm (16.06 inches)

System weight

Table 1. PowerEdge XR11 system weightThe table below shows the maximum weight of the PowerEdge XR11 system.
System configuration Maximum weight (with all drives/SSDs/rails/bezel)
4 x 2.5-inch system with Rear Accessed configuration 13.8 kg (30.5 pound)
4 x 2.5-inch system with Front Accessed configuration 13.6 kg (29.9 pound)

Processor specifications

Table 1. PowerEdge XR11 processor specificationsThis table provides processor specifications for the system.
Supported processor Number of processor supported
3rd Generation Intel Xeon Scalable processor with up to 36 cores One

PSU specifications

The PowerEdge XR11 system supports up to two AC or DC power supply units (PSUs).

Table 1. PSU specificationsThe table lists the specifications for 800 W, 1100 W, 1400 W power supplies.
PSU Class Heat dissipation (maximum) Frequency Voltage AC DC Current
High line 200–240 V Low line 100–120 V
1400 W Mixed Mode Platinum 5459 BTU/hr 50/60 Hz 100–240 V AC, autoranging 1400 W 1050 W NA 12 A–8 A
NA 5459 BTU/hr NA 240 V DC NA NA 1400 W 6.6 A
1100 W NA 4266 BTU/hr NA -48-(-60) V DC, autoranging NA NA 1100 W 27 A
800 W Mixed Mode Platinum 3139 BTU/hr 50/60 Hz 100–240 V AC, autoranging 800 W 800 W NA 9.2 A–4.7 A
NA 3139 BTU/hr NA 240 V DC NA NA 800 W 3.8 A
NOTE:This system is also designed to connect to the IT power systems with a phase-to-phase voltage not exceeding 240 V.
NOTE:Heat dissipation is calculated using the PSU wattage rating.
NOTE:When selecting or upgrading the system configuration, to ensure optimum power utilization, verify the system power consumption with the Dell Enterprise Infrastructure Planning Tool available at Dell.com/ESSA.

Supported operating systems

The PowerEdge XR11 system supports the following operating systems:

  • Canonical Ubuntu Server LTS
  • VMware ESXi
  • Microsoft Windows Server with Hyper-V
  • Red Hat Enterprise Linux
  • SUSE Linux Enterprise Server
  • VMware ESXi
  • RHEL Realtime

For more information, go to www.dell.com/ossupport.

Cooling fans specifications

The PowerEdge XR11 system supports six Very High Performance fans and requires all six fans to be installed.

NOTE: For more information about the fan support configuration or matrix, see Thermal restriction matrix.

System battery specifications

The PowerEdge XR11 system supports CR 2032 3.0-V lithium coin cell system battery.

Expansion card riser specifications

The PowerEdge XR11 system supports up to three PCI express (PCIe) Gen 4 expansion cards.
Table 1. Expansion card slots supported on the system boardThis table provides information about the expansion card slots that are supported on the system.
PCIe slot Risers PCIe slot height PCIe slot length PCIe slot width
Slot 1 Riser 1B* Low Profile Half Length x8
Slot 1 Riser 1A** Low Profile Half Length x16
Slot 2 Riser 2 Full height Half length x16
Slot 3 Riser 3 Full height Half length x16
NOTE:* indicates that the PCIe connector on Riser 1B is mechanically a x16 slot.
NOTE:** indicates that the Riser 1A is supported only on Front Accessed configuration.
CAUTION: Do not install GPUs, network cards, or other PCIe devices on your system that are not validated and tested by Dell. Damage caused by unauthorized and invalidated hardware installation will null and void the system warranty.
WARNING: Consumer-Grade GPU should not be installed or used in the Enterprise Server products.

