Chassis dimensions

| Xa | Xb | Y | Za | Zb | Zc |
|---|---|---|---|---|---|
| 482.0 mm (18.97 inches) | 434.0 mm (17.08 inches) | 86.8 mm (3.41 inches) | 35.84 mm (1.4 inches)With bezel 22.0 mm (0.87 inches) | 700.7 mm (27.58 inches)Ear to Rear wall | 736.29 mm (28.98 inches)Ear to PSU handle |
System weight
| System configuration | Maximum weight (with all drives/SSDs) |
|---|---|
| A server with fully populated drives | 34.4 kg (75.84 lb) |
| A server without drives and PSU installed | 23.3 kg (51.37 lb) |
PSU specifications
The PowerEdgeR7625system supports up to two AC or DC power supply units (PSUs).
| PSU | Class | Heat dissipation (maximum) (BTU/hr) | Frequency (Hz) | Voltage | AC | DC | Current (A) | |
|---|---|---|---|---|---|---|---|---|
| High line wattage | Low line wattage | |||||||
| 800 W Mixed Mode | Platinum | 3000 | 50/60 | 100-240 V AC | 800 W | 800 W | N/A | 9.2-4.7 |
| 3000 | N/A | 240 V DC | N/A | N/A | 800 W | 3.8 | ||
| 1100 W Mixed Mode | Titanium | 4125 | 50/60 | 100-240 V AC | 1100 W | 1050 W | N/A | 12-6.3 |
| 4125 | N/A | 240 V DC | N/A | N/A | 1100 W | 5.2 | ||
| 1400 W Mixed Mode | Platinum | 5250 | 50/60 | 100-240 V AC | 1400 W | 1050 W | N/A | 12-8 |
| 5250 | N/A | 240 V DC | N/A | N/A | 1400 W | 6.6 | ||
| Titanium | 5250 | 50/60 | 100-240 V AC | 1400 W | 1050 W | N/A | 12-8 | |
| 5250 | N/A | 240 V DC | N/A | N/A | 1400 W | 6.5 | ||
| Titanium | 5250 | 50/60 | 277 V AC | 1400 W | 1050 W | N/A | 5.8 | |
| 5250 | N/A | 336 V DC | N/A | N/A | 1400 W | 5.17 | ||
| 1800 W Mixed Mode | Titanium | 6610 | 50/60 | 200-240 V AC | 1800 W | N/A | N/A | 10 |
| 6610 | N/A | 240 V DC | N/A | N/A | 1800 W | 8.2 | ||
| 2400 W Mixed Mode | Platinum | 9000 | 50/60 | 100-240 V AC | 2400 W | 1400 W | N/A | 16-13.5 |
| 9000 | N/A | 240 V DC | N/A | N/A | 2400 W | 11.2 | ||
| 2800 W Mixed Mode | Titanium | 10500 | 50/60 | 200-240 V AC | 2800 W | N/A | N/A | 15.6 |
| 10500 | N/A | 240 V DC | N/A | N/A | 2800 W | 13.6 | ||
| 3200 W Mixed Mode | Titanium | 12000 | 50/60 | 277 V AC | 3200 W | N/A | N/A | 13 |
| 12000 | N/A | 336 V DC | N/A | N/A | 3200 W | 11.5 | ||
| 1100 W DC | N/A | 4265 | N/A | -48—(-60) V DC | N/A | N/A | 1100 W | 27 |
- HLAC stands for High-Line AC, with a range of 200 - 240 V AC.
- HVDC stands for High-Voltage DC, with 336 V DC.


