Dell PowerEdge R760: руководство по обслуживанию

Chassis dimensions

Figure 1. Chassis dimensions
This image shows chassis dimension for the PowerEge R760 system.
Table 1. PowerEdgeR760 chassis dimensionsThis table provides the dimensions of the system:
Xa Xb Y Za Zb Zc
482.0 mm (18.97 inches)434.0 mm (17.08 inches)86.8 mm (3.41 inches)35.84 mm (1.41 inches)With bezel

22.0 mm (0.86 inches)
  Without bezel

700.7 mm (27.58 inches)Ear to rear wall736.29 mm (28.98 inches)Ear to PSU handle
NOTE:Zb is the nominal rear wall external surface where the system board I/O connectors reside.

System weight

Table 1. PowerEdge R760 system weightThe table below shows the maximum weight of the system.
System configuration Maximum weight (with all drives/SSDs)
A server with fully populated drives 36.1 kg (79.58 lb)
A server without drives and PSU installed 25.1 kg (55.33 lb)

Processor specifications

Table 1. PowerEdge R760 processor specifications This table provides processor specifications for the system.
Supported processor Number of processors supported
4th Gen Intel® Xeon® Scalable or Intel® Xeon® Max Processors or 5th Gen Intel® Xeon® Scalable Processors Up to two
Table 2. Minimum Firmware version requirement for 4th Gen Intel® Xeon® Scalable ProcessorsThe below table describes the supported firmware version based on different processors.
Processors iDRAC BIOS CPLD
8462Y+ 6.10.39.00 1.2.1 1.0.5
6458Q
6448Y
6444Y
6442Y
6438Y+
6438N
6438M
6434
6428N
6426Y
6421N
5420+
5418Y
5418N
5416S
5415+
5412U
5411N
4416+
4410Y
3408U
9480 6.10.80.00 1.3.2 1.0.5
9470
9460
9462
Table 3. Minimum Firmware version requirement for 5th Gen Intel® Xeon® Scalable ProcessorsThe below table describes the supported firmware version based on different processors.
Processors iDRAC BIOS CPLD
5th Gen Intel® Xeon® Scalable Processors 7.10.05.00 2.0.0 N/A

PSU specifications

The PowerEdgeR760system supports up to two AC or DC power supply units (PSUs).

Table 1. PSU specifications This table describes PSU specifications for the system.
PSU Class Heat dissipation (maximum) (BTU/hr) Frequency (Hz) AC Voltage DC Voltage Current (A)
200—240 V 100—120 V 277 V 240 V - (48—60) V 336 V
700 W mixed mode HLAC Titanium 2625 50/60 700 W N/A N/A N/A N/A N/A 4.1
N/A 2625 N/A N/A N/A N/A 700 W N/A N/A 3.4
800 W mixed mode Platinum 3000 50/60 800 W 800 W N/A N/A N/A N/A 9.2—4.7
N/A 3000 N/A N/A N/A N/A 800 W N/A N/A 3.8
1100 W mixed mode Titanium 4100 50/60 1100 W 1050 W N/A N/A N/A N/A 12—6.3
N/A 4100 N/A N/A N/A N/A 1100 W N/A N/A 5.2
1400 W mixed mode Platinum 5250 50/60 1400 W 1050 W N/A N/A N/A N/A 12—8
N/A 5250 N/A N/A N/A N/A 1400 W N/A N/A 6.6
1400 W mixed mode Titanium 5250 50/60 1400 W 1050 WN/A N/A N/A N/A 12—8
N/A 5250 N/A N/A N/A N/A 1400 W N/A N/A 6.5
1400 W mixed mode 277 Vac and HVDC Titanium 5250 50/60 N/A N/A 1400 W N/A N/A N/A 5.8
5250 N/A N/A N/A N/A N/A N/A 1400 W 5.17
1800 W mixed mode HLAC Titanium 6750 50/60 1800 N/A N/A N/A N/A N/A 10
N/A 6750 N/A N/A N/A N/A 1800 W N/A N/A 8.2
2400 W mixed mode Platinum 9000 50/60 2400 W 1400 W N/A N/A N/A N/A 16—13.5
N/A 9000 N/A N/A N/A N/A 2400 W N/A N/A 11.2
2800 W mixed mode HLAC Titanium 10500 50/60 2800 W N/A N/A N/A N/A N/A 15.6
N/A 10500 N/A N/A N/A N/A 2800 W N/A N/A 13.6
1100 W -48 V DC N/A 4265 N/A N/A N/A N/A N/A 1100 W N/A 27
3200 W mixed mode 277 Vac and HVDC Titanium 12000 50/60 N/A N/A 3200 W N/A N/A N/A 13
12000 N/A N/A N/A N/A N/A N/A 3200 W 11.5
NOTE:Heat dissipation is calculated using the PSU wattage rating.
NOTE:When selecting or upgrading the system configuration, to ensure optimum power utilization, verify the system power consumption with the Enterprise Infrastructure Planning Tool available at calc.
NOTE:If a system with AC 2400 W PSUs operates at low line 100-120 Vac, then the power rating per PSU is degraded to 1400 W.
NOTE:If a system with AC 1400 W or 1100 W PSUs operates at low line 100-120 Vac, then the power rating per PSU is degraded to 1050 W.
NOTE:
  • HLAC stands for High-Line AC, with a range of 200 - 240 V AC.
  • HVDC stands for High-Voltage DC, with 336 V DC.
Figure 1. PSU power cables
this image shows list of PSU power cords
Figure 2. 277VAC/HVDC power cable

