Сегодня покупают
← Вернуться назад
Нужна помощь с конфигурацией?
Пришлите SKU, спецификацию или список требований. Специалист Apltech проверит совместимость компонентов и найдёт актуальные артикулы
Получить консультацию →

Dell PowerEdge R570: руководство по обслуживанию

Chassis dimensions

Figure 1. Chassis dimensions
This image shows chassis dimension for the PowerEge R7725 system.
Table 1. PowerEdgeR570 chassis dimensionsThis table provides the dimensions of the system:
Drives Xa Xb Y Za Zb Zc

8 x EDSFF E3.S drives
  

16 x EDSFF E3.S drives
  

Cold aisle configurations

482 mm (19.0 inches) 434 mm (17.1 inches) 86.8 mm (3.42 inches)42.9 mm(1.69 inches) without bezel
NOTE:Front bezel is not supported in a front I/O configuration.
700.7 mm (27.59 inches) Ear to rear wall 771.6 mm (30.4 inches)

12 x 3.5-inch drives

8 x 2.5-inch drives

16 x 2.5-inch drives

24 x 2.5-inch drives

32 x EDSFF E3.S drives
  

482 mm (19.0 inches) 434 mm (17.1 inches) 86.8 mm (3.42 inches)

30.78 mm (1.21 inches) with bezel

29.89 mm (1.18 inches) without bezel

700.7 mm (27.59 inches) Ear to rear wall 771.6 mm (30.4 inches)
NOTE:Zb is the nominal rear wall external surface where the HPM board I/O connectors reside.

System weight

Table 1. PowerEdge R570 system weightThe table below shows the maximum weight of the system.
System configuration Maximum weight (with all drives/SSDs)
8 x 2.5-inch SATA (HDD/SSD) 25.2 kg (55.5 lb)
16 x 2.5-inch SATA (HDD/SSD) 27.1 kg (59.7 lb)
24 x 2.5-inch SATA (HDD/SSD) 28.6 kg (63.05 lb)
12 x 3.5-inch SATA (HDD/SDD) 31 kg (68.3 lb)
8 x EDSFF E3.S Gen5 NVMe cold aisle configuration. 27.8 kg (61.28 lb)
8 x EDSFF E3.S Gen5 NVMe cold aisle configuration 22.3 kg (49.16 lb)
16 x EDSFF E3.S Gen5 NVMe cold aisle configuration 22.9 kg (50.48 lb)
32 x EDSFF E3.S Gen5 NVMe hot aisle configuration 24.2 kg (53.35 lb)
Table 2. PowerEdge R570 weight handling recommendationsThis table shows the recommendations in handling the system weight.
Chassis weight Description
40–70 lbs Recommend two people to lift.
70–120 lbs Recommend three people to lift.
≥ 121 lbs Recommend to use a server-lift.

Processor specifications

Table 1. PowerEdge R570 processor specifications This table provides processor specifications for the system.
Supported processor Number of processors supported
Intel® Xeon® 6 E-core processor One
Intel® Xeon® 6 P-core processor One
Table 2. Minimum Firmware requirement for Intel® Xeon® 6 E-core processor and Intel® Xeon® 6 P-core processorThis table lists the Minimum Firmware requirement for Intel® Xeon® 6 E-core processor and Intel® Xeon® 6 P-core processor.
Processors IDRAC BIOS FPGA
Intel® Xeon® 6 E-core processor 1.10.17.00 1.1.3 106.102.000
Intel® Xeon® 6 P-core processor 1.20.25.00 1.2.6 107.102.000

PSU specifications

The PowerEdgeR570system supports up to two AC or DC power supply units (PSUs).

