Dell PowerEdge R7715: руководство по обслуживанию

Chassis dimensions

Figure 1. Chassis dimensions
This image shows chassis dimension for the PowerEge R7715 system.
Table 1. PowerEdgeR7715 chassis dimensionsThis table provides the dimensions of the system:
Drives Xa Xb Y Za Zb Zc
All drive configurations 482.0 mm (18.97 inches)434.0 mm (17.08 inches)86.8 mm (3.41 inches)30.78 mm (1.21 inches)With bezel

29.89mm (1.18 inches)Without bezel

700.7 mm (27.58 inches)Ear to rear wall771.62 mm (30.38 inches)Ear to PSU handle
NOTE:Zb is the nominal rear wall external surface where the HPM board I/O connectors reside.

System weight

Table 1. PowerEdge R7715 system weightThe table below shows the maximum weight of the system.
System configuration Maximum weight (with all drives/SSDs)
No backplane configuration 22.93 kg (50.55 lb)
2 x U.2 SSD 20.24 kg (44.62 lb)
8 x 2.5-inch Universal drives 26.26 kg (57.89 lb)
8 x EDSFF E3.S Gen5 NVMe drives 27.33 kg (60.25 lb)
12 x 3.5-inch SAS/SATA drives 26.85 kg (59.19 lb)
16 x 2.5-inch SAS/SATA + 8 x U.2 drives 26.58 kg (58.59 lb)
16 x 2.5-inch SAS/SATA drives 26.81 kg (59.10 lb)
16 x EDSFF E3.S Gen5 NVMe drives 28.68 kg (63.22 lb)
24 x 2.5-inch SAS/SATA drives 27.67 kg (61.00 lb)
32 x EDSFF E3.S Gen5 NVMe drives 26.68 kg (58.81 lb)
40 x EDSFF E3.S Gen5 NVMe drives 28.38 kg (62.56 lb)
Table 2. PowerEdge R7715 weight handling recommendationsThis table shows the recommendations in handling the system weight.
Chassis weight Description
40–70 lb Recommend two people to lift.
70–120 lb Recommend three people to lift.
≥ 121 lb Recommend to use a server-lift.

Memory specifications

The PowerEdge R7715 system supports the following memory specifications for optimized operation.
Table 1. Memory specificationsThe table below shows the memory specifications:
DIMM type DIMM rank DIMM capacity Dual processor
Minimum system capacity Maximum system capacity
RDIMM Single rank 16 GB 16 GB 384 GB
Dual rank 32 GB 32 GB 768 GB
64 GB 64 GB 1.5 TB
96 GB 96 GB 2.3 TB
128 GB 128 GB 3 TB
Eight rank 256 GB 256 GB 6 TB
Table 2. Memory module socketsThe table below shows the memory module sockets for the system:
Memory module sockets Speed
24 DDR5 DIMM slots 5200 MT/s, 4000 MT/s
NOTE:Memory DIMM slots are not hot pluggable.
NOTE:The processor may reduce the performance of the rated DIMM speed.

Cooling fan specifications

The PowerEdgeR7715 supports up to 6 standard (STD) cooling fans.

Table 1. Cooling fan specificationsCooling fan specifications
Fan type Abbreviation Also known as Label color Label image
High performance (HPR) silver fansHPR SLVR Silver SilverThis shows the High Performance Silver (HPR SLVR) fan
Very high performance (VHP) fansHPR GOLD Gold GoldThis shows the High Performance Gold (HPR GOLD) fan
High Performance Platinum (HPR Pltm) fans HPR PLTM Platinum Platinum
The image shows the HPR platinum (HPR PLTM) fan

NOTE:Cooling fans rotate at slower speed, even while the system is in standby mode, and the fan speed varies in response to changes in the ambient temperature.

Expansion card riser specifications

The PowerEdge R7715 system supports up two PCI express (PCIe) slots (Gen5 slots), dual OCP NIC, and BOSS on the HPM board.
Table 1. Expansion card slots supported on the HPM boardThis table provides information about the expansion card slots that are supported on the system.
PCIe slot Expansion card riser Processor connection Height Length Slot width
Slot 1 R1d Processor 1 Full Height Half Length x8
Slot 2 R1d, R1e, R1e_DW Processor 1 Full Height Half Length,Full Length x8, x16
Slot 3 R2n, R2m Processor 1 Low Profile , Full Height Full Length x16
Slot 4 R3a, R3b, R3b_DW, R3e (OCP) Processor 1 Full Height, Half Lenght,Full Length x8, x16
Slot 5 R3a Processor 1 Full Height Half Length x8
Slot 6 BOSS Processor 1 N/A N/A x4
Slot 7 R5b_DW, R5b, R5f, R5a Processor 1 Full Height Half Length , Full Lenght x8, x16
Slot 8 R5f, R5a Processor 1 Full Height Half Length x8, x16
Slot 9 R4a, R4b Processor 1 Low Profile, Full Height Half Length x16
Slot 10 OCP Processor 1 N/A N/A x16

Storage controller specifications

The PowerEdge R7715 system supports the following controller cards:
Table 1. Storage controller cardsThis table provides the controller cards supported on the system:
Supported storage controller cards
Internal controllers
  • PERC H365i
  • PERC H965i
  • PERC H975i
  • HBA465e
  • H965e
Internal Boot
  • Boot Optimized Storage Subsystem (BOSS-N1 DC-MHS)
Software RAID
  • N/A
NOTE:For the ESXi operating system, H975i is supported on 9.0 or later versions.