Memory specifications

The PowerEdge XR11 system supports the following memory specifications for optimized operation:
Table 1. Memory specificationsThe table below shows the memory specifications:
DIMM type DIMM rank DIMM capacity Single processor
Minimum RAM Maximum RAM
RDIMM Single rank 8 GB 8 GB 64 GB
Dual rank 16 GB 16 GB 128 GB
32 GB 32 GB 256 GB
64 GB 64 GB 512 GB
LRDIMM Quad rank 128 GB 128 GB 1024 GB
256 GB 256 GB 2048 GB
Intel Optane PMem 200 Series Single rank 128 GB 128 GB 512 GB
256 GB 256 GB 1024 GB
Table 2. Memory module socketsThe table below shows the memory module sockets for the system:
Memory module sockets Speed
8, 288-pin 3200 MT/s
Table 3. Supported Intel Optane PMem 200 Series for processor configurationsThis table lists the supported Intel Optane PMem 200 Series configurations for processor system.
Configuration Description Memory population rules
RDIMMs LRDIMM Intel Optane PMem 200 Series
Configuration 1 4 x RDIMMs, 4 x Intel Optane PMem 200 Series Processor1 {A1, A2, A3, A4} - Processor1 {A5, A6, A7, A8}
4 x LRDIMMs, 4 x Intel Optane PMem 200 Series - Processor1 {A1, A2, A3, A4} Processor1 {A5, A6, A7, A8}
Configuration 2 6 x RDIMMs, 1 x Intel Optane PMem 200 Series Processor1 {A1, A2, A3, A4, A5, A6} - Processor1 {A7}
6 x LRDIMMs, 1 x Intel Optane PMem 200 Series - Processor1 {A1, A2, A3, A4, A5, A6} Processor1 {A7}
NOTE:Memory DIMM slots are not hot pluggable.

Storage controller specifications

Table 1. PowerEdge XR11 storage controller specificationsThis table provides the controller cards supported on the system:
Internal controllers External controllers
  • PERC H755
  • PERC H345*
  • PERC H355*
  • HBA355i
  • S150
  • Boot Optimized Storage Subsystem (BOSS-S1): HWRAID 2 x M.2 SSDs
  • PERC H840
  • HBA355e
NOTE:* indicates the H355 will replace H345 from Dec'21.

Drives specifications

The PowerEdge XR11 system supports 4 x 2.5-inch SAS, SATA, or NVMe SSD drives.
NOTE: Due to thermal restriction Samsung PM1725B/PM1735 and Kioxia CD6/CM6 NVMe drives are not supported.
NOTE:NVMe drives are not supported for Front Accessed configurations with Riser 1A.

USB ports specifications

Table 1. PowerEdge XR11 USB ports specifications for Rear Accessed configuration The following table shows the USB specifications :
Front Rear Internal
USB port type No. of ports USB port type No. of ports USB port type No. of ports
USB 2.0-compliant port One USB 2.0-compliant port One Internal USB 3.0-compliant port. One
Micro-USB 2.0-compliant port for iDRAC Direct One USB 3.0-compliant ports One
Table 2. PowerEdge XR11 USB ports specifications for Front Accessed configurationThe following table shows the USB specifications :
Front Internal
USB port type No. of ports USB port type No. of ports
USB 2.0-compliant port One Internal USB 3.0-compliant port One
USB 3.0-compliant ports One
Micro-USB 2.0-compliant port for iDRAC Direct One
NOTE:Internal USB port is available on Riser 1B and USB memory key is supported..
NOTE:USB memory key is not supported on Riser 1A.

GPU specifications

The PowerEdge XR11 system supports up to two 70 W (Single Width) GPUs.

Serial connector specifications

The PowerEdge XR11 system supports one 9-pin connector Data Terminal Equipment (DTE) 16550-compliant serial connector located on the rear of the Rear Accessed configuration and on the front of the Front Accessed configuration.

NIC port specifications

The PowerEdge XR11 system supports 4 embedded LOM ports that provide 4x 25GbE SFP+. These ports support 10GbE and 25GbE.

There is also a dedicated iDRAC management port that supports 1GbE.

VGA port specification

The PowerEdge XR11 system supports one DB-15 Video Graphics Array (VGA) port on the rear of the Rear Accessed configuration and one DB-15 VGA port on the front of the Front Accessed configuration.

