Dell PowerEdge R430: руководство по обслуживанию

Chassis dimensions

This section describes the physical dimensions of the system.
Figure 1. Chassis dimensions of the PowerEdge R430 system
Chassis dimensions for the PowerEdge R430 system
Table 1. Dimensions of the Dell PowerEdge R430 systemThis table gives details of the dimensions of the Dell PowerEdge R430 system. The dimensions are as follows: X = 482.4 mm, Xa = 434.0 mm, Y = 42.8 mm, Z(with bezel)= 677.3 mm, Z (without bezel) = 662.4 mm, Za (with bezel) = 35.0 mm, Za (without bezel) = 20.1 mm, and Zb=642.3 mm.
XXaYZ (with bezel)Z (without bezel)Za (with bezel) Za (without bezel)Zb
482.4 mm (18.99 inches)434.0 mm (17.08 inches)42.8 mm (1.68 inches)677.3 mm (26.66 inches)662.4 mm (264.07 inches)35.0 mm (1.37 inches)20.1 mm (0.79 inches)642.3 mm (25.28 inches)

Chassis weight

This section describes the weight of the system.
Table 1. Chassis weightFor PowerEdge R430 systems, the maximum chassis weight is 19.9 kg (43.87 lb).
System Maximum weight (with all hard drives/SSDs)
PowerEdge R430 19.9 kg (43.87 lb)

Processor specifications

The PowerEdge R430 system supports up to two Intel Xeon E5-2600 v3 or Intel Xeon E5-2600 v4 product family processors.

PSU specifications

The PowerEdge R430 system supports up to two AC redundant power supply units (PSUs) and a single AC cabled PSU.
Table 1. PSU specificationsFor 550 W AC, platinum power supply unit, the maximum heat dissipation is 2107 BTU/hr, frequency is 50/60 Hz, and voltage range is 100­240 V AC autoranging and the current rating is between 7.4 A-3.7 A. For 450 W AC Bronze PSU, the maximum heat dissipation is 1871 BTU/hr, frequency is 50/60 Hz, and voltage range is 100­240 V AC autoranging and the current rating is between 605 A-3.5 A.
PSU Class Heat dissipation (maximum) Frequency Voltage Current
550 W AC Platinum 2107 BTU/hr 50/60 Hz  100–240 V AC, autoranging 7.4 A-3.7 A
450 W AC Bronze 1871 BTU/hr 50/60 Hz  100–240 V AC, autoranging 6.5 A-3.5 A
NOTE Heat dissipation is calculated using the PSU wattage rating.
NOTE This system is also designed to connect to the IT power systems with a phase-to-phase voltage not exceeding 230 V.

System battery specifications

The PowerEdge R430 system supports 3 V CR2032 Lithium coin cell system battery.

Expansion bus specifications

The PowerEdge R430 system supports PCI express (PCIe) Generation 2 and 3 expansion cards, which need to be installed on the system board using expansion card risers. This system supports two types of expansion card risers. The following table provides the expansion card riser specifications:
Table 1. Expansion card riser specificationsThis table describes the details of the PICe slots on the expansion card risers. PCIE_G3_X16 riser supports PCIe slots 1 and 2 with low-profile, half-length, x16 link speed cards. PCIE_G3_X8 riser supports two PCIe cards on slots 1 and 2 with a full height, low profile, x8 link speed cards on slot 1 and a low-profile, half-length, x8 link speed card on slot 2
Expansion card riser PCIe slots on the riser Height Length Link
PCIE_G3_X16 riser Slot 1 low-profile half-length x16
Slot 2 low-profile half-length x16
PCIE_G3_X8 riser Slot 1 full-height half-length x8
Slot 2 low-profile half-length x8

Memory specifications

The PowerEdge R430 system supports DDR4 registered DIMMs (RDIMMs) and load-reduced DIMMs (LRDIMMs). Supported memory bus frequencies are 1866 MT/s, 2133MT/s, or 2400 MT/s.
Table 1. Memory specificationsYour system supports 12 memory module sockets of 288-pins each. The system supports RDIMMs of memory capacity 4 GB or 8 GB single rank, and RDIMMs of memory capacity 8 GB, 16 GB, or 32 GB dual rank. For system with single processor, the minimum RAM is 4 GB and the maximum RAM is up to 256 GB. For system with dual processor, the minimum RAM is 8 GB (minimum one memory module per processor) and the maximum RAM is up to 384 GB.
Memory module sockets Memory capacity Minimum RAM Maximum RAM
Twelve 288–pin
  • 4 GB single rank (RDIMMs)
  • 8 GB, 16 GB, or 32 GB dual rank (RDIMMs)
  • 4 GB with single processor
  • 8 GB with dual processors (minimum