this image shows list of PSU power cord

Table 2. PSU power cablesThe table lists the PSU power cables list .
Form factor Output Power cable
Redundant 60 mm 700 W mixed mode HLAC C13
800 W mixed mode C13
1100 W mixed mode C13
1400 W mixed mode C13
1400 W mixed mode 277 Vac and HVDC 277VAC/HVDC
1800 W mixed mode HLAC C15
Redundant 86 mm 2400 W mixed mode C19
2800 W mixed mode HLAC C21
3200 W mixed mode 277 Vac and HVDC 277VAC/HVDC
NOTE:C19 power cable combined with C20 to C21 jumper power cable can be used to adapt 2800 W PSU.
NOTE:C13 power cable combined with C14 to C15 jumper power cable can be used to adapt 1800 W PSU.

Supported operating systemsR760

The PowerEdge R760 system supports the following operating systems:

  • Canonical Ubuntu Server LTS
  • Microsoft Windows Server with Hyper-V
  • Red Hat Enterprise Linux
  • SUSE Linux Enterprise Server
  • VMware ESXi
NOTE:Intel Xeon® 6300 series CPUs do not support Windows Server 2019.

For more information, go to Operating System Manuals.

Cooling fan specifications

Cooling options

The PowerEdgeR760 requires various cooling components that are based on processor TDP, storage modules, rear drives, and GPU to maintain optimum thermal performance.

The PowerEdgeR760 offers two types of cooling options:

  • Air cooling
  • Direct Liquid Cooling (DLC) (optional)

Cooling fan specifications

The PowerEdgeR760system system supports up to six standard (STD), High performance Silver (HPR Silver) grade , or High performance Gold (HPR Gold) grade cooling fans.

Table 1. Cooling fan specificationsCooling fan specifications
Fan type Abbreviation Label color Label image
Standard (STD) fans STD No labelThis shows the Standard fan image.
High performance Silver (HPR Silver) fans HPR Silver SilverThis shows the High Performance Silver (HPR) fan
High performance Gold (HPR Gold) fansHPR Gold GoldThis shows the High Performance Gold (VHP) fan
NOTE:See the Thermal restriction matrix for required fan support with air cooled and DLC configurations.

System battery specifications

The PowerEdge R760 system uses one CR 2032 3.0 V lithium coin cell battery.

