Dell EMC PowerEdge T150: технические характеристики и спецификации
Chassis dimensions
Figure 1. PowerEdgeT150 chassis dimensions
Table 1. Chassis dimension for the
PowerEdgeT150systemThis table provides the dimensions of the
PowerEdgeT150system:
Drives
Xa
Xb
Ya
Yb
Yc
Za
Zb
Zc
4 x 3.5-inch
175 mm (6.88 inches)
NA
360 mm (14.17 inches)
362.9 mm (14.28 inches)
NA
With bezel :
35 mm (17 inches)
Without bezel :
NA
400 mm (15.74 inches)
418.75 mm (16.48 inches)
NOTE:Zb is the nominal rear wall external surface where the system board I/O connectors reside.
System weight
Table 1. PowerEdgeT150 system weight The table below shows the maximum weight of the
PowerEdgeT150system.
System configuration
Maximum weight (with all drives/SSDs)
4 x 3.5-inch system
11.68 kg (25.74 lbs.)
Processor specifications
Table 1. PowerEdgeT150 processor specifications This table provides processor specifications for the system.
Supported processor
Number of processors supported
Intel Xeon E-2300 series processorwith up to 8 cores or Intel Pentium processor with up to 2 cores per processor
One
NOTE:Note: For Pentium processor, maximum memory speed supported is 2666 MT/s.
PSU specifications
The
PowerEdgeT150system supports one AC cabled power supply unit (PSU).
Table 1. PowerEdgeT150 PSU specificationsThe table lists the specifications for 300 W, and 400 W cabled power supplies.
PSU
Class
Heat dissipation (maximum)
Frequency
Voltage
AC
DC
Current
High line 200–240 V
Low line 100–120 V
300 W AC
Bronze
1024 BTU/hr
50/60 Hz
100–240 V AC, autoranging
300 W
300 W
NA
4.6 A
400 W AC
Platinum
1365 BTU/hr
50/60 Hz
100–240 V AC, autoranging
400 W
400 W
NA
5.4 A
NOTE:Heat dissipation is calculated using the PSU wattage rating.
NOTE:When selecting or upgrading the system configuration, to ensure optimum power utilization, verify the system power consumption with the Enterprise Infrastructure Planning Tool available at
Dell.com/calc.
Supported operating systems
The
PowerEdgeT150system supports the following operating systems:
Canonical Ubuntu Server LTS
VMware ESXi
Microsoft Windows Server with Hyper-V
SUSE Linux Enterprise Server
Red Hat Enterprise Linux
For more information, go to Operating System Manuals.
Cooling fans specifications
The
PowerEdgeT150system supports the following:
One system cooling fan located at the back of the system.
One processor cooling fan located on the heat sink.
NOTE: For more information about the fan support configuration or matrix, see
Thermal restriction matrix.
System battery specifications
The
PowerEdgeT150system supports
CR 2032 3.0-V lithium coin cell system battery.
Expansion card specifications
The
PowerEdgeT150system supports up to two PCI express (PCIe) Gen 4 and two PCIe Gen 3 expansion cards.
Table 1. Expansion card slots supported on the system boardThis table provides information about the expansion card slots that are supported on the system.
PCIe slot
Processor Connection
PCIe slot height
PCIe slot length
Slot width
Slot 1 (Gen4 from processor)
Processor
Full Height
Half Length
x4 link in x8 slot
Slot 2 (Gen4 from processor)
Processor
Full Height
Half Length
x16 link in x16 slot
Slot 3 (Gen3)
Platform Controller Hub
Full Height
Half Length
x1
Slot 4 (Gen3)
Platform Controller Hub
Full Height
Half Length
x4 link in x8 slot
NOTE:Slot 1 does not function when Pentium processor is installed.
NOTE: For information on the expansion card installation guidelines, see the system specific
Installation and Service Manual available on the
PowerEdge Manuals.
Memory specifications
The
PowerEdgeT150system supports the following memory specifications for optimized operation.
