Chassis dimensions

| Drives | Xa | Xb | Y | Za | Zb | Zc |
|---|---|---|---|---|---|---|
8 x EDSFF E3.S drives 16 x EDSFF E3.S drives Cold aisle configurations | 482 mm (19.0 inches) | 434 mm (17.1 inches) | 86.8 mm (3.42 inches) | 42.9 mm(1.69 inches) without bezel NOTE:Front bezel is
not supported in a front I/O configuration. | 700.7 mm (27.59 inches) Ear to rear wall | 771.6 mm (30.4 inches) |
12 x 3.5-inch drives 8 x 2.5-inch drives 16 x 2.5-inch drives 24 x 2.5-inch drives 32 x EDSFF E3.S drives | 482 mm (19.0 inches) | 434 mm (17.1 inches) | 86.8 mm (3.42 inches) | 30.78 mm (1.21 inches) with bezel 29.89 mm (1.18 inches) without bezel | 700.7 mm (27.59 inches) Ear to rear wall | 771.6 mm (30.4 inches) |
System weight
| System configuration | Maximum weight (with all drives/SSDs) |
|---|---|
| 8 x 2.5-inch SATA (HDD/SSD) | 25.2 kg (55.5 lb) |
| 16 x 2.5-inch SATA (HDD/SSD) | 27.1 kg (59.7 lb) |
| 24 x 2.5-inch SATA (HDD/SSD) | 28.6 kg (63.05 lb) |
| 12 x 3.5-inch SATA (HDD/SDD) | 31 kg (68.3 lb) |
| 8 x EDSFF E3.S Gen5 NVMe cold aisle configuration. | 27.8 kg (61.28 lb) |
| 8 x EDSFF E3.S Gen5 NVMe cold aisle configuration | 22.3 kg (49.16 lb) |
| 16 x EDSFF E3.S Gen5 NVMe cold aisle configuration | 22.9 kg (50.48 lb) |
| 32 x EDSFF E3.S Gen5 NVMe hot aisle configuration | 24.2 kg (53.35 lb) |
| Chassis weight | Description |
|---|---|
| 40–70 lbs | Recommend two people to lift. |
| 70–120 lbs | Recommend three people to lift. |
| ≥ 121 lbs | Recommend to use a server-lift. |
Processor specifications
| Supported processor | Number of processors supported |
|---|---|
| Intel® Xeon® 6 E-core processor | One |
| Intel® Xeon® 6 P-core processor | One |
| Processors | IDRAC | BIOS | FPGA |
|---|---|---|---|
| Intel® Xeon® 6 E-core processor | 1.10.17.00 | 1.1.3 | 106.102.000 |
| Intel® Xeon® 6 P-core processor | 1.20.25.00 | 1.2.6 | 107.102.000 |
PSU specifications
The PowerEdgeR570system supports up to two AC or DC power supply units (PSUs).
| PSU | Class | Heat dissipation (maximum) (BTU/hr) | Frequency (Hz) | AC Voltage | DC Voltage | Current (A) | ||||
|---|---|---|---|---|---|---|---|---|---|---|
| 200—240 V | 100—120 V | 277 V | 240 V | - (48—60) V | 336 V | |||||
| 800 W mixed mode | Platinum | 3000 | 50/60 | 800 W | 800 W | N/A | N/A | N/A | N/A | 9.2—4.5 A |
| Titanium | 3000 | 50/60 | 800 W | 800 W | N/A | N/A | N/A | N/A | 9.2—4.5 A | |
| N/A | 3000 | N/A | N/A | N/A | N/A | 800 W | N/A | N/A | 3.7 A | |
| 1100 W | Titanium | 4100 | 50/60 | 1100 W | 1050 W | N/A | N/A | N/A | N/A | 12—6.1 A |
| Platinum | 4100 | 50/60 | 1100 W | 1050 W | N/A | N/A | N/A | N/A | 12—6.1 A | |
| N/A | 4100 | N/A | N/A | N/A | N/A | 1100 W | N/A | N/A | 5.1 A | |
| 1400 W -48 VDC | Titanium | 5310 | N/A | N/A | N/A | N/A | N/A | 1400 W | N/A | 33 A |
| 1500 W 227 VAC | Titanium | 5625 | 50/60 | N/A | N/A | N/A | 1500 W | N/A | N/A | 6.1 A |
| N/A | 5625 | N/A | N/A | N/A | N/A | N/A | N/A | 1500 W | 4.91 A | |
| 1500 W mixed mode | Titanium | 5625 | 50/60 | 1500 W | 1050 W | N/A | N/A | N/A | N/A | 12—8.2 A |
| N/A | 5625 | N/A | N/A | N/A | N/A | 1500 W | N/A | N/A | 6.8 A | |
| 1800 W mixed mode | Titanium | 6750 | 50/60 | 1800 W | 1050 W | N/A | N/A | N/A | N/A | 9.8—8.2 A |
| N/A | 6750 | N/A | N/A | N/A | N/A | 1800 W | N/A | N/A | 8.2 A | |



| Form factor | Output | Power cable |
|---|---|---|
| Redundant 60 mm | 800 W mixed mode | C13 |
| 1100w mixed mode | C13 | |
| 1400w -48v DC | LOTES APOWA048 | |
| 1500 W mixed mode | C13 | |
| 1500w 277v | APP2006G1/2006G3 | |
| 1800 W mixed mode | C13 |
Cooling fan specifications
The PowerEdgeR570system supports up to six cooling fans.
