Technical Specifications
| Processor | ||
|---|---|---|
| Processor type | One or two Intel Xeon processor E5-2600 product family | |
| Expansion Bus | |||
|---|---|---|---|
| Bus type | PCI Express Generation 3 and 2 | ||
| Expansion slots: | |||
| (Slot 1) One full-height, full-length x8 link | |||
| (Slot 2) One full-height, full-length x16 link | |||
(Slot 3) One full-height, full-length,
x4 link
|
|||
| (Slot 4) One full-height, full-length x16 link | |||
|
|||
| (Slot 5) One full-height, full-length x16 link | |||
| (Slot 6) One full-height, full-length x8 link | |||
| (Slot 7) One full-height, full-length x16 link | |||
| Memory | ||
|---|---|---|
| Architecture | 800 MT/s, 1066 MT/s, 1333 MT/s, or 1600 MT/s DDR3 registered, unbuffered or load-reduced Error Correcting Code (ECC) DIMMs | |
| Support for advanced ECC or memory optimized operation | ||
| Memory module sockets | Twenty-four 240-pin | |
| Memory module capacities | ||
| LRDIMMs | 32 GB quad-ranked | |
| RDIMMs | 2 GB, 4 GB, 8 GB, or 32 GB single-, dual-,
or quad-ranked
16 GB single- or dual-ranked |
|
| UDIMMs | 2 GB, 4 GB, or 8 GB | |
| Minimum RAM | 2 GB with a single processor | |
| 4 GB with two processors | ||
| Maximum RAM | ||
| LRDIMMs | Up to 768 GB | |
| RDIMMs | Up to 512 GB | |
| UDIMMs | Up to 128 GB | |
| Drives | ||
|---|---|---|
| Hard drives | ||
| Four–hard-drive systems | Up to four 3.5 inch, internal, hot-swappable
SSD, SATA, or SATA hard drives
hard-drive slots 0 through 3 (hard-drive slots 4 through 7 do not support any hard drives and are installed with hard-drive blanks) |
|
| Eight–hard-drive systems | Up to eight 3.5 inch, internal, hot-swappable
SAS, SATA, or Nearline SAS hard drives
hard-drive slots 0 through 7 |
|
| Twelve–hard-drive systems | Up to twelve 3.5 inch, internal, hot-swappable
SAS, SATA, SATA SSD, or Nearline SAS hard drives
hard-drive slots 0 through 11 |
|
| Eight plus four-hard drive systems | Up to eight 3.5 inch, internal, hot-swappable SAS, SATA, SATA SSD, or Nearline SAS hard drives, and four Dell PowerEdge Express Flash devices (PCIe SSDs) | |
| Sixteen–hard-drive systems | Up to sixteen 2.5 inch, internal, hot-swappable
SAS, SATA, SATA SSD, or Nearline SAS hard drives
hard-drive slots 0 through 7 and 8 through 15 Up to sixteen 2.5 inch, internal, hot-swappable SAS, SATA hard drives and four SATA SSDs |
|
| Sixteen plus four hard-drive systems | Up to sixteen 2.5 inch, internal, hot-swappable
SAS, SATA, or SATA SSD hard drives plus four PCIe SSDs
hard-drive slots 0 through 3, 0 through 7, and 8 through 15 |
|
| Thirty two–hard-drive systems with a single PERC card | Up to thirty two 2.5 inch, internal,
hot-swappable SAS, SATA, SATA SSD, or Nearline SAS hard drives
hard-drive slots 0 through 7, 8 through 15, 16 through 23, and 24 through 31 |
|
| Thirty two–hard-drive systems with double PERC card | Up to thirty two 2.5 inch, internal,
hot-swappable SAS, SATA, SATA SSD, or Nearline SAS hard drives
hard-drive slots 0 through 7, 8 through 15, 0 through 7, and 8 through 15 |
|
| Optical drive | One optional SATA DVD-ROM drive or DVD+/-RW
drive
|
|
| Connectors | ||
|---|---|---|
| Back | ||
| NIC | Two 10/100/1000 Mbps | |
| Serial | 9-pin, DTE, 16550-compatible | |
| USB | Six Hi-Speed USB Host | |
| Video | 15-pin VGA | |
| Front | ||
| USB | Two Hi-Speed USB Host | |
| Video | 15-pin VGA
|
|
| External vFlash memory card | One vFlash memory card slot | |
| Internal | ||
| USB | One 4-pin, USB 2.0-compliant | |
| Internal Dual SD Module | Two optional flash memory card slots
with the internal SD module
|
|
| Video | ||
|---|---|---|
| Video type | Integrated Matrox G200 | |
| Video memory | 16 MB shared | |
| Expanded Operating Temperature | ||
|---|---|---|
|
||
| < 10% of annual operating hours | 5 °C to 40 °C at 5% to 85% RH with 26
°C dew point.