Table 1. PSU specifications This table describes PSU specifications for the system.
PSU Class Heat dissipation (maximum) (BTU/hr) Frequency (Hz) AC Voltage DC Voltage Current (A)
200—240 V 100—120 V 277 V 240 V - (48—60) V 336 V
800 W mixed mode Platinum 3000 50/60 800 W 800 W N/A N/A N/A N/A 9.2—4.5 A
Titanium 3000 50/60 800 W 800 W N/A N/A N/A N/A 9.2—4.5 A
N/A 3000 N/A N/A N/A N/A 800 W N/A N/A 3.7 A
1100 WTitanium4100 50/60 1100 W1050 WN/A N/A N/A N/A 12—6.1 A
Platinum4100 50/60 1100 W1050 WN/A N/A N/A N/A 12—6.1 A
N/A 4100 N/A N/A N/A N/A 1100 WN/A N/A 5.1 A
1400 W -48 VDCTitanium5310N/A N/A N/A N/A N/A 1400 WN/A 33 A
1500 W 227 VACTitanium 5625 50/60 N/A N/A N/A1500 WN/A N/A 6.1 A
N/A 5625 N/A N/A N/A N/A N/A N/A 1500 W4.91 A
1500 W mixed mode Titanium 5625 50/60 1500 W 1050 W N/A N/A N/A N/A 12—8.2 A
N/A 5625 N/A N/A N/A N/A 1500 W N/A N/A 6.8 A
1800 W mixed modeTitanium 6750 50/60 1800 W 1050 W N/A N/A N/A N/A 9.8—8.2 A
N/A 6750 N/A N/A N/A N/A 1800 W N/A N/A 8.2 A
NOTE:Heat dissipation is calculated using the PSU wattage rating.
NOTE:When selecting or upgrading the system configuration, to ensure optimum power utilization, verify the system power consumption with the Enterprise Infrastructure Planning Tool available at calc.
NOTE:If a system with AC 1500 W PSUs operates at low line 100-120 Vac, then the power rating per PSU is degraded to 1050 W.
Figure 1. PSU power cables

this image shows C13 power cords

Figure 2. APP 2006G1 power cable

this image shows list of PSU power cord APP 2006G1

Figure 3. LOTES APOWA048 power cable

this image shows list of PSU power cord LOTES APOWA048

Table 2. PSU power cablesThe table lists the PSU power cables list .
Form factor Output Power cable
Redundant 60 mm 800 W mixed mode C13
1100w mixed modeC13
1400w -48v DCLOTES APOWA048
1500 W mixed mode C13
1500w 277vAPP2006G1/2006G3
1800 W mixed modeC13

Cooling fan specifications

The PowerEdgeR570system supports up to six cooling fans.

Table 1. Cooling fan specificationsCooling fan specifications
Fan type Abbreviation Also known as Label color Label image
High Performance Silver (HPR Silver) fans HPR SLVR Silver SilverThis shows the High Performance Silver (HPR SLVR) fan
High Performance Gold (HPR Gold) fansHPR GOLD Gold GoldThis shows the High Performance Gold (HPR GOLD) fan
NOTE:Cooling fans rotate at a slower speed, even while the system is in standby mode, and the fan speed varies in response to changes in the ambient temperature.

Supported operating systems

The PowerEdge R570 system supports the following operating systems:

  • Canonical Ubuntu Server LTS
  • RedHat Enterprise Linux
  • SUSE Linux Enterprise Server
  • VMware ESXi
  • Windows Server
  • Windows Server Datacenter
For specifications and interoperability details, see OS support.

System battery specifications

The PowerEdge R570 system uses one CR 2032 3.0-V lithium coin cell battery.

Expansion card riser specifications

The PowerEdge R570 system supports up to four PCI express (PCIe) slots (Gen5 slots), dual OCP NIC, and BOSS on the HPM board.
Table 1. Expansion card slots supported on the HPM boardThis table provides information about the expansion card slots that are supported on the system.
PCIe slot Expansion card riser Processor connection Height Length Slot width
Slot 2 R1x Processor 0 Full Height Half Length x16
Slot 3 R2t Processor 0 Full Height Half Length x16
Slot 4

R3e (Flop OCP)

R3f (Flop OCP)

Processor 0 N/A N/A x16
Slot 6 BOSS (optional) Processor 0 N/A N/A x4
Slot 7 R5b Processor 0 Full Height Half Length x16
Slot 9 R4b Processor 0 Full Height Half Length x16
Slot 10 Onboard OCP (optional) Processor 0 N/A N/A x16
Slot 31 RF1a Processor 0 Full Height Half Length x16
Slot 34

RF2a (Flop OCP)

BOSS (optional)

Processor 0 N/A N/A x16/x4
Slot 36 RF3c Processor 0 Full Height Half Length x16
Slot 38 RF4b (Flop OCP) Processor 0 N/A N/A x16

