Dell SD7000-S — Storage Designed for Scality RING: руководство по обслуживанию

Physical specifications

Table 1. The Dell SD7000-S system supports the following physical specificationsPhysical specifications
Physical Specifications
Height 173.8 mm (6.84 inch)
Width (with rack latches) 482.4 mm (18.99 inch)
Width (without rack latches) 448.0 mm (17.64 inch)
Depth (excludes bezel) 1098.4 mm (43.24 inch)
Total depth of system with cable management1242.68 mm (CMA) arm attached
Weight (Maximum) 129.6 kg (285.72 lb)
Weight (empty) 57.1 kg (125.88 lb)

Processor specifications

Table 1. The Dell SD7000-S system supports the following processor specificationsProcessor specifications
Processor
Processor type Intel Xeon EP E5-2600 v3 or v4 product family

Expansion bus specifications

The system supports PCI Express Generation 3 cards. For a list of supported expansion cards, see the Expansion card installation guidelines section.
Table 1. The Dell SD7000-S system supports the following expansion bus specificationsexpansion bus specifications
Expansion slots using the expansion-card riser module Specification
PCIE_G3_X8 (Slot 1) One half-height, half-length x8 link for processor 2
PCIE_G3_X16 (Slot 2) One full-height, half-length x16 link for processor 1
PCIE_G3_X8 (Slot 3) One full-height, half-length x8 link for processor 1
PCIE_G3_X8 (Slot 4) One half-height, half-length x8 link for processor 1

Memory specifications

Table 1. The Dell SD7000-S system supports the following memory specificationsmemory specifications
Memory Specifications
Architecture 2133 MT/s DDR4 Registered DIMMs
Support for advanced Error Correcting Code (ECC) or memory optimized operation
Memory module sockets 12 288-pin
Memory module capacities (RDIMMs) 16 GB dual-rank and 32 GB dual-rank
Minimum RAM 192 GB with dual processor per node
Maximum RAM Up to 384 GB with dual processor per node

Power specifications

Table 1. The Dell SD7000-S system supports the following power specificationspower specifications
Power Specifications
AC power supply (per PSU)
Wattage
  • 1100 W PSUs for support on Dual Nodes only
  • 1600 W PSUs for support on Single Nodes only
Power rating per power supply unit
  • 1100 W (Platinum) AC (200–240 V, 50/60 Hz, 6.5 A)
  • 1600 W (Gold) AC (200 – 240 V, 50/60 Hz, 10.0 A)
Heat dissipation
NOTE: This system is also designed to be connected to IT power systems with a phase to phase voltage not exceeding 230 V.
  • 4170 BTU/hr maximum (1100 W PSU) or
  • 6060 BTU/hr maximum (1600W PSU)
Voltage 200-240 V AC, autoranging, 50/60 Hz

RAID Controller specifications

Table 1. The Dell SD7000-S system supports the following RAID controller specificationsRAID controller specifications
Controller type Specifications
RAID Controller
  • LSI 9361-8i

Drives specifications

Table 1. The Dell SD7000-S system supports the following drive specificationsdrive specifications
Drives Specifications
Hard Disk Drives (HDDs)
Single-node systems with one server sled
  • Up to 90 3.5-inch hot-swappable Serial Attached SCSI (SAS) HDDs, SATA HDDs, or SATA SSDs or
  • Up to 16 hot-swappable SATA or SAS SSDs
Dual-node systems with two server sleds
  • Up to 90 3.5-inch hot-swappable Serial Attached SCSI (SAS) HDDs, SATA HDDs, or SATA SSDs or
  • Up to 12 hot-swappable SATA or SAS SSDs

Connectors specifications (per server sled)

Table 1. The Dell SD7000-S system supports the following controller specificationscontroller specifications (per server sled)
Connectors (per server sled) Specifications
Back
NIC Four 10/100/1000 Mbps
Serial 9-pin, DTE, 16550-compatible
USB One 9–pin, USB 3.0-compliant
One 4-pin, USB 2.0-compliant
Video 15-pin VGA
Internal
USB One 9–pin, USB 3.0-compliant

Video specifications

Table 1. The Dell SD7000-S system supports the following video specificationsvideo specifications
Video Specifications
Video type Integrated Matrox® G200
Video memory 16 MB shared

Environmental specifications

NOTE: For additional information about environmental measurements for specific system configurations, see Dell.com/environmental_datasheets
Table 1. The Dell SD7000-S system supports the following environmental specificationsenvironmental specifications
Temperature
Storage –40°C to 65°C (–40°F to 149°F)
Continuous operation (for altitude less than 950 m or 3117 ft) 10°C to 35°C (50°F to 95°F) with no direct sunlight on the equipment.
Maximum temperature gradient (Operating and Storage) 20°C/h (36°F/h)
Relative humidity (RH)
Storage 5% to 95% RH with 33°C (91°F) maximum dew point. Atmosphere must be non-condensing at all times.
Operating 10 percent to 80 percent RH with 29°C (84.2°F) maximum dew point.
Maximum vibration
Operating 0.26 Grms at 5 Hz to 350 Hz (all operation orientations).
Storage 1.88 Grms at 10 Hz to 500 Hz for 15 min (bottom side of shipment orientation only).
Maximum shock
Operating Four shock pulses per axis (the positive and negative x, y, and z axes), 24 total shock pulses.

