Chassis dimensions

| Xa | Xb | Y | Za | Zb | Zc |
|---|---|---|---|---|---|
| 482.0 mm (18.97 inches) | 434.0 mm (17.08 inches) | 86.8 mm (3.41 inches) | 35.84 mm (1.96 inches)With bezel 22.0 mm (0.86 inches) | 700.7 mm (27.58 inches)Ear to rear wall | 736.29 mm (28.98 inches)Ear to PSU handle |
System weight
| System configuration | Maximum weight (with all drives/SSDs) |
|---|---|
| A server with fully populated drives | 34.5 kg (76.05 lb) |
| A server without drives and PSU installed | 25.7 kg (56.65 lb) |
PSU specifications
The PowerEdgeR7615system supports up to two AC or DC power supply units (PSUs).
| PSU | Class | Heat dissipation (maximum) (BTU/hr) | Frequency (Hz) | AC Voltage | DC Voltage | Current (A) | ||||
|---|---|---|---|---|---|---|---|---|---|---|
| 200—240 V | 100—120 V | 277 V | 240 V | - (48—60) V | 336 V | |||||
| 700 W mixed mode | Titanium | 2625 | 50/60 | 700 W | N/A | N/A | N/A | N/A | N/A | 4.1 |
| 2625 | N/A | N/A | N/A | N/A | 700 W | N/A | N/A | 3.4 | ||
| 800 W mixed mode | Platinum | 3000 | 50/60 | 800 W | 800 W | N/A | N/A | N/A | N/A | 9.2—4.7 |
| 3000 | N/A | N/A | N/A | N/A | 800 W | N/A | N/A | 3.8 | ||
| 1100 W mixed mode | Titanium | 4100 | 50/60 | 1100 W | 1050 W | N/A | N/A | N/A | N/A | 12—6.3 |
| 4100 | N/A | N/A | N/A | N/A | 1100 W | N/A | N/A | 5.2 | ||
| 1400 W mixed mode | Platinum | 5250 | 50/60 | 1400 W | 1050 W | N/A | N/A | N/A | N/A | 12—8 |
| 5250 | N/A | N/A | N/A | N/A | 1400 W | N/A | N/A | 6.6 | ||
| Titanium | 5250 | 50/60 | 1400 W | 1050 W | N/A | N/A | N/A | N/A | 12—8 | |
| 5250 | N/A | N/A | N/A | N/A | 1400 W | N/A | N/A | 6.5 | ||
| Titanium | 5250 | 50/60 | 1400 W | 1050 W | 1400 W | N/A | N/A | N/A | 5.8 | |
| 5250 | N/A | N/A | N/A | N/A | 1400 W | N/A | N/A | 5.17 | ||
| 1800 W mixed mode | Titanium | 6750 | 50/60 | 1800 | N/A | N/A | N/A | N/A | N/A | 10 |
| 6750 | N/A | N/A | N/A | N/A | 1800 W | N/A | N/A | 8.2 | ||
| 2400 W mixed mode | Platinum | 9000 | 50/60 | 2400 W | 1400 W | N/A | N/A | N/A | N/A | 16—13.5 |
| 9000 | N/A | N/A | N/A | N/A | 2400 W | N/A | N/A | 11.2 | ||
| 1100 W -48 V DC | N/A | 4265 | N/A | N/A | N/A | N/A | N/A | 1100 W | N/A | 27 |
| 2800 W mixed mode | Titanium | 10500 | 50/60 | 2800 W | N/A | N/A | N/A | N/A | N/A | 15.6 |
| N/A | 10500 | N/A | N/A | N/A | N/A | 2800 W | N/A | N/A | 13.6 | |
- HLAC stands for High-Line AC, with a range of 200 - 240 V AC.
- HVDC stands for High-Voltage DC, with 336 V DC.


| Form factor | Output | Power cable |
|---|---|---|
| Redundant 60 mm | 700 W mixed mode HLAC | C13 |
| 800 W mixed mode | C13 | |
| 1100 W mixed mode | C13 | |
| 1400 W mixed mode | C13 | |
| 1400 W mixed mode 277 Vac and HVDC | APP 2006G1 | |
| 1800 W mixed mode HLAC | C15 | |
| Redundant 86 mm | 2400 W mixed mode | C19 |
Supported operating systemsR7615
The PowerEdge R7615 system supports the following operating systems:
- Canonical Ubuntu Server LTS
- Microsoft Windows Server with Hyper-V
- Red Hat Enterprise Linux
- SUSE Linux Enterprise Server
- VMware ESXi
For more information, go to Operating System Manuals.