| Fan type | Abbreviation | Also known as | Label color | Label image |
|---|---|---|---|---|
| High Performance Silver (HPR Silver) fans | HPR SLVR | Silver | Silver | ![]() |
| High Performance Gold (HPR Gold) fans | HPR GOLD | Gold | Gold | ![]() |
Supported operating systems
The PowerEdge R570 system supports the following operating systems:
- Canonical Ubuntu Server LTS
- RedHat Enterprise Linux
- SUSE Linux Enterprise Server
- VMware ESXi
- Windows Server
- Windows Server Datacenter
System battery specifications
The PowerEdge R570 system uses one CR 2032 3.0-V lithium coin cell battery.
Expansion card riser specifications
| PCIe slot | Expansion card riser | Processor connection | Height | Length | Slot width |
|---|---|---|---|---|---|
| Slot 2 | R1x | Processor 0 | Full Height | Half Length | x16 |
| Slot 3 | R2t | Processor 0 | Full Height | Half Length | x16 |
| Slot 4 |
R3e (Flop OCP) R3f (Flop OCP) |
Processor 0 | N/A | N/A | x16 |
| Slot 6 | BOSS (optional) | Processor 0 | N/A | N/A | x4 |
| Slot 7 | R5b | Processor 0 | Full Height | Half Length | x16 |
| Slot 9 | R4b | Processor 0 | Full Height | Half Length | x16 |
| Slot 10 | Onboard OCP (optional) | Processor 0 | N/A | N/A | x16 |
| Slot 31 | RF1a | Processor 0 | Full Height | Half Length | x16 |
| Slot 34 |
RF2a (Flop OCP) BOSS (optional) |
Processor 0 | N/A | N/A | x16/x4 |
| Slot 36 | RF3c | Processor 0 | Full Height | Half Length | x16 |
| Slot 38 | RF4b (Flop OCP) | Processor 0 | N/A | N/A | x16 |
Memory specifications
| DIMM type | Rank | Capacity | Single Processor | |||
|---|---|---|---|---|---|---|
| Intel® Xeon 6 E- core processor | Intel® Xeon 6 P- core processor | |||||
| Minimum system capacity | Maximum system capacity | Minimum system capacity | Maximum system capacity | |||
| RDIMM | 1 R | 16 GB | N/A | N/A | 16 GB | 128 GB |
| 2 R | 32 GB | 32 GB | 256 GB | 32 GB | 512 GB | |
| 64 GB | 512 GB | 1 TB | 256 GB | 1 TB | ||
| 96 GB | N/A | N/A | 768 GB | 1.5 TB | ||
| 128 GB | N/A | N/A | 1 TB | 2 TB | ||
| 8 R | 256 GB | N/A | N/A | 4 TB | 4 TB | |
| Memory module sockets | Speed |
|---|---|
| 16 DDR5 DIMM slots |
6400 MT/s (1DPC) 5200 MT/s (2DPC) |
Storage controller specifications
| Supported storage controller cards |
|---|
Internal controllers
|
External controllers
|
Internal boot
|
Software RAID
|
Drives
- Up to12 x 3.5-inch SATA (HDD) RAID hot-swappable drives + 4 x EDSFF E3.S Gen5 NVMe hot-swappable drives
- 8 x 2.5-inch NVMe (SSD) RAID hot-swappable drives