Expansion card riser specifications

The PowerEdge R760 system supports up to eight PCI express (PCIe) slots (six full lengths and two low profiles) on the system board.
Table 1. Expansion card slots supported on the system boardThis table provides information about the expansion card slots that are supported on the PowerEdge R760 system.
PCIe slot With Regular shroud With GPGPU shroud R1B R1P R1Q R1R R2A R3A R3B R4B R4P R4Q R4R
Slot 1 Full height - Half length Full height - Full length x8 - x8 (Gen5) x16 - - - - - - -
Slot 2 Full height - Half length Full height - Full length x8 x16 (Gen5) (Double width GPU) x8 (Gen5) x16 (Gen5) - - - - - - -
Slot 3 Low profile - Half length Low profile - Half length - - - - x16 - - - - - -
Slot 4 Full height - Half length Full height - Half length - - - - - - x8 - - - -
Slot 5 Full height - Half length Full height - Full length - - - - - x16 x8 - - - -
Slot 6 Low profile - Half length Low profile - Half length - - - - x16 - - - - - -
Slot 7 Full height - Half length Full height - Full length - - - - - - - x8 x16 (Gen5) (Double width GPU) x8 (Gen5) -
Slot 7 SNAPI Full height- Half length Full height - Full length - - - - - - - - - - x8+x8 (Gen5)
Slot 8 Full height - Half length Full height - Half length - - - - - - - x8 - x8 (Gen5) x8 (Gen5)

Memory specifications

The PowerEdge R760 system supports the following memory specifications for optimized operation.
Table 1. Memory specifications for 4th Gen Intel® Xeon® Scalable or Intel® Xeon® Max ProcessorsThe table below shows the memory specifications:
DIMM type DIMM rank DIMM capacity Single processor Dual processors
Minimum system capacity Maximum system capacity Minimum system capacity Maximum system capacity
DDR5 RDIMM Single rank 16 GB 16 GB 256 GB 32 GB 512 GB
Dual rank 32 GB 32 GB 512 GB 64 GB 1 TB
Dual rank 64 GB 64 GB 1 TB 128 GB 2 TB
Quad rank 128 GB 128 GB 2 TB 256 GB 4 TB
Octa rank 256 GB 256 GB 4 TB 512 GB 8 TB
Table 2. Memory module socketsThe table below shows the memory module sockets for the system:
Memory module sockets Rated DIMM speed
32 (288-pin) 4800 MT/s
NOTE:The processor may reduce the performance of the rated DIMM speed.
Table 3. Memory specifications for 5th Gen Intel® Xeon® Scalable ProcessorsThe table below shows the memory specifications:
DIMM type DIMM rank DIMM capacity Single processor Dual processors
Minimum system capacity Maximum system capacity Minimum system capacity Maximum system capacity
DDR5 RDIMM Single rank 16 GB 16 GB 256 GB 32 GB 512 GB
Dual rank 32 GB 32 GB 512 GB 64 GB 1 TB
Dual rank 64 GB 64 GB 1 TB 128 GB 2 TB
Dual rank 96 GB 96 GB 1.5 TB 192 GB 3 TB
Quad rank 128 GB 128 GB 2 TB 256 GB 4 TB
Octa rank 256 GB 256 GB 4 TB 512 GB 8 TB
NOTE: DDR4 memories are not supported in the R760.
Table 4. Memory module socketsThe table below shows the memory module sockets for the system:
Memory module sockets Rated DIMM speed
32 (288-pin) 6400 MT/s, or 5600 MT/s
NOTE:The processor may reduce the performance of the rated DIMM speed.
NOTE:6400/5600 MT/s RDIMMs are applicable for 5th Gen Intel® Xeon® Scalable Processors..
NOTE:Memory DIMM slots are not hot pluggable.
NOTE: Quad rank (4R) 128 GB has reached EOL.