Video specifications

The PowerEdge XR11 system supports integrated Matrox G200 graphics controller with 16 MB of video frame buffer.
Table 1. Supported video resolution options for the systemThis table describes the supported front video resolution options for the system.
Resolution Refresh rate (Hz) Color depth (bits)
1024 x 768 60 8, 16, 32
1280 x 800 60 8, 16, 32
1280 x 1024 60 8, 16, 32
1360 x 768 60 8, 16, 32
1440 x 900 60 8, 16, 32
1600 x 900 60 8, 16, 32
1600 x 1200 60 8, 16, 32
1680 x 1050 60 8, 16, 32
1920 x 1080 60 8, 16, 32
1920 x 1200 60 8, 16, 32

Environmental specifications

The PowerEdge XR11 system operates in these environmental categories: ASHRAE A2/A3/A4 and Rugged.
NOTE:For additional information about environmental certifications, see the Product Environmental Datasheet that is located with the Documentation > Regulatory Information on www.dell.com/support/home.
Table 1. Continuous operation specifications for ASHRAE A2 This table describes the operational climatic range for category A2.
Allowable continuous operations
Temperature range for altitudes <= 900 m (<= 2953 ft) 10–35°C (50–95°F) with no direct sunlight on the equipment
Humidity percent range (non-condensing at all times) 8% RH with -12°C minimum dew point to 80% RH with 21°C (69.8°F) maximum dew point
Operational altitude de-rating Maximum temperature is reduced by 1°C/300 m (1.8°F/984 Ft) above 900 m (2953 Ft).
Table 2. Continuous operation specifications for ASHRAE A3 This table describes the operational climatic range for category A3.
Allowable continuous operations
Temperature range for altitudes <= 900 m (<= 2953 ft) 5–40°C (41–104°F) with no direct sunlight on the equipment
Humidity percent range (non-condensing at all times) 8% RH with -12°C minimum dew point to 85% RH with 24°C (75.2°F) maximum dew point
Operational altitude de-rating Maximum temperature is reduced by 1°C/175 m (1.8°F/574 Ft) above 900 m (2953 Ft).
Table 3. Continuous operation specifications for ASHRAE A4 This table describes the operational climatic range for category A4.
Allowable continuous operations
Temperature range for altitudes <= 900 m (<= 2953 ft) 5–45°C (41–113°F) with no direct sunlight on the equipment
Humidity percent range (non-condensing at all times) 8% RH with -12°C minimum dew point to 90% RH with 24°C (75.2°F) maximum dew point
Operational altitude de-rating Maximum temperature is reduced by 1°C/125 m (1.8°F/410 Ft) above 900 m (2953 Ft).
Table 4. Continuous operation specifications for Rugged This table describes the operational climatic range for category A4.
Allowable continuous operations
Temperature range for altitudes <= 900 m (<= 2953 ft) (-5)–55°C (23–131°F) with no direct sunlight on the equipment
Humidity percent range (non-condensing at all times) 8% RH with -12°C minimum dew point to 90% RH with 24°C (75.2°F) maximum dew point
Operational altitude de-rating Maximum temperature is reduced by 1°C/80 m (1.8°F/410 Ft) above 900 m (2953 Ft).
Table 5. Common environmental specifications for ASHRAE A2, A3, A4, and Rugged This table describes the shared requirements across all categories.
Allowable continuous operations
Maximum temperature gradient (applies to both operation and non-operation). 20°C in an hour* (36°F in an hour) and 5°C in 15 minutes (41°F in 15 minutes), 5°C in an hour* (41°F in an hour) for tape
NOTE:* - Per ASHRAE thermal guidelines for tape hardware, these are not instantaneous rates of temperature change.
Non-operational temperature limits -40°C to 65°C (-104°F to 149°F).
Non-operational humidity limits 5% to 95% RH with 27°C (80.6°F) maximum dew point
Maximum non-operational altitude 12,000 meters (39,370 feet).
Maximum operational altitude 3,048 meters (10,000 feet).
Table 6. Maximum vibration specifications for the system This table shows the maximum vibration specifications for the system.
Maximum vibration Specifications
Operating MIL-STD-810H, Method 514.8, 1.04 Grms, 2-500 Hz, Random Vibration, Figure 514.8D-11
Storage
  • MIL-STD-810H, Method 514.8, Category 4, Figure 514.8C-2, 10 -500 Hz, 60 minutes/axis
  • MIL-STD-810H, Method 514.8, Category 24, Figure 514.8E-1, 20-2000 Hz, 60 minutes/axis
Table 7. Maximum shock pulse specifications for the systemThe maximum shock specification of an operational system is six consecutively performed shock pulses in the positive and negative x, y, and z axis of 40 G for up to 2.3 ms. The maximum shock specification of a nonoperational system is six consecutively performed shock pulses in the positive and negative x, y, and z axis (one pulse on each side of the system) of 71 G for up to 2 ms.
Maximum shock pulse Specifications
Operating
  • MIL-STD-810H, Method 516.8, Procedure I, 11ms, 20G
  • MIL-STD-810H, Method 516.8, Procedure I, 11ms, 40G (SSD),
Operating (Navy) MIL-DTL-901E, Grade A, Class 2, Type A, in approved military transit case
Storage
  • MIL-STD-810H, Method 516.8, Procedures I, 11 ms, 40G (with SSD).
  • MIL-STD-810H, Method 516.8, Procedures I, 11 ms, 40G

