Chassis dimensions

| System | X | Xa | Y | Ya | Yb | Z | Za | Zb |
|---|---|---|---|---|---|---|---|---|
PowerEdge T430 | 304.5 mm (11.99 inches) | 218 mm (8.58 inches) | 471.3 mm (18.55 inches) | 430.3 mm (16.94 inches) | 443.3 mm (17.45 inches) | 594.82 mm (23.42 inches) | 578.42 mm (22.77 inches) | 542.2 mm (21.35 inches) |
Chassis weight
| System | Maximum weight |
|---|---|
| PowerEdge T430 | 36 Kg (79.37 lb) |
Processor specifications
The PowerEdge
T430 system supports up to two Intel Xeon E5-2600 v4 or Xeon E5-2600
v3 product family processors.
PSU specifications
The PowerEdge
T430 system supports up to two AC or DC redundant power supply units
(PSUs).
| PSU | Class | Heat dissipation (maximum) | Frequency | Voltage |
|---|---|---|---|---|
| 450 W AC | Bronze | 1871 BTU/hr | 50/60 Hz | 100 – 240 V AC, 6.5 A – 3.5 A, autoranging |
| 495 W AC | Platinum | 1908 BTU/hr | 100 – 240 V AC, 6.5 A – 3 A, autoranging | |
| 750 W AC | Platinum | 2891 BTU/hr | 100 – 240 V AC, 10 A – 5 A, autoranging | |
| 1100 W AC | Platinum | 4100 BTU/hr | 100 – 240 V AC, 12 A – 6.5 A, autoranging |
NOTE: Heat
dissipation is calculated using the PSU wattage rating.
NOTE: This system is also
designed to connect to the IT power systems with a phase-to-phase
voltage not exceeding 230 V.
System battery specifications
The PowerEdge
T430 system supports CR 2032 3.0-V lithium coin cell system battery.
Expansion bus specifications
The PowerEdge
T430 system supports PCI express (PCIe) generation 3 and 2 expansion
cards. The following table describes the supported expansion cards:
| PCIe Slot | Processor Connection | Height | Length | Link Width | Slot Width |
|---|---|---|---|---|---|
| 1 (Gen2) | Platform Controller Hub | Full height | Half Length | x4 | x8 |
| 2 (Gen2) | Platform Controller Hub | Full height | Half length | x1 | x1 |
| 3 (Gen3) | Processor 1 | Full height | Full length | x16 | x16 |
| 4 (Gen3) | Processor 1 | Full height | Full length | x16 | x16 |
| 5 (Gen3) | Processor 2 | Full height | Half length | x8 | x8 |
| 6 (Gen3) | Processor 2 | Full height | Half length | x8 | x8 |
NOTE: To use
PCIe slots 5 and 6, both the processors must be installed.
NOTE: The expansion card
slots are not hot-swappable.
Memory specifications
The PowerEdge
T430 system supports 1866 MT/s, 2133 MT/s or 2400 MT/s DDR4 Registered
DIMMs.
| Memory module sockets | Memory capacity | Minimum RAM | Maximum RAM |
|---|---|---|---|
| Twelve 288–pin |
|
|
|
Drive specifications
Your system supports up to four 3.5 inch cabled hard drives or eight 3.5 inch hot swappable hard drives or sixteen 2.5 inch hot swappable hard drives
Hard drives
The PowerEdge
T430 system supports:
| Drives | ||
|---|---|---|
| Hard drives | ||
| Four–hard-drive systems | Up to four 3.5 inch, internal, cabled SATA, or nearline SAS hard drives. | |
| Eight–hard-drive systems | Up to eight 3.5 inch, internal, hot-swappable
SATA, or nearline SAS hard drives. NOTE: 2.5 inch hard drives
in 3.5 inch carriers are supported for SAS, and SATA SSD hard drives. |
|
| Sixteen–hard-drive systems | Up to sixteen 2.5 inch, internal, hot-swappable SATA, nearline SAS, SAS, or SATA SSD hard drives. | |
Optical drive
The PowerEdge
T430 system supports one optional SATA DVD-ROM drive or DVD+/-RW drive
or One optional slim SATA DVD-ROM drive or DVD +/-RW drive.