Cooling fan specifications
Cooling options
The PowerEdgeR7615 requires various cooling components that based on CPU TDP, storage modules, rear drives, GPU, and persistent memory to maintain optimum thermal performance.
The PowerEdgeR7615 offers two types of cooling options:
- Air cooling
- Processor liquid cooling (optional)
Cooling fan specifications
The PowerEdgeR7615system system supports up to six high-performance silver grade (HPR SLVR) or high-performance gold (HPR Gold) cooling fans.
| Fan type | Abbreviation | Label color | Label image |
|---|---|---|---|
| High performance Silver (HPR) fans | HPR SLVR | Silver | ![]() |
| High performance Gold (HPR Gold) fans | HPR Gold | Gold Grade | ![]() |
System battery specifications
The PowerEdge R7615 system uses one CR 2032 3.0-V lithium coin cell battery.
Expansion card riser specifications
| PCIe slot | With Regular shroud | With GPGPU shroud | R1U | R1T | R2A | R2T | R3A | R3B | R4A | R4P | R4Q | R4S | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Slot 1 | Full height - Half length | Full height - Full length | x8 (Gen5) | - | - | x16 | - | - | - | - | - | - | |
| Slot 2 | Full height - Half length | Full height - Full length | x8 (Gen5) | x16 (Gen5) (Double width GPU) | - | x16 | - | - | - | - | - | - | |
| Slot 3 | Low profile - Half length | Low profile - Half length | - | - | x8 | - | - | - | - | - | - | - | |
| Slot 4 | Full height - Half length | Full height - Half length | - | - | - | - | - | x8 | - | - | - | - | |
| Slot 5 | Full height - Half length | Full height - Full length | - | - | - | - | x16 | x8 | - | - | - | - | |
| Slot 6 | Low profile - Half length | Low profile - Half length | - | - | x8 | - | - | - | - | - | - | - | |
| Slot 7 | Full height - Half length | Full height - Full length | - | - | - | - | - | - | x16 | x16 (Gen5) (Double width GPU) | x8 (Gen5) | x16 (Gen5) | |
| Slot 8 | Full height - Half length | Full height - Half length | - | - | - | - | - | - | - | - | x8 (Gen5) | x16 (Gen5) | |
Memory specifications
| DIMM type | DIMM rank | DIMM capacity | Single processor | |
|---|---|---|---|---|
| Minimum system capacity | Maximum system capacity | |||
| DDR5 RDIMM | Single rank | 16 GB | 16 GB | 196 GB |
| Dual rank | 32 GB | 32 GB | 384 GB | |
| Dual rank | 64 GB | 64 GB | 768 GB | |
| Dual rank | 96 GB | 96 GB | 1152 GB | |
| Quad rank | 128 GB | 128 GB | 1536 GB | |
| Octa rank | 256 GB | 256 GB | 3072 GB | |
| Memory module sockets | Speed |
|---|---|
| 12 (288-pin) | 6400 MT/s |
Storage controller specifications
| Supported storage controller card | |
|---|---|
Software RAID
|
|
Internal controllers
|
|
Internal Boot
|
|
External controllers
|
|
SAS Host Bus Adapters
|
Drives
- 8 x 3.5-inch hot-swappable SAS or SATA drives
- 12 x 3.5-inch hot-swappable SAS or SATA drive
- 8 x 2.5-inch hot-swappable NVMe drives
- 16 x 2.5-inch hot-swappable SAS, SATA, or NVMe drives
- 24 x 2.5-inch hot-swappable SAS or SATA drives
- 32 x EDSFF E3.S hot-swappable NVMe Gen5 drives
- 16 x EDSFF E3.S hot-swappable NVMe Gen5 drives
- 8 x EDSFF E3.S hot-swappable NVMe Gen5 drives
- 2 x 2.5-inch rear hot-swappable SAS, SATA, or NVMe drives
- 4 x 2.5-inch rear hot-swappable SAS, SATA, or NVMe drives
- 4 x EDSFF E3.S rear hot-swappable NVMe Gen5 drives
- Zero drive
USB ports specifications
| Front | Rear | Internal (optional) | |||
|---|---|---|---|---|---|
| USB port type | No. of ports | USB port type | No. of ports | USB port type | No. of ports |
| USB 2.0-compliant port | One | USB 2.0-compliant port | One | Internal USB 3.0-compliant port | One |
| iDRAC Direct port (Micro-AB USB 2.0-compliant port) | One | USB 3.0-compliant port | One | ||
Serial connector specifications
The PowerEdge R7615 system supports one optional card type serial connector, which is a 9-pin connector, Data Terminal Equipment (DTE), 16550-compliant .