Memory specifications

The PowerEdge R570 system supports the following memory specifications for optimized operation.
Table 1. Memory specificationsThe table below shows the memory specifications:
DIMM type Rank Capacity Single Processor
Intel® Xeon 6 E- core processor Intel® Xeon 6 P- core processor
Minimum system capacity Maximum system capacity Minimum system capacity Maximum system capacity
RDIMM 1 R 16 GB N/A N/A 16 GB 128 GB
2 R 32 GB 32 GB 256 GB 32 GB 512 GB
64 GB 512 GB 1 TB 256 GB 1 TB
96 GB N/A N/A 768 GB 1.5 TB
128 GB N/A N/A 1 TB 2 TB
8 R 256 GB N/A N/A 4 TB 4 TB
NOTE: The RDIMM configuration depends on the DIMM capacity and the processor combination. Refer the System memory guidelines for more information.
Table 2. Memory module socketsThe table below shows the memory module sockets for the system:
Memory module sockets Speed
16 DDR5 DIMM slots

6400 MT/s  (1DPC)

5200 MT/s  (2DPC)

NOTE:Memory DIMM slots are not hot pluggable.
NOTE:The processor may reduce the performance of the rated DIMM speed.

Storage controller specifications

The PowerEdge R570 system supports the following controller cards:
Table 1. Storage controller cardsThis table provides the controller cards that are supported on the system:
Supported storage controller cards
Internal controllers
  • PERC H365i DC-MHS Front
  • PERC H965i DC-MHS Front
  • PERC H365i adapter
  • PERC H965i adapter
External controllers
  • PERC H965e
  • HBA 465e
Internal boot
  • Boot Optimized Storage Subsystem (BOSS-N1 DC-MHS)
  • M.2 interposer with up to 2 x M.2 NVMe SSDs
  • USB
Software RAID
  • N/A

Drives

The PowerEdge R570 system supports:
  • Up to12 x 3.5-inch SATA (HDD) RAID hot-swappable drives + 4 x EDSFF E3.S Gen5 NVMe hot-swappable drives
  • 8 x 2.5-inch NVMe (SSD) RAID hot-swappable drives
  • 8 x 2.5-inch NVMe (SSD) hot-swappable drives
  • 8 x 2.5-inch SATA (HDD/SSD) hot-swappable drives
  • 8 x 2.5-inch SATA/Universal (HDD/SSD) hot-swappable drives
  • 16 x 2.5-inch SATA (HDD/SSD) RAID hot-swappable drives
  • 24 x 2.5-inch SATA (HDD/SSD) hot-swappable drives
  • 8 x EDSFF E3.S (hot-aisle) Gen5 NVMe hot-swappable drives
  • 8 x EDSFF E3.S (cold-aisle) Gen5 NVMe hot-swappable drives
  • 16 x EDSFF E3.S (cold-aisle) Gen5 NVMe hot-swappable drives
  • 16 x EDSFF E3.S (hot-aisle) Gen5 NVMe hot-swappable drives
  • 32 x EDSFF E3.S (hot-aisle) Gen5 NVMe hot-swappable drives
NOTE: For more information about how to hot swap NVMe PCIe SSD device, see the Dell Express Flash NVMe PCIe SSD User's Guide at Dell Support page > Browse all products > Infrastructure > Data Center Infrastructure >  Storage Adapters & Controllers > Dell PowerEdge Express Flash NVMe PCIe SSD > Select This Product > Documentation > Manuals and Documents.

GPU Specifications

The PowerEdge R570 system supports
  • Up to four NVIDIA L4 24 GB 72 W single-width GPUs
  • Up to three NVIDIA L40S 48 GB 350 W double-width GPUs
  • Up to three NVIDIA H100 NVL 94 GB 400 W double-width GPUs

DPU Specifications

The PowerEdge R470 platform accommodates Data Processing Units (DPUs). These units are system-on-chip solutions that combine ARM cores, high-performance NICs, and programmable acceleration engines to offload and accelerate data center infrastructure services.

