Chassis dimensions

| Xa | Xb | Y | Za | Zb | Zc |
|---|---|---|---|---|---|
| 482.0 mm (18.97 inches) | 434.0 mm (17.08 inches) | 86.8 mm (3.41 inches) | 35.84 mm (1.41 inches)With bezel 22.0 mm (0.86 inches) | 700.7 mm (27.58 inches)Ear to rear wall | 736.29 mm (28.98 inches)Ear to PSU handle |
System weight
| System configuration | Maximum weight (with all drives/SSDs) |
|---|---|
| A server with fully populated drives | 36.1 kg (79.58 lb) |
| A server without drives and PSU installed | 25.1 kg (55.33 lb) |
Processor specifications
| Supported processor | Number of processors supported |
|---|---|
| 4th Gen Intel® Xeon® Scalable or Intel® Xeon® Max Processors or 5th Gen Intel® Xeon® Scalable Processors | Up to two |
| Processors | iDRAC | BIOS | CPLD |
|---|---|---|---|
| 8462Y+ | 6.10.39.00 | 1.2.1 | 1.0.5 |
| 6458Q | |||
| 6448Y | |||
| 6444Y | |||
| 6442Y | |||
| 6438Y+ | |||
| 6438N | |||
| 6438M | |||
| 6434 | |||
| 6428N | |||
| 6426Y | |||
| 6421N | |||
| 5420+ | |||
| 5418Y | |||
| 5418N | |||
| 5416S | |||
| 5415+ | |||
| 5412U | |||
| 5411N | |||
| 4416+ | |||
| 4410Y | |||
| 3408U | |||
| 9480 | 6.10.80.00 | 1.3.2 | 1.0.5 |
| 9470 | |||
| 9460 | |||
| 9462 |
| Processors | iDRAC | BIOS | CPLD |
|---|---|---|---|
| 5th Gen Intel® Xeon® Scalable Processors | 7.10.05.00 | 2.0.0 | N/A |
PSU specifications
The PowerEdgeR760system supports up to two AC or DC power supply units (PSUs).
| PSU | Class | Heat dissipation (maximum) (BTU/hr) | Frequency (Hz) | AC Voltage | DC Voltage | Current (A) | ||||
|---|---|---|---|---|---|---|---|---|---|---|
| 200—240 V | 100—120 V | 277 V | 240 V | - (48—60) V | 336 V | |||||
| 700 W mixed mode HLAC | Titanium | 2625 | 50/60 | 700 W | N/A | N/A | N/A | N/A | N/A | 4.1 |
| N/A | 2625 | N/A | N/A | N/A | N/A | 700 W | N/A | N/A | 3.4 | |
| 800 W mixed mode | Platinum | 3000 | 50/60 | 800 W | 800 W | N/A | N/A | N/A | N/A | 9.2—4.7 |
| N/A | 3000 | N/A | N/A | N/A | N/A | 800 W | N/A | N/A | 3.8 | |
| 1100 W mixed mode | Titanium | 4100 | 50/60 | 1100 W | 1050 W | N/A | N/A | N/A | N/A | 12—6.3 |
| N/A | 4100 | N/A | N/A | N/A | N/A | 1100 W | N/A | N/A | 5.2 | |
| 1400 W mixed mode | Platinum | 5250 | 50/60 | 1400 W | 1050 W | N/A | N/A | N/A | N/A | 12—8 |
| N/A | 5250 | N/A | N/A | N/A | N/A | 1400 W | N/A | N/A | 6.6 | |
| 1400 W mixed mode | Titanium | 5250 | 50/60 | 1400 W | 1050 W | N/A | N/A | N/A | N/A | 12—8 |
| N/A | 5250 | N/A | N/A | N/A | N/A | 1400 W | N/A | N/A | 6.5 | |
| 1400 W mixed mode 277 Vac and HVDC | Titanium | 5250 | 50/60 | N/A | N/A | 1400 W | N/A | N/A | N/A | 5.8 |
| 5250 | N/A | N/A | N/A | N/A | N/A | N/A | 1400 W | 5.17 | ||
| 1800 W mixed mode HLAC | Titanium | 6750 | 50/60 | 1800 | N/A | N/A | N/A | N/A | N/A | 10 |
| N/A | 6750 | N/A | N/A | N/A | N/A | 1800 W | N/A | N/A | 8.2 | |
| 2400 W mixed mode | Platinum | 9000 | 50/60 | 2400 W | 1400 W | N/A | N/A | N/A | N/A | 16—13.5 |
| N/A | 9000 | N/A | N/A | N/A | N/A | 2400 W | N/A | N/A | 11.2 | |
| 2800 W mixed mode HLAC | Titanium | 10500 | 50/60 | 2800 W | N/A | N/A | N/A | N/A | N/A | 15.6 |
| N/A | 10500 | N/A | N/A | N/A | N/A | 2800 W | N/A | N/A | 13.6 | |
| 1100 W -48 V DC | N/A | 4265 | N/A | N/A | N/A | N/A | N/A | 1100 W | N/A | 27 |
| 3200 W mixed mode 277 Vac and HVDC | Titanium | 12000 | 50/60 | N/A | N/A | 3200 W | N/A | N/A | N/A | 13 |
| 12000 | N/A | N/A | N/A | N/A | N/A | N/A | 3200 W | 11.5 | ||
- HLAC stands for High-Line AC, with a range of 200 - 240 V AC.