The optional serial connector card is installed similar to an expansion card filler bracket.
Environmental specifications
| Temperature | Specifications | |
|---|---|---|
| Allowable continuous operations | ||
| Temperature range for altitudes <= 900 m (<= 2953 ft) | 10–35°C (50–95°F) with no direct sunlight on the equipment | |
| Humidity percent range (non-condensing at all times) | 8% RH with -12°C minimum dew point to 80% RH with 21°C (69.8°F) maximum dew point | |
| Operational altitude de-rating | Maximum temperature is reduced by 1°C/300 m (1.8°F/984 Ft) above 900 m (2953 Ft) | |
| Temperature | Specifications | |
|---|---|---|
| Allowable continuous operations | ||
| Temperature range for altitudes <= 900 m (<= 2953 ft) | 5–40°C (41–104°F) with no direct sunlight on the equipment | |
| Humidity percent range (non-condensing at all times) | 8% RH with -12°C minimum dew point to 85% RH with 24°C (75.2°F) maximum dew point | |
| Operational altitude de-rating | Maximum temperature is reduced by 1°C/175 m (1.8°F/574 Ft) above 900 m (2953 Ft) | |
| Temperature | Specifications | |
|---|---|---|
| Allowable continuous operations | ||
| Temperature range for altitudes <= 900 m (<= 2953 ft) | 5–45°C (41–113°F) with no direct sunlight on the equipment | |
| Humidity percent range (non-condensing at all times) | 8% RH with -12°C minimum dew point to 90% RH with 24°C (75.2°F) maximum dew point | |
| Operational altitude de-rating | Maximum temperature is reduced by 1°C/125 m (1.8°F/410 Ft) above 900 m (2953 Ft) | |
| Temperature | Specifications |
|---|---|
| Allowable continuous operations | |
| Maximum temperature gradient (applies to both operation and non-operation) | 20°C in an hour* (36°F in an hour) and 5°C in 15 minutes (9°F in 15 minutes), 5°C in an hour* (9°F in an hour) for tape hardware
NOTE:* - Per ASHRAE thermal guidelines for tape hardware, these are not instantaneous rates of temperature change.
|
| Non-operational temperature limits | -40 to 65°C (-40 to 149°F) |
| Non-operational humidity limits | 5% to 95% RH with 27°C (80.6°F) maximum dew point |
| Maximum non-operational altitude | 12,000 meters (39,370 feet) |
| Maximum operational altitude | 3,050 meters (10,000 feet) |
| Maximum vibration | Specifications |
|---|---|
| Operating | 0.21 Grms at 5 Hz to 500 Hz for 10 minutes (all operation orientations) |
| Storage | 1.88 Grms at 10 Hz to 500 Hz for 15 minutes (all six sides tested) |
| Maximum shock pulse | Specifications |
|---|---|
| Operating | Six consecutively executed shock pulses in the positive and negative x, y, and z axis of 6 G for up to 11 ms |
| Storage | Six consecutively executed shock pulses in the positive and negative x, y, and z axis (one pulse on each side of the system) of 71 G for up to 2 ms |
Particulate and gaseous contamination specifications
The following table defines the limitations that help avoid any equipment damage or failure from particulates and gaseous contamination. If the levels of particulates or gaseous pollution exceed the specified limitations and result in equipment damage or failure, you may need to rectify the environmental conditions. Remediation of environmental conditions is the responsibility of the customer.| Particulate contamination | Specifications |
|---|---|
| Air filtration | Data center air filtration as defined by ISO Class 8 per ISO 14644-1 with a 95% upper confidence limit
NOTE:This condition applies to data center environments only. Air filtration requirements do not apply to IT equipment designed to be used outside a data center, in environments such as an office or factory floor.
NOTE:Air entering the data center must have MERV11 or MERV13 filtration.
|
| Conductive dust | Air must be free of conductive dust, zinc whiskers, or other conductive particles
NOTE:This condition applies to data center and non-data center environments.
|
| Corrosive dust |
NOTE:This condition applies to data center and non-data center environments.
|
| Walk-Up Edge Data Center or Cabinet (sealed, closed loop environment) | Filtration is not required for cabinets that are anticipated to be opened 6 times or less per year. Class 8 per ISO 1466-1 filtration as defined above is required otherwise
NOTE: In environments commonly above ISA-71 Class G1 or that may have known challenges, special filters may be required.