Table 1. Supported Data Processing Units(DPU) CardsThis table describes the feature and the specifications for the supported DPU cards in R570
Feature Specifications
Model NVIDIA BlueField-3 B3220
Type Data Processing Units (DPU)
Networking 2 x 200 GbE
Form Factor FHHL
Interface PCIe Gen5 x16
Power Consumption 150 W
Compatible Risers RC 1(Slot 7), RC 3(Slot 31), RC 4(Slot 31), RC 5(Slot 7), RC 6(Slot 7), RC 8(Slot 7), RC 9(Slot 7), RC 10( Slot 7), RC 11(Slot 7)

NIC port specifications

The PowerEdge R570 system supports one 10/100/1000 Mbps BMC Ethernet and two optional Open Compute Project (OCP) cards.
Table 1. NIC port specification for the systemThis table describes the NIC port specification for the system.
Feature Specifications
Datacenter-Secure Control Module (DC-SCM) 1 GbE x 1
OCP NIC 3.0 card 100 GbE x 2, 25 GbE x 2, 25 GbE x 4, 10 GbE x 2, 10 GbE x 4, 1 GbE x 4

USB ports specifications

Table 1. PowerEdge R570 USB specificationsThe following table shows the USB specifications for the system:
Front Rear Internal (Optional)
USB port type No. of ports USB port type No. of ports USB port type No. of ports
USB 2.0-compliant port (optional)One USB 3.1-compliant portTwo Internal USB 3.1-compliant portOne
USB type C dual-mode host/BMC Direct portOne

Serial connector specifications

The PowerEdge R570 system supports one optional card type connector, which is a 9 - pin connector, Data Terminal Equipment (DTE), 16550-compliant.

The optional serial connector card is available only in front I/O configuration.

Top USB port on DC-SCM supports external DB9 Dongle.

Video ports specifications

The PowerEdge R570 system supports one DB-15 VGA port (optional) on the rear I/O board and one Mini Display (mDP) port (optional) on the Left Control Panel (LCP) .

NOTE:Both ports cannot be used together. The mDP port overrides the VGA port.

Video specifications

Table 1. Supported video resolution optionsThis table describes the supported video resolution options for the system.
Resolution Refresh Rate Color depth (bits)
1024 x 768 60 8, 16, 32
1280 x 800 60 8, 16, 32
1280 x 1024 60 8, 16, 32
1360 x 768 60 8, 16, 32
1440 x 900 60 8, 16, 32
1600 x 900 60 8, 16, 32
1600 x 1200 60 8, 16, 32
1680 x 1050 60 8, 16, 32
1920 x 1080 60 8, 16, 32
1920 x 1200 60 8, 16, 32