- 8 x 2.5-inch NVMe (SSD) hot-swappable drives
- 8 x 2.5-inch SATA (HDD/SSD) hot-swappable drives
- 8 x 2.5-inch SATA/Universal (HDD/SSD) hot-swappable drives
- 16 x 2.5-inch SATA (HDD/SSD) RAID hot-swappable drives
- 24 x 2.5-inch SATA (HDD/SSD) hot-swappable drives
- 8 x EDSFF E3.S (hot-aisle) Gen5 NVMe hot-swappable drives
- 8 x EDSFF E3.S (cold-aisle) Gen5 NVMe hot-swappable drives
- 16 x EDSFF E3.S (cold-aisle) Gen5 NVMe hot-swappable drives
- 16 x EDSFF E3.S (hot-aisle) Gen5 NVMe hot-swappable drives
- 32 x EDSFF E3.S (hot-aisle) Gen5 NVMe hot-swappable drives
GPU Specifications
- Up to four NVIDIA L4 24 GB 72 W single-width GPUs
- Up to three NVIDIA L40S 48 GB 350 W double-width GPUs
- Up to three NVIDIA H100 NVL 94 GB 400 W double-width GPUs
DPU Specifications
The PowerEdge R470 platform accommodates Data Processing Units (DPUs). These units are system-on-chip solutions that combine ARM cores, high-performance NICs, and programmable acceleration engines to offload and accelerate data center infrastructure services.
| Feature | Specifications |
|---|---|
| Model | NVIDIA BlueField-3 B3220 |
| Type | Data Processing Units (DPU) |
| Networking | 2 x 200 GbE |
| Form Factor | FHHL |
| Interface | PCIe Gen5 x16 |
| Power Consumption | 150 W |
| Compatible Risers | RC 1(Slot 7), RC 3(Slot 31), RC 4(Slot 31), RC 5(Slot 7), RC 6(Slot 7), RC 8(Slot 7), RC 9(Slot 7), RC 10( Slot 7), RC 11(Slot 7) |
NIC port specifications
| Feature | Specifications |
|---|---|
| Datacenter-Secure Control Module (DC-SCM) | 1 GbE x 1 |
| OCP NIC 3.0 card | 100 GbE x 2, 25 GbE x 2, 25 GbE x 4, 10 GbE x 2, 10 GbE x 4, 1 GbE x 4 |
USB ports specifications
| Front | Rear | Internal (Optional) | |||
|---|---|---|---|---|---|
| USB port type | No. of ports | USB port type | No. of ports | USB port type | No. of ports |
| USB 2.0-compliant port (optional) | One | USB 3.1-compliant port | Two | Internal USB 3.1-compliant port | One |
| USB type C dual-mode host/BMC Direct port | One | ||||
Serial connector specifications
The PowerEdge R570 system supports one optional card type connector, which is a 9 - pin connector, Data Terminal Equipment (DTE), 16550-compliant.
The optional serial connector card is available only in front I/O configuration.
Top USB port on DC-SCM supports external DB9 Dongle.
Video ports specifications
The PowerEdge R570 system supports one DB-15 VGA port (optional) on the rear I/O board and one Mini Display (mDP) port (optional) on the Left Control Panel (LCP) .