| Drives | ||
|---|---|---|
| Optical drive | One optional SATA DVD-ROM
drive or DVD+/-RW drive. NOTE: If your system is installed
with a double-width GPU card, the system supports only one 5.25 inch
removable media storage device. |
|
Tape drive
The PowerEdge
T430 system supports up to two optional 5.25 inch tape drive.
NOTE: If your system is installed
with a double-width GPU card, the system supports only one 5.25 inch
removable media storage device.
Serial connector
The serial
connector connects a serial device to the system. The PowerEdge T430
system supports DB-9 Serial Port connector.
Internal Dual SD Module
The PowerEdge
RT430 system supports two optional flash memory card slots with an
internal SD module.
NOTE: One card slot is dedicated for redundancy.
VGA ports
The Video
Graphic Array (VGA) port enables you to connect the system to a VGA
display. The PowerEdge T430 system with 2.5-inch and 3.5-inch hot-swappable
hard-drive chassis supports two 15-pin VGA ports on the front and
back panels. The PowerEdge T430 system with 3.5-inch cabled hard-drive
chassis supports one 15-pin VGA port on the back panel.
USB ports
The PowerEdge T430 system supports:
- USB 2.0-compliant ports and USB 3.0-complaint ports on the front and back panel
- Internal USB 3.0-compliant port
| System | Front panel | Back panel | Internal |
|---|---|---|---|
| PowerEdge T430 |
|
|
One 9-pin, USB 3.0-compliant port |
NIC ports
The PowerEdge
T430 system supports two Network Interface Controller (NIC) ports
on the back panel, which is available in the following NIC configurations:
- Two 10/100/1000 Mbps
iDRAC 8
The PowerEdge
R430 system supports one optional 1 GbE Ethernet
SD vFlash
The PowerEdge
R430 system supports one optional SD vFlash memory card
Video specifications
The PowerEdge T430 system supports Integrated Matrox G200 with iDRAC8 and 16 MB application memory.
| Resolution | Refresh Rate (Hz) | Color Depth (bit) |
|---|---|---|
640 x 480 |
60, 70 |
8, 16, 32 |
800 x 600 |
60, 75, 85 |
8, 16, 32 |
1024 x 768 |
60, 75, 85 |
8, 16, 32 |
1280 x 1024 |
60 |
8, 16, 32 |
1440 x 900 |
60 |
8, 16, 32 |
Environmental specifications
NOTE: For additional information
about environmental measurements for specific system configurations,
see Dell.com/environmental_datasheets.