| Form factor | Output | Power cable |
|---|---|---|
| Redundant 60 mm | 800 W mixed mode | C13 |
| 1100 W mixed mode | C13 | |
| 1400 W mixed mode | C13 | |
| 1400 W mixed mode 277 Vac and HVDC | APP 2006G1 | |
| 1800 W mixed mode HLAC | C15 | |
| Redundant 86 mm | 2400 W mixed mode | C19 |
| 2800 W mixed mode HLAC | C21 | |
| 3200 W mixed mode 277 Vac and HVDC | APP 2006G1 |
Cooling fan specifications
The PowerEdgeR7625system supports up to six High Performance Silver and High Performance Gold fans based on configurations.
| Fan type | Abbreviation | Label color | Label image |
|---|---|---|---|
| High performance Silver fans | HPR Silver | Silver | ![]() |
| High performance Gold fans | HPR Gold | Gold | ![]() |
Supported operating systems
The PowerEdge R7625 system supports the following operating system:
- Canonical Ubuntu Server LTS
- Microsoft Windows Server with Hyper-V
- RedHat Enterprise Linux
- SUSE Linux Enterprise Server
- VMware ESXi
- Citrix XenServer
For more information, go to OS support.
System battery specifications
The PowerEdge R7625 system uses one CR 2032 3.0-V lithium coin cell battery.
Expansion card riser specifications
| Expansion card riser | PCIe slots | Processor connection | Height | Length | Slot width |
|---|---|---|---|---|---|
| Riser 1B | Slot 1 | Processor 1 | Full Height | Half Length | x8 |
| Slot 2 | |||||
| Riser 1P | Slot 2 | Processor 1 | Full Height | Half Length / Full Length | x16 |
| Riser 1Q | Slot 1 | Processor 1 | Full Height | Half Length | x8 |
| Slot 2 | |||||
| Riser 1S | Slot 1 | Processor 1 | Full Height | Half Length / Full Length | x16 |
| Slot 2 | |||||
| Riser 2A | Slot 3 | Processor 1 | Low Profile | Half Length | x16 |
| Slot 6 | Processor 2 | ||||
| Riser 3A | Slot 5 | Processor 2 | Full Height | Half Length / Full Length | x16 |
| Riser 3B | Slot 4 | Processor 2 | Full Height | Half Length | x8 |
| Slot 5 | |||||
| Riser 4B | Slot 7 | Processor 2 | Full Height | Half Length | x8 |
| Slot 8 | |||||
| Riser 4Q | Slot 7 | Processor 2 | Full Height | Half Length | x8 |
| Slot 8 | |||||
| Riser 4P | Slot 7 | Processor 2 | Full Height | Half Length / Full Length | x16 |
Storage controller specifications
| Supported storage controller cards | |
|---|---|
Internal controllers
|
|
External controllers
|
|
Internal Boot
|
|
Software RAID
|
|
SAS Host Bus Adapters (HBA)
|
Drives
- 8 x 3.5-inch hot-swappable SAS, SATA drives
- 8 x 2.5-inch hot-swappable SAS, SATA, NVMe drives
- 12 x 3.5-inch hot-swappable SAS, SATA drives
- 16 x 2.5-inch hot-swappable SAS, SATA, NVMe drives
- 24 x 2.5-inch hot-swappable SAS, SATA, NVMe drives
- 32 x EDSFF E3.S hot-swappable NVMe Gen5 drives
- 16 x EDSFF E3.S hot-swappable NVMe Gen5 drives
- 8 x EDSFF E3.S hot-swappable NVMe Gen5 drives
- 2 x 2.5-inch (rear) hot-swappable SAS/SATA/NVMe drives
- 4 x 2.5-inch (rear) hot-swappable SAS/SATA/NVMe drives
NIC port specifications
| Feature | Specifications |
|---|---|
| LOM card (optional) | 1 GbE x 2 |
| OCP card 3.0 (optional) | 1 GbE x 4, 10 GbE x 2, 10 GbE x 4, 25 GbE x 2, 25 GbE x 4 |
| Management Interface Card (MIC) to support Dell Data Processing Unit (DPU) card (optional) | 25 GbE x 2 or 100 GbE x 2 |
VGA ports specifications
The PowerEdge R7625 system supports two DB-15 VGA port one each on the front and rear panel (optional for liquid cooling).