Video specifications
| Resolution | Refresh Rate | Color depth (bits) |
|---|---|---|
| 1024 x 768 | 60 | 8, 16, 32 |
| 1280 x 800 | 60 | 8, 16, 32 |
| 1280 x 1024 | 60 | 8, 16, 32 |
| 1360 x 768 | 60 | 8, 16, 32 |
| 1440 x 900 | 60 | 8, 16, 32 |
| 1600 x 900 | 60 | 8, 16, 32 |
| 1600 x 1200 | 60 | 8, 16, 32 |
| 1680 x 1050 | 60 | 8, 16, 32 |
| 1920 x 1080 | 60 | 8, 16, 32 |
| 1920 x 1200 | 60 | 8, 16, 32 |
Environmental specifications
| Parameters | Allowable continuous operations |
|---|---|
| Temperature range for altitudes <= 900 m (<= 2953 ft) | 10–35°C (50–95°F) with no direct sunlight on the equipment |
| Humidity percent range (non-condensing at all times) | 8% RH with -12°C minimum dew point to 80% RH with 21°C (69.8°F) maximum dew point |
| Operational altitude de-rating | Maximum temperature is reduced by 1°C/300 m (1.8°F/984 ft) above 900 m (2953 ft) |
| Parameters | Allowable continuous operations |
|---|---|
| Temperature range for altitudes <= 900 m (<= 2953 ft) | 5–40°C (41–104°F) with no direct sunlight on the equipment |
| Humidity percent range (non-condensing at all times) | 8% RH with -12°C minimum dew point to 85% RH with 24°C (75.2°F) maximum dew point |
| Operational altitude de-rating | Maximum temperature is reduced by 1°C/175 m (1.8°F/574 Ft) above 900 m (2953 Ft) |
| Parameters | Allowable continuous operations |
|---|---|
| Temperature range for altitudes <= 900 m (<= 2953 ft) | 5–45°C (41–113°F) with no direct sunlight on the equipment |
| Humidity percent range (non-condensing at all times) | 8% RH with -12°C minimum dew point to 90% RH with 24°C (75.2°F) maximum dew point |
| Operational altitude de-rating | Maximum temperature is reduced by 1°C/125 m (1.8°F/410 Ft) above 900 m (2953 Ft) |
| Parameters | Allowable continuous operations |
|---|---|
| Temperature range for altitudes <= 900 m (<= 2953 ft) | 5–55°C (41–131°F) with no direct sunlight on the equipment |
| Humidity percent range (non-condensing at all times) | 8% RH with -12°C minimum dew point to 90% RH with 24°C (75.2°F) maximum dew point |
| Operational altitude de-rating | Maximum temperature is reduced by 1°C/125 m (1.8°F/410 Ft) above 900 m (2953 Ft) |
| Parameters | Allowable continuous operations |
|---|---|
| Maximum temperature gradient (applies to both operation and non-operation) | 20°C in an hour* (36°F in an hour) and 5°C in 15 minutes (41°F in 15 minutes), 5°C in an hour* (41°F in an hour) for tape
NOTE:* - Per ASHRAE thermal guidelines for tape hardware, these are not instantaneous rates of temperature change.
|
| Non-operational temperature limits | -40°C to 65°C (-40°F to 149°F) |
| Non-operational humidity limits | 5% to 95% RH with 27°C (80.6°F) maximum dew point |
| Maximum non-operational altitude | 12,000 meters (39,370 ft) |
| Maximum operational altitude | 3,048 meters (10,000 ft) |
| Maximum vibration | Specifications |
|---|---|
| Operating | 0.21 Grms at 5 Hz to 500 Hz for 10 min (all x, y, and z axes) |
| Storage | 1.38 Grms at 7 Hz to 250 Hz for 15 minutes (all six sides tested) |
| Maximum shock pulse | Specifications |
|---|---|
| Operating | Six consecutively performed shock pulses in the positive and negative x, y, and z axis of 6 G for up to 11 ms. |
| Storage | Six consecutively performed shock pulses in the positive and negative x, y, and z axis (one pulse on each side of the system) of 71 G for up to 2 ms. |
Particulate and gaseous contamination specifications
The following table defines the limitations that help avoid any equipment damage or failure from particulates and gaseous contamination. If the levels of particulates or gaseous pollution exceed the specified limitations and result in equipment damage or failure, you must rectify the environmental conditions. Remediation of environmental conditions is the responsibility of the customer.
| Particulate contamination | Specifications |
|---|---|
| Air filtration: Conventional Data Center only | Data center air filtration as defined by ISO Class 8 per ISO 14644-1 with a 95% upper confidence limit
NOTE: Filtering room air with a MERV8 filter, as specified in ANSI/ASHRAE Standard 127, is a recommended method for achieving the necessary environmental conditions.
NOTE:Air entering the data center must have MERV11 or MERV13 filtration.
NOTE:This condition applies to data center environments only. Air filtration requirements do not apply to IT equipment designed to be used outside a data center, in environments such as an office or factory floor.
|
| Walk-Up Edge Data Center or Cabinet (sealed, closed loop environment) | Filtration is not required for cabinets that are anticipated to be opened six times or less per year. Class 8 per ISO 1466-1 filtration as defined above is required otherwise.