Drives

The PowerEdge R7715 system supports:
  • No backplane configuration
  • 2 x U.2 SSDs
  • 8 x 2.5-inch SAS/SATA/NVME drives
  • 8 x EDSFF E3.S Gen5 NVMe drives
  • 12 x 3.5-inch SAS/SATA drives
  • 16 x 2.5-inch SAS/SATA SSD + 8 x U.2 NVMe drives
  • 16 x 2.5-inch SAS/SATA drives
  • 16 x EDSFF E3.S Gen5 NVMe drives
  • 24 x 2.5-inch SAS/SATA drives
  • 32 x EDSFF E3.S Gen5 NVMe drives
  • 40 x EDSFF E3.S Gen5 NVMe drives
NOTE: For more information about how to hot swap NVMe PCIe SSD U.2 device, see the Dell Express Flash NVMe PCIe SSD User's Guide at Dell Support page >Browse all Products > Data Center Infrastructure >  Storage Adapters & Controllers > Dell PowerEdge Express Flash NVMe PCIe SSD > Documentation > Manuals and Documents.

GPU Specifications

The PowerEdge R7715 system supports the following GPU configurations:
  • Up to three 450 W Double wide or six 75 W single wide GPUs

DPU Specifications

The PowerEdge R7715 platform accommodates Data Processing Units (DPUs). These units are system-on-chip solutions that combine ARM cores, high-performance NICs, and programmable acceleration engines to offload and accelerate data center infrastructure services.

Table 1. Supported Data Processing Units(DPU) CardsThis table describes the feature and the specifications for the supported DPU cards in R7715
Feature NVIDIA BlueField-3 2x200 GbE B3220 NVIDIA BlueField-3 1x400 GbE B3140H *
Type Data Processing Units (DPU) Data Processing Units (DPU)
Networking 2 x 200 GbE 1x400 GbE
Form Factor FHHL FHHL
Interface PCIe Gen5 x16 PCIe Gen5 x16
Power Consumption 150 W 75 W
Compatible Risers RC 1(Slot 7), RC 2(Slot 7), RC 3(Slots 2,7), RC 4(Slots 2,7), RC 5(Slots 2,7), RC 8(Slots 2,7) TBD
NOTE: This document provides a comprehensive list of product features. However, features marked with an asterisk (*) may not be available at launch but introduced in future updates. Please note that this document does not confirm the availability or release timeline of any feature. For the most accurate and up-to-date information on feature availability, please refer to the product configurator page on dell.com.
NOTE:* Feature not available at product launch in November,2025. Please refer to the product configurator page on Dell.com to confirm feature availability.

Supported operating systems

The PowerEdge R7715 system supports the following operating systems:

  • Canonical Ubuntu Server LTS
  • Microsoft Windows Server with Hyper-V
  • RedHat Enterprise Linux
  • SUSE Linux Enterprise Server
  • VMware ESXi

For more information, go to Operating System Manuals.

NIC port specifications

The PowerEdge R7715 system supports one 10/100/1000 Mbps BMC Ethernet, up to eight PCIe Add-in cards, up to two fibre channel HBA cards, and two optional Open Compute Project (OCP) cards.
Table 1. NIC port specification for the systemThis table describes the NIC port specification for the system.
Feature Specifications
Datacenter-Secure Control Module (DC-SCM) 1 Gb Dedicated BMC Ethernet port x1
OCP NIC 3.0 card 200GbE x 2 (configurable to 400GbE x1), 100 GbE x 2, 25 GbE x 2, 25 GbE x 4 , 10 GbE x 4, 10 GbE x 2, 1 GbE x 4
PCIe Add-in Card (AIC) NIC 400 GbE x 1, 100 Gbe x 2
Fibre channel HBA FC32, FC64

USB ports specifications

Table 1. PowerEdge R7715 USB specificationsThe following table shows the USB specifications for the system:
Front Rear Internal (Optional)
USB port type No. of ports USB port type No. of ports USB port type No. of ports
USB 2.0-Type A compliant port One (optional-LCP KVM) USB 3.1-Type A compliant port Two Internal USB 3.1-Type A compliant port One
USB Type C dual-mode host/iDRAC Direct Port One

VGA ports specifications

The PowerEdge R7715 system supports DB-15 VGA port on the rear DC-SCM.

Video specifications

Table 1. Supported video resolution optionsThis table describes the supported front video resolution options for the system.
Resolution Refresh Rate Color depth (bits)
1024 x 768 60 8, 16, 32
1280 x 800 60 8, 16, 32
1280 x 1024 60 8, 16, 32
1360 x 768 60 8, 16, 32
1440 x 900 60 8, 16, 32
1600 x 900 60 8, 16, 32
1600 x 1200 60 8, 16, 32
1680 x 1050 60 8, 16, 32
1920 x 1080 60 8, 16, 32
1920 x 1200 60 8, 16, 32

