Сегодня покупают
← Вернуться назад
Нужна помощь с конфигурацией?
Пришлите SKU, спецификацию или список требований. Специалист Apltech проверит совместимость компонентов и найдёт актуальные артикулы
Получить консультацию →

Dell PowerEdge T320 Systems: руководство по обслуживанию

Technical Specifications

Table 1. Procesor specificationsThe following table shows the processor specifications.
Processor
Processor type
  • One Intel Xeon processor E5-2400 and E5-2400 v2 product family, or
  • One Intel Xeon processor E5-1400 and E5-1400 v2 product family, or
  • One Intel Pentium processor 1400 and 1400 v2 product family
Table 2. PCIe card specificationsThe following table shows the PCIe card specifications
Expansion Bus Description
Bus type PCI Express Generation 3 and 2
Expansion slots
Slot 1 (Slot 1) One full-height, half-length x4 PCIe Gen2 card slot connected to Platform Controller Hub (PCH)
Slot 2 (Slot 2) One full-height, full-length x1 PCIe Gen2 card slot connected to PCH
Slot 3 (Slot 3) One full-height, full-length x16 PCIe Gen3 card slot connected to processor
Slot 4 (Slot 4) One full-height, full-length x4 PCIe Gen3 card slot connected to processor
Slot 5 (Slot 5) Not applicable
Slot 6 (Slot 6) One full-height, half-length x4 PCIe Gen3 card slot connected to processor
Table 3. Memory specificationsThe following table shows the memory specs.
Memory Description
Architecture 800 MT/s, 1066 MT/s, 1333 MT/s, or 1600 MT/s DDR3 registered or unbuffered Error Correcting Code (ECC) DIMMs
Support for advanced ECC or memory optimized operation
Memory module sockets Six 240-pin
Memory module capacities
RDIMMs 2 GB (single-rank), 4 GB (single- and dual-rank), 8 GB (single- and dual-rank), 16 GB (dual-rank), and 32 GB (quad-rank)
UDIMMs 2 GB (single-rank) and 4 GB (single- and dual-rank)
Minimum RAM 2 GB
Maximum RAM
RDIMMs 192 GB
UDIMMs 24 GB
Table 4. Hard drive specificationsThe following table shows the hard drive specifications.
Drives Description
Four hard-drive systems Up to four 3.5 inch, internal, cabled SATA, nearline SAS, or SAS hard drives.
Eight hard-drive systems Up to eight 3.5 inch, internal, hot-swappable SATA, nearline SAS, SAS hard drives.
NOTE:2.5 inch drives in 3.5 inch carriers are supported for SAS, SATA SSD or SAS SSD drives.
Sixteen hard-drive systems Up to sixteen 2.5 inch, internal, hot-swappable SATA, nearline SAS, SAS , SAS SSD, or SATA SSD drives.
Optical drive Up to two optional SATA DVD-ROM drive or DVD+/-RW drive.
NOTE:If your system is installed with a double-width GPU card, the system supports only one 5.25 inch removable media storage device.
Tape drive One optional 5.25 inch tape drive.
NOTE:If your system is installed with a double-width GPU card, the system supports only one 5.25 inch removable media storage device.
Table 5. Ports and connectors specificationsThe following table shows the ports and connectors specifications.
Connectors Description
Back
NIC Two 10/100/1000 Mbps
Serial 9-pin, DTE, 16550-compatible
USB Six 4-pin USB 2.0-compliant
Video 15-pin VGA
iDRAC 7 One iDRAC 7 port
SD vFlash One SD vFlash card slot
Front
USB Two 4-pin USB Host
Video 15-pin VGA, for systems in rack mode only
Internal
USB One 4-pin, USB 2.0-compliant
Internal Dual SD Module Two optional flash memory card slots with the internal SD module
NOTE:One card slot is dedicated for redundancy.
Table 6. Video specificationsThe following table shows the video specifications.
Video Description
Video type Integrated Matrox G200
Video memory 16 MB shared
Table 7. Expanded operating temperatureThe following table shows the expanded operating temperature.
Expanded Operating Temperature Description
NOTE:When operating in the expanded temperature range, system performance may be impacted.
NOTE:When operating in the expanded temperature range, ambient temperature warnings may be reported on the LCD and in the System Event Log.
< 10% of annual operating hours 5 °C to 40 °C at 5% to 85% RH with 26 °C dew point.
NOTE:Outside the standard operating temperature (10 °C to 35 °C), the system can operate down to 5 °C or up to 40 °C for a maximum of 10% of its annual operating hours.