NOTE: In environments commonly above ISA-71 Class G1 or that may have known challenges, special filters may be required.
|
| Conductive dust: data center and non-data center environments | Air must be free of conductive dust, zinc whiskers, or other conductive particles.
NOTE: Conductive dust, which can interfere with equipment operation, can originate from various sources, including manufacturing processes and zinc whiskers that may develop on the plating of raised floor tiles.
NOTE:This condition applies to data center and non-data center environments.
|
| Corrosive dust: data center and non-data center environments |
NOTE:This condition applies to data center and non-data center environments.
|
| Gaseous contamination | Specifications | Notes |
|---|---|---|
| Copper coupon corrosion rate | ISA-71 Class G1: <300 Å/month | Per ANSI/ISA71.04 |
| Silver coupon corrosion rate | ISA-71 Class G1: <200 Å/month | Per ANSI/ISA71.04 |
Thermal restriction matrix
| Label | Description |
|---|---|
| STD | Standard |
| HPR | High performance |
| HPR Silver | High performance (HPR) Silver fan |
| HPR Gold | High Performance (HPR) Gold fan |
| HSK | Heat sink |
| LP | Low profile |
| FH | Full height |
| EXT | Extended |
| Heat sink | Processor TDP |
|---|---|
| 2U STD HSK |
|
| HPR HSK |
|
| Configuration |
Cold Aisle 8 x E3.S 16 x E3.S |
8 x 2.5-inch NVMe | 12 x 3.5-inch SAS/SATA | 12 x 3.5-inch SAS/SATA |
16 x 2.5-inch drives 24 x 2.5-inch drives |
Hot Aisle 8 x E3.S 16 x E3.S |
Hot Aisle 32 x E3.S |
Ambient temperature | ||
|---|---|---|---|---|---|---|---|---|---|---|
| Rear storage | No rear drives | No rear drives | Rear 4 x E3.S | No rear drives | No rear drives | No rear drives | No rear drives | |||
| Shroud | Regular Shroud | |||||||||
| Processor | TDP/cTDP | Fan/HSK | ||||||||
| 6710E | 205 W |
HPR Silver fan HPR HSK |
HPR Silver fan HPR HSK |
HPR Gold fan HPR HSK |
HPR Gold fan HPR HSK |
HPR Silver fan HPR HSK |
HPR Silver fan HPR HSK |
HPR Gold fan HPR HSK |
35°C | |
| 6756E | 225 W |
HPR Silver fan HPR HSK |
HPR Silver fan HPR HSK |
HPR Gold fan HPR HSK |
HPR Gold fan HPR HSK |
HPR Silver fan HPR HSK |
HPR Silver fan HPR HSK |
HPR Gold fan HPR HSK |
35°C | |
| 6740E/6766E/6731E/6746E | 250 W |
HPR Silver fan HPR HSK |
HPR Silver fan HPR HSK |
HPR Gold fan HPR HSK |
HPR Gold fan HPR HSK |
HPR Silver fan HPR HSK |
HPR Silver fan HPR HSK |
HPR Gold fan HPR HSK |
35°C | |
| 6780E | 330 W |
HPR Silver fan HPR HSK |
HPR Silver fan HPR HSK |
HPR Gold fan HPR HSK |
HPR Gold fan HPR HSK |
HPR Silver fan HPR HSK |
HPR Silver fan HPR HSK |
HPR Gold fan HPR HSK |
35°C | |
| 6507P/6505P/6511P | 150 W |
HPR Silver fan STD HSK |
HPR Silver fan STD HSK |
HPR Gold fan HPR HSK |
HPR Gold fan HPR HSK |
HPR Silver fan STD HSK |
HPR Silver fan STD HSK |
HPR Gold fan STD HSK |
35°C | |
| 6517P | 190 W |
HPR Silver fan HPR HSK |
HPR Silver fan HPR HSK |
HPR Gold fan HPR HSK |
HPR Gold fan HPR HSK |
HPR Silver fan HPR HSK |
HPR Silver fan HPR HSK |
HPR Gold fan HPR HSK |
35°C | |
| 6724P | 210 W |
HPR Silver fan HPR HSK |