Storage controller specifications

The PowerEdge R760 system supports the following controller cards:
Table 1. Storage controller cards This table provides the controller cards that are supported on the system:
Supported storage controller cards
Internal controllers
  • PERC H965i
  • PERC H755
  • PERC H755N
  • PERC H355
External controllers
  • PERC H965e
Internal Boot
  • Boot Optimized Storage Subsystem (BOSS-N1): HWRAID 2 x M.2 NVMe SSD
  • USB
Software RAID
  • S160
SAS Host Bus Adapters (HBA) non-RAID
  • HBA355e
  • HBA355i
  • HBA465i

Drives

The PowerEdge R760 system supports:
  • 12 x 3.5-inch hot-swappable SAS or SATA drives
  • 8 x 2.5-inch hot-swappable SAS, SATA, or NVMe drives
  • 16 x 2.5-inch hot-swappable SAS, SATA, or NVMe drives
  • 24 x 2.5-inch hot-swappable SAS or SATA, or NVMe drives
  • 16 x EDSFF E3.S hot-swappable NVMe drives
  • 2 x 2.5-inch rear hot-swappable SAS, SATA, or NVMe drives
  • 4 x 2.5-inch rear hot-swappable SAS, SATA, or NVMe drives
  • 4 x EDSFF E3.S rear hot-swappable NVMe drives
NOTE: For more information about how to hot swap NVMe PCIe SSD U.2 device, see the Dell Express Flash NVMe PCIe SSD User's Guide at Dell Support > Browse all products > Infrastructure > Data Center Infrastructure >  Storage Adapters & Controllers > Dell PowerEdge Express Flash NVMe PCIe SSD > Select This Product > Documentation > Manuals and Documents.

USB ports specifications

Table 1. PowerEdge R760 USB specificationsThe following table shows the USB specifications for the system:
Front Rear Internal (optional)
USB port type No. of ports USB port type No. of ports USB port type No. of ports
USB 2.0-compliant port One USB 2.0-compliant port One Internal USB 3.0-compliant port One
iDRAC Direct port (Micro-AB USB 2.0-compliant port) One USB 3.0-compliant port One
NOTE:The micro USB 2.0 compliant port can only be used as an iDRAC Direct or a management port.

NIC port specifications

The PowerEdge R760 system supports up to two Network Interface Controller (NIC) ports embedded on the LAN on Motherboard (LOM) card and up to four ports integrated on the Open Compute Project (OCP) NIC card.
Table 1. NIC port specification for the systemThis table describes the NIC port specification for the system.
Feature Specifications
LOM card (optional) 1 GbE x 2
OCP NIC card (OCP NIC 3.0) (optional) 1GbE x 4, 10 GbE x 2, 10 GbE x 4, 25 GbE x 2, 25 GbE x 4, 100GbE x 2
Management Interface Card (MIC) to support Dell Data Processing Unit (DPU) card (optional) 25 GbE x 2, 100 GbE x 2 or 200 GbE x 2
NOTE:The system allows either LOM card or an OCP NIC card or both to be installed in the system.
NOTE:On the MS system board, the supported OCP NIC PCIe width is x8; when x16 PCIe width is installed, it is downgraded to x8.
NOTE:A 100 GbE OCP NIC card of PCIe width x16 can be used by connecting the OCP NIC cable from SL11_CPU1_PB7 to SL13_CPU1_PB7 on the MAX system board.
NOTE:For storage configurations that already use the SL11_CPU1_PB7 or SL13_CPU1_PB7 connector on the Max system board, there is a restriction on supporting OCP NIC cable.
NOTE:The system allows either LOM card or MIC card to be installed in the system.

Serial connector specifications

The PowerEdge R760 system supports one serial port on the system board, which is Data Terminal Equipment (DTE), 16550-compliant.

The optional serial connector card is installed similar to an expansion card filler bracket.

VGA ports specifications

The PowerEdge R760 system supports DB-15 VGA port on front panel and on rear I/O board (optional for Direct Liquid Cooling configuration).