40 G, 2.3 ms for x and y axes.

36 G, 2.3 ms for z axe.

Storage
  • 71 G, 2 ms pulse shape is Half-Sine (bottom side of shipping orientation only).
  • 15 G, 165 in/sec pulse shape is Square-Wave (bottom side of shipping orientation only)
Maximum altitude
Operating 3048 m (10,000 ft).
Storage 12,000 m (39,370 ft).
Operating temperature de-rating
Up to 35°C (95°F) Maximum temperature is reduced by 1°C/300 m (1°F/547 ft) above 950 m (3,117 ft).
35°C to 40°C (95°F to 104°F) Maximum temperature is reduced by 1°C/175 m (1°F/319 ft) above 950 m (3,117 ft).
40°C to 45°C (104°F to 113°F) Maximum temperature is reduced by 1°C/125 m (1°F/228 ft) above 950 m (3,117 ft).

Particulate contamination

NOTE: This section defines the limits to help avoid IT equipment damage and/or failure from particulates and gaseous contamination. If it is determined that levels of particulates or gaseous pollution are beyond the limits specified below and are the reason for the damage and/or failures to your equipment, it may be necessary for you to re-mediate the environmental conditions that are causing the damage and/or failures. Re-mediation of environmental conditions will be the responsibility of a customer
Table 1. The Dell SD7000-S system supports the following particulate contamination specificationsparticulate contamination specifications
Air Filtration
NOTE: Applies to data center environments only. Air filtration requirements do not apply to IT equipment designed to be used outside a data center, in environments such as an office or factory floor.
Data center air filtration as defined by ISO Class 8 per ISO 14644-1 with a 95 percent upper confidence limit.
NOTE: Air entering the datacenter must have MERV11 or MERV13 filtration.
Conductive dust
NOTE: Applies to data center and non-data center environments.
Air must be free of conductive dust, zinc whiskers, or other conductive particles.
Corrosive Dust
NOTE: Applies to data center and non-data center environments.
  • Air must be free of corrosive dust.
  • Residual dust present in the air must have a deliquescent point less than 60 percent relative humidity.
Gaseous contamination
NOTE: Maximum corrosive contaminant levels measured at ≤50 percent relative humidity.
Copper coupon corrosion rate <300 Å/month per Class G1 as defined by ANSI/ISA71.04-1985
Silver coupon corrosion rate <200 Å/month as defined by AHSRAE TC9.9.

Expanded Operating Temperature

Table 1. The Dell SD7000-S system supports the following expanded operating temperature specificationsexpanded operating temperature specifications
NOTE: When operating in the expanded temperature range, system performance may be impacted.
NOTE: When operating in the expanded temperature range, ambient temperature warnings may be reported on the LCD and in the System Event Log.
< 10 percent of annual operating hours 5°C to 40°C at 5 percent to 85 percent RH with 26°C dew point.
NOTE: Outside the standard operating temperature (10°C to 35°C), the system can operate down to 5°C or up to 40°C for a maximum of 10 percent of its annual operating hours.

For temperatures between 35°C and 40°C, de-rate maximum allowable dry bulb temperature by 1°C per 175 m above 950 m (1°F per 319 ft).

< 1 percent of annual operating hours –5°C to 45°C at 5 percent to 90 percent (RH) with 26°C dew point.
NOTE: Outside the standard operating temperature (10°C to 35°C), the system can operate down to –5°C or up to 45°C for a maximum of 1 percent of its annual operating hours.

For temperatures between 40°C and 45°C, de-rate maximum allowable dry bulb temperature by 1°C per 125 m above 950 m (1°F per 319 ft).

Expanded operating temperature restrictions
  • Processors of 55 W and 65 W are not supported.
  • Do not perform a cold startup at less than 5°C.
  • Allow processor performance degrade.
  • Non-redundant PSUs are not supported.
  • Non-Dell qualified peripheral cards and/or peripheral cards are not supported.
  • Maximum altitude for the operating temperature must be 3050 m (10,000 ft).