Technical Specifications
| Processor | ||
|---|---|---|
| Processor type | Two or Four Intel Xeon Processor E7-8800/4800/2800 v2 product family | |
| Power | ||
|---|---|---|
| AC Power Supply (per power supply) | ||
| Wattage | 750 W, 1100 W, or 1600 W (when available)
NOTE:Your system supports a maximum of two 1600 W power supplies.
|
|
| Heat dissipation
NOTE:Heat dissipation is calculated using the power supply wattage rating.
|
2891 BTU/hr maximum (750 W power supply) 2780 BTU/hr maximum (750 W Titanium power supply) 4100 BTU/hr maximum (1100 W power supply) |
|
| Voltage
NOTE:This system is also designed to be connected to IT power systems with a phase to phase voltage not exceeding 230 V.
|
100–240 V AC, autoranging, 50/60 Hz
or 200–240 V AC, autoranging, 50/60 Hz, for 750 W Titanium power supply |
|
| DC Power Supply (per power supply) | ||
| Wattage | 1100 W | |
| Heat dissipation
NOTE:Heat dissipation is calculated using the power supply wattage rating.
|
4416 BTU/hr maximum | |
| Voltage | –(48–60) V DC | |
| Battery | ||
| Coin-cell battery | 3 V CR2032 Lithium coin cell | |
| Expansion Bus | |||
|---|---|---|---|
| Bus type | PCI Express Generation 3 | ||
| Expansion slots using riser card: | |||
| Riser 1 (NDC riser default) | (Slot 2) One full-height, half-length x8 link | ||
| Riser 2 (optional) | (Slot 1/1) One full-height, full-length x4 link | ||
| (Slot 2/2) One full-height, half-length x4 link | |||
| (Slot 3) One full-height, half-length x8 link | |||
| (Slot 4) One full-height, full-length x16 link | |||
|
NOTE:To use slots 6 through 10, all four processors must be installed.
|
|||
| (Slot 5) One full-height, half-length x16 link | |||
| (Slot 6) One full-height, half-length x16 link | |||
| (Slot 7) One full-height, half-length x16 link | |||
| (Slot 8) One full-height, half-length x16 link | |||
| Riser 3 (optional) | (Slot 1/ 9) One full-height, full-length x8 link | ||
| (Slot 2/ 10) One full-height, half-length x8 link | |||
| Memory | ||
|---|---|---|
| Architecture | 1066 MT/s, 1333 MT/s or 1600 MT/s DDR3 registered, load-reduced Error Correcting Code (ECC) DIMMs | |
| Support for advanced ECC or memory optimized operation | ||
| Memory module sockets | Ninety-six 240-pin | |
| Memory module capacities | ||
| LRDIMMs | 32 GB quad-ranked | |
| RDIMMs | 4 GB, 8 GB, or 32 GB single-, dual-, quad-, or octal-ranked | |
| Minimum RAM | 4 GB with a single processor | |
| Maximum RAM | ||
| LRDIMMs and RDIMMs | Up to 6 TB | |
| Drives | ||
|---|---|---|
| Hard drives | ||
| Four hard-drive systems | Up to four 2.5 inch, internal, hot-swappable SAS hard drives in hard-drive slots 0 through 3.
This configuration supports:
|
|
| Twenty four hard-drive systems (SAS/SATA) | Up to twenty four 2.5 inch, internal, hot-swappable SAS/SATA hard-drives.
This configuration supports:
NOTE:With single
Unified mode daughter card and PERC 9 card the hard-drives are located in hard-drive slots 0 through 24 (bay 1).
NOTE:With two
Performance mode daughter cards and two PERC 9 cards the hard-drives are located in hard-drive slots 0 through 11(bay 1) and 0 through 11(bay 2)
|
|
| Twenty four or sixteen plus eight hard-drive systems | Up to sixteen 2.5 inch, internal, hot-swappable SAS drives and up to eight Dell PowerEdge Express Flash devices (PCIe SSDs) hard drives in hard-drive slots 0 through 4 (bay 1), 0 through 4 (bay 2), and 0 through 15 (bay 3) for SAS/SATA with 2 PCIe Extender Cards, one Unified Mode Daughter Card, and one PERC 9 Card.
NOTE:Performance mode daughter cards (hard-drive slots 0 through 7 on SAS/SATA) are not supported.
|
|
| Twenty four hard-drive systems (SAS-3 (12Gb/s))
Performance Mode (split-capable) |
Up to twenty four 2.5 inch, internal, hot-swappable SAS hard drives.
NOTE:When the backplane is NOT in the split mode with single internal PERC, the maximum number of SATA/SSDs are 12 in the right bay (hard drives slots 12 through 23).
|
|
| Twenty four or sixteen plus eight hard-drive systems (SATA SSD) | Up to sixteen 2.5 inch, internal, hot-swappable SATA drives and up to eight Dell PowerEdge Express Flash devices (PCIe SSDs) hard drives in hard-drive slots 0 through 4 (bay 1), 0 through 4 (bay 2), and 8 through 15 (bay 3) for SAS/SATA. | |
| Optical drive | One optional SATA DVD-ROM drive or DVD+/-RW drive. | |
| Connectors | ||
|---|---|---|
| Back | ||
| NIC | Four RJ-45 10/100/1000 Mbps Ethernet | |
| Serial | 9-pin, DTE, 16550-compatible | |
| USB | Two 4-pin, USB 2.0-compliant | |
| Video | 15-pin VGA | |
| iDRAC7 | One RJ-45 10/100/1000 Mbps Ethernet | |
| Front | ||
| USB | Two 4-pin, USB 2.0-compliant | |
| Video | 15-pin VGA | |
| External vFlash card | vFlash memory card slot
NOTE:The card slot is available for use only if the iDRAC7 Enterprise license is installed on your system.