- HVDC stands for High-Voltage DC, with 336 V DC.


| Form factor | Output | Power cable |
|---|---|---|
| Redundant 60 mm | 700 W mixed mode HLAC | C13 |
| 800 W mixed mode | C13 | |
| 1100 W mixed mode | C13 | |
| 1400 W mixed mode | C13 | |
| 1400 W mixed mode 277 Vac and HVDC | 277VAC/HVDC | |
| 1800 W mixed mode HLAC | C15 | |
| Redundant 86 mm | 2400 W mixed mode | C19 |
| 2800 W mixed mode HLAC | C21 | |
| 3200 W mixed mode 277 Vac and HVDC | 277VAC/HVDC |
Supported operating systemsR760
The PowerEdge R760 system supports the following operating systems:
- Canonical Ubuntu Server LTS
- Microsoft Windows Server with Hyper-V
- Red Hat Enterprise Linux
- SUSE Linux Enterprise Server
- VMware ESXi
For more information, go to Operating System Manuals.
Cooling fan specifications
Cooling options
The PowerEdgeR760 requires various cooling components that are based on processor TDP, storage modules, rear drives, and GPU to maintain optimum thermal performance.
The PowerEdgeR760 offers two types of cooling options:
- Air cooling
- Direct Liquid Cooling (DLC) (optional)
Cooling fan specifications
The PowerEdgeR760system system supports up to six standard (STD), High performance Silver (HPR Silver) grade , or High performance Gold (HPR Gold) grade cooling fans.
| Fan type | Abbreviation | Label color | Label image |
|---|---|---|---|
| Standard (STD) fans | STD | No label | ![]() |
| High performance Silver (HPR Silver) fans | HPR Silver | Silver | ![]() |
| High performance Gold (HPR Gold) fans | HPR Gold | Gold | ![]() |
System battery specifications
The PowerEdge R760 system uses one CR 2032 3.0 V lithium coin cell battery.
Expansion card riser specifications
| PCIe slot | With Regular shroud | With GPGPU shroud | R1B | R1P | R1Q | R1R | R2A | R3A | R3B | R4B | R4P | R4Q | R4R | ||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Slot 1 | Full height - Half length | Full height - Full length | x8 | - | x8 (Gen5) | x16 | - | - | - | - | - | - | - | ||
| Slot 2 | Full height - Half length | Full height - Full length | x8 | x16 (Gen5) (Double width GPU) | x8 (Gen5) | x16 (Gen5) | - | - | - | - | - | - | - | ||
| Slot 3 | Low profile - Half length | Low profile - Half length | - | - | - | - | x16 | - | - | - | - | - | - | ||
| Slot 4 | Full height - Half length | Full height - Half length | - | - | - | - | - | - | x8 | - | - | - | - | ||
| Slot 5 | Full height - Half length | Full height - Full length | - | - | - | - | - | x16 | x8 | - | - | - | - | ||
| Slot 6 | Low profile - Half length | Low profile - Half length | - | - | - | - | x16 | - | - | - | - | - | - | ||
| Slot 7 | Full height - Half length | Full height - Full length | - | - | - | - | - | - | - | x8 | x16 (Gen5) (Double width GPU) | x8 (Gen5) | - | ||
| Slot 7 SNAPI | Full height- Half length | Full height - Full length | - | - | - | - | - | - | - | - | - | - | x8+x8 (Gen5) | ||
| Slot 8 | Full height - Half length | Full height - Half length | - | - | - | - | - | - | - | x8 | - | x8 (Gen5) | x8 (Gen5) | ||
Memory specifications