Environmental specifications

NOTE:For additional information about environmental certifications, refer to the Product Environmental Datasheet located with the Manuals & Documents on Dell Support.
Table 1. Continuous Operation Specifications for ASHRAE A2 This table describes the operational climatic range for category A2.
Temperature Specifications
Allowable continuous operations
Temperature range for altitudes <= 900 m (<= 2953 ft) 10–35°C (50–95°F) with no direct sunlight on the equipment
Humidity percent range (non-condensing at all times) 8% RH with -12°C minimum dew point to 80% RH with 21°C (69.8°F) maximum dew point
Operational altitude de-rating Maximum temperature is reduced by 1°C/300 m (1.8°F/984 Ft) above 900 m (2953 Ft)
Table 2. Continuous Operation Specifications for ASHRAE A3 This table describes the operational climatic range for category A3.
Temperature Specifications
Allowable continuous operations
Temperature range for altitudes <= 900 m (<= 2953 ft) 5–40°C (41–104°F) with no direct sunlight on the equipment
Humidity percent range (non-condensing at all times) 8% RH with -12°C minimum dew point to 85% RH with 24°C (75.2°F) maximum dew point
Operational altitude de-rating Maximum temperature is reduced by 1°C/175 m (1.8°F/574 Ft) above 900 m (2953 Ft)
Table 3. Continuous Operation Specifications for ASHRAE A4 This table describes the operational climatic range for category A4.
Temperature Specifications
Allowable continuous operations
Temperature range for altitudes <= 900 m (<= 2953 ft) 5–45°C (41–113°F) with no direct sunlight on the equipment
Humidity percent range (non-condensing at all times) 8% RH with -12°C minimum dew point to 90% RH with 24°C (75.2°F) maximum dew point
Operational altitude de-rating Maximum temperature is reduced by 1°C/125 m (1.8°F/410 Ft) above 900 m (2953 Ft)
Table 4. Continuous Operation Specifications for Rugged Environment This table describes the operational climatic range for category A4.
Temperature Specifications
Allowable continuous operations
Temperature range for altitudes <= 900 m (<= 2953 ft) 5–55°C (41–131°F) with no direct sunlight on the equipment
Humidity percent range (non-condensing at all times) 8% RH with -12°C minimum dew point to 90% RH with 24°C (75.2°F) maximum dew point
Operational altitude de-rating Maximum temperature is reduced by 1°C/125 m (1.8°F/410 Ft) above 900 m (2953 Ft)
Table 5. Common Environmental Specifications for ASHRAE A2, A3, A4 and Rugged This table describes the shared requirements across all categories.
Temperature Specifications
Allowable continuous operations
Maximum temperature gradient (applies to both operation and non-operation) 20°C in an hour* (36°F in an hour) and 5°C in 15 minutes (9°F in 15 minutes), 5°C in an hour* (9°F in an hour) for tape
NOTE:* - Per ASHRAE thermal guidelines for tape hardware, these are not instantaneous rates of temperature change.
Non-operational temperature limits
  • -40°C to 65°C (-40°F to 149°F) applicable for air cooling configuration
  • -40°C to -5°C (-40°F to 23°F**) applicable for DLC configuration
NOTE:** Liquid filled components, or systems/solutions containing liquid filled components are limited to approximately 5°C above their freeze point. At this time the only authorized liquid coolant is Recohem PG25 with a freeze point between -9°C and -13°C, therefore the lower non-operational temperature limit is -5°C. Components and systems/solutions that can contain liquid but do not at the time of testing shall be tested to the -40°C lower non-operational temperature limit.
Non-operational humidity limits 5% to 95% RH with 27°C (80.6°F) maximum dew point
Maximum non-operational altitude 12,000 meters (39,370 feet)
Maximum operational altitude 3,048 meters (10,000 feet)
Table 6. Maximum vibration specificationsThe maximum vibration specification of an operational system is 0.26 Grms at 5 Hz to 350 Hz (all operation orientations).The maximum vibration specification of a nonoperational system is 1.88 Grms at 10 Hz to 500 Hz for 15 minutes (all six sides tested).
Maximum vibration Specifications
Operating 0.21 Grms at 5 Hz to 500 Hz (all operation orientations)
Storage 1.38 Grms at 7 Hz to 250 Hz for 15 minutes (all six sides tested)
Table 7. Maximum shock pulse specificationsThe maximum shock specification of an operational system is six consecutively executed shock pulses in the positive and negative x, y, and z axis of 40 G for up to 2.3 ms. The maximum shock specification of a nonoperational system is six consecutively executed shock pulses in the positive and negative x, y, and z axis (one pulse on each side of the system) of 71 G for up to 2 ms.
Maximum shock pulse Specifications
Operating Six consecutively executed shock pulses in the positive and negative x, y, and z axis of 6 G for up to 11 ms.
Storage Six consecutively executed shock pulses in the positive and negative x, y, and z axis (one pulse on each side of the system) of 71 G for up to 2 ms.

Particulate and gaseous contamination specifications

The following table defines the limitations that help avoid any equipment damage or failure from particulates and gaseous contamination. If the levels of particulates or gaseous pollution exceed the specified limitations and result in equipment damage or failure, you must rectify the environmental conditions. Remediation of environmental conditions is the responsibility of the customer.