Video specifications
| Resolution | Refresh rate (Hz) | Color depth (bits) |
|---|---|---|
| 1024 x 768 | 60 | 8, 16, 32 |
| 1280 x 800 | 60 | 8, 16, 32 |
| 1280 x 1024 | 60 | 8, 16, 32 |
| 1360 x 768 | 60 | 8, 16, 32 |
| 1440 x 900 | 60 | 8, 16, 32 |
| 1600 x 900 | 60 | 8, 16, 32 |
| 1600 x 1200 | 60 | 8, 16, 32 |
| 1680 x 1050 | 60 | 8, 16, 32 |
| 1920 x 1080 | 60 | 8, 16, 32 |
| 1920 x 1200 | 60 | 8, 16, 32 |
Environmental specifications
| Temperature | Specifications | |
|---|---|---|
| Allowable continuous operations | ||
| Temperature range for altitudes <= 900 m (<= 2953 ft) | 10–35°C (50–95°F) with no direct sunlight on the equipment | |
| Humidity percent range (non-condensing at all times) | 8% RH with -12°C minimum dew point to 80% RH with 21°C (69.8°F) maximum dew point | |
| Operational altitude de-rating | Maximum temperature is reduced by 1°C/300 m (1.8°F/984 Ft) above 900 m (2953 Ft) | |
| Temperature | Specifications | |
|---|---|---|
| Allowable continuous operations | ||
| Temperature range for altitudes <= 900 m (<= 2953 ft) | 5–40°C (41–104°F) with no direct sunlight on the equipment | |
| Excursion Limited Operation | 5-35°C (41-95°F) Continuous Operation | |
| 35-40°C (95-104°F) 10% Annual Runtime | ||
| Humidity percent range (non-condensing at all times) | 8% RH with -12°C minimum dew point to 85% RH with 24°C (75.2°F) maximum dew point | |
| Operational altitude de-rating | Maximum temperature is reduced by 1°C/175 m (1.8°F/574 Ft) above 900 m (2953 Ft) | |
| Temperature | Specifications | |
|---|---|---|
| Allowable continuous operations | ||
| Temperature range for altitudes <= 900 m (<= 2953 ft) | 5–45°C (41–113°F) with no direct sunlight on the equipment | |
| Excursion Limited Operation | 5-35°C (41-95°F) Continuous Operation | |
| 35-40°C (95-104°F) 10% Annual Runtime | ||
| 40-45°C (104-113°F) 1% Annual Runtime | ||
| Humidity percent range (non-condensing at all times) | 8% RH with -12°C minimum dew point to 90% RH with 24°C (75.2°F) maximum dew point | |
| Operational altitude de-rating | Maximum temperature is reduced by 1°C/125 m (1.8°F/410 Ft) above 900 m (2953 Ft) | |
| Temperature | Specifications |
|---|---|
| Allowable continuous operations | |
| Maximum temperature gradient (applies to both operation and non-operation) | 20°C in an hour* (36°F in an hour) and 5°C in 15 minutes (9°F in 15 minutes), 5°C in an hour* (9°F in an hour) for tape hardware
NOTE:* - Per ASHRAE thermal guidelines for tape hardware, these are not instantaneous rates of temperature change.
|
| Non-operational temperature limits | -40 to 65°C (-40 to 149°F) |
| Non-operational humidity limits | 5% to 95% RH with 27°C (80.6°F) maximum dew point |
| Maximum non-operational altitude | 12,000 meters (39,370 feet) |
| Maximum operational altitude | 3,048 meters (10,000 feet) |
| Maximum vibration | Specifications |
|---|---|
| Operating | 0.21 Grms at 5 Hz to 500 Hz for 10 minutes (all operation orientations) |
| Storage | 1.88 Grms at 10 Hz to 500 Hz for 15 minutes (all six sides tested) |
| Maximum shock pulse | Specifications |
|---|---|
| Operating | Six consecutively executed shock pulses in the positive and negative x, y, and z axis of 6 G for up to 11 ms |
| Storage | Six consecutively executed shock pulses in the positive and negative x, y, and z axis (one pulse on each side of the system) of 71 G for up to 2 ms |
Particulate and gaseous contamination specifications
The following table defines the limitations that help avoid any equipment damage or failure from particulates and gaseous contamination. If the levels of particulates or gaseous pollution exceed the specified limitations and result in equipment damage or failure, you may need to rectify the environmental conditions. Remediation of environmental conditions is the responsibility of the customer.| Particulate contamination | Specifications |
|---|---|
| Air filtration | Data center air filtration as defined by ISO Class 8 per ISO 14644-1 with a 95% upper confidence limit
NOTE:This condition applies to data center environments only. Air filtration requirements do not apply to IT equipment designed to be used outside a data center, in environments such as an office or factory floor.