Particulate and gaseous contamination specifications

The following table defines the limitations that prevent any equipment damage or failure from particulate and gaseous contamination. If the levels of particulate or gaseous pollution exceed the specified limitations and results in equipment damage or failure, you must rectify the environmental conditions. Remediation of environmental conditions is the responsibility of the customer.
Table 1. Particulate contamination specifications Air filtration specification: Data center air filtration as defined by ISO Class 8 per ISO 14644-1 should have a 95% upper confidence limit. This condition applies only to data center environments. Air filtration requirements do not apply to IT equipment designed to be used outside a data center, in environments such as an office or factory floor. Air entering the data center must have MERV11 or MERV13 filtration. Conductive dust specification: Air must be free of conductive dust, zinc whiskers, or other conductive particles. This condition applies to data center and non-data center environments. Corrosive dust specification: Air must be free of corrosive dust. Residual dust present in the air must have a deliquescent point less than 60% relative humidity. This condition applies to data center and non-data center environments.
Particulate contamination Specifications
Air filtration Data center air filtration as defined by ISO Class 8 per ISO 14644-1 with a 95% upper confidence limit.
NOTE:This condition applies to data center environments only. Air filtration requirements do not apply to IT equipment designed to be used outside a data center, in environments such as an office or factory floor.
NOTE:Air entering the data center must have MERV11 or MERV13 filtration.

Conductive dust

Air must be free of conductive dust, zinc whiskers, or other conductive particles.
NOTE:This condition applies to data center and non-data center environments.

Corrosive dust

  • Air must be free of corrosive dust.
  • Residual dust present in the air must have a deliquescent point less than 60% relative humidity.
NOTE:This condition applies to data center and non-data center environments.
Table 2. Gaseous contamination specifications The copper coupon corrosion rate is <300 Å/month per Class G1 as defined by ANSI/ISA71.04-2013. The silver coupon corrosion rate is <200 Å/month as defined by ANSI/ISA71.04-2013.
Gaseous contamination Specifications
Copper Coupon Corrosion rate <300 Å/month per Class G1 as defined by ANSI/ISA71.04-2013
Silver Coupon Corrosion rate <200 Å/month as defined by ANSI/ISA71.04-2013
NOTE:Maximum corrosive contaminant levels measured at ≤50% relative humidity.