Video specifications

The PowerEdge R760 system supports integrated Matrox G200 graphics controller with 16 MB of video frame buffer.
Table 1. Supported video resolution options This table describes the supported front video resolution options for the system.
Resolution Refresh rate (Hz) Color depth (bits)
1024 x 768 60 8, 16, 32
1280 x 800 60 8, 16, 32
1280 x 1024 60 8, 16, 32
1360 x 768 60 8, 16, 32
1440 x 900 60 8, 16, 32
1600 x 900 60 8, 16, 32
1600 x 1200 60 8, 16, 32
1680 x 1050 60 8, 16, 32
1920 x 1080 60 8, 16, 32
1920 x 1200 60 8, 16, 32

Environmental specifications

NOTE:For additional information about environmental certifications, refer to the Product Environmental Datasheet located with the Documentation on Dell Support.
Table 1. Continuous Operation Specifications for ASHRAE A2 This table describes the operational climatic range for category A2.
Temperature Specifications
Allowable continuous operations
Temperature range for altitudes <= 900 m (<= 2953 ft) 10–35°C (50–95°F) with no direct sunlight on the equipment
Humidity percent range (non-condensing at all times) 8% RH with -12°C (10.4°F) minimum dew point to 80% RH with 21°C (69.8°F) maximum dew point
Operational altitude de-rating Maximum temperature is reduced by 1°C/300 m (1.8°F/984 Ft) above 900 m (2953 Ft)
Table 2. Continuous Operation Specifications for ASHRAE A3 This table describes the operational climatic range for category A3.
Temperature Specifications
Allowable continuous operations
Temperature range for altitudes <= 900 m (<= 2953 ft) 5–40°C (41–104°F) with no direct sunlight on the equipment
Excursion Limited Operation 5-35°C (41-95°F) Continuous Operation
35-40°C (95-104°F) 10% Annual Runtime
Humidity percent range (non-condensing at all times) 8% RH with -12°C (10.4°F) minimum dew point to 85% RH with 24°C (75.2°F) maximum dew point
Operational altitude de-rating Maximum temperature is reduced by 1°C/175 m (1.8°F/574 Ft) above 900 m (2953 Ft)
Table 3. Continuous Operation Specifications for ASHRAE A4 This table describes the operational climatic range for category A4.
Temperature Specifications
Allowable continuous operations
Temperature range for altitudes <= 900 m (<= 2953 ft) 5–45°C (41–113°F) with no direct sunlight on the equipment
Excursion Limited Operation 5-35°C (41-95°F) Continuous Operation
35-40°C (95-104°F) 10% Annual Runtime
40-45°C (104-113°F) 1% Annual Runtime
Humidity percent range (non-condensing at all times) 8% RH with -12°C (10.4°F) minimum dew point to 90% RH with 24°C (75.2°F) maximum dew point
Operational altitude de-rating Maximum temperature is reduced by 1°C/125 m (1.8°F/410 Ft) above 900 m (2953 Ft)
Table 4. Common Environmental Specifications for ASHRAE A2, A3 and A4 This table describes the shared requirements across all categories.
Temperature Specifications
Allowable continuous operations
Maximum temperature gradient (applies to both operation and non-operation) 20°C in an hour* (36°F in an hour) and 5°C in 15 minutes (9°F in 15 minutes), 5°C in an hour* (9°F in an hour) for tape hardware
NOTE:* - Per ASHRAE thermal guidelines for tape hardware, these are not instantaneous rates of temperature change.
Non-operational temperature limits -40 to 65°C (-40 to 149°F)
Non-operational humidity limits 5% to 95% RH with 27°C (80.6°F) maximum dew point
Maximum non-operational altitude 12,000 meters (39,370 feet)
Maximum operational altitude 3,050 meters (10,006 feet)
Table 5. Maximum vibration specificationsThe maximum vibration specification of an operational system is 0.26 Grms at 5 Hz to 350 Hz (all operation orientations).The maximum vibration specification of a nonoperational system is 1.88 Grms at 10 Hz to 500 Hz for 15 minutes (all six sides tested).
Maximum vibration Specifications
Operating 0.21 Grms at 5 Hz to 500 Hz for 10 minutes (all operation orientations)
Storage 1.88 Grms at 10 Hz to 500 Hz for 15 minutes (all six sides tested)
Table 6. Maximum shock pulse specificationsThe maximum shock specification of an operational system is six consecutively executed shock pulses in the positive and negative x, y, and z axis of 40 G for up to 2.3 ms. The maximum shock specification of a nonoperational system is six consecutively executed shock pulses in the positive and negative x, y, and z axis (one pulse on each side of the system) of 71 G for up to 2 ms.
Maximum shock pulse Specifications
Operating Six consecutively executed shock pulses in the positive and negative x, y, and z axis of 6 G for up to 11 ms
Storage Six consecutively executed shock pulses in the positive and negative x, y, and z axis (one pulse on each side of the system) of 71 G for up to 2 ms