Table 1. Memory specificationsThe table below shows the memory specifications:
DIMM type
DIMM rank
DIMM capacity
Single processor
Minimum DIMM capacity
Maximum DIMM capacity
UDIMM
Single rank
8 GB
8 GB
32 GB
16 GB
16 GB
64 GB
Dual rank
32 GB
32 GB
128 GB
Table 2. Memory module socketsThe table below shows the memory module sockets for the system:
Memory module sockets
Speed
4, 288-pin
3200 MT/s, 2933 MT/s, 2666 MT/s
NOTE:32 GB x 4 supports 2933 MT/s.
NOTE:For Pentium processor, maximum memory speed supported is 2666 MT/s.
Storage controller specifications
The
PowerEdgeT150system supports the following controller cards:
Table 1. PowerEdgeT150 storage controller cardsThis table provides the controller cards supported on the system:
Internal controllers
External controllers
PERC H345
PERC H355
PERC H755
HBA355i
S150
HBA355e
Drives
The
PowerEdgeT150system supports
4 x 3.5-inch cabled
SAS/SATA (HDD/SSD) drives.
NOTE:PERC card is required when drive capacity is greater than or equal to 8 TB.
USB ports specifications
Table 1. PowerEdgeT150 USB ports specifications The following table shows the
PowerEdgeT150 USB ports specifications :
Front
Rear
Internal
USB port type
No. of ports
USB port type
No. of ports
USB port type
No. of ports
USB 3.0-compliant port
One
USB 2.0-compliant port
Five
Internal USB 3.0-compliant port
One
iDRAC Direct port (Micro-AB USB 2.0-compliant port)
One
USB 3.0-compliant port
One
NOTE:The micro-AB USB 2.0-compliant port can only be used as an iDRAC Direct or a management port.
NIC port specifications
The
PowerEdgeT150system supports up to two Onboard LOM 1GbE.
Serial connector specifications
The
PowerEdgeT150system supports one serial connector on rear of the system, which is a
9-pin connector,
Data Terminal Equipment (DTE),
16550-compliant
.
VGA ports specifications
The
PowerEdgeT150system supports one
DB-15 VGA port on the rear panel of the system.
Video specifications
The PowerEdge
T150 system supports integrated Matrox G200 graphics controller with 16 MB of video frame buffer.
Table 1. Supported video resolution options for the systemThis table lists the supported video display resolutions for the Dell
PowerEdge T150 server and shows the refresh rates and color depths available for
each resolution. The information is useful when connecting a monitor to the
server's video output.
Resolution
Refresh rate (Hz)
Color depth (bits)
1024 x 768
60, 72, 75, 85
8, 16, 32
1280 x 800
60, 75
8, 16, 32
1280 x 1024
60, 75, 85
8, 16, 32
1360 x 768
60
8, 16, 32
1440 x 900
60, 75, 85
8, 16, 32
1600 x 900
60
8, 16, 32
1600 x 1200
60, 65, 70, 75, 85
8, 16, 32
1680 x 1050
60, 75, 85
8, 16, 32
1920 x 1080
60
8, 16, 32
1920 x 1200
60, 75, 85
8, 16, 32
Environmental specifications
NOTE:For additional information about environmental certifications, refer to the
Product Environmental Datasheet located with the Documentation > Regulatory Information on
Dell Support.
Table 1. Operational climatic range category A2 This table describes the operational climatic range for category A2.
Temperature
Specifications
Allowable continuous operations
Temperature ranges for altitudes <= 900 m (<= 2953 ft)
10–35°C (50–95°F) with no direct sunlight on the equipment
Humidity percent ranges (non-condensing at all times)
8% RH with -12°C minimum dew point to 80% RH with 21°C (69.8°F) maximum dew point
Operational altitude de-rating
Maximum temperature is reduced by 1°C/300 m (1.8°F/984 Ft) above 900 m (2953 Ft)
Table 2. Operational climatic range category A4 This table describes the operational climatic range for category A4.
Temperature
Specifications
Allowable continuous operations
Temperature ranges for altitudes <= 900 m (<= 2953 ft)
5–45°C (41–113°F) with no direct sunlight on the equipment
Humidity percent ranges (non-condensing at all times)
8% RH with -12°C minimum dew point to 90% RH with 24°C (75.2°F) maximum dew point
Operational altitude de-rating
Maximum temperature is reduced by 1°C/125 m (33.8°F/410 Ft) above 900 m (2953 Ft)
Table 3. Shared requirements across all categories This table describes the shared requirements across all categories.