Rugged certifications and specifications

The PowerEdge XR11 supports the rugged environment space for temperatures up to 55°C through custom configurations. These configurations are geared for the Telecom (or Telco) and Military industries and hence meet industry-specific standards in addition to the maximum temperature requirement of 55°C. The Telco configurations will be tested to the NEBS requirements outlined in the GR-63 and GR-1089 Telcordia specifications. The Military configurations will be tested to: MIL-STD-810H, MIL-DTL-901E and MIL-STD-461G.
Table 1. Rugged Certifications and Specifications
Certifications Specifications
Operating Temps -5°C to 55°C

55°C continuous operation per MIL 810H Method 501.7 Proc

-5°C continuous operation per MIL 810H Method 502.7 Proc

Operational Shock MIL-STD-810H, Method 516.8, Procedure I, 11ms, 40G (SSD)
Operational Shock (Navy) MIL-DTL-901E, Grade A, Class 2, Type A, in approved military transit case
Non-Operational Shock MIL-STD-810H, Method 516.8, Procedures V, 11 ms, 40G (with SSD)
Operational Vibration MIL-STD-810H, Method 514.8, 1.04 Grms, 2-500Hz, Random Vibration, Figure 514.8D-11 with SSD
Non-Operational Vibration MIL-STD-810H, Method 514.8, Category 4, Figure 514.8C-2, 5-500 Hz, 60 minutes/axis with SSD

MIL-STD-810H, Method 514.8, Category 24, Figure 514.8E-1, 20-2000Hz, 60 minutes/axis with SSD

Operational Altitude MIL-STD-810H, Method 500.6, Proc. II (Operational, Air carriage) 15,000ft for 1 hour after stabilization
Non-Operational Altitude MIL-STD-810H, Method 500.6, Proc. I (Storage, Air transport), 40Kft for 1 hour after stabilization
Conductive/Radiative Immunity MIL-STD-461G
Sand and Dust (tested with filtered bezel) MIL-STD-810H, Method 510.7, Procedure I, Blowing dust at 25oC, 6 hours, and an additional 6 hours at 49 o C, (Climatic Category A1)

MIL-STD-810H, Method 510.7, Procedure II, Blowing sand at 49 o C (Climatic Category A1) window velocity of 29 m/s, sand concentration of 2.2 g/m3, 6 hours

NEBS Level 3 GR-63-CORE and GR-1089-CORE

Thermal restriction matrix

Table 1. Thermal restriction matrix for processor and fansThis table describes the thermal restriction for processor and fans.
Configuration / Processor TDP Front and Rear Accessed configuration with filtered bezel Maximum Ambient Temperature
105 W VHP fan

Std. HSK

55°C
120 W VHP fan

Std. HSK

55°C
135 W VHP fan

Std. HSK

55°C
140 W VHP fan

Std. HSK

55°C
150 W VHP fan

Std. HSK

55°C
165 W VHP fan

Ext. HSK

35°C
185 W VHP fan

Ext. HSK

35°C
205 W VHP fan

Ext. HSK

35°C
225 W VHP fan

Ext. HSK

35°C
NOTE: A few specific processors having TDP greater than 150 W, can support ambient temperature greater than 35°C.
Table 2. Label referenceThis table describes the label references used in the restriction tables.
Label Description
VHP fan Very High Performance fan
Std. Standard
Ext. Extended
HSK Heat sink
Table 3. Thermal restriction matrix for GPUsThis table describes the thermal restriction for GPUs.
Rear Accessed Configuration Front Accessed Configuration
GPU Maximum Ambient Temperature Maximum Ambient Temperature
Nvidia T4 40C 50C
Nvidia A2 35C 50C

Thermal restriction for ASHRAE A3 for Rear Accessed configuration

  • Do not perform a cold startup below 5°C
  • Processor TDP greater than 150 W are not supported except for the following list:
    • 6334, 8 core, 165W
    • 6338T, 24 core, 165W
    • 6330N, 28 core, 165W
    • 6338N, 32 core, 185W
  • 128 GB or greater capacity DIMMs and Intel Optane PMem 200 Series are not supported.
  • Non-Dell qualified peripheral cards are not supported.
  • PCIe SSD is not supported.
  • BOSS M.2 is not supported.
  • High temperature spec 85°C active optics cables are required.
  • PERC adapter with battery is not supported except for H755.
  • NVMe drive is not supported.
  • CX-6 100GB NIC card is not supported except for CX-6 DX.
  • SAS SSD is not supported.