NOTE:Air entering the data center must have MERV11 or MERV13 filtration.
|
| Conductive dust | Air must be free of conductive dust, zinc whiskers, or other conductive particles
NOTE:This condition applies to data center and non-data center environments.
|
| Corrosive dust |
NOTE:This condition applies to data center and non-data center environments.
|
| Gaseous contamination | Specifications |
|---|---|
| Copper coupon corrosion rate | <300 Å/month per Class G1 as defined by ANSI/ISA71.04-2013 |
| Silver coupon corrosion rate | <200 Å/month as defined by ANSI/ISA71.04-2013 |
Particulate and gaseous contamination specifications
The following table defines the limitations that help avoid any equipment damage or failure from particulates and gaseous contamination. If the levels of particulates or gaseous pollution exceed the specified limitations and result in equipment damage or failure, you must rectify the environmental conditions. Remediation of environmental conditions is the responsibility of the customer.
| Particulate contamination | Specifications |
|---|---|
| Air filtration: Conventional Data Center only | Data center air filtration as defined by ISO Class 8 per ISO 14644-1 with a 95% upper confidence limit
NOTE: Filtering room air with a MERV8 filter, as specified in ANSI/ASHRAE Standard 127, is a recommended method for achieving the necessary environmental conditions.
NOTE:Air entering the data center must have MERV11 or MERV13 filtration.
NOTE:This condition applies to data center environments only. Air filtration requirements do not apply to IT equipment designed to be used outside a data center, in environments such as an office or factory floor.
|
| Walk-Up Edge Data Center or Cabinet (sealed, closed loop environment) | Filtration is not required for cabinets that are anticipated to be opened six times or less per year. Class 8 per ISO 1466-1 filtration as defined above is required otherwise.
NOTE: In environments commonly above ISA-71 Class G1 or that may have known challenges, special filters may be required.
|
| Conductive dust: data center and non-data center environments | Air must be free of conductive dust, zinc whiskers, or other conductive particles.
NOTE: Conductive dust, which can interfere with equipment operation, can originate from various sources, including manufacturing processes and zinc whiskers that may develop on the plating of raised floor tiles.
NOTE:This condition applies to data center and non-data center environments.
|
| Corrosive dust: data center and non-data center environments |
NOTE:This condition applies to data center and non-data center environments.
|
| Gaseous contamination | Specifications | Notes |
|---|---|---|
| Copper coupon corrosion rate | ISA-71 Class G1: <300 Å/month | Per ANSI/ISA71.04 |
| Silver coupon corrosion rate | ISA-71 Class G1: <200 Å/month | Per ANSI/ISA71.04 |
Thermal air restrictions
ASHRAE A3 environment
- Two PSUs are required in redundant mode, however single PSU failure is not supported.
- PCIe SSD is not supported.
- DIMMs greater than 32 GB are not supported.
- Both SW and DW GPGPU/FPGA are not supported.
- CPU TDP greater than 200W are not supported.
- Rear drives are not supported.
- PCIe card TDP more than 25 W is not supported.
- OCP is supported with 85C active optic cable.
ASHRAE A4 environment
- Two PSUs are required in redundant mode, however single PSU failure is not supported.
- PCIe SSD is not supported.
- DIMMs greater than 32 GB are not supported.
- Both SW and DW GPGPU/FPGA are not supported.
- CPU TDP greater than 200W are not supported.
- Rear drives are not supported.
- PCIe card TDP more than 25 W is not supported.
- OCP is supported with 85C active cable and cards Tier<=4
- BOSS N1 is not supported.
Liquid cooling: ASHRAE A3 environment
- Two PSUs are required in redundant mode, however single PSU failure is not supported.
- PCIe SSD is not supported.
- DIMMs greater than 32 GB are not supported.
- Both SW and DW GPGPU/FPGA are not supported.
- Rear drives are not supported.
