Сегодня покупают
← Вернуться назад
Нужна помощь с конфигурацией?
Пришлите SKU, спецификацию или список требований. Специалист Apltech проверит совместимость компонентов и найдёт актуальные артикулы
Получить консультацию →

Dell SCv2080 Storage System: руководство по обслуживанию

Technical Specifications

The technical specifications for the SCv2080 storage system are shown in the following tables.

Table 1. Drive SpecificationsSpecifications for the SC7020 and SC7020F drives
Drives
SAS hard drives Up to 84 3.5-inch SAS hot-swappable hard drives (6.0 Gbps)
Table 2. Storage Controller SpecificationsSpecifications for the storage controllers
Storage Controllers
Storage controllers Two hot-swappable storage controllers with the following IO options:
  • Two 16 Gbps Fibre Channel ports
  • Four 8 Gbps Fibre Channel ports
  • Two 10 Gbps iSCSI ports
  • Four 1 Gbps iSCSI ports
  • Four 12 Gbps SAS ports
Table 3. Storage Connectivity ConfigurationsSpecifications for the storage connectivity configurations
Storage Connectivity
Configurations Storage Center supports up to 168 drives on a single supports up to 168 drives on a single redundant-path SAS chain.

The SCv2080 storage system supports one SC180.

Table 4. RAID SpecificationsSpecifications for the RAID controllers and management
Redundant Array of Independent Disks (RAID)
Controller Two hot-swappable storage controllers
Management RAID management using Dell Storage Manager Client
Table 5. Back-Panel Port SpecificationsSpecifications for the back-panel port connectors
Back-Panel Ports Connectors (per Storage Controller)
Fibre Channel, iSCSI, or SAS connectors Connection to a Fibre Channel fabric, a iSCSI network, or a direct connection to servers with SAS HBAs
Ethernet connectors MGMT: 1 Gbps or 10 Gbps embedded Ethernet/iSCSI port that is typically used for Storage Center management

REPL: 1 Gbps or 10 Gbps embedded iSCSI port that is typically used for replication to another Storage Center

SAS connectors 6 Gbps SAS connectors for SAS port redundancy and an additional expansion enclosure
NOTE:SAS connectors are SFF-8086/SFF-8088 compliant.
USB Connector One USB 3.0 connector used for Storage Center updates
Serial connector
NOTE:Not for customer use.
Table 6. LED Indicator SpecificationsSpecifications for the LED indicators
LED Indicators
Front panel
  • One two-digit LCD indicator for Unit ID, error code, and unit location identifier
  • One two-color LED indicator for power status
  • One single-color LED indicator for module fault status (enclosure as a whole)
  • One single-color LED indicator for logical fault status (drive, HBA, RAID controller, and so on)
  • One single-color LED indicator for drawer 1 fault status
  • One single-color LED indicator for drawer 2 fault status
Drawer
  • One single-color LED indicator for sideplane card and power status
  • One single-color LED indicator for drawer fault status
  • One single-color LED indicator for logical fault status
  • One single-color LED indicator for cable fault status
  • Six single-color LED indicators for data transfer status
Disk Drive In Carrier (DDIC) One single-color LED for drive fault status
6 Gb SAS IO module 14 one-color LED status indicators, four each for the three SAS ports and two for the module status
Cooling module
  • One single-color LED indicator for module status
  • One single-color LED indicator for battery fault status (not currently used)
  • One single-color LED indicator for fan fault status
Power supply unit (PSU)
  • One single-color LED indicator for PSU fault status
  • One single-color LED indicator for AC power fault status
  • One single-color LED indicator for power status
Table 7. Power Supply SpecificationsSpecifications for the power supply units
Power Supplies
AC power supply (per power supply)
Wattage 2.8 kW
Voltage 200–240 VAC (16 A)
Heat dissipation 191-147 W
Input frequency 50/60 Hz
Max input power 1791 VA
Input current 7.4 A@241 VAC
Maximum inrush current Under typical line conditions and over the entire system ambient operating range, the inrush current may reach 55 A per power supply for 10 ms or less
Table 8. Hard Drive Power SpecificationsSpecifications for the available hard drive power per slot
Available Hard Drive Power (per Slot)
Supported hard drive power consumption (continuous) Up to 1.16 A at +5 V

Up to 1.6 A at +12 V

Table 9. I/O Card Power SpecificationsSpecifications for the available I/O card power per slot
I/O Card Power (per Slot)
Maximum power consumed by I/O card 11 W at +12 V
Maximum available power 100 W at +12 V
Minimum available power 1 W at +5 V (standby)
Table 10. Physical SpecificationsSpecifications of the physical dimensions and weight
Physical
Height 22.23 cm (8.8 inches)
Width 48.26 cm (19 inches)
Depth (front mounting bracket to rear surface) 91.44 cm (36 inches)
Depth (front surface to rear surface) 96 cm (38 inches)
Weight (maximum configuration) 130.1 kg (287 lb)
Weight without drives 62.1 kg (137 lb)
Table 11. Environmental SpecificationsSpecifications of the environmental measurements
Environmental
Temperature
Operating 10°C to 35°C (50°F to 95°F) with a maximum temperature gradation of 20°C per hour
NOTE:The storage controller midplane temperature sensors are offset by approximately 3°C (5°F), resulting in an actual minimum operating temperature of 13°C (55°F).
NOTE:Maximum temperature of 35°C is reduced by 1°C per 300 meter (1°F per 547 feet) above 950 meters (3,117 feet)
Storage –40°C to 65°C (–40°F to 149°F) at a maximum altitude of 12,000 m (39,370 ft)
Relative humidity
Operating 10% to 80% (noncondensing) with 29°C (84.2°F) maximum dew point
Storage 5% to 95% (noncondensing) with 33°C (91°F) maximum dew point
Maximum vibration
Operating 0.21 G at 5–500 Hz for 15 min
Storage 1.04 G at 2–200 Hz for 15 min
Maximum shock
Operating Half-sine shock 5 G +/- 5% with a pulse duration of 10 ms +/- 10% (in operational orientations only)
Storage
  • Z-axis: 30 g 10 ms half sine
  • X- and Y-axes: 20 g 10 ms half sine
Altitude
Operating 0 m to 3048 m (0 ft to 10,000 ft)
Storage –300 m to 12,000 m (–1000 ft to 39,370 ft)
Airborne Contaminant Level
Class G2 or lower as defined by ISA-S71.04-1985