Thermal restriction for ASHRAE A4 for Rear Accessed configuration

  • Do not perform a cold startup below 5°C
  • Processor TDP greater than 150 W are not supported except for the following list:
    • 6334, 8 core, 165W
    • 6338T, 24 core, 165W
    • 6330N, 28 core, 165W
    • 6338N, 32 core, 185W
  • 128 GB or greater capacity DIMMs and Intel Optane PMem 200 Series are not supported.
  • Non-Dell qualified peripheral cards are not supported.
  • PCIe SSD is not supported.
  • BOSS M.2 is not supported.
  • High temperature spec 85°C active optics cables are required.
  • PERC adapter with battery is not supported.
  • NVMe drive is not supported.
  • CX-6 100GB NIC card is not supported except for CX-6 DX.
  • SAS SSD is not supported.

Thermal restriction for Rugged for Rear Accessed configuration

  • Do not perform a cold startup below 5°C
  • Processor TDP greater than 150 W are not supported except for the following list:
    • 6338T, 24 core, 165W
    • 6330N, 28 core, 165W
  • 128 GB or greater capacity DIMMs and Intel Optane PMem 200 Series are not supported.
  • Two PSUs are required in redundant mode. System performance may be reduced in the event of a PSU failure.
  • Non-Dell qualified peripheral cards are not supported.
  • PCIe SSD is not supported.
  • BOSS M.2 is not supported.
  • High temperature spec 85°C active optics cables are required.
  • PERC adapter with battery is not supported.
  • NVMe drive is not supported.
  • CX-6 100GB NIC card is not supported except for CX-6 DX.
  • SAS SSD is not supported.

Thermal restriction for ASHRAE A3 for Front Accessed configuration

  • Do not perform a cold startup below 5°C
  • Processor TDP greater than 150 W are not supported except for the following list:
    • 6334, 8 core, 165W
    • 6338T, 24 core, 165W
    • 6330N, 28 core, 165W
    • 6338N, 32 core, 185W
  • 128 GB or greater capacity DIMMs and Intel Optane PMem 200 Series are not supported.
  • Non-Dell qualified peripheral cards are not supported.
  • PCIe SSD is not supported.
  • BOSS M.2 greater than 480 GB is not supported.
  • NVMe drive is not supported.
  • SAS SSD is not supported.

Thermal restriction for ASHRAE A4 for Front Accessed configuration

  • Do not perform a cold startup below 5°C
  • Processor TDP greater than 150 W are not supported except for the following list:
    • 6334, 8 core, 165W
    • 6338T, 24 core, 165W
    • 6330N, 28 core, 165W
    • 6338N, 32 core, 185W
  • 128 GB or greater capacity DIMMs and Intel Optane PMem 200 Series are not supported.
  • Non-Dell qualified peripheral cards are not supported.
  • PCIe SSD is not supported.
  • BOSS M.2 greater than 480 GB is not supported.
  • NVMe drive is not supported.
  • SAS SSD is not supported.

Thermal restriction for Rugged for Front Accessed configuration

  • Do not perform a cold startup below 5°C
  • Processor TDP greater than 150 W are not supported except for the following list:
    • 6338T, 24 core, 165W
    • 6330N, 28 core, 165W
    • 6338N, 32 core, 185W
  • 128 GB or greater capacity DIMMs and Intel Optane PMem 200 Series are not supported.
  • Non-Dell qualified peripheral cards are not supported.
  • PCIe SSD is not supported.
  • BOSS M.2 greater than 480 GB is not supported.
  • NVMe drive is not supported.
  • SAS SSD is not supported.
  • PERC adapter with battery is not supported except for H755.

Other Thermal Restrictions

  • DIMM blanks are required on empty slots.
  • HDD blanks are required on empty slots.
  • PCIe blank is required on empty slot 1.
  • Processor TDP greater than 150 W are not supported for Riser 1A configuration except for 6338N, 32 core, 185W processor.