| Type | Condition | Temperature or Specification |
|---|---|---|
| Temperature | ||
| Maximum Temperature Gradient (Operating and Storage) | 20 °C/h (36 °F/h) | |
| Storage Temperature Limits | –40 °C to 65 °C (–40 °F to 149 °F) | |
| Continuous operation (for altitude less than 950 m or 3117 ft) | 10 °C to 35 °C (50 °F to 95 °F) with no direct sunlight on the equipment. | |
| Relative Humidity | ||
| Storage | 5% to 95% RH with 33 °C (91 °F) maximum dew point. Atmosphere must be non-condensing at all times. | |
| Operating | 10% to 80% Relative Humidity with 29 °C (84.2 °F) maximum dew point. | |
| Maximum Vibration | ||
| Operating | 0.26 Grms at 5 Hz to 350 Hz (all operation orientations). | |
| Storage | 1.88 Grms at 10 Hz to 500 Hz for 15 minutes (all six sides tested). | |
| Maximum Shock | ||
| Operating | Six consecutively executed shock pulses in the positive and negative x, y, and z axes of 40 G for up to 2.3 ms. | |
| Storage | Six consecutively executed shock pulses in the positive and negative x, y, and z axes (one pulse on each side of the system) of 71 G for up to 2 ms. | |
| Maximum Altitude | ||
| Operating | 3,0482000 m (10,0006560 ft) |
|
| Storage | 12,000 m (39,370 ft) |
|
| Operating Altitude De-rating | ||
| Up to 35 °C (95 °F) | Maximum temperature is reduced by 1 °C/300 m (1 °F/547 ft) above 950 m (3,117 ft). | |
| 35 °C to 40 °C (95 °F to 104 °F) | Maximum temperature is reduced by 1 °C/175 m (1 °F/319 ft) above 950 m (3,117 ft). | |
| 40 °C to 45 °C (104 °F to 113 °F) | Maximum temperature is reduced by 1 °C/125 m (1 °F/228 ft) above 950 m (3,117 ft). | |
Particulate and gaseous contamination specifications
The following
table defines the limitations that help avoid any equipment damage
or failure from particulates and gaseous contamination. If the levels
of particulates or gaseous pollution exceed the specified limitations
and result in equipment damage or failure, you may need to rectify
the environmental conditions. Re-mediation of environmental conditions
is the responsibility of the customer.
NOTE: This section defines
the limits to help avoid IT equipment damage and/or failure from particulates
and gaseous contamination. If it is determined that levels of particulates
or gaseous pollution are beyond the limits specified in the following table and are
the reason for the damage and/or failures to your equipment, it may
be necessary for you to re-mediate the environmental conditions that
are causing the damage and/or failures. Re-mediation of environmental
conditions will be the responsibility of the customer.
| Particulate contamination | Specifications | |
|---|---|---|
| Air Filtration NOTE: Applies to data center environments only. Air filtration requirements
do not apply to IT equipment designed to be used outside a data center,
in environments such as an office or factory floor. |
Data center air filtration as defined
by ISO Class 8 per ISO 14644-1 with a 95% upper confidence limit. NOTE: Air entering the data
center must have MERV11 or MERV13 filtration. |
|
| Conductive Dust NOTE: Applies to data center and non-data center environments. |
Air must be free of conductive dust, zinc whiskers, or other conductive particles. | |
| Corrosive
Dust NOTE: Applies to
data center and non-data center environments. |
|
|
| Gaseous contamination | Specifications | |
|---|---|---|
| Copper Coupon Corrosion Rate | <300 Å/month per Class G1 as defined by ANSI/ISA71.04-1985. | |
| Silver Coupon Corrosion Rate | <200 Å/month as defined by AHSRAE TC9.9. | |
Expanded operating temperature
NOTE: For additional information about environmental measurements for specific system configurations, see Dell.com/environmental_datasheets.
| Condition | Temperature | |
|---|---|---|
| Continuous operation | 5 °C to 40 °C at 5% to 85% RH with 29°C dew point.
NOTE: Outside the standard operating temperature (10°C to 35°C), the system can operate continuously down to 5°C or as high as 40°C.
For temperatures between 35°C and 40°C, derate maximum allowable temperature by 1°C per 175 m above 950 m (1°F per 319 ft). |
|
| < 1% of annual operating hours | –5°C to 45°C at 5% to 90% RH with 29°C dew point.
NOTE: Outside the standard operating temperature (10 °C to 35 °C), the system can operate down to –5°C or up to 45°C for a maximum of 1% of its annual operating hours.
For temperatures between 40°C and 45°C, derate maximum allowable temperature by 1°C per 125 m above 950 m (1°F per 228 ft). |
|
| Expanded Operating Temperature Restrictions |
|
|
NOTE: When operating in the expanded temperature range, system performance may be impacted.
NOTE: When operating in the expanded temperature range, ambient temperature warnings may be reported in the System Event Log.