For temperatures between 35 °C and 40 °C, de-rate maximum allowable dry bulb temperature by 1 °C per 175 m above 950 m (1 °F per 319 ft). |
|
| < 1% of annual operating hours | –5 °C to 45 °C at 5% to 90% RH with 26
°C dew point.
For temperatures between 40 °C and 45 °C, de-rate maximum allowable dry bulb temperature by 1 °C per 125 m above 950 m (1 °F per 228 ft). |
|
| Expanded Operating Temperature Restrictions |
|
|
| Environmental | ||
|---|---|---|
|
||
| Temperature | ||
| Maximum Temperature Gradient (Operating and Storage) | 20 °C/h (36 °F/h) | |
| Storage Temperature Limits | –40 °C to 65 °C (–40 °F to 149 °F) | |
| Temperature (Continuous Operation) | ||
| Temperature Ranges (for altitude less than 950 m or 3117 ft) | 10 °C to 35 °C (50 °F to 95 °F) with no direct sunlight on the equipment. | |
| Humidity Percentage Range | 10% to 80% Relative Humidity with 26 °C (78.8 °F) maximum dew point. | |
| Relative Humidity | ||
| Storage | 5% to 95% RH with 33 °C (91 °F) maximum dew point. Atmosphere must be non-condensing at all times. | |
| Maximum Vibration | ||
| Operating | 0.26 G rms at 5 Hz to 350 Hz (all operation orientations). | |
| Storage | 1.87 G rms at 10 Hz to 500 Hz for 15 min (all six sides tested). | |
| Maximum Shock | ||
| Operating | One shock pulse in the positive z axis of 31 G for 2.6 ms in all operational orientations. | |
| Storage | Six consecutively executed shock pulses in the positive and negative x, y, and z axes (one pulse on each side of the system) of 71 G for up to 2 ms. | |
| Maximum Altitude | ||
| Operating |
3048 m ( 10,000 ft). |
|
| Storage | 12,000 m (39,370 ft). | |
| Operating Altitude De-rating | ||
| Up to 35 °C (95 °F) | Maximum temperature is reduced by 1 °C/300 m (1 °F/547 ft) above 950 m (3,117 ft). | |
| 35 °C to 40 °C (95 °F to 104 °F) | Maximum temperature is reduced by 1 °C/175 m (1 °F/319 ft) above 950 m (3,117 ft). | |
| 40 °C to 45 °C (104 °F to 113 °F) | Maximum temperature is reduced by 1 °C/125 m (1 °F/228 ft) above 950 m (3,117 ft). | |
Particulate
Contamination
|
||
Air Filtration
|
Data center air filtration as defined
by ISO Class 8 per ISO 14644-1 with a 95% upper confidence limit.
|
|
Conductive Dust
|
Air must be free of conductive dust, zinc whiskers, or other conductive particles. | |
Corrosive Dust
|
|
|
| Gaseous Contamination | ||
|
||
| Copper Coupon Corrosion Rate | <300 Å/month per Class G1 as defined by ANSI/ISA71.04-1985. | |
| Silver Coupon Corrosion Rate | <200 Å/month as defined by AHSRAE TC9.9. | |