Physical specifications
| Physical | Specifications |
|---|---|
| Height | 173.8 mm (6.84 inch) |
| Width (with rack latches) | 482.4 mm (18.99 inch) |
| Width (without rack latches) | 448.0 mm (17.64 inch) |
| Depth (excludes bezel) | 1098.4 mm (43.24 inch) |
| Total depth of system with cable management | 1242.68 mm (CMA) arm attached |
| Weight (Maximum) | 129.6 kg (285.72 lb) |
| Weight (empty) | 57.1 kg (125.88 lb) |
Processor specifications
| Processor | |
|---|---|
| Processor type | Intel Xeon EP E5-2600 v3 or v4 product family |
Expansion bus specifications
The system
supports PCI Express Generation 3 cards. For a list of supported expansion
cards, see the Expansion card installation guidelines section.
| Expansion slots using the expansion-card riser module | Specification |
|---|---|
| PCIE_G3_X8 | (Slot 1) One half-height, half-length x8 link for processor 2 |
| PCIE_G3_X16 | (Slot 2) One full-height, half-length x16 link for processor 1 |
| PCIE_G3_X8 | (Slot 3) One full-height, half-length x8 link for processor 1 |
| PCIE_G3_X8 | (Slot 4) One half-height, half-length x8 link for processor 1 |
Memory specifications
| Memory | Specifications |
|---|---|
| Architecture | 2133 MT/s DDR4 Registered DIMMs |
| Support for advanced Error Correcting Code (ECC) or memory optimized operation | |
| Memory module sockets | 12 288-pin |
| Memory module capacities (RDIMMs) | 16 GB dual-rank and 32 GB dual-rank |
| Minimum RAM | 192 GB with dual processor per node |
| Maximum RAM | Up to 384 GB with dual processor per node |
Power specifications
| Power | Specifications |
|---|---|
| AC power supply (per PSU) | |
| Wattage |
|
| Power rating per power supply unit |
|
| Heat dissipation NOTE: This system is also
designed to be connected to IT power systems with a phase to phase
voltage not exceeding 230 V. |
|
| Voltage | 200-240 V AC, autoranging, 50/60 Hz |
RAID Controller specifications
| Controller type | Specifications |
|---|---|
| RAID Controller |
|
Drives specifications
| Drives | Specifications |
|---|---|
| Hard Disk Drives (HDDs) | |
| Single-node systems with one server sled |
|
| Dual-node systems with two server sleds |
|
Connectors specifications (per server sled)
| Connectors (per server sled) | Specifications |
|---|---|
| Back | |
| NIC | Four 10/100/1000 Mbps |
| Serial | 9-pin, DTE, 16550-compatible |
| USB | One 9–pin, USB 3.0-compliant |
| One 4-pin, USB 2.0-compliant | |
| Video | 15-pin VGA |
| Internal | |
| USB | One 9–pin, USB 3.0-compliant |
Video specifications
| Video | Specifications |
|---|---|
| Video type | Integrated Matrox® G200 |
| Video memory | 16 MB shared |
Environmental specifications
NOTE: For additional information
about environmental measurements for specific system configurations,
see Dell.com/environmental_datasheets
| Temperature | |
| Storage | –40°C to 65°C (–40°F to 149°F) |
| Continuous operation (for altitude less than 950 m or 3117 ft) | 10°C to 35°C (50°F to 95°F) with no direct sunlight on the equipment. |
| Maximum temperature gradient (Operating and Storage) | 20°C/h (36°F/h) |
| Relative humidity (RH) | |
| Storage | 5% to 95% RH with 33°C (91°F) maximum dew point. Atmosphere must be non-condensing at all times. |
| Operating | 10 percent to 80 percent RH with 29°C (84.2°F) maximum dew point. |
| Maximum vibration | |
| Operating | 0.26 Grms at 5 Hz to 350 Hz (all operation orientations). |
| Storage | 1.88 Grms at 10 Hz to 500 Hz for 15 min (bottom side of shipment orientation only). |
| Maximum shock | |
| Operating | Four shock pulses per axis (the positive and negative
x, y, and z axes), 24 total shock pulses. 40 G, 2.3 ms for x and y axes. 36 G, 2.3 ms for z axe. |
| Storage |
|
| Maximum altitude | |
| Operating | 3048 m (10,000 ft). |
| Storage | 12,000 m (39,370 ft). |
| Operating temperature de-rating | |
| Up to 35°C (95°F) | Maximum temperature is reduced by 1°C/300 m (1°F/547 ft) above 950 m (3,117 ft). |
| 35°C to 40°C (95°F to 104°F) | Maximum temperature is reduced by 1°C/175 m (1°F/319 ft) above 950 m (3,117 ft). |
| 40°C to 45°C (104°F to 113°F) | Maximum temperature is reduced by 1°C/125 m (1°F/228 ft) above 950 m (3,117 ft). |
Particulate contamination
NOTE: This section defines
the limits to help avoid IT equipment damage and/or failure from particulates
and gaseous contamination. If it is determined that levels of particulates
or gaseous pollution are beyond the limits specified below and are
the reason for the damage and/or failures to your equipment, it may
be necessary for you to re-mediate the environmental conditions that
are causing the damage and/or failures. Re-mediation of environmental
conditions will be the responsibility of a customer
| Air Filtration NOTE: Applies to data center
environments only. Air filtration requirements do not apply to IT
equipment designed to be used outside a data center, in environments
such as an office or factory floor. |
Data center air filtration as defined by ISO Class
8 per ISO 14644-1 with a 95 percent upper confidence limit. NOTE: Air entering the datacenter
must have MERV11 or MERV13 filtration. |
| Conductive dust NOTE: Applies to data center
and non-data center environments. |
Air must be free of conductive dust, zinc whiskers, or other conductive particles. |
| Corrosive Dust NOTE: Applies to data center
and non-data center environments. |
|
| Gaseous contamination NOTE: Maximum
corrosive contaminant levels measured at ≤50 percent relative humidity.
|
|
| Copper coupon corrosion rate | <300 Å/month per Class G1 as defined by ANSI/ISA71.04-1985 |
| Silver coupon corrosion rate | <200 Å/month as defined by AHSRAE TC9.9. |
Expanded Operating Temperature
| NOTE: When operating in the
expanded temperature range, system performance may be impacted.
NOTE: When operating in the expanded temperature range, ambient temperature
warnings may be reported on the LCD and in the System Event Log.
|
|
| < 10 percent of annual operating hours | 5°C to 40°C at 5 percent to 85 percent RH with
26°C dew point. NOTE: Outside the standard
operating temperature (10°C to 35°C), the system can operate down
to 5°C or up to 40°C for a maximum of 10 percent of its annual operating
hours. For temperatures between 35°C and 40°C, de-rate maximum allowable dry bulb temperature by 1°C per 175 m above 950 m (1°F per 319 ft). |
| < 1 percent of annual operating hours | –5°C to 45°C at 5 percent to 90 percent (RH) with
26°C dew point. NOTE: Outside the standard
operating temperature (10°C to 35°C), the system can operate down
to –5°C or up to 45°C for a maximum of 1 percent of its annual operating
hours. For temperatures between 40°C and 45°C, de-rate maximum allowable dry bulb temperature by 1°C per 125 m above 950 m (1°F per 319 ft). |
| Expanded operating temperature restrictions |
|