Temperature
Specifications
Allowable continuous operations
Maximum temperature gradient (applies to both operation and non-operation)
20°C in an hour* (36°F in an hour) and 5°C in 15 minutes (9°F in 15 minutes), 5°C in an hour* (9°F in an hour) for tape
NOTE:* - Per ASHRAE thermal guidelines for tape hardware, these are not instantaneous rates of temperature change.
Non-operational temperature limits
-40 to 65°C (-40 to 149°F)
Non-operational humidity limits
5% to 95% RH with 27°C (80.6°F) maximum dew point
Maximum non-operational altitude
12,000 meters (39,370 feet)
Maximum operational altitude
3,048 meters (10,000 feet)
Table 4. Maximum vibration specificationsThis table describes the Maximum vibration specifications
Maximum vibration
Specifications
Operating
0.21 Grms at 5 Hz to 500 Hz for 10 minutes (all x, y, and z axes)
Storage
1.88 G
rms at 10 Hz to 500 Hz for 15 minutes (all six sides tested)
Table 5. Maximum shock pulse specificationsThe maximum shock specification of an operational system is six consecutively executed shock pulses in the positive and negative x, y, and z axis of 6 G for up to 11 ms. The maximum shock specification of a nonoperational system is six consecutively executed shock pulses in the positive and negative x, y, and z axis (one pulse on each side of the system) of 71 G for up to 2 ms.
Maximum shock pulse
Specifications
Operating
Six consecutively executed shock pulses in the positive and negative x, y, and z axis of 6 G for up to 11 ms. Six consecutively executed shock pulses in the positive and negative x, y, and z axis of 6G for up to 11ms.
Storage
Six consecutively executed shock pulses in the positive and negative x, y, and z axis (one pulse on each side of the system) of 71 G for up to 2 ms
Particulate and gaseous contamination specifications
The following table defines the limitations that prevent the damage to the IT equipment and/or, or both failure from particulate and gaseous contamination. If the levels of particulate or gaseous pollution exceed the specified limitations and results in equipment damage or failure, you must rectify the environmental conditions. Remediation of environmental conditions is the responsibility of the customer.
Table 1. Particulate contamination specifications Air filtration specification: Data center air filtration as defined by ISO Class 8 per ISO 14644-1 should have a 95% upper confidence limit. This condition applies only to data center environments. Air filtration requirements do not apply to IT equipment designed to be used outside a data center, in environments such as an office or factory floor. Air entering the data center must have MERV11 or MERV13 filtration. Conductive dust specification: Air must be free of conductive dust, zinc whiskers, or other conductive particles. This condition applies to data center and non-data center environments. Corrosive dust specification: Air must be free of corrosive dust. Residual dust present in the air must have a deliquescent point less than 60% relative humidity. This condition applies to data center and non-data center environments.
Particulate contamination
Specifications
Air filtration
Data center air filtration as defined by ISO Class 8 per ISO 14644-1 with a 95% upper confidence limit.
NOTE:This condition applies to data center environments only. Air filtration requirements do not apply to IT equipment designed to be used outside a data center, in environments such as an office or factory floor.
NOTE:Air entering the data center must have MERV11 or MERV13 filtration.
Conductive dust
Air must be free of conductive dust, zinc whiskers, or other conductive particles.
NOTE:This condition applies to data center and non-data center environments.
Corrosive dust
Air must be free of corrosive dust.
Residual dust present in the air must have a deliquescent point less than 60% relative humidity.
NOTE:This condition applies to data center and non-data center environments.
Table 2. Gaseous contamination specifications The copper coupon corrosion rate is <300 Å/month per Class G1 as defined by ANSI/ISA71.04-2013. The silver coupon corrosion rate is <200 Å/month as defined by ANSI/ISA71.04-2013.
Gaseous contamination
Specifications
Copper Coupon Corrosion rate
<300 Å/month per Class G1 as defined by ANSI/ISA71.04-2013
Silver Coupon Corrosion rate
<200 Å/month as defined by ANSI/ISA71.04-2013
NOTE:Maximum corrosive contaminant levels measured at ≤50% relative humidity.
Thermal restrictions
Supported 3.5-inch drive count is restricted to 2 x drives per chassis for ASHRAE A4 requirement.