HPR Silver fan HPR HSK |
HPR Gold fan HPR HSK |
HPR Gold fan HPR HSK |
HPR Silver fan HPR HSK |
HPR Silver fan HPR HSK |
HPR Gold fan HPR HSK |
35°C | |
| 6521P | 225 W |
HPR Silver fan HPR HSK |
HPR Silver fan HPR HSK |
HPR Gold fan HPR HSK |
HPR Gold fan HPR HSK |
HPR Silver fan HPR HSK |
HPR Silver fan HPR HSK |
HPR Gold fan HPR HSK |
35°C | |
| 6731P | 245 W |
HPR Silver fan HPR HSK |
HPR Silver fan HPR HSK |
HPR Gold fan HPR HSK |
HPR Gold fan HPR HSK |
HPR Silver fan HPR HSK |
HPR Silver fan HPR HSK |
HPR Gold fan HPR HSK |
35°C | |
| 6527P | 255 W |
HPR Silver fan HPR HSK |
HPR Silver fan HPR HSK |
HPR Gold fan HPR HSK |
HPR Gold fan HPR HSK |
HPR Silver fan HPR HSK |
HPR Silver fan HPR HSK |
HPR Gold fan HPR HSK |
35°C | |
| 6737P | 270 W |
HPR Silver fan HPR HSK |
HPR Silver fan HPR HSK |
HPR Gold fan HPR HSK |
HPR Gold fan HPR HSK |
HPR Silver fan HPR HSK |
HPR Silver fan HPR HSK |
HPR Gold fan HPR HSK |
35°C | |
| 6730P | 250 W |
HPR Silver fan HPR HSK |
HPR Silver fan HPR HSK |
HPR Gold fan HPR HSK |
HPR Gold fan HPR HSK |
HPR Silver fan HPR HSK |
HPR Silver fan HPR HSK |
HPR Gold fan HPR HSK |
35°C | |
| 6741P | 300 W |
HPR Silver fan HPR HSK |
HPR Silver fan HPR HSK |
HPR Gold fan HPR HSK |
HPR Gold fan HPR HSK |
HPR Silver fan HPR HSK |
HPR Silver fan HPR HSK |
HPR Gold fan HPR HSK |
35°C | |
| 6747P | 330 W |
HPR Silver fan HPR HSK |
HPR Silver fan HPR HSK |
HPR Gold fan HPR HSK |
HPR Gold fan HPR HSK |
HPR Silver fan HPR HSK |
HPR Silver fan HPR HSK |
HPR Gold fan HPR HSK |
35°C | |
| 6787P/6767P/6781P/6761P | 350 W |
HPR Silver fan HPR HSK |
HPR Silver fan HPR HSK |
HPR Gold fan HPR HSK |
HPR Gold fan HPR HSK |
HPR Silver fan HPR HSK |
HPR Silver fan HPR HSK |
HPR Gold fan HPR HSK |
35°C | |
| Memory | Ambient Temperature | |||||||||
| 16 GB RDIMM | 35°C | 35°C | 35°C | 35°C | 35°C | 35°C | 35°C | 35°C | ||
| 32 GB RDIMM | 35°C | 35°C | 35°C | 35°C | 35°C | 35°C | 35°C | 35°C | ||
| 64 GB RDIMM | 35°C | 35°C | 35°C | 35°C | 35°C | 35°C | 35°C | 35°C | ||
| 96 GB RDIMM | 35°C | 35°C | 35°C | 35°C | 35°C | 35°C | 35°C | 35°C | ||
| 128 GB RDIMM | 35°C | 35°C | 35°C | 35°C | 35°C | 35°C | 35°C | 35°C | ||
| Configuration |
Cold Aisle 8 x E3.S 16 x E3.S |
Ambient temperature | ||
|---|---|---|---|---|
| Rear storage | No rear drives | |||
| Shroud | GPU Shroud | |||
| Processor | TDP/cTDP | Fan/HSK | ||
| 6710E | 205 W |
HPR Gold fan 1U EXT HSK |
35°C | |
| 6756E | 225 W |
HPR Gold fan 1U EXT HSK |
35°C | |
| 6740E/6766E/6731E/6746E | 250 W |
HPR Gold fan 1U EXT HSK |
35°C | |
| 6780E | 330 W |
HPR Gold fan 1U EXT HSK |
35°C | |
| 6507P/6505P/6511P | 150 W |
HPR Gold fan 1U EXT HSK |
35°C | |
| 6517P | 190 W |
HPR Gold fan 1U EXT HSK |
35°C | |
| 6724P | 210 W |
HPR Gold fan 1U EXT HSK |
35°C | |
| 6521P | 225 W |
HPR Gold fan 1U EXT HSK |
35°C | |
| 6731P | 245 W |
HPR Gold fan 1U EXT HSK |
35°C | |
| 6527P | 255 W |
HPR Gold fan 1U EXT HSK |
35°C | |
| 6737P | 270 W |
HPR Gold fan 1U EXT HSK |
35°C | |
| 6730P | 250 W |
HPR Gold fan 1U EXT HSK |
35°C | |
| 6741P | 300 W |