| DIMM type | DIMM rank | DIMM capacity | Single processor | Dual processors | ||
|---|---|---|---|---|---|---|
| Minimum system capacity | Maximum system capacity | Minimum system capacity | Maximum system capacity | |||
| DDR5 RDIMM | Single rank | 16 GB | 16 GB | 256 GB | 32 GB | 512 GB |
| Dual rank | 32 GB | 32 GB | 512 GB | 64 GB | 1 TB | |
| Dual rank | 64 GB | 64 GB | 1 TB | 128 GB | 2 TB | |
| Quad rank | 128 GB | 128 GB | 2 TB | 256 GB | 4 TB | |
| Octa rank | 256 GB | 256 GB | 4 TB | 512 GB | 8 TB | |
| Memory module sockets | Rated DIMM speed |
|---|---|
| 32 (288-pin) | 4800 MT/s |
| DIMM type | DIMM rank | DIMM capacity | Single processor | Dual processors | ||
|---|---|---|---|---|---|---|
| Minimum system capacity | Maximum system capacity | Minimum system capacity | Maximum system capacity | |||
| DDR5 RDIMM | Single rank | 16 GB | 16 GB | 256 GB | 32 GB | 512 GB |
| Dual rank | 32 GB | 32 GB | 512 GB | 64 GB | 1 TB | |
| Dual rank | 64 GB | 64 GB | 1 TB | 128 GB | 2 TB | |
| Dual rank | 96 GB | 96 GB | 1.5 TB | 192 GB | 3 TB | |
| Quad rank | 128 GB | 128 GB | 2 TB | 256 GB | 4 TB | |
| Octa rank | 256 GB | 256 GB | 4 TB | 512 GB | 8 TB | |
| Memory module sockets | Rated DIMM speed |
|---|---|
| 32 (288-pin) | 6400 MT/s, or 5600 MT/s |
Storage controller specifications
| Supported storage controller cards | |
|---|---|
Internal controllers
|
|
External controllers
|
|
Internal Boot
|
|
Software RAID
|
|
SAS Host Bus Adapters (HBA) non-RAID
|
Drives
- 12 x 3.5-inch hot-swappable SAS or SATA drives
- 8 x 2.5-inch hot-swappable SAS, SATA, or NVMe drives
- 16 x 2.5-inch hot-swappable SAS, SATA, or NVMe drives
- 24 x 2.5-inch hot-swappable SAS or SATA, or NVMe drives
- 16 x EDSFF E3.S hot-swappable NVMe drives
- 2 x 2.5-inch rear hot-swappable SAS, SATA, or NVMe drives
- 4 x 2.5-inch rear hot-swappable SAS, SATA, or NVMe drives
- 4 x EDSFF E3.S rear hot-swappable NVMe drives
USB ports specifications
| Front | Rear | Internal (optional) | |||
|---|---|---|---|---|---|
| USB port type | No. of ports | USB port type | No. of ports | USB port type | No. of ports |
| USB 2.0-compliant port | One | USB 2.0-compliant port | One | Internal USB 3.0-compliant port | One |
| iDRAC Direct port (Micro-AB USB 2.0-compliant port) | One | USB 3.0-compliant port | One | ||
NIC port specifications
| Feature | Specifications |
|---|---|
| LOM card (optional) | 1 GbE x 2 |
| OCP NIC card (OCP NIC 3.0) (optional) | 1GbE x 4, 10 GbE x 2, 10 GbE x 4, 25 GbE x 2, 25 GbE x 4, 100GbE x 2 |
| Management Interface Card (MIC) to support Dell Data Processing Unit (DPU) card (optional) | 25 GbE x 2, 100 GbE x 2 or 200 GbE x 2 |
Serial connector specifications
The PowerEdge R760 system supports one serial port on the system board, which is Data Terminal Equipment (DTE), 16550-compliant.
The optional serial connector card is installed similar to an expansion card filler bracket.
VGA ports specifications
The PowerEdge R760 system supports DB-15 VGA port on front panel and on rear I/O board (optional for Direct Liquid Cooling configuration).