Table 1. Particulate contamination specificationsAir filtration specification: Data center air filtration as defined by ISO Class 8 per ISO 14644-1 should have a 95% upper confidence limit. Note: This condition applies only to data center environments. Air filtration requirements do not apply to IT equipment designed to be used outside a data center, in environments such as an office or factory floor. Note: Air entering the data center must have MERV11 or MERV13 filtration. Conductive dust specification: Air must be free of conductive dust, zinc whiskers, or other conductive particles. Note: This condition applies to data center and non-data center environments. Corrosive dust specification: Air must be free of corrosive dust. Residual dust present in the air must have a deliquescent point less than 60% relative humidity. Note: This condition applies to data center and non-data center environments.
Particulate contamination Specifications
Air filtration: Conventional Data Center only Data center air filtration as defined by ISO Class 8 per ISO 14644-1 with a 95% upper confidence limit
NOTE: Filtering room air with a MERV8 filter, as specified in ANSI/ASHRAE Standard 127, is a recommended method for achieving the necessary environmental conditions.
NOTE:Air entering the data center must have MERV11 or MERV13 filtration.
NOTE:This condition applies to data center environments only. Air filtration requirements do not apply to IT equipment designed to be used outside a data center, in environments such as an office or factory floor.
Walk-Up Edge Data Center or Cabinet (sealed, closed loop environment) Filtration is not required for cabinets that are anticipated to be opened six times or less per year. Class 8 per ISO 1466-1 filtration as defined above is required otherwise.
NOTE: In environments commonly above ISA-71 Class G1 or that may have known challenges, special filters may be required.
Conductive dust: data center and non-data center environments Air must be free of conductive dust, zinc whiskers, or other conductive particles.
NOTE: Conductive dust, which can interfere with equipment operation, can originate from various sources, including manufacturing processes and zinc whiskers that may develop on the plating of raised floor tiles.
NOTE:This condition applies to data center and non-data center environments.
Corrosive dust: data center and non-data center environments
  • Air must be free of corrosive dust.
  • Residual dust present in the air must have a deliquescent point less than 60% relative humidity.
NOTE:This condition applies to data center and non-data center environments.
Table 2. Gaseous contamination specificationsThe copper coupon corrosion rate is <300 Å/month per Class G1 as defined by ANSI/ISA71.04. The silver coupon corrosion rate is <200 Å/month as defined by ANSI/ISA71.04.
Gaseous contamination Specifications Notes
Copper coupon corrosion rate ISA-71 Class G1: <300 Å/month Per ANSI/ISA71.04
Silver coupon corrosion rate ISA-71 Class G1: <200 Å/month Per ANSI/ISA71.04

Thermal restriction matrix

Table 1. Label referenceThis table describes the label references used in the restriction tables.
Label Description
STD Standard
HPR (Silver) High performance Silver (HPR SLVR) fan
HPR (Gold) High performance Gold (HPR GOLD) fan
HSK Heat sink
LP Low profile
FH Full height
DLC Direct Liquid Cooling
Table 2. Processor and heat sink matrixThis table describes the processor and heat sink restriction matrix.
Heat sink Processor TDP
2U-Ext Regular cooling
NOTE:The configuration's ambient temperature is dictated by its critical component. For example, if the processor's ambient temperature is 35°C, the DIMM is 35°C, and the GPU is 30°C, the configuration's ambient temperature can only be 30°C.
Table 3. CPU thermal restriction matrix for Air cooling Non-GPU configurationThe following table shows the CPU thermal restriction matrix for Air cooling Non-GPU configuration.
CPU thermal restriction matrix for Air cooling Non-GPU configuration
2U-Ext HSK (5XD0R) ; Silver Fan (6R09C) ; HPR Gold Fan (7F0CF) , HPR P Fan (5337J)
CPU cTDP Max cTDP Core Count 24 x 2.5-inch 16 x 2.5-inch 16 x EDSFF E3.S NVMe 32 x EDSFF E3.S NVMe No Backplane/ 2 x U.2 16 x EDSFF E3.S NVMe
Regular Air shroud
Supported at 35°C
9015 125 155 8 2U-Ext HSK