Particulate and gaseous contamination specifications

The following table defines the limitations that help avoid any equipment damage or failure from particulates and gaseous contamination. If the levels of particulates or gaseous pollution exceed the specified limitations and result in equipment damage or failure, you may need to rectify the environmental conditions. Remediation of environmental conditions is the responsibility of the customer.
Table 7. Particulate contamination specificationsAir filtration specification: Data center air filtration as defined by ISO Class 8 per ISO 14644-1 shpuld have a 95% upper confidence limit. Note: This condition applies only to data center environments. Air filtration requirements do not apply to IT equipment designed to be used outside a data center, in environments such as an office or factory floor. Note: Air entering the data center must have MERV11 or MERV13 filtration. Conductive dust specification: Air must be free of conductive dust, zinc whiskers, or other conductive particles. Note: This condition applies to data center and non-data center environments. Corrosive dust specification: Air must be free of corrosive dust. Residual dust present in the air must have a deliquescent point less than 60% relative humidity. Note: This condition applies to data center and non-data center environments.
Particulate contamination Specifications
Air filtration Data center air filtration as defined by ISO Class 8 per ISO 14644-1 with a 95% upper confidence limit
NOTE:This condition applies to data center environments only. Air filtration requirements do not apply to IT equipment designed to be used outside a data center, in environments such as an office or factory floor.
NOTE:Air entering the data center must have MERV11 or MERV13 filtration.
Conductive dust Air must be free of conductive dust, zinc whiskers, or other conductive particles
NOTE:This condition applies to data center and non-data center environments.
Corrosive dust
  • Air must be free of corrosive dust
  • Residual dust present in the air must have a deliquescent point less than 60% relative humidity
NOTE:This condition applies to data center and non-data center environments.
Walk-Up Edge Data Center or Cabinet (sealed, closed loop environment) Filtration is not required for cabinets that are anticipated to be opened 6 times or less per year. Class 8 per ISO 1466-1 filtration as defined above is required otherwise
NOTE: In environments commonly above ISA-71 Class G1 or that may have known challenges, special filters may be required.
Table 8. Gaseous contamination specificationsThe copper coupon corrosion rate is <300 Å/month per Class G1 as defined by ANSI/ISA71.04-2013. The silver coupon corrosion rate is <200 Å/month as defined by ANSI/ISA71.04-2013.
Gaseous contamination Specifications
Copper coupon corrosion rate <300 Å/month per Class G1 as defined by ANSI/ISA71.04-2013
Silver coupon corrosion rate <200 Å/month as defined by ANSI/ISA71.04-2013

Particulate and gaseous contamination specifications

The following table defines the limitations that help avoid any equipment damage or failure from particulates and gaseous contamination. If the levels of particulates or gaseous pollution exceed the specified limitations and result in equipment damage or failure, you must rectify the environmental conditions. Remediation of environmental conditions is the responsibility of the customer.