Environmental specifications

NOTE:For additional information about environmental certifications, refer to the Product Environmental Datasheet located with the Manuals & Documents on Dell Support.
Table 1. Continuous Operation Specifications for ASHRAE A2 This table describes the operational climatic range for category A2.
Parameters Allowable continuous operations
Temperature range for altitudes <= 900 m (<= 2953 ft) 10–35°C (50–95°F) with no direct sunlight on the equipment
Humidity percent range (non-condensing at all times) 8% RH with -12°C minimum dew point to 80% RH with 21°C (69.8°F) maximum dew point
Operational altitude de-rating Maximum temperature is reduced by 1°C/300 m (1.8°F/984 ft) above 900 m (2953 ft)
Table 2. Continuous Operation Specifications for ASHRAE A3 This table describes the operational climatic range for category A3.
Parameters Allowable continuous operations
Temperature range for altitudes <= 900 m (<= 2953 ft) 5–40°C (41–104°F) with no direct sunlight on the equipment
Humidity percent range (non-condensing at all times) 8% RH with -12°C minimum dew point to 85% RH with 24°C (75.2°F) maximum dew point
Operational altitude de-rating Maximum temperature is reduced by 1°C/175 m (1.8°F/574 Ft) above 900 m (2953 Ft)
Table 3. Continuous Operation Specifications for ASHRAE A4 This table describes the operational climatic range for category A4.
Parameters Allowable continuous operations
Temperature range for altitudes <= 900 m (<= 2953 ft) 5–45°C (41–113°F) with no direct sunlight on the equipment
Humidity percent range (non-condensing at all times) 8% RH with -12°C minimum dew point to 90% RH with 24°C (75.2°F) maximum dew point
Operational altitude de-rating Maximum temperature is reduced by 1°C/125 m (1.8°F/410 Ft) above 900 m (2953 Ft)
Table 4. Continuous Operation Specifications for Rugged Environment This table describes the operational climatic range for category A4.
Parameters Allowable continuous operations
Temperature range for altitudes <= 900 m (<= 2953 ft) 5–55°C (41–131°F) with no direct sunlight on the equipment
Humidity percent range (non-condensing at all times) 8% RH with -12°C minimum dew point to 90% RH with 24°C (75.2°F) maximum dew point
Operational altitude de-rating Maximum temperature is reduced by 1°C/125 m (1.8°F/410 Ft) above 900 m (2953 Ft)
Table 5. Common Environmental Specifications for ASHRAE A2, A3, A4, and Rugged This table describes the shared requirements across all categories.
Parameters Allowable continuous operations
Maximum temperature gradient (applies to both operation and non-operation) 20°C in an hour* (36°F in an hour) and 5°C in 15 minutes (41°F in 15 minutes), 5°C in an hour* (41°F in an hour) for tape
NOTE:* - Per ASHRAE thermal guidelines for tape hardware, these are not instantaneous rates of temperature change.
Non-operational temperature limits -40°C to 65°C (-40°F to 149°F)
Non-operational humidity limits 5% to 95% RH with 27°C (80.6°F) maximum dew point
Maximum non-operational altitude 12,000 meters (39,370 ft)
Maximum operational altitude 3,048 meters (10,000 ft)
Table 6. Maximum vibration specificationsThe maximum vibration specification of an operational system is 0.26 Grms at 5 Hz to 350 Hz (all operation orientations). The maximum vibration specification of a nonoperational system is 1.88 Grms at 10 Hz to 500 Hz for 15 minutes (all six sides tested).
Maximum vibration Specifications
Operating 0.21 Grms at 5 Hz to 500 Hz for 10 min (all x, y, and z axes)
Storage 1.38 Grms at 7 Hz to 250 Hz for 15 minutes (all six sides tested)
Table 7. Maximum shock pulse specificationsThe maximum shock specification of an operational system is six consecutively performed shock pulses in the positive and negative x, y, and z axis of 40 G for up to 2.3 ms. The maximum shock specification of a non-operational system is six consecutively performed shock pulses in the positive and negative x, y, and z axis (one pulse on each side of the system) of 71 G for up to 2 ms.
Maximum shock pulse Specifications
Operating Six consecutively performed shock pulses in the positive and negative x, y, and z axis of 6 G for up to 11 ms.
Storage Six consecutively performed shock pulses in the positive and negative x, y, and z axis (one pulse on each side of the system) of 71 G for up to 2 ms.

Particulate and gaseous contamination specifications

The following table defines the limitations that help avoid any equipment damage or failure from particulates and gaseous contamination. If the levels of particulates or gaseous pollution exceed the specified limitations and result in equipment damage or failure, you must rectify the environmental conditions. Remediation of environmental conditions is the responsibility of the customer.

Table 1. Particulate contamination specificationsAir filtration specification: Data center air filtration as defined by ISO Class 8 per ISO 14644-1 should have a 95% upper confidence limit. Note: This condition applies only to data center environments. Air filtration requirements do not apply to IT equipment designed to be used outside a data center, in environments such as an office or factory floor. Note: Air entering the data center must have MERV11 or MERV13 filtration. Conductive dust specification: Air must be free of conductive dust, zinc whiskers, or other conductive particles. Note: This condition applies to data center and non-data center environments. Corrosive dust specification: Air must be free of corrosive dust. Residual dust present in the air must have a deliquescent point less than 60% relative humidity. Note: This condition applies to data center and non-data center environments.
Particulate contamination Specifications
Air filtration: Conventional Data Center only Data center air filtration as defined by ISO Class 8 per ISO 14644-1 with a 95% upper confidence limit
NOTE: Filtering room air with a MERV8 filter, as specified in ANSI/ASHRAE Standard 127, is a recommended method for achieving the necessary environmental conditions.
NOTE:Air entering the data center must have MERV11 or MERV13 filtration.
NOTE:This condition applies to data center environments only. Air filtration requirements do not apply to IT equipment designed to be used outside a data center, in environments such as an office or factory floor.
Walk-Up Edge Data Center or Cabinet (sealed, closed loop environment) Filtration is not required for cabinets that are anticipated to be opened six times or less per year. Class 8 per ISO 1466-1 filtration as defined above is required otherwise.
NOTE: In environments commonly above ISA-71 Class G1 or that may have known challenges, special filters may be required.
Conductive dust: data center and non-data center environments Air must be free of conductive dust, zinc whiskers, or other conductive particles.
NOTE: Conductive dust, which can interfere with equipment operation, can originate from various sources, including manufacturing processes and zinc whiskers that may develop on the plating of raised floor tiles.
NOTE:This condition applies to data center and non-data center environments.
Corrosive dust: data center and non-data center environments
  • Air must be free of corrosive dust.
  • Residual dust present in the air must have a deliquescent point less than 60% relative humidity.
NOTE:This condition applies to data center and non-data center environments.
Table 2. Gaseous contamination specificationsThe copper coupon corrosion rate is <300 Å/month per Class G1 as defined by ANSI/ISA71.04. The silver coupon corrosion rate is <200 Å/month as defined by ANSI/ISA71.04.
Gaseous contamination Specifications Notes
Copper coupon corrosion rate ISA-71 Class G1: <300 Å/month Per ANSI/ISA71.04
Silver coupon corrosion rate ISA-71 Class G1: <200 Å/month Per ANSI/ISA71.04