|
| Gaseous contamination | Specifications |
|---|---|
| Copper coupon corrosion rate | <300 Å/month per Class G1 as defined by ANSI/ISA71.04-2013 |
| Silver coupon corrosion rate | <200 Å/month as defined by ANSI/ISA71.04-2013 |
Particulate and gaseous contamination specifications
The following table defines the limitations that help avoid any equipment damage or failure from particulates and gaseous contamination. If the levels of particulates or gaseous pollution exceed the specified limitations and result in equipment damage or failure, you must rectify the environmental conditions. Remediation of environmental conditions is the responsibility of the customer.
| Particulate contamination | Specifications |
|---|---|
| Air filtration: Conventional Data Center only | Data center air filtration as defined by ISO Class 8 per ISO 14644-1 with a 95% upper confidence limit
NOTE: Filtering room air with a MERV8 filter, as specified in ANSI/ASHRAE Standard 127, is a recommended method for achieving the necessary environmental conditions.
NOTE:Air entering the data center must have MERV11 or MERV13 filtration.
NOTE:This condition applies to data center environments only. Air filtration requirements do not apply to IT equipment designed to be used outside a data center, in environments such as an office or factory floor.
|
| Walk-Up Edge Data Center or Cabinet (sealed, closed loop environment) | Filtration is not required for cabinets that are anticipated to be opened six times or less per year. Class 8 per ISO 1466-1 filtration as defined above is required otherwise.
NOTE: In environments commonly above ISA-71 Class G1 or that may have known challenges, special filters may be required.
|
| Conductive dust: data center and non-data center environments | Air must be free of conductive dust, zinc whiskers, or other conductive particles.
NOTE: Conductive dust, which can interfere with equipment operation, can originate from various sources, including manufacturing processes and zinc whiskers that may develop on the plating of raised floor tiles.
NOTE:This condition applies to data center and non-data center environments.
|
| Corrosive dust: data center and non-data center environments |
NOTE:This condition applies to data center and non-data center environments.
|
| Gaseous contamination | Specifications | Notes |
|---|---|---|
| Copper coupon corrosion rate | ISA-71 Class G1: <300 Å/month | Per ANSI/ISA71.04 |
| Silver coupon corrosion rate | ISA-71 Class G1: <200 Å/month | Per ANSI/ISA71.04 |
Thermal air restrictions
ASHRAE A3 environment for air cooling configuration
- Two PSUs are required in redundant mode. If there is PSU failure, system performance may be reduced.
- Non-Dell qualified peripheral cards and peripheral cards greater than 25 W are not supported.
- GPU and FPGA are not supported.
- 128 GB, and higher capacity RDIMMs are not supported.
- PCIe SSD is not supported.
- Front storage is not supported in 12 x 3.5-inch SAS configuration.
- Rear drives are not supported.
- Processor TDP greater than or equal to 240 W are not supported.
- OCP card is supported with 85°C active optic cable.
- BOSS N1 is supported.
ASHRAE A4 environment for air cooling configuration
- Two PSUs are required in redundant mode. If there is PSU failure, system performance may be reduced.
- Non-Dell qualified peripheral cards and peripheral cards greater than 25 W are not supported.
- GPU and FPGA are not supported.
- 128 GB, and higher capacity RDIMMs are not supported.
- PCIe SSD is not supported.
- Front storage is not supported in 12 x 3.5-inch SAS configuration.
- Rear drives are not supported.
- Processor TDP greater than or equal to 200 W are not supported.
- OCP card is not supported.
- BOSS N1 is not supported.
ASHRAE A3 environment for liquid cooling configuration
- Two PSUs are required in redundant mode. If there is PSU failure, system performance may be reduced.
- Non-Dell qualified peripheral cards and peripheral cards greater than 25 W are not supported.
- GPU and FPGA are not supported.
- Intel Persistent memory 300 series, NVDIMM, 128 GB, or greater capacity DIMMs are not supported.
- PCIeSSD is not supported.
- Rear drives are not supported.
- HPR SLVR fans are required in 2.5-inch configurations systems.
- OCP card is supported with 85°C active optic cable.
- BOSS N1 is supported.
ASHRAE A4 environment for liquid cooling configuration
- Two PSUs are required in redundant mode. If there is PSU failure, system performance may be reduced.
- Non-Dell qualified peripheral cards and peripheral cards greater than 25 W are not supported.
- GPU and FPGA are not supported.
- Intel Persistent memory 300 series, NVDIMM, 128 GB, or greater capacity DIMMs are not supported.
- PCIeSSD is not supported.
- Front storage is not supported in 12 x 3.5-inch SAS configuration.
- Rear drives are not supported.
- HPR SLVR fans are required in 2.5-inch configurations systems.
- OCP card is supported with 85°C active optic cable and cards tier ≤4.
- BOSS N1 is not supported.