Video specifications
| Resolution | Refresh rate (Hz) | Color depth (bits) |
|---|---|---|
| 1024 x 768 | 60 | 8, 16, 32 |
| 1280 x 800 | 60 | 8, 16, 32 |
| 1280 x 1024 | 60 | 8, 16, 32 |
| 1360 x 768 | 60 | 8, 16, 32 |
| 1440 x 900 | 60 | 8, 16, 32 |
| 1600 x 900 | 60 | 8, 16, 32 |
| 1600 x 1200 | 60 | 8, 16, 32 |
| 1680 x 1050 | 60 | 8, 16, 32 |
| 1920 x 1080 | 60 | 8, 16, 32 |
| 1920 x 1200 | 60 | 8, 16, 32 |
Environmental specifications
| Temperature | Specifications | |
|---|---|---|
| Allowable continuous operations | ||
| Temperature range for altitudes <= 900 m (<= 2953 ft) | 10–35°C (50–95°F) with no direct sunlight on the equipment | |
| Humidity percent range (non-condensing at all times) | 8% RH with -12°C (10.4°F) minimum dew point to 80% RH with 21°C (69.8°F) maximum dew point | |
| Operational altitude de-rating | Maximum temperature is reduced by 1°C/300 m (1.8°F/984 Ft) above 900 m (2953 Ft) | |
| Temperature | Specifications | |
|---|---|---|
| Allowable continuous operations | ||
| Temperature range for altitudes <= 900 m (<= 2953 ft) | 5–40°C (41–104°F) with no direct sunlight on the equipment | |
| Excursion Limited Operation | 5-35°C (41-95°F) Continuous Operation | |
| 35-40°C (95-104°F) 10% Annual Runtime | ||
| Humidity percent range (non-condensing at all times) | 8% RH with -12°C (10.4°F) minimum dew point to 85% RH with 24°C (75.2°F) maximum dew point | |
| Operational altitude de-rating | Maximum temperature is reduced by 1°C/175 m (1.8°F/574 Ft) above 900 m (2953 Ft) | |
| Temperature | Specifications | |
|---|---|---|
| Allowable continuous operations | ||
| Temperature range for altitudes <= 900 m (<= 2953 ft) | 5–45°C (41–113°F) with no direct sunlight on the equipment | |
| Excursion Limited Operation | 5-35°C (41-95°F) Continuous Operation | |
| 35-40°C (95-104°F) 10% Annual Runtime | ||
| 40-45°C (104-113°F) 1% Annual Runtime | ||
| Humidity percent range (non-condensing at all times) | 8% RH with -12°C (10.4°F) minimum dew point to 90% RH with 24°C (75.2°F) maximum dew point | |
| Operational altitude de-rating | Maximum temperature is reduced by 1°C/125 m (1.8°F/410 Ft) above 900 m (2953 Ft) | |
| Temperature | Specifications |
|---|---|
| Allowable continuous operations | |
| Maximum temperature gradient (applies to both operation and non-operation) | 20°C in an hour* (36°F in an hour) and 5°C in 15 minutes (9°F in 15 minutes), 5°C in an hour* (9°F in an hour) for tape hardware
NOTE:* - Per ASHRAE thermal guidelines for tape hardware, these are not instantaneous rates of temperature change.
|
| Non-operational temperature limits | -40 to 65°C (-40 to 149°F) |
| Non-operational humidity limits | 5% to 95% RH with 27°C (80.6°F) maximum dew point |
| Maximum non-operational altitude | 12,000 meters (39,370 feet) |
| Maximum operational altitude | 3,050 meters (10,006 feet) |
| Maximum vibration | Specifications |
|---|---|
| Operating | 0.21 Grms at 5 Hz to 500 Hz for 10 minutes (all operation orientations) |
| Storage | 1.88 Grms at 10 Hz to 500 Hz for 15 minutes (all six sides tested) |
| Maximum shock pulse | Specifications |
|---|---|
| Operating | Six consecutively executed shock pulses in the positive and negative x, y, and z axis of 6 G for up to 11 ms |
| Storage | Six consecutively executed shock pulses in the positive and negative x, y, and z axis (one pulse on each side of the system) of 71 G for up to 2 ms |
Particulate and gaseous contamination specifications
The following table defines the limitations that help avoid any equipment damage or failure from particulates and gaseous contamination. If the levels of particulates or gaseous pollution exceed the specified limitations and result in equipment damage or failure, you may need to rectify the environmental conditions. Remediation of environmental conditions is the responsibility of the customer.| Particulate contamination | Specifications |
|---|---|
| Air filtration | Data center air filtration as defined by ISO Class 8 per ISO 14644-1 with a 95% upper confidence limit
NOTE:This condition applies to data center environments only. Air filtration requirements do not apply to IT equipment designed to be used outside a data center, in environments such as an office or factory floor.
