Chassis dimensions

| X | Y | Z |
|---|---|---|
| 176.6 mm (6.95 inches) | 335 mm (13.18 inches) | 359.5 mm (14.15 inches) |
System weight
| System configuration | Maximum weight (with all drives/SSDs) |
|---|---|
| 1x 3.5-inch drive | 8.4 Kg (18.52 lb) |
Processor specifications
| Supported processor | Model | UMA Graphics |
|---|---|---|
| Intel Xeon E | E series | Intel UHD Graphics P630 |
| Intel Core i3 | i3-9100 | Intel UHD Graphics 630 |
| Intel Pentium Gold | G5400 | Intel UHD Graphics 610 |
Supported operating systems
- Microsoft Windows Server 2016
- Microsoft Windows Server 2019
- Ubuntu 18.04 LTS
PSU specifications
The PowerEdge T40 system supports one cabled AC power supply unit (PSU).
| PSU | Class | Heat dissipation (maximum) | Frequency | Voltage | Current |
|---|---|---|---|---|---|
| 300 W AC | Bronze | 1024 BTU/hr | 50 – 60 Hz | 100 – 240 V AC, autoranging | 6A |
System fan specifications
The PowerEdge T40 system supports the following:
- One system cooling fan located at the top of the system.
- One processor cooling fan located on the heat sink.
System battery specifications
The PowerEdge T40 system supports CR 2032 3.0-V lithium coin cell system battery.
Expansion card specifications
The PowerEdge T40 system supports up to three PCI express (PCIe) Generation 3 and once PCI card.
| PCIe slot | Slot Type | Processor Connection | PCIe slot height | Maximum Add-in Card Length |
|---|---|---|---|---|
| Slot 1 | PCIe x16 Gen3 | Processor | Full Height | Half length |
| Slot 2 | PCI | Platform Controller Hub | Full Height | Half length |
| Slot 3 | PCIe x4 Gen 3 (open ended) | Platform Controller Hub | Full Height | Half length |
| Slot 4 | PCIe x4 Gen 3 (open ended) | Platform Controller Hub | Full Height | Half length |
Memory specifications
| DIMM Type | DIMM capacity | Minimum RAM | Maximum RAM |
|---|---|---|---|
| UDIMM, DDR4, ECC/Non-ECC | 8 GB | 8 GB | 32 GB |
| 16 GB | 16 GB | 64 GB |
| Memory module sockets | Speed |
|---|---|
| Four 288-pin | 2666 MT/s |
Storage controller specifications
Drives
| Configuration | Capacity |
|---|---|
| Up to 3 x 3.5-inch drive cabled SATA drives. | 1 / 2 / 4 TB |
Entry Drives : Least expensive drives used in applications where low usage and limited total number of drives are applicable. Due to restrictions on use, these drives are available in a small number of systems and configurations.
Optical drives
| Supported drive type | Supported number of drives |
|---|---|
| Slim 9.5 mm SATA DVD+/-RW drive | One |
USB ports specifications
The PowerEdge T40 system supports the USB ports mentioned below:
| Front Panel | Rear Panel |
|---|---|
|
|
NIC port specifications
Serial connector specifications
The PowerEdge T40 system supports one serial connector on the back panel, which is a 9-pin connector, Data Terminal Equipment (DTE), 16550-compliant.
DisplayPort specifications
Video specifications
- Intel UHD Graphics P630 for Intel Xeon E processor
- Intel UHD Graphics 630 for Intel Core i3 processor
- Intel UHD Graphics 610 for Intel Pentium Gold processor
Environmental specifications
| Temperature | Specifications |
|---|---|
| Storage | -40–65°C (-40–149°F) |
| Continuous operation (for altitude less than 900 m or 2953 ft) | 10–35°C (50–95°F) with no direct sunlight on the equipment |
| Fresh air | T40 do not support Fresh air (Expanded operating temperature) |
| Maximum temperature gradient (operating and storage) | 20°C/h (36°F/h) |
| Relative humidity | Specifications |
|---|---|
| Storage | 5% to 95% RH with 27°C (80.6°F) maximum dew point.
Atmosphere must be noncondensing at all times. |
| Operating | 20% to 80% RH with 21°C ( 69.8 °F ) maximum dew point. |
| Maximum vibration | Specifications |
|---|---|
| Operating | 0.26 Grms at 5 Hz to 350 Hz (all operation orientations) |
| Storage | 1.88 Grms at 10 Hz to 500 Hz for 15 minutes (all six sides tested) |
| Maximum shock pulse | Specifications |
|---|---|
| Operating | Six consecutively executed shock pulses in the positive and negative x, y, and z axis of 6G for up to 11 ms. |
| Storage | Six consecutively executed shock pulses in the positive and negative x, y, and z axis (one pulse on each side of the system) of 71 G for up to 2 ms. |
| Maximum altitude | Specifications |
|---|---|
| Operating | 3048 m (10,000 ft) |
| Storage | 12,000 m (39,370 ft) |
| Operating temperature derating | Specifications |
|---|---|
| Up to 35°C (95°F) | Maximum temperature is reduced by 1°C/300 m (1°F/547 ft), above 900 m (2,953 ft). |
Thermal restriction matrix
| Ambient | 25°C | 30°C | 35°C |
|---|---|---|---|
| Processor | No restriction | No restriction | No restriction |
| DIMM | No restriction | No restriction | No restriction |
| Drive | Limited to entry drives with power less than 6.8W NOTE The PowerEdge T40 does not support enterprise-class drives. | ||
| Card | Limited to Tier 2 PCIe cards | ||
Particulate and gaseous contamination specifications
| Particulate contamination | Specifications |
|---|---|
| Air filtration | Data center air filtration as defined by ISO Class 8 per ISO 14644-1 with a 95% upper confidence limit. |
NOTE This condition
applies only to data center environments. Air filtration requirements
do not apply to IT equipment designed to be used outside a data center,
in environments such as an office or factory floor. |
|
NOTE Air entering
the data center must have MERV11 or MERV13 filtration. |
|
| Conductive dust | Air must be free of conductive dust, zinc whiskers, or other conductive particles. |
NOTE This condition
applies to data center and non-data center environments. |
|
| Corrosive dust | Air must be free of corrosive dust. |
| Residual dust present in the air must have a deliquescent point less than 60% relative humidity. | |
NOTE This condition
applies to data center and non-data center environments. |
|
| Gaseous contamination | Specifications |
|---|---|
| Copper coupon corrosion rate | <300 Å/month per Class G1 as defined by ANSI/ISA71.04-2013 |
| Silver coupon corrosion rate | <200 Å/month per Class G1 as defined by ANSI/ISA71.04-2013 |
NOTE Maximum corrosive
contaminant levels measured at ≤50% relative humidity. |
|