Dell EMC PowerEdge T150: технические характеристики и спецификации

Chassis dimensions

Figure 1. PowerEdgeT150 chassis dimensions
This image shows the chassis dimension.
Table 1. Chassis dimension for the PowerEdgeT150systemThis table provides the dimensions of the PowerEdgeT150system:
Drives Xa Xb Ya Yb Yc Za Zb Zc
4 x 3.5-inch175 mm (6.88 inches)NA360 mm (14.17 inches)362.9 mm (14.28 inches)NAWith bezel : 35 mm (17 inches)

Without bezel : NA

400 mm (15.74 inches)418.75 mm (16.48 inches)
NOTE:Zb is the nominal rear wall external surface where the system board I/O connectors reside.

System weight

Table 1. PowerEdge T150 system weight The table below shows the maximum weight of the PowerEdge T150 system.
System configuration Maximum weight (with all drives/SSDs)
4 x 3.5-inch system 11.68 kg (25.74 lbs.)

Processor specifications

Table 1. PowerEdge T150 processor specifications This table provides processor specifications for the system.
Supported processor Number of processors supported
Intel Xeon E-2300 series processor with up to 8 cores or Intel Pentium processor with up to 2 cores per processor One
NOTE:Note: For Pentium processor, maximum memory speed supported is 2666 MT/s.

PSU specifications

The PowerEdge T150 system supports one AC cabled power supply unit (PSU).

Table 1. PowerEdge T150 PSU specificationsThe table lists the specifications for 300 W, and 400 W cabled power supplies.
PSU Class Heat dissipation (maximum) Frequency Voltage AC DC Current
High line 200–240 V Low line 100–120 V
300 W AC Bronze 1024 BTU/hr 50/60 Hz 100–240 V AC, autoranging 300 W 300 W NA 4.6 A
400 W AC Platinum 1365 BTU/hr 50/60 Hz 100–240 V AC, autoranging 400 W 400 W NA 5.4 A
NOTE:Heat dissipation is calculated using the PSU wattage rating.
NOTE:When selecting or upgrading the system configuration, to ensure optimum power utilization, verify the system power consumption with the Enterprise Infrastructure Planning Tool available at Dell.com/calc.

Supported operating systems

The PowerEdge T150 system supports the following operating systems:

  • Canonical Ubuntu Server LTS
  • VMware ESXi
  • Microsoft Windows Server with Hyper-V
  • SUSE Linux Enterprise Server
  • Red Hat Enterprise Linux

For more information, go to Operating System Manuals.

Cooling fans specifications

The PowerEdge T150 system supports the following:

  • One system cooling fan located at the back of the system.
  • One processor cooling fan located on the heat sink.
NOTE: For more information about the fan support configuration or matrix, see Thermal restriction matrix.

System battery specifications

The PowerEdge T150 system supports CR 2032 3.0-V lithium coin cell system battery.

Expansion card specifications

The PowerEdge T150 system supports up to two PCI express (PCIe) Gen 4 and two PCIe Gen 3 expansion cards.
Table 1. Expansion card slots supported on the system boardThis table provides information about the expansion card slots that are supported on the system.
PCIe slot Processor Connection PCIe slot height PCIe slot length Slot width
Slot 1 (Gen4 from processor) Processor Full Height Half Length x4 link in x8 slot
Slot 2 (Gen4 from processor) Processor Full Height Half Length x16 link in x16 slot
Slot 3 (Gen3) Platform Controller Hub Full Height Half Length x1
Slot 4 (Gen3) Platform Controller Hub Full Height Half Length x4 link in x8 slot
NOTE:Slot 1 does not function when Pentium processor is installed.
NOTE: For information on the expansion card installation guidelines, see the system specific Installation and Service Manual available on the PowerEdge Manuals.

Memory specifications

The PowerEdge T150 system supports the following memory specifications for optimized operation.
Table 1. Memory specificationsThe table below shows the memory specifications:
DIMM type DIMM rank DIMM capacity Single processor
Minimum DIMM capacity Maximum DIMM capacity
UDIMM Single rank 8 GB 8 GB 32 GB
16 GB 16 GB 64 GB
Dual rank 32 GB 32 GB 128 GB
Table 2. Memory module socketsThe table below shows the memory module sockets for the system:
Memory module sockets Speed
4, 288-pin 3200 MT/s, 2933 MT/s, 2666 MT/s
NOTE:32 GB x 4 supports 2933 MT/s.
NOTE:For Pentium processor, maximum memory speed supported is 2666 MT/s.