|
|
| Internal | ||
| USB | One 4-pin, USB 2.0-compliant | |
| Internal Dual SD Module | Two optional flash memory card slots with the internal SD module
NOTE:One card slot is dedicated for redundancy.
|
|
| Video | ||
|---|---|---|
| Video type | Integrated Matrox G200 with iDRAC7 | |
| Video memory | 16 MB shared with iDRAC7 application memory | |
| Expanded Operating Temperature | ||
|---|---|---|
|
NOTE:When operating in the expanded temperature range, system performance may be impacted.
NOTE:When operating in the expanded temperature range, ambient temperature warnings may be reported on the LCD and in the System Event Log.
|
||
| < 10% of annual operating hours | 5 °C to 40 °C at 5% to 85% RH with 26 °C dew point.
NOTE:Outside the standard operating temperature (10 °C to 35 °C), the system can operate down to 5 °C or up to 40 °C for a maximum of 10% of its annual operating hours.
For temperatures between 35 °C and 40 °C, de-rate maximum allowable dry bulb temperature by 1 °C per 175 m above 950 m (1 °F per 319 ft). |
|
| < 1% of annual operating hours | –5 °C to 45 °C at 5% to 90% RH with 26 °C dew point.
NOTE:Outside the standard operating temperature (10 °C to 35 °C), the system can operate down to –5 °C or up to 45 °C for a maximum of 1% of its annual operating hours.
For temperatures between 40 °C and 45 °C, de-rate maximum allowable dry bulb temperature by 1 °C per 125 m above 950 m (1 °F per 228 ft). |
|
| Expanded Operating Temperature Restrictions |
|
|
|
NOTE:Your system is capable of 40 °C and 45 °C excursion operation for fresh air cooled data centers.
NOTE:For additional information about environmental measurements for specific system configurations, see
dell.com/environmental_datasheets.
|
||
| Temperature | ||
| Maximum Temperature Gradient (Operating and Storage) | 20 °C/h (36 °F/h) | |
| Storage Temperature Limits | –40 °C to 65 °C (–40 °F to 149 °F) | |
| Temperature (Continuous Operation) | ||
| Temperature Ranges (for altitude less than 950 m or 3117 ft) | 10 °C to 35 °C (50 °F to 95 °F) with no direct sunlight on the equipment. | |
| Humidity Percentage Range | 10% to 80% Relative Humidity with 26 °C (78.8 °F) maximum dew point. | |
| Relative Humidity | ||
| Storage | 5% to 95% RH with 33 °C (91 °F) maximum dew point. Atmosphere must be non-condensing at all times. | |
| Maximum Vibration | ||
| Operating | 0.26 Grms at 5 Hz to 350 Hz (all operation orientations). | |
| Storage | 1.87 Grms at 10 Hz to 500 Hz for 15 min (all six sides tested). | |
| Maximum Shock | ||
| Operating | One shock pulse in the positive z axis of 40 G for 2.3 ms in all operational orientations. | |
| Storage | Six consecutively executed shock pulses in the positive and negative x, y, and z axes (one pulse on each side of the system) of 71 G for up to 2 ms. | |
| Maximum Altitude | ||
| Operating |
3048 m (10,000 ft). |
|
| Storage | 12,000 m (39,370 ft). | |
| Operating Altitude De-rating | ||
| Up to 35 °C (95 °F) | Maximum temperature is reduced by 1 °C/300 m (1 °F/547 ft) above 950 m (3,117 ft). | |
| 35 °C to 40 °C (95 °F to 104 °F) | Maximum temperature is reduced by 1 °C/175 m (1 °F/319 ft) above 950 m (3,117 ft). | |
| 40 °C to 45 °C (104 °F to 113 °F) | Maximum temperature is reduced by 1 °C/125 m (1 °F/228 ft) above 950 m (3,117 ft). | |
| Particulate Contamination
NOTE:This section defines the limits to help avoid IT equipment damage and/or failure from particulates and gaseous contamination. If it is determined that levels of particulates or gaseous pollution are beyond the limits specified below and are the reason for the damage and/or failures to your equipment, it may be necessary for you to re-mediate the environmental conditions that are causing the damage and/or failures. Re-mediation of environmental conditions will be the responsibility of the customer.
|
||
| Air Filtration
NOTE:Applies to data center environments only. Air filtration requirements do not apply to IT equipment designed to be used outside a data center, in environments such as an office or factory floor.
|
Data center air filtration as defined by ISO Class 8 per ISO 14644-1 with a 95% upper confidence limit.
NOTE:Air entering the data center must have MERV11 or MERV13 filtration.
|
|
| Conductive Dust
NOTE:Applies to data center and non-data center environments.
|
Air must be free of conductive dust, zinc whiskers, or other conductive particles. | |
| Corrosive Dust
NOTE:Applies to data center and non-data center environments.
|
|
|
| Gaseous Contamination | ||
|
NOTE:Maximum corrosive contaminant levels measured at ≤50% relative humidity.
|
||
| Copper Coupon Corrosion Rate | <300 Å/month per Class G1 as defined by ANSI/ISA71.04-1985. | |
| Silver Coupon Corrosion Rate | <200 Å/month as defined by AHSRAE TC9.9. | |