Silver Fan

2U-Ext HSK

Silver Fan

2U-Ext HSK

Silver Fan

2U-Ext HSK

Silver Fan

2U-Ext HSK

Silver Fan

2U-Ext HSK

Silver Fan

9115 125 155 16 2U-Ext HSK

Silver Fan

2U-Ext HSK

Silver Fan

2U-Ext HSK

Silver Fan

2U-Ext HSK

Silver Fan

2U-Ext HSK

Silver Fan

2U-Ext HSK

Silver Fan

9135 200 240 16 2U-Ext HSK

Silver Fan

2U-Ext HSK

Silver Fan

2U-Ext HSK

Silver Fan

2U-Ext HSK

Silver Fan

2U-Ext HSK

Silver Fan

2U-Ext HSK

Silver Fan

9255 200 240 24 2U-Ext HSK

Silver Fan

2U-Ext HSK

Silver Fan

2U-Ext HSK

Silver Fan

2U-Ext HSK

Silver Fan

2U-Ext HSK

Silver Fan

2U-Ext HSK

Silver Fan

9335 280 300 32 2U-Ext HSK

Silver Fan

2U-Ext HSK

Silver Fan

2U-Ext HSK

Silver Fan

2U-Ext HSK

Silver Fan

2U-Ext HSK

Silver Fan

2U-Ext HSK

Silver Fan

9355P 280 300 32 2U-Ext HSK

Silver Fan

2U-Ext HSK

Silver Fan

2U-Ext HSK

Silver Fan

2U-Ext HSK

Silver Fan

2U-Ext HSK

Silver Fan

2U-Ext HSK

Silver Fan

9455 300 300 48 2U-Ext HSK

Silver Fan

2U-Ext HSK

Silver Fan

2U-Ext HSK

Silver Fan

2U-Ext HSK

Silver Fan

2U-Ext HSK

Silver Fan

2U-Ext HSK

Silver Fan

9535 300 300 64 2U-Ext HSK

Silver Fan

2U-Ext HSK

Silver Fan

2U-Ext HSK

Silver Fan

2U-Ext HSK

Silver Fan

2U-Ext HSK

Silver Fan

2U-Ext HSK

Silver Fan

9175F 320 400 16 2U-Ext HSK

HPR Gold Fan

2U-Ext HSK

HPR Gold Fan

2U-Ext HSK

HPR Gold Fan

2U-Ext HSK

HPR Gold Fan

2U-Ext HSK

HPR Gold Fan

2U-Ext HSK

HPR Gold Fan

9275F 320 400 24 2U-Ext HSK

HPR Gold Fan

2U-Ext HSK

HPR Gold Fan

2U-Ext HSK

HPR Gold Fan

2U-Ext HSK

HPR Gold Fan

2U-Ext HSK

HPR Gold Fan

2U-Ext HSK

HPR Gold Fan

9375F 320 400 32 2U-Ext HSK

HPR Gold Fan

2U-Ext HSK

HPR Gold Fan

2U-Ext HSK

HPR Gold Fan

2U-Ext HSK

HPR Gold Fan

2U-Ext HSK

HPR Gold Fan

2U-Ext HSK

HPR Gold Fan

9475F 400 400 48 2U-Ext HSK

HPR Gold Fan

2U-Ext HSK

HPR Gold Fan

2U-Ext HSK

HPR Gold Fan

2U-Ext HSK

HPR Gold Fan

2U-Ext HSK

HPR Gold Fan

2U-Ext HSK

HPR Gold Fan

9555P 360 400 64 2U-Ext HSK

HPR Gold Fan

2U-Ext HSK

HPR Gold Fan

2U-Ext HSK

HPR Gold Fan

2U-Ext HSK

HPR Gold Fan

2U-Ext HSK

HPR Gold Fan

2U-Ext HSK

HPR Gold Fan

9575F 400 400 64 2U-Ext HSK

HPR Gold Fan

2U-Ext HSK

HPR Gold Fan

2U-Ext HSK

HPR Gold Fan

2U-Ext HSK

HPR Gold Fan

2U-Ext HSK

HPR Gold Fan

2U-Ext HSK

HPR Gold Fan

9655P 320 400 96 2U-Ext HSK

HPR Gold Fan

2U-Ext HSK

HPR Gold Fan

2U-Ext HSK

HPR Gold Fan

2U-Ext HSK

HPR Gold Fan

2U-Ext HSK

HPR Gold Fan

2U-Ext HSK

HPR Gold Fan

9745 400 400 128 2U-Ext HSK

HPR Gold Fan

2U-Ext HSK

HPR Gold Fan

2U-Ext HSK

HPR Gold Fan

2U-Ext HSK

HPR Gold Fan

2U-Ext HSK

HPR Gold Fan

2U-Ext HSK

HPR Gold Fan

9825 390 400 144 2U-Ext HSK

HPR Gold Fan

2U-Ext HSK

HPR Gold Fan

2U-Ext HSK

HPR Gold Fan

2U-Ext HSK

HPR Gold Fan

2U-Ext HSK

HPR Gold Fan

2U-Ext HSK

HPR Gold Fan

9845 390 400 160 2U-Ext HSK

HPR Gold Fan

2U-Ext HSK

HPR Gold Fan

2U-Ext HSK

HPR Gold Fan

2U-Ext HSK

HPR Gold Fan

2U-Ext HSK

HPR Gold Fan

2U-Ext HSK

HPR Gold Fan

Table 4. Memory thermal restriction matrix for Air Cooling Non-GPU configurationThe following table shows the memory thermal restriction matrix for Air Cooling Non-GPU configuration
Memory thermal restriction matrix for Air Cooling Non-GPU configuration
2U-Ext HSK (5XD0R) ; Silver Fan (6R09C) ; HPR Gold Fan (7F0CF) , HPR P Fan (5337J)
memory 24 x 2.5-inch 16 x 2.5-inch 16 x EDSFF E3.S NVMe 32 x EDSFF E3.S NVMe No Backplane/ 2 x U.2 16 x EDSFF E3.S NVMe
Regular Air shroud
Supported at 35°C
16 GB RDIMM Silver Fan Silver Fan Silver Fan Silver Fan Silver Fan Silver Fan
32 GB RDIMM Silver Fan Silver Fan Silver Fan Silver Fan Silver Fan Silver Fan
64 GB RDIMM Silver Fan Silver Fan Silver Fan Silver Fan Silver Fan Silver Fan
96 GB RDIMM HPR Gold Fan HPR Gold Fan HPR Gold Fan HPR Gold Fan HPR Gold Fan HPR Gold Fan
128 GB RDIMM HPR Gold Fan HPR Gold Fan HPR Gold Fan HPR Gold Fan HPR Gold Fan HPR Gold Fan
256 GB RDIMM HPR Gold Fan HPR Gold Fan HPR Gold Fan HPR Gold Fan HPR Gold Fan HPR Gold Fan
Table 5. GPU thermal restriction matrix for Air Cooling Non-GPU configurationThe following table shows the memory thermal restriction matrix for Air Cooling Non-GPU configuration
GPU thermal restriction matrix for Air Cooling Non-GPU configuration
2U-Ext HSK (5XD0R) ; Silver Fan (6R09C) ; HPR Gold Fan (7F0CF) , HPR P Fan (5337J)
GPU 24 x 2.5-inch 16 x 2.5-inch 16 x EDSFF E3.S NVMe 32 x EDSFF E3.S NVMe No Backplane/ 2 x U.2 16 x EDSFF E3.S NVMe
Regular Air shroud
NOTE:** Components that support max 30°C.
NOTE:Components without ** support max 35°C.
L4 24 GB HPR Gold Fan** HPR Gold Fan HPR Gold Fan HPR Gold Fan HPR Gold Fan HPR Gold Fan
Table 6. CPU thermal restriction matrix for Air cooling GPU configurationThe following table shows the CPU thermal restriction matrix for Air cooling GPU configuration.
CPU thermal restriction matrix for Air cooling GPU configuration
1U GPU HSK (2K16D) , HPR P Fan (5337J)
CPU cTDP Max cTDP Core Count 16 x 2.5-inch 8 x 2.5-inch 8 x EDSFF E3.S NVMe
GPU Air shroud
Supported at 35°C
9015 125 155 8 1U GPU HSK

HPR P Fan

1U GPU HSK

HPR P Fan

1U GPU HSK

HPR P Fan

9115 125 155 16 1U GPU HSK

HPR P Fan

1U GPU HSK

HPR P Fan

1U GPU HSK

HPR P Fan

9135 200 240 16 1U GPU HSK

HPR P Fan

1U GPU HSK

HPR P Fan

1U GPU HSK

HPR P Fan

9255 200 240 24 1U GPU HSK

HPR P Fan

1U GPU HSK

HPR P Fan

1U GPU HSK

HPR P Fan

9335 280 300 32 1U GPU HSK

HPR P Fan

1U GPU HSK

HPR P Fan

1U GPU HSK

HPR P Fan

9355P 280 300 32 1U GPU HSK

HPR P Fan

1U GPU HSK

HPR P Fan

1U GPU HSK

HPR P Fan

9455 300 300 48 1U GPU HSK

HPR P Fan

1U GPU HSK

HPR P Fan

1U GPU HSK

HPR P Fan

9535 300 300 64 1U GPU HSK

HPR P Fan

1U GPU HSK

HPR P Fan

1U GPU HSK

HPR P Fan

9175F 320 400 16 1U GPU HSK

HPR P Fan

1U GPU HSK

HPR P Fan

1U GPU HSK

HPR P Fan

9275F 320 400 24 Not Support Not Support Not Support
9375F 320 400 32 1U GPU HSK

HPR P Fan

1U GPU HSK

HPR P Fan

1U GPU HSK

HPR P Fan

9475F 400 400 48 1U GPU HSK

HPR P Fan

1U GPU HSK

HPR P Fan

1U GPU HSK

HPR P Fan

9555P 360 400 64 1U GPU HSK

HPR P Fan

1U GPU HSK

HPR P Fan

1U GPU HSK

HPR P Fan

9575F 400 400 64 1U GPU HSK

HPR P Fan

1U GPU HSK

HPR P Fan

1U GPU HSK

HPR P Fan

9655P 320 400 96 1U GPU HSK

HPR P Fan

1U GPU HSK

HPR P Fan

1U GPU HSK

HPR P Fan

9745 400 400 128 1U GPU HSK

HPR P Fan

1U GPU HSK

HPR P Fan

1U GPU HSK

HPR P Fan

9825 390 400 144 1U GPU HSK

HPR P Fan

1U GPU HSK

HPR P Fan

1U GPU HSK

HPR P Fan

9845 390 400 160 1U GPU HSK

HPR P Fan

1U GPU HSK

HPR P Fan

1U GPU HSK

HPR P Fan

Table 7. Memory thermal restriction matrix for Air Cooling GPU configurationThe following table shows the memory thermal restriction matrix for air cooling configuration.
Memory thermal restriction matrix for Air Cooling GPU configuration
2U-Ext HSK (5XD0R) ; Silver Fan (6R09C) ; HPR Gold Fan (7F0CF) , HPR P Fan (5337J)
memory 16 x 2.5-inch 8 x 2.5-inch 8 x EDSFF E3.S NVMe
Regular Air shroud
Supported at 35°C
16 GB RDIMM HPR P Fan HPR P Fan HPR P Fan
32 GB RDIMM HPR P Fan HPR P Fan HPR P Fan
64 GB RDIMM HPR P Fan HPR P Fan HPR P Fan
96 GB RDIMM HPR P Fan HPR P Fan HPR P Fan
128 GB RDIMM HPR P Fan HPR P Fan HPR P Fan
256 GB RDIMM HPR P Fan HPR P Fan HPR P Fan
Table 8. CPU thermal restriction matrix for Direct Liquid Cooling Non-GPU configurationThe following table shows the CPU thermal restriction matrix for Direct Liquid Cooling Non-GPU configuration.
CPU thermal restriction matrix for Direct Liquid Cooling Non-GPU configuration
DLC Module (4JWWY) ; Silver Fan (6R09C) ; HPR Gold Fan (7F0CF)
CPU cTDP Max cTDP Core Count 24 x U.2 8 x 2.5-inch 16 x 2.5-inch 8 x EDSFF E3.S NVMe
Regular Air shroud
NOTE:Components support max 35°C.
9015 125 155 8 DLC Module

Silver Fan

DLC Module

Silver Fan

DLC Module

Silver Fan

DLC Module

Silver Fan

9115 125 155 16 DLC Module

Silver Fan

DLC Module

Silver Fan

DLC Module

Silver Fan

DLC Module

Silver Fan

9135 200 240 16 DLC Module

Silver Fan

DLC Module

Silver Fan

DLC Module

Silver Fan

DLC Module

Silver Fan

9255 200 240 24 DLC Module

Silver Fan

DLC Module

Silver Fan

DLC Module

Silver Fan

DLC Module

Silver Fan

9335 280 300 32 DLC Module

Silver Fan

DLC Module

Silver Fan

DLC Module

Silver Fan

DLC Module

Silver Fan

9355P 280 300 32 DLC Module

Silver Fan

DLC Module

Silver Fan

DLC Module

Silver Fan

DLC Module

Silver Fan

9455 300 300 48 DLC Module

Silver Fan

DLC Module

Silver Fan

DLC Module

Silver Fan

DLC Module

Silver Fan

9535 300 300 64 DLC Module

Silver Fan

DLC Module

Silver Fan

DLC Module

Silver Fan

DLC Module

Silver Fan

9175F 320 400 16 DLC Module

Silver Fan

DLC Module

Silver Fan

DLC Module

Silver Fan

DLC Module

Silver Fan

9275F 320 400 24 DLC Module

Silver Fan

DLC Module

Silver Fan

DLC Module

Silver Fan

DLC Module

Silver Fan

9375F 320 400 32 DLC Module

Silver Fan

DLC Module

Silver Fan

DLC Module

Silver Fan

DLC Module

Silver Fan

9475F 400 400 48 DLC Module

Silver Fan

DLC Module

Silver Fan

DLC Module

Silver Fan

DLC Module

Silver Fan

9555P 360 400 64 DLC Module

Silver Fan

DLC Module

Silver Fan

DLC Module

Silver Fan

DLC Module

Silver Fan

9575F 400 400 64 DLC Module

Silver Fan

DLC Module

Silver Fan

DLC Module

Silver Fan

DLC Module

Silver Fan

9655P 320 400 96 DLC Module

Silver Fan

DLC Module

Silver Fan

DLC Module

Silver Fan

DLC Module

Silver Fan

9745 400 400 128 DLC Module

Silver Fan

DLC Module

Silver Fan

DLC Module

Silver Fan

DLC Module

Silver Fan

9825 390 400 144 DLC Module

Silver Fan

DLC Module

Silver Fan

DLC Module

Silver Fan

DLC Module

Silver Fan

9845 390 400 160 DLC Module

Silver Fan

DLC Module

Silver Fan

DLC Module

Silver Fan

DLC Module

Silver Fan

Table 9. Memory thermal restriction matrix for Direct Liquid Cooling Non-GPU configurationThe following table shows the Memory thermal restriction matrix for Direct Liquid Cooling Non-GPU configuration.
Memory thermal restriction matrix for Direct Liquid Cooling Non-GPU configuration
DLC Module (4JWWY) ; Silver Fan (6R09C), HPR Gold Fan (7F0CF)
Memory 24 x U.2 8 x 2.5-inch 16 x 2.5-inch 8 x EDSFF E3.S NVMe
Regular Air shroud
NOTE:Components support max 35°C.
16 GB RDIMM Silver Fan Silver Fan Silver Fan Silver Fan
32 GB RDIMM Silver Fan Silver Fan Silver Fan Silver Fan
64 GB RDIMM Silver Fan Silver Fan Silver Fan Silver Fan
96 GB RDIMM HPR Gold Fan HPR Gold Fan HPR Gold Fan HPR Gold Fan
128 GB RDIMM HPR Gold Fan HPR Gold Fan HPR Gold Fan HPR Gold Fan
256 GB RDIMM HPR Gold Fan HPR Gold Fan HPR Gold Fan HPR Gold Fan
Table 10. GPU thermal restriction matrix for Direct Liquid Cooling Non-GPU configurationThe following table shows the GPU thermal restriction matrix for Direct Liquid Cooling Non-GPU configuration.
GPU thermal restriction matrix for Direct Liquid Cooling Non-GPU configuration
DLC Module (4JWWY) ; Silver Fan (6R09C), HPR Gold Fan (7F0CF)
GPU 24 x U.2 8 x 2.5-inch 16 x 2.5-inch 8 x EDSFF E3.S NVMe
Regular Air shroud
NOTE:** Components that support max 30°C.
NOTE:Components without ** support max 35°C.
L4 24 GB HPR Gold Fan HPR Gold Fan HPR Gold Fan HPR Gold Fan
Table 11. CPU thermal restriction matrix for Direct Liquid Cooling GPU configurationThe following table shows the CPU thermal restriction matrix for Direct Liquid Cooling GPU configuration
CPU thermal restriction matrix for Direct Liquid Cooling GPU configuration
DLC Module(4JWWY), HPR Gold Fan (7F0CF)
CPU cTDP Max cTDP Core Count 8 x 2.5-inch 16 x 2.5-inch 8 x EDSFF E3.S NVMe
GPU Air shroud
Supported at 35°C
9015 125 155 8 DLC Module

HPR Gold Fan

DLC Module

HPR Gold Fan

DLC Module

HPR Gold Fan

9115 125 155 16 DLC Module

HPR Gold Fan

DLC Module

HPR Gold Fan

DLC Module

HPR Gold Fan

9135 200 240 16 DLC Module

HPR Gold Fan

DLC Module

HPR Gold Fan

DLC Module

HPR Gold Fan

9255 200 240 24 DLC Module

HPR Gold Fan

DLC Module

HPR Gold Fan

DLC Module

HPR Gold Fan

9335 280 300 32 DLC Module

HPR Gold Fan

DLC Module

HPR Gold Fan

DLC Module

HPR Gold Fan

9355P 280 300 32 DLC Module

HPR Gold Fan

DLC Module

HPR Gold Fan

DLC Module

HPR Gold Fan

9455 300 300 48 DLC Module

HPR Gold Fan

DLC Module

HPR Gold Fan

DLC Module

HPR Gold Fan

9535 300 300 64 DLC Module

HPR Gold Fan

DLC Module

HPR Gold Fan

DLC Module

HPR Gold Fan

9175F 320 400 16 DLC Module

HPR Gold Fan

DLC Module

HPR Gold Fan

DLC Module

HPR Gold Fan

9275F 320 400 24 TBD TBD TBD
9375F 320 400 32 DLC Module

HPR Gold Fan

DLC Module

HPR Gold Fan

DLC Module

HPR Gold Fan

9475F 400 400 48 DLC Module

HPR Gold Fan

DLC Module

HPR Gold Fan

DLC Module

HPR Gold Fan

9555P 360 400 64 DLC Module

HPR Gold Fan

DLC Module

HPR Gold Fan

DLC Module

HPR Gold Fan

9575F 400 400 64 DLC Module

HPR Gold Fan

DLC Module

HPR Gold Fan

DLC Module

HPR Gold Fan

9655P 320 400 96 DLC Module

HPR Gold Fan

DLC Module

HPR Gold Fan

DLC Module

HPR Gold Fan

9745 400 400 128 DLC Module

HPR Gold Fan

DLC Module

HPR Gold Fan

DLC Module

HPR Gold Fan

9825 390 400 144 DLC Module

HPR Gold Fan

DLC Module

HPR Gold Fan

DLC Module

HPR Gold Fan

9845 390 400 160 DLC Module

HPR Gold Fan

DLC Module

HPR Gold Fan

DLC Module

HPR Gold Fan

Table 12. Memory thermal restriction matrix for Liquid Cooling GPU configurationThe following table shows the memory thermal restriction matrix for Liquid cooling GPU configuration.
Memory thermal restriction matrix for Liquid Cooling GPU configuration
DLC Module(4JWWY), HPR Gold Fan (7F0CF)
memory 16 x 2.5-inch 8 x 2.5-inch 8 x EDSFF E3.S NVMe
GPU Air shroud
Supported at 35°C
16 GB RDIMM HPR Gold Fan HPR Gold Fan HPR Gold Fan
32 GB RDIMM HPR Gold Fan HPR Gold Fan HPR Gold Fan
64 GB RDIMM HPR Gold Fan HPR Gold Fan HPR Gold Fan
96 GB RDIMM HPR Gold Fan HPR Gold Fan HPR Gold Fan
128 GB RDIMM HPR Gold Fan HPR Gold Fan HPR Gold Fan
256 GB RDIMM HPR Gold Fan HPR Gold Fan HPR Gold Fan

Thermal air restrictions

Fresh air environment

  • Two PSUs are required in redundant mode, however a single PSU failure is not supported.
  • PCIe SSD is not supported.
  • 128 GB or greater capacity DIMMs are not supported.
  • GPU and FPGA are not supported.
  • CPU TDP equal or greater than 180 W are not supported.
  • Rear drives are not supported.
  • Non-Dell qualified peripheral cards and/or peripheral cards greater than 25 W are not supported.
Table 1. Air cooling configuration thermal restriction for AHSRAE A3 and A4This table provides information about ASHRAE A3 and A4 restrictions for air cooling configuration.
ASHRAE A3/40°C (104°F) A4/45°C (113°F)
Front storage 12 x 3.5” SAS is not supported
Fan type HPR Sliver Fan 6R09C is required
CPU CPU TDP ≥ 165W are not supported CPU TDP ≥ 125 W are not supported
Memory 128 GB and higher capacity RDIMMS are not supported.
PCIe card Non-Dell qualified peripheral cards and consuming power greater than 25 W are not supported.
GPU GPU cards are not supported.
Rear storage Not supported
OCP Supported with 85°C (185°F) active optic cable. Supported with 85°C (185°F) active optic cable and card Tier <4
PSU Two PSUs are required in redundant mode. System performance may be reduced in the event of a PSU failure.
BOSS Support BOSS-N1
Table 2. Liquid cooling configuration thermal restriction for AHSRAE A3 and A4This table provides information about ASHRAE A3 and A4 restrictions for air cooling configuration.
ASHRAE A3/40°C (104°F) A4/45°C (113°F)
Front storage 3.5’’ / E.3 config is not supported
Fan type HPR Gold Fan (7F0CF) or up are required
PCISSD Not Supported
Memory 128GB and higher Capacity RDIMMS are not supported.
PCIe card Non-Dell qualified peripheral cards and consuming power greater than 25 W are not supported.
GPU GPU cards are not supported.
Rear storage Not supported
OCP Supported with 85°C (185°F) active optic cable. Not supported
PSU Two PSUs are required in redundant mode. System performance may be reduced in the event of a PSU failure.
BOSS Supported Not supported