Thermal restriction matrix

Table 1. Label referenceThis table describes the label references used in the restriction tables.
Label Description
STD Standard
HPR High performance
HPR Silver High performance (HPR) Silver fan
HPR Gold High Performance (HPR) Gold fan
HSK Heat sink
LP Low profile
FH Full height
EXT Extended
Table 2. Processor and heat sink matrixThis table describes the processor and heat sink restriction matrix.
Heat sink Processor TDP
2U STD HSK
  • Require a regular shroud
  • CPU TDP ≤150 W in Non 12x3.5” configuration
HPR HSK
  • Require a regular shroud
  • CPU TDP > 150 W or all CPUs in 12x3.5” configuration
NOTE:The configuration's ambient temperature is dictated by its critical component. For example, if the processor's ambient temperature is 35°C, the DIMM is 35°C, and the GPU is 30°C, the configuration's ambient temperature can only be 30°C.
Table 3. Thermal restriction matrix for air cooling (non - GPU)The table describes the thermal restriction matrix for air cooling:
Configuration

Cold Aisle

8 x E3.S

16 x E3.S

8 x 2.5-inch NVMe 12 x 3.5-inch SAS/SATA 12 x 3.5-inch SAS/SATA

16 x 2.5-inch drives

24 x 2.5-inch drives

Hot Aisle

8 x E3.S

16 x E3.S

Hot Aisle 32 x E3.S

Ambient temperature
Rear storage No rear drives No rear drives Rear 4 x E3.S No rear drives No rear drives No rear drives No rear drives
Shroud Regular Shroud
Processor TDP/cTDP Fan/HSK
6710E 205 W