NOTE:Air entering the data center must have MERV11 or MERV13 filtration.
|
| Conductive dust | Air must be free of conductive dust, zinc whiskers, or other conductive particles
NOTE:This condition applies to data center and non-data center environments.
|
| Corrosive dust |
NOTE:This condition applies to data center and non-data center environments.
|
| Walk-Up Edge Data Center or Cabinet (sealed, closed loop environment) | Filtration is not required for cabinets that are anticipated to be opened 6 times or less per year. Class 8 per ISO 1466-1 filtration as defined above is required otherwise
NOTE: In environments commonly above ISA-71 Class G1 or that may have known challenges, special filters may be required.
|
| Gaseous contamination | Specifications |
|---|---|
| Copper coupon corrosion rate | <300 Å/month per Class G1 as defined by ANSI/ISA71.04-2013 |
| Silver coupon corrosion rate | <200 Å/month as defined by ANSI/ISA71.04-2013 |
Particulate and gaseous contamination specifications
The following table defines the limitations that help avoid any equipment damage or failure from particulates and gaseous contamination. If the levels of particulates or gaseous pollution exceed the specified limitations and result in equipment damage or failure, you must rectify the environmental conditions. Remediation of environmental conditions is the responsibility of the customer.
| Particulate contamination | Specifications |
|---|---|
| Air filtration: Conventional Data Center only | Data center air filtration as defined by ISO Class 8 per ISO 14644-1 with a 95% upper confidence limit
NOTE: Filtering room air with a MERV8 filter, as specified in ANSI/ASHRAE Standard 127, is a recommended method for achieving the necessary environmental conditions.
NOTE:Air entering the data center must have MERV11 or MERV13 filtration.
NOTE:This condition applies to data center environments only. Air filtration requirements do not apply to IT equipment designed to be used outside a data center, in environments such as an office or factory floor.
|
| Walk-Up Edge Data Center or Cabinet (sealed, closed loop environment) | Filtration is not required for cabinets that are anticipated to be opened six times or less per year. Class 8 per ISO 1466-1 filtration as defined above is required otherwise.
NOTE: In environments commonly above ISA-71 Class G1 or that may have known challenges, special filters may be required.
|
| Conductive dust: data center and non-data center environments | Air must be free of conductive dust, zinc whiskers, or other conductive particles.
NOTE: Conductive dust, which can interfere with equipment operation, can originate from various sources, including manufacturing processes and zinc whiskers that may develop on the plating of raised floor tiles.
NOTE:This condition applies to data center and non-data center environments.
|
| Corrosive dust: data center and non-data center environments |
NOTE:This condition applies to data center and non-data center environments.
|
| Gaseous contamination | Specifications | Notes |
|---|---|---|
| Copper coupon corrosion rate | ISA-71 Class G1: <300 Å/month | Per ANSI/ISA71.04 |
| Silver coupon corrosion rate | ISA-71 Class G1: <200 Å/month | Per ANSI/ISA71.04 |
Thermal air restrictions
| ASHRAE | A3/40°C (104°F) | A4/45°C (113°F) |
|---|---|---|
| PSU | Two PSUs are required in redundant mode. If there is PSU failure, system performance may be reduced. | |
| PCIe card | Non-Dell qualified peripheral cards and peripheral cards greater than 25 W are not supported. | |
| GPU/FPGA | Not supported | |
| DIMM | 128 GB, or greater capacity DIMMs are not supported. | |
| PCIe SSD | Not supported | |
| Front storage | Not supported in 12 x 3.5-inch SAS configuration. | |
| Rear storage | Not supported | |
| Fan | HPR SLVR fans are required. | |
| Processor | ≤ 165 W | ≤ 125 W |
| OCP | Supported with 85°C (185°F) active optic cable. | Supported with 85°C (185°F) active optic cable and cards tier ≤4. |
| BOSS | BOSS-N1 is supported. | BOS-N1 is not supported. |
| ASHRAE | A3/40°C (104°F) | A4/45°C (113°F) |
|---|---|---|
| PSU | Two PSUs are required in redundant mode. If there is PSU failure, system performance may be reduced. | |
| PCIe card | Non-Dell qualified peripheral cards and peripheral cards greater than 25 W are not supported. | |
| GPU/FPGA | Not supported | |
| DIMM | 128 GB, or greater capacity DIMMs are not supported. | |
| PCIe SSD | Not supported | |
| Front storage | Not supported in 12 x 3.5-inch SAS configuration. | |
| Rear storage | Not supported | |
| Fan | HPR SLVR fans are required in 2.5-inch configurations systems. | |
| OCP | Supported with 85°C (185°F) active optic cable. | Supported with 85°C (185°F) active optic cable and cards tier ≤4. |
| BOSS | BOSS-N1 is supported. | BOSS-N1 is not supported. |