- PCIe card TDP more than 25 W is not supported.
- OCP is supported with 85C active optic cable.
Liquid cooling: ASHRAE A4 environment
- Two PSUs are required in redundant mode, however single PSU failure is not supported.
- PCIe SSD is not supported.
- DIMMs greater than 32 GB are not supported.
- Both SW and DW GPGPU/FPGA are not supported.
- Rear drives are not supported.
- PCIe card TDP more than 25 W is not supported.
- OCP is supported with 85C active cable and cards Tier<=5
- BOSS N1 is not supported.
Other Restrictions
High temp spec(85C) active optics cable is required for cards,- 25Gb and above PCIe/OCP cards require DAC or 85C active optics cable.
Thermal restriction matrix
| Configuration | No BP | 8 x 2.5" U.2 | 16 x 2.5" SAS (SmartFlow) | 16 x 2.5" U.2 (SmartFlow) | 24 x 2.5" SAS | 16x2.5" SAS + 8x2.5" U.2 | 8x3.5" | 12x3.5" | |||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Rear storage | No Rear Drives | No Rear Drives | No Rear Drives | No Rear Drives | No Rear Drives | 2x Rear 2.5" w/ 2x Rear-Fan | 4x Rear 2.5 w/ 3x Rear-Fan | No Rear Drives | No Rear Drives | No Rear Drives | 2x Rear 2.5" w/ 2x Rear-Fan | 4x Rear 2.5 w/ 3x Rear-Fan | |||
| CPU cTDP Max | CPU TDP | ||||||||||||||
| CPU TDP/cTDP | 240 W | 210 W | HPR SILVER Fan
+ 2U STD HSK |
HPR SILVER Fan [75%]
+ 2U STD HSK |
HPR GOLD Fan [70%]
+ 2U EXT HSK |
||||||||||
| 200 W | |||||||||||||||
| 300 W | 290 W | HPR SILVER Fan
+ 2U EXT HSK |
HPR SILVER Fan [75%]
+ 2U EXT HSK |
HPR GOLD Fan [70%]
+ 2U EXT HSK (Note 1) |
|||||||||||
| 280 W | |||||||||||||||
| 400 W | 360 W | HPR SILVER Fan
+ 2U EXT HSK |
HPR GOLD Fan
+ 2U EXT HSK |
HPR GOLD Fan [75%]
+ 2U EXT HSK |
Requires LC | ||||||||||
| 320 W | |||||||||||||||
| 340 W | |||||||||||||||
| Memory | 16 GB RDIMM | HPR SILVER Fan | HPR GOLD Fan | HPR SILVER Fan [75%] | HPR GOLD Fan [70%] | ||||||||||
| 32 GB RDIMM | |||||||||||||||
| 64 GB RDIMM | |||||||||||||||
| 96 GB RDIMM | |||||||||||||||
| 128 GB RDIMM | HPR GOLD Fan | Not supported | Not supported | ||||||||||||
| 256 GB RDIMM (Note 2) | HPR GOLD Fan (Note 1) | ||||||||||||||
Note 1: Supported ambient temperature is 30°C.