Storage controller specifications

The PowerEdge T150 system supports the following controller cards:
Table 1. PowerEdge T150 storage controller cardsThis table provides the controller cards supported on the system:
Internal controllers External controllers
  • PERC H345
  • PERC H355
  • PERC H755
  • HBA355i
  • S150
  • HBA355e

Drives

The PowerEdge T150 system supports 4 x 3.5-inch cabled SAS/SATA (HDD/SSD) drives.
NOTE:PERC card is required when drive capacity is greater than or equal to 8 TB.

USB ports specifications

Table 1. PowerEdge T150 USB ports specifications The following table shows the PowerEdge T150 USB ports specifications :
Front Rear Internal
USB port type No. of ports USB port type No. of ports USB port type No. of ports
USB 3.0-compliant port One USB 2.0-compliant port Five Internal USB 3.0-compliant port One
iDRAC Direct port (Micro-AB USB 2.0-compliant port) One USB 3.0-compliant port One
NOTE:The micro-AB USB 2.0-compliant port can only be used as an iDRAC Direct or a management port.

NIC port specifications

The PowerEdge T150 system supports up to two Onboard LOM 1GbE.

Serial connector specifications

The PowerEdge T150 system supports one serial connector on rear of the system, which is a 9-pin connector, Data Terminal Equipment (DTE), 16550-compliant .

VGA ports specifications

The PowerEdge T150 system supports one DB-15 VGA port on the rear panel of the system.

Video specifications

The PowerEdge T150 system supports integrated Matrox G200 graphics controller with 16 MB of video frame buffer.

Table 1. Supported video resolution options for the systemThis table lists the supported video display resolutions for the Dell PowerEdge T150 server and shows the refresh rates and color depths available for each resolution. The information is useful when connecting a monitor to the server's video output.
Resolution Refresh rate (Hz) Color depth (bits)
1024 x 768 60, 72, 75, 85 8, 16, 32
1280 x 800 60, 75 8, 16, 32
1280 x 1024 60, 75, 85 8, 16, 32
1360 x 768 60 8, 16, 32
1440 x 900 60, 75, 85 8, 16, 32
1600 x 900 60 8, 16, 32
1600 x 1200 60, 65, 70, 75, 85 8, 16, 32
1680 x 1050 60, 75, 85 8, 16, 32
1920 x 1080 60 8, 16, 32
1920 x 1200 60, 75, 85 8, 16, 32