HPR Silver fan

HPR HSK

HPR Silver fan

HPR HSK

HPR Gold fan

HPR HSK

HPR Gold fan

HPR HSK

HPR Silver fan

HPR HSK

HPR Silver fan

HPR HSK

HPR Gold fan

HPR HSK

35°C
6756E 225 W

HPR Silver fan

HPR HSK

HPR Silver fan

HPR HSK

HPR Gold fan

HPR HSK

HPR Gold fan

HPR HSK

HPR Silver fan

HPR HSK

HPR Silver fan

HPR HSK

HPR Gold fan

HPR HSK

35°C
6740E/6766E/6731E/6746E 250 W

HPR Silver fan

HPR HSK

HPR Silver fan

HPR HSK

HPR Gold fan

HPR HSK

HPR Gold fan

HPR HSK

HPR Silver fan

HPR HSK

HPR Silver fan

HPR HSK

HPR Gold fan

HPR HSK

35°C
6780E 330 W

HPR Silver fan

HPR HSK

HPR Silver fan

HPR HSK

HPR Gold fan

HPR HSK

HPR Gold fan

HPR HSK

HPR Silver fan

HPR HSK

HPR Silver fan

HPR HSK

HPR Gold fan

HPR HSK

35°C
6507P/6505P/6511P 150 W

HPR Silver fan

STD HSK

HPR Silver fan

STD HSK

HPR Gold fan

HPR HSK

HPR Gold fan

HPR HSK

HPR Silver fan

STD HSK

HPR Silver fan

STD HSK

HPR Gold fan

STD HSK

35°C
6517P 190 W

HPR Silver fan

HPR HSK

HPR Silver fan

HPR HSK

HPR Gold fan

HPR HSK

HPR Gold fan

HPR HSK

HPR Silver fan

HPR HSK

HPR Silver fan

HPR HSK

HPR Gold fan

HPR HSK

35°C
6724P 210 W

HPR Silver fan

HPR HSK

HPR Silver fan

HPR HSK

HPR Gold fan

HPR HSK

HPR Gold fan

HPR HSK

HPR Silver fan

HPR HSK

HPR Silver fan

HPR HSK

HPR Gold fan

HPR HSK

35°C
6521P 225 W

HPR Silver fan

HPR HSK

HPR Silver fan

HPR HSK

HPR Gold fan

HPR HSK

HPR Gold fan

HPR HSK

HPR Silver fan

HPR HSK

HPR Silver fan

HPR HSK

HPR Gold fan

HPR HSK

35°C
6731P 245 W

HPR Silver fan

HPR HSK

HPR Silver fan

HPR HSK

HPR Gold fan

HPR HSK

HPR Gold fan

HPR HSK

HPR Silver fan

HPR HSK

HPR Silver fan

HPR HSK

HPR Gold fan

HPR HSK

35°C
6527P 255 W

HPR Silver fan

HPR HSK

HPR Silver fan

HPR HSK

HPR Gold fan

HPR HSK

HPR Gold fan

HPR HSK

HPR Silver fan

HPR HSK

HPR Silver fan

HPR HSK

HPR Gold fan

HPR HSK

35°C
6737P 270 W

HPR Silver fan

HPR HSK

HPR Silver fan

HPR HSK

HPR Gold fan

HPR HSK

HPR Gold fan

HPR HSK

HPR Silver fan

HPR HSK

HPR Silver fan

HPR HSK

HPR Gold fan

HPR HSK

35°C
6730P 250 W

HPR Silver fan

HPR HSK

HPR Silver fan

HPR HSK

HPR Gold fan

HPR HSK

HPR Gold fan

HPR HSK

HPR Silver fan

HPR HSK

HPR Silver fan

HPR HSK

HPR Gold fan

HPR HSK

35°C
6741P 300 W

HPR Silver fan

HPR HSK

HPR Silver fan

HPR HSK

HPR Gold fan

HPR HSK

HPR Gold fan

HPR HSK

HPR Silver fan

HPR HSK

HPR Silver fan

HPR HSK

HPR Gold fan

HPR HSK

35°C
6747P 330 W

HPR Silver fan

HPR HSK

HPR Silver fan

HPR HSK

HPR Gold fan

HPR HSK

HPR Gold fan

HPR HSK

HPR Silver fan

HPR HSK

HPR Silver fan

HPR HSK

HPR Gold fan

HPR HSK

35°C
6787P/6767P/6781P/6761P 350 W

HPR Silver fan

HPR HSK

HPR Silver fan

HPR HSK

HPR Gold fan

HPR HSK

HPR Gold fan

HPR HSK

HPR Silver fan

HPR HSK

HPR Silver fan

HPR HSK

HPR Gold fan

HPR HSK

35°C
Memory Ambient Temperature
16 GB RDIMM 35°C 35°C 35°C 35°C 35°C 35°C 35°C 35°C
32 GB RDIMM 35°C 35°C 35°C 35°C 35°C 35°C 35°C 35°C
64 GB RDIMM 35°C 35°C 35°C 35°C 35°C 35°C 35°C 35°C
96 GB RDIMM 35°C 35°C 35°C 35°C 35°C 35°C 35°C 35°C
128 GB RDIMM 35°C 35°C 35°C 35°C 35°C 35°C 35°C 35°C
Table 4. Thermal restriction matrix for air cooling (GPU)The table describes the thermal restriction matrix for air cooling:
Configuration

Cold Aisle

8 x E3.S

16 x E3.S

Ambient temperature
Rear storage No rear drives
Shroud GPU Shroud
Processor TDP/cTDP Fan/HSK
6710E 205 W