For temperatures between 35 °C and 40 °C, de-rate maximum allowable dry bulb temperature by 1 °C per 175 m above 950 m (1 °F per 319 ft).

< 1% of annual operating hours –5 °C to 45 °C at 5% to 90% RH with 26 °C dew point.
NOTE:Outside the standard operating temperature (10 °C to 35 °C), the system can operate down to –5 °C or up to 45 °C for a maximum of 1% of its annual operating hours.

For temperatures between 40 °C and 45 °C, de-rate maximum allowable dry bulb temperature by 1 °C per 125 m above 950 m (1 °F per 228 ft).

Expanded Operating Temperature Restrictions
  • Both the internal cooling fan and the external cooling fan must be installed.
  • The operating temperature specified is for a maximum altitude of 30482000 m (10,0006560 ft).
  • GPU is not supported.
  • Non-redundant power supplies are not supported.
  • Non Dell qualified peripheral cards and/or peripheral cards greater than 25 W are not supported.
Table 8. Environmental specificationsThe following table shows the environmental specs.
Environmental Description
NOTE:For additional information about environmental measurements for specific system configurations, see dell.com/environmental_datasheets.
Temperature
Maximum Temperature Gradient (Operating and Storage) 20 °C/h (36 °F/h)
Storage Temperature Limits –40 °C to 65 °C (–40 °F to 149 °F)
Relative Humidity
Storage 5% to 95% RH with 33 °C (91 °F) maximum dew point. Atmosphere must be non-condensing at all times.
Temperature (Continuous Operation)
Temperature Ranges (for altitude less than 950 m or 3117 ft) 10 °C to 35 °C (50 °F to 95 °F) with no direct sunlight on the equipment.
Humidity Percentage Range 10% to 80% Relative Humidity with 26 °C (78.8 °F) maximum dew point.
Maximum Vibration
Operating 0.26 Grms at 5 Hz to 350 Hz (all operation orientations).
Storage 1.87 Grms at 10 Hz to 500 Hz for 15 min (all six sides tested).
Maximum Shock
Operating One shock pulse in the positive z axis of 31 G for 2.6 ms in all operational orientations.
Storage Six consecutively executed shock pulses in the positive and negative x, y, and z axes (one pulse on each side of the system) of 71 G for up to 2 ms.
Maximum Altitude
Operating

3,0482000 m (10,0006560 ft)

Storage 12,000 m (39,370 ft).
Operating Altitude De-rating
Up to 35 °C (95 °F) Maximum temperature is reduced by 1 °C/300 m (1 °F/547 ft) above 950 m (3,117 ft).
35 °C to 40 °C (95 °F to 104 °F) Maximum temperature is reduced by 1 °C/175 m (1 °F/319 ft) above 950 m (3,117 ft).
40 °C to 45 °C (104 °F to 113 °F) Maximum temperature is reduced by 1 °C/125 m (1 °F/228 ft) above 950 m (3,117 ft).
Particulate Contamination
NOTE:This section defines the limits to help avoid IT equipment damage and/or failure from particulates and gaseous contamination. If it is determined that levels of particulates or gaseous pollution are beyond the limits specified below and are the reason for the damage and/or failures to your equipment, it may be necessary for you to re-mediate the environmental conditions that are causing the damage and/or failures. Re-mediation of environmental conditions will be the responsibility of the customer.
Air Filtration
NOTE:Applies to data center environments only. Air filtration requirements do not apply to IT equipment designed to be used outside a data center, in environments such as an office or factory floor.
Data center air filtration as defined by ISO Class 8 per ISO 14644-1 with a 95% upper confidence limit.
NOTE:Air entering the data center must have MERV11 or MERV13 filtration.
Conductive Dust
NOTE:Applies to data center and non-data center environments.
Air must be free of conductive dust, zinc whiskers, or other conductive particles.
Corrosive Dust
NOTE:Applies to data center and non-data center environments.
  • Air must be free of corrosive dust.
  • Residual dust present in the air must have a deliquescent point less than 60% relative humidity.
Gaseous Contamination
NOTE:Maximum corrosive contaminant levels measured at ≤50% relative humidity.
Copper Coupon Corrosion Rate <300 Å/month per Class G1 as defined by ANSI/ISA71.04-1985.
Silver Coupon Corrosion Rate <200 Å/month as defined by AHSRAE TC9.9.