Environmental specifications

NOTE:For additional information about environmental certifications, refer to the Product Environmental Datasheet located with the Documentation > Regulatory Information on Dell Support.
Table 1. Operational climatic range category A2 This table describes the operational climatic range for category A2.
Temperature Specifications
Allowable continuous operations
Temperature ranges for altitudes <= 900 m (<= 2953 ft) 10–35°C (50–95°F) with no direct sunlight on the equipment
Humidity percent ranges (non-condensing at all times) 8% RH with -12°C minimum dew point to 80% RH with 21°C (69.8°F) maximum dew point
Operational altitude de-rating Maximum temperature is reduced by 1°C/300 m (1.8°F/984 Ft) above 900 m (2953 Ft)
Table 2. Operational climatic range category A4 This table describes the operational climatic range for category A4.
Temperature Specifications
Allowable continuous operations
Temperature ranges for altitudes <= 900 m (<= 2953 ft) 5–45°C (41–113°F) with no direct sunlight on the equipment
Humidity percent ranges (non-condensing at all times) 8% RH with -12°C minimum dew point to 90% RH with 24°C (75.2°F) maximum dew point
Operational altitude de-rating Maximum temperature is reduced by 1°C/125 m (33.8°F/410 Ft) above 900 m (2953 Ft)
Table 3. Shared requirements across all categories This table describes the shared requirements across all categories.
Temperature Specifications
Allowable continuous operations
Maximum temperature gradient (applies to both operation and non-operation) 20°C in an hour* (36°F in an hour) and 5°C in 15 minutes (9°F in 15 minutes), 5°C in an hour* (9°F in an hour) for tape
NOTE:* - Per ASHRAE thermal guidelines for tape hardware, these are not instantaneous rates of temperature change.
Non-operational temperature limits -40 to 65°C (-40 to 149°F)
Non-operational humidity limits 5% to 95% RH with 27°C (80.6°F) maximum dew point
Maximum non-operational altitude 12,000 meters (39,370 feet)
Maximum operational altitude 3,048 meters (10,000 feet)
Table 4. Maximum vibration specificationsThis table describes the Maximum vibration specifications
Maximum vibration Specifications
Operating 0.21 Grms at 5 Hz to 500 Hz for 10 minutes (all x, y, and z axes)
Storage 1.88 G rms at 10 Hz to 500 Hz for 15 minutes (all six sides tested)
Table 5. Maximum shock pulse specificationsThe maximum shock specification of an operational system is six consecutively executed shock pulses in the positive and negative x, y, and z axis of 6 G for up to 11 ms. The maximum shock specification of a nonoperational system is six consecutively executed shock pulses in the positive and negative x, y, and z axis (one pulse on each side of the system) of 71 G for up to 2 ms.
Maximum shock pulse Specifications
Operating Six consecutively executed shock pulses in the positive and negative x, y, and z axis of 6 G for up to 11 ms. Six consecutively executed shock pulses in the positive and negative x, y, and z axis of 6G for up to 11ms.
Storage Six consecutively executed shock pulses in the positive and negative x, y, and z axis (one pulse on each side of the system) of 71 G for up to 2 ms

Particulate and gaseous contamination specifications

The following table defines the limitations that prevent the damage to the IT equipment and/or, or both failure from particulate and gaseous contamination. If the levels of particulate or gaseous pollution exceed the specified limitations and results in equipment damage or failure, you must rectify the environmental conditions. Remediation of environmental conditions is the responsibility of the customer.
Table 1. Particulate contamination specifications Air filtration specification: Data center air filtration as defined by ISO Class 8 per ISO 14644-1 should have a 95% upper confidence limit. This condition applies only to data center environments. Air filtration requirements do not apply to IT equipment designed to be used outside a data center, in environments such as an office or factory floor. Air entering the data center must have MERV11 or MERV13 filtration. Conductive dust specification: Air must be free of conductive dust, zinc whiskers, or other conductive particles. This condition applies to data center and non-data center environments. Corrosive dust specification: Air must be free of corrosive dust. Residual dust present in the air must have a deliquescent point less than 60% relative humidity. This condition applies to data center and non-data center environments.
Particulate contamination Specifications
Air filtration Data center air filtration as defined by ISO Class 8 per ISO 14644-1 with a 95% upper confidence limit.
NOTE:This condition applies to data center environments only. Air filtration requirements do not apply to IT equipment designed to be used outside a data center, in environments such as an office or factory floor.
NOTE:Air entering the data center must have MERV11 or MERV13 filtration.
Conductive dust Air must be free of conductive dust, zinc whiskers, or other conductive particles.
NOTE:This condition applies to data center and non-data center environments.
Corrosive dust
  • Air must be free of corrosive dust.
  • Residual dust present in the air must have a deliquescent point less than 60% relative humidity.
NOTE:This condition applies to data center and non-data center environments.
Table 2. Gaseous contamination specifications The copper coupon corrosion rate is <300 Å/month per Class G1 as defined by ANSI/ISA71.04-2013. The silver coupon corrosion rate is <200 Å/month as defined by ANSI/ISA71.04-2013.
Gaseous contamination Specifications
Copper Coupon Corrosion rate <300 Å/month per Class G1 as defined by ANSI/ISA71.04-2013
Silver Coupon Corrosion rate <200 Å/month as defined by ANSI/ISA71.04-2013
NOTE:Maximum corrosive contaminant levels measured at ≤50% relative humidity.

Thermal restrictions

Supported 3.5-inch drive count is restricted to 2 x drives per chassis for ASHRAE A4 requirement.

NOTE:DIMM blank is not required.