Note 2: Support SKHYNIX RDIMM only
| Configuration | No BP | 8 x 2.5" U.2 | 16 x 2.5" SAS (SmartFlow) | 16 x 2.5" U.2 (SmartFlow) | 24 x 2.5" SAS | 16x2.5" SAS + 8x2.5" U.2 | 8x3.5" | ||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Rear storage | No Rear Drives | ||||||||||
| CPU cTDP Max | CPU TDP | Model | |||||||||
| CPU TDP/cTDP | 240 W | 210 W | 9334 | HPR GOLD Fan
+ 1U EXT HSK |
HPR GOLD Fan [75%]
+ 1U EXT HSK |
||||||
| 200 W | 9254 | ||||||||||
| 9224 | |||||||||||
| 9124 | |||||||||||
| 300 W | 290 W | 9634 | |||||||||
| 280 W | 9534 | ||||||||||
| 290 W | 9454 | ||||||||||
| 280 W | 9354 | ||||||||||
| 400 W | 360 W | 9654 | HPR GOLD Fan
+ 1U EXT HSK |
Not Supported | Requires LC | ||||||
| 9554 | HPR GOLD Fan
+ 1U EXT HSK (Note 1) |
||||||||||
| 9474F | |||||||||||
| 320 W | 9374F | ||||||||||
| 9274F | HPR GOLD Fan
+ 1U EXT HSK |
||||||||||
| 9174F | |||||||||||
| Memory | 16 GB RDIMM | HPR GOLD Fan | HPR GOLD Fan [75%] | ||||||||
| 32 GB RDIMM | |||||||||||
| 64 GB RDIMM | |||||||||||
| 96 GB RDIMM | |||||||||||
| 128 GB RDIMM | HPR GOLD Fan | Not Supported | Not Supported | ||||||||
| 256 GB RDIMM (Note 3) | HPR GOLD Fan (Note 1) | ||||||||||
| GPU | A2 16 GB | HPR GOLD Fan | HPR GOLD Fan [75%] (Note 1) | ||||||||
| A16 64GB | HPR GOLD Fan [75%] | ||||||||||
| A30 24GB | |||||||||||
| A40 48GB | |||||||||||
| A100 80GB | |||||||||||
| H100 80 GB | |||||||||||
| MI210 64GB | |||||||||||
Note 1: Supported ambient temperature is 30°C.
Note 2: Bergmano CPUs.
Note 3: Support SKHYNIX RDIMM only
| Configuration | No BP | 8 x 2.5" U.2 | 16 x 2.5" SAS (SmartFlow) | 16 x 2.5" U.2 (SmartFlow) | 24 x 2.5" SAS | 16x2.5" SAS + 8x2.5" U.2 | 8x3.5" | 12x3.5" | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Rear storage | No Rear Drives | No Rear Drives | No Rear Drives | No Rear Drives | No Rear Drives | 2x Rear 2.5" w/ 2x Rear-Fan | 4x Rear 2.5 w/ 3x Rear-Fan | No Rear Drives | No Rear Drives | No Rear Drives | 2x Rear 2.5" w/ 2x Rear-Fan | 4x Rear 2.5 w/ 3x Rear-Fan | ||||
| CPU cTDP Max | Model | Core Count# | ||||||||||||||
| CPU TDP/cTDP | 240 W | 9334 | 32 | 35°C | 35°C | 35°C | ||||||||||
| 9254 | 24 | |||||||||||||||
| 9224 | 24 | |||||||||||||||
| 9124 | 16 | |||||||||||||||
| 300 W | 9634 | 84 | 35°C | 35°C | 30°C | |||||||||||
| 9534 | 64 | |||||||||||||||
| 9454 | 48 | |||||||||||||||
| 9354 | 32 | |||||||||||||||
| 400 W | 9654 | 96 | 35°C | 35°C | Requires LC | |||||||||||
| 9554 | 64 | |||||||||||||||
| 9474F | 48 | |||||||||||||||
| 9374F | 32 | |||||||||||||||
| 9274F | 24 | |||||||||||||||
| 9174F | 16 | |||||||||||||||
| 9734 | 112 | |||||||||||||||
| 9754 | 128 | |||||||||||||||
| 9684X | 96 | |||||||||||||||
| 9384X | 32 | |||||||||||||||
| 9184X | 16 | |||||||||||||||
| Memory | 16 GB RDIMM | 35°C | 35°C | 35°C | ||||||||||||
| 32 GB RDIMM | ||||||||||||||||
| 64 GB RDIMM | ||||||||||||||||
| 96 GB RDIMM | ||||||||||||||||
| 128 GB RDIMM | 35°C | Not Supported | Not Supported | |||||||||||||