HPR Gold fan

1U EXT HSK

35°C
6756E 225 W

HPR Gold fan

1U EXT HSK

35°C
6740E/6766E/6731E/6746E 250 W

HPR Gold fan

1U EXT HSK

35°C
6780E 330 W

HPR Gold fan

1U EXT HSK

35°C
6507P/6505P/6511P 150 W

HPR Gold fan

1U EXT HSK

35°C
6517P 190 W

HPR Gold fan

1U EXT HSK

35°C
6724P 210 W

HPR Gold fan

1U EXT HSK

35°C
6521P 225 W

HPR Gold fan

1U EXT HSK

35°C
6731P 245 W

HPR Gold fan

1U EXT HSK

35°C
6527P 255 W

HPR Gold fan

1U EXT HSK

35°C
6737P 270 W

HPR Gold fan

1U EXT HSK

35°C
6730P 250 W

HPR Gold fan

1U EXT HSK

35°C
6741P 300 W

HPR Gold fan

1U EXT HSK

35°C
6747P 330 W

HPR Gold fan

1U EXT HSK

35°C
6787P/6767P/6781P/6761P 350 W

HPR Gold fan

1U EXT HSK

30°C
Memory Ambient Temperature
16 GB RDIMM 35°C 35°C
32 GB RDIMM 35°C 35°C
64 GB RDIMM 35°C 35°C
96 GB RDIMM 35°C 35°C
128 GB RDIMM 35°C 35°C

Thermal air restrictions

ASHRAE A3/A4

  • Two PSUs are required in redundant mode, however a single PSU failure is not supported.
  • NVMe drive including U.2 and E3.S is not supported.
  • 128 GB or greater capacity DIMMs are not supported.
  • GPU and FPGA are not supported.
  • CPU TDP ≥ 190 W is not supported.
  • Rear drives are not supported.
  • Non-Dell qualified peripheral cards and/or peripheral cards greater than 25 W are not supported.
  • 12 x 3.5-inch SAS/SATA drive configuration is not supported.
  • M.2 module is not supported.
  • OCP card with a transmission rate higher than 25G is not supported.
  • NIC/OCP transceiver specification ≤ 75°C is not supported.
  • PERC adapter card with battery is not supported.

NVIDIA L4 GPU

  • In 24 x 2.5-inch drive and 32 x E3.S drive configurations, L4 with ≥ 270W CPU , it is limited at max ambient 30°C support and with ≤ 250W CPU can support max ambient 35°C.
  • L4 cannot be supported in a 12 x 3.5-inch drive configurations.
  • L4 can be supported at max ambient 35°C. However, with ≥ 300 W CPU SKUs, it is limited at max ambient 30°C support.

NVIDIA H100 NVL GPU

  • H100 NVL is dedicated to cold aisle 8 x E3.S drive configuration.
  • H100 NVL cannot be supported in a 12 x 3.5-inch, 24 x 2.5- Inch and 32 x E3.S drive configurations.
  • H100 NVL can be supported at max ambient 35°C. However, with ≥ 300 W CPU SKUs, it is limited at max ambient 30°C support.

PCIe card Restrictions

  • 12x3.5-inch, 24 x 2.5-inch and 32 x E3.S drive configuration requires the optical transceiver with higher temperature spec ≥ 85C support.
  • DPU, 100 Gb network adapter, or 100 Gb OCP is not supported in 12x3.5” drive configuration.
  • NVIDIA B3220 200G DPU requires a passive copper cable transceiver – MCP1650-H0XXXXX .
  • 200G Broadcom network adaptor or OCP (250P7 / T635T) requires the optical transceiver with higher temperature spec (≥ 85C) support .
Table 1. Air cooling configuration thermal restriction for AHSRAE A3 and A4This table provides information about ASHRAE A3 and A4 restrictions for air cooling configuration.
ASHRAE A3/40°C (104°F) A4/45°C (113°F)
PSU Two PSUs are required in redundant mode. Single PSU failure is not supported.
PCIe card Non-Dell qualified peripheral cards and peripheral cards greater than 25 W are not supported.
GPU/FPGA Not supported
DIMM 128 GB, or greater capacity DIMMs are not supported.
Front storage 12 x 3.5-inch SAS/SATA configuration is not supported.
E3.S drive E3.S drive configuration is not supported.
U.2 NVMe drive U.2 NVMe drive configuration is not supported.
M.2 Module M.2 module is not supported.
Rear storage Not supported
Processor CPU TDP ≥ 190 W is not supported.
PERC PERC adapter card with battery is not supported.
NIC/OCP transceiver spec ≤ 75 W is not supported.