HPR Gold fan 1U EXT HSK |
35°C | |
| 6747P | 330 W |
HPR Gold fan 1U EXT HSK |
35°C | |
| 6787P/6767P/6781P/6761P | 350 W |
HPR Gold fan 1U EXT HSK |
30°C | |
| Memory | Ambient Temperature | |||
| 16 GB RDIMM | 35°C | 35°C | ||
| 32 GB RDIMM | 35°C | 35°C | ||
| 64 GB RDIMM | 35°C | 35°C | ||
| 96 GB RDIMM | 35°C | 35°C | ||
| 128 GB RDIMM | 35°C | 35°C | ||
Thermal air restrictions
ASHRAE A3/A4
- Two PSUs are required in redundant mode, however a single PSU failure is not supported.
- NVMe drive including U.2 and E3.S is not supported.
- 128 GB or greater capacity DIMMs are not supported.
- GPU and FPGA are not supported.
- CPU TDP ≥ 190 W is not supported.
- Rear drives are not supported.
- Non-Dell qualified peripheral cards and/or peripheral cards greater than 25 W are not supported.
- 12 x 3.5-inch SAS/SATA drive configuration is not supported.
- M.2 module is not supported.
- OCP card with a transmission rate higher than 25G is not supported.
- NIC/OCP transceiver specification ≤ 75°C is not supported.
- PERC adapter card with battery is not supported.
NVIDIA L4 GPU
- In 24 x 2.5-inch drive and 32 x E3.S drive configurations, L4 with ≥ 270W CPU , it is limited at max ambient 30°C support and with ≤ 250W CPU can support max ambient 35°C.
- L4 cannot be supported in a 12 x 3.5-inch drive configurations.
- L4 can be supported at max ambient 35°C. However, with ≥ 300 W CPU SKUs, it is limited at max ambient 30°C support.
NVIDIA H100 NVL GPU
- H100 NVL is dedicated to cold aisle 8 x E3.S drive configuration.
- H100 NVL cannot be supported in a 12 x 3.5-inch, 24 x 2.5- Inch and 32 x E3.S drive configurations.
- H100 NVL can be supported at max ambient 35°C. However, with ≥ 300 W CPU SKUs, it is limited at max ambient 30°C support.
PCIe card Restrictions
- 12x3.5-inch, 24 x 2.5-inch and 32 x E3.S drive configuration requires the optical transceiver with higher temperature spec ≥ 85C support.
- DPU, 100 Gb network adapter, or 100 Gb OCP is not supported in 12x3.5” drive configuration.
- NVIDIA B3220 200G DPU requires a passive copper cable transceiver – MCP1650-H0XXXXX .
- 200G Broadcom network adaptor or OCP (250P7 / T635T) requires the optical transceiver with higher temperature spec (≥ 85C) support .
| ASHRAE | A3/40°C (104°F) | A4/45°C (113°F) |
|---|---|---|
| PSU | Two PSUs are required in redundant mode. Single PSU failure is not supported. | |
| PCIe card | Non-Dell qualified peripheral cards and peripheral cards greater than 25 W are not supported. | |
| GPU/FPGA | Not supported | |
| DIMM | 128 GB, or greater capacity DIMMs are not supported. | |
| Front storage | 12 x 3.5-inch SAS/SATA configuration is not supported. | |
| E3.S drive | E3.S drive configuration is not supported. | |
| U.2 NVMe drive | U.2 NVMe drive configuration is not supported. | |
| M.2 Module | M.2 module is not supported. | |
| Rear storage | Not supported | |
| Processor | CPU TDP ≥ 190 W is not supported. | |
| PERC | PERC adapter card with battery is not supported. | |
| NIC/OCP | transceiver spec ≤ 75 W is not supported. | |