Table 1. Particulate contamination specificationsAir filtration specification: Data center air filtration as defined by ISO Class 8 per ISO 14644-1 should have a 95% upper confidence limit. Note: This condition applies only to data center environments. Air filtration requirements do not apply to IT equipment designed to be used outside a data center, in environments such as an office or factory floor. Note: Air entering the data center must have MERV11 or MERV13 filtration. Conductive dust specification: Air must be free of conductive dust, zinc whiskers, or other conductive particles. Note: This condition applies to data center and non-data center environments. Corrosive dust specification: Air must be free of corrosive dust. Residual dust present in the air must have a deliquescent point less than 60% relative humidity. Note: This condition applies to data center and non-data center environments.
Particulate contamination Specifications
Air filtration: Conventional Data Center only Data center air filtration as defined by ISO Class 8 per ISO 14644-1 with a 95% upper confidence limit
NOTE: Filtering room air with a MERV8 filter, as specified in ANSI/ASHRAE Standard 127, is a recommended method for achieving the necessary environmental conditions.
NOTE:Air entering the data center must have MERV11 or MERV13 filtration.
NOTE:This condition applies to data center environments only. Air filtration requirements do not apply to IT equipment designed to be used outside a data center, in environments such as an office or factory floor.
Walk-Up Edge Data Center or Cabinet (sealed, closed loop environment) Filtration is not required for cabinets that are anticipated to be opened six times or less per year. Class 8 per ISO 1466-1 filtration as defined above is required otherwise.
NOTE: In environments commonly above ISA-71 Class G1 or that may have known challenges, special filters may be required.
Conductive dust: data center and non-data center environments Air must be free of conductive dust, zinc whiskers, or other conductive particles.
NOTE: Conductive dust, which can interfere with equipment operation, can originate from various sources, including manufacturing processes and zinc whiskers that may develop on the plating of raised floor tiles.
NOTE:This condition applies to data center and non-data center environments.
Corrosive dust: data center and non-data center environments
  • Air must be free of corrosive dust.
  • Residual dust present in the air must have a deliquescent point less than 60% relative humidity.
NOTE:This condition applies to data center and non-data center environments.
Table 2. Gaseous contamination specificationsThe copper coupon corrosion rate is <300 Å/month per Class G1 as defined by ANSI/ISA71.04. The silver coupon corrosion rate is <200 Å/month as defined by ANSI/ISA71.04.
Gaseous contamination Specifications Notes
Copper coupon corrosion rate ISA-71 Class G1: <300 Å/month Per ANSI/ISA71.04
Silver coupon corrosion rate ISA-71 Class G1: <200 Å/month Per ANSI/ISA71.04

Thermal air restrictions

Table 1. Air cooling configurations thermal restriction for AHSRAE A3 and A4This table provides information about ASHRAE A3 and A4 restrictions for air cooling configuration.
ASHRAE A3/40°C (104°F) A4/45°C (113°F)
PSU Two PSUs are required in redundant mode. If there is PSU failure, system performance may be reduced.
PCIe card Non-Dell qualified peripheral cards and peripheral cards greater than 25 W are not supported.
GPU/FPGA Not supported
DIMM 128 GB, or greater capacity DIMMs are not supported.
PCIe SSD Not supported
Front storage Not supported in 12 x 3.5-inch SAS configuration.
Rear storage Not supported
Fan HPR SLVR fans are required.
Processor ≤ 165 W ≤ 125 W
OCP Supported with 85°C (185°F) active optic cable. Supported with 85°C (185°F) active optic cable and cards tier ≤4.
BOSS BOSS-N1 is supported. BOS-N1 is not supported.
Table 2. Liquid cooling configurations thermal restriction for AHSRAE A3 and A4This table provides information about ASHRAE A3 and A4 restrictions for air cooling configuration.
ASHRAE A3/40°C (104°F) A4/45°C (113°F)
PSU Two PSUs are required in redundant mode. If there is PSU failure, system performance may be reduced.
PCIe card Non-Dell qualified peripheral cards and peripheral cards greater than 25 W are not supported.
GPU/FPGA Not supported
DIMM 128 GB, or greater capacity DIMMs are not supported.
PCIe SSD Not supported
Front storage Not supported in 12 x 3.5-inch SAS configuration.
Rear storage Not supported
Fan HPR SLVR fans are required in 2.5-inch configurations systems.
OCP Supported with 85°C (185°F) active optic cable. Supported with 85°C (185°F) active optic cable and cards tier ≤4.
BOSS BOSS-N1 is supported. BOSS-N1 is not supported.