| 256 GB RDIMM (Note 1) | 30°C | |||||||||||||||
Note 1: Support SKHYNIX RDIMM only
| Configuration | No BP | 8 x 2.5" U.2 | 16 x 2.5" SAS (SmartFlow) | 16 x 2.5" U.2 (SmartFlow) | 24 x 2.5" SAS | 16x2.5" SAS + 8x2.5" U.2 | 8x3.5" | ||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Rear storage | No Rear Drives | ||||||||||
| CPU cTDP Max | Model | Core Count# | |||||||||
| CPU TDP/cTDP | 240 W | 9334 | 32 | 35°C | 35°C | ||||||
| 9254 | 24 | ||||||||||
| 9224 | 24 | ||||||||||
| 9124 | 16 | ||||||||||
| 300 W | 9634 | 84 | 35°C | ||||||||
| 9534 | 64 | ||||||||||
| 9454 | 48 | ||||||||||
| 9354 | 32 | ||||||||||
| 400 W | 9654 | 96 | 35°C | Not Supported | Requires LC | ||||||
| 9554 | 64 | 30°C | |||||||||
| 9474F | 48 | ||||||||||
| 9374F | 32 | ||||||||||
| 9274F | 24 | 35°C | |||||||||
| 9174F | 16 | ||||||||||
| Memory | 16 GB RDIMM | 35°C | 35°C | ||||||||
| 32 GB RDIMM | |||||||||||
| 64 GB RDIMM | |||||||||||
| 128 GB RDIMM | 35°C | Not Supported | Not Supported | Not Supported | |||||||
| 256 GB RDIMM (Note 1) | 30°C | ||||||||||
| GPU | A2 16 GB | 35°C | 30°C | ||||||||
| A16 64 GB | 35°C | ||||||||||
| A30 24 GB | |||||||||||
| A40 48 GB | |||||||||||
| A100 80 GB | |||||||||||
| H100 80 GB | |||||||||||
| MI210 64 GB | |||||||||||
Note 1: Support SKHYNIX RDIMM only
| Configuration | No BP | 8 x 2.5" U.2 | 24 x 2.5" SAS | 8x3.5" | 12x3.5" | ||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Rear storage | No Rear Drives | No Rear Drives | 2x Rear 2.5" w/ 2x Rear-Fan | 4x Rear 2.5 w/ 3x Rear-Fan | No Rear Drives | No Rear Drives | 2x Rear 2.5" w/ 2x Rear-Fan | 4x Rear 2.5 w/ 3x Rear-Fan | |||
| CPU | All CPU TDP SKUs | HPR SILVER Fan | HPR SILVER Fan [75%] | HPR GOLD Fan [70%] | |||||||
| Memory | 16 GB RDIMM | HPR SILVER Fan | HPR SILVER Fan [75%] | HPR GOLD Fan [70%] | |||||||
| 32 GB RDIMM | |||||||||||
| 64 GB RDIMM | |||||||||||
| 96 GB RDIMM | |||||||||||
| 128 GB RDIMM | HPR GOLD Fan | Not supported | |||||||||
| 256 GB RDIMM (Note 1) | |||||||||||
Note 1: Support SKHYNIX RDIMM only
| Configuration | No BP | 8 x 2.5" U.2 | 8x3.5" | |||
|---|---|---|---|---|---|---|
| Rear storage | No Rear Drives | No Rear Drives | No Rear Drives | |||
| CPU | All CPU TDP SKUs | HPR GOLD Fan | HPR GOLD Fan [75%] | |||
| Memory | 16 GB RDIMM | HPR GOLD Fan | HPR GOLD Fan [75%] | |||
| 32 GB RDIMM | ||||||
| 64 GB RDIMM | ||||||
| 96 GB RDIMM | ||||||
| 128 GB RDIMM | HPR GOLD Fan | Not supported | ||||
| 256 GB RDIMM (Note 2) | ||||||
| GPU | A2 16 GB | HPR GOLD Fan | HPR GOLD Fan [75%] Note 1 | |||
| A16 64 GB | HPR GOLD Fan [75%] | |||||
| A30 24 GB | ||||||
| A40 48 GB | ||||||
| A100 80 GB | ||||||
| H100 80 GB | ||||||
| MI210 64 GB | ||||||
Note 1: Supported ambient temperature is 30°C.
Note 2: Support SKHYNIX RDIMM only
| Label | Description |
|---|---|
| HPR SILVER (Silver) | High performance (silver grade) |
| HPR GOLD (Gold) | High performance (gold grade) |
| HSK | Heat sink |
| LP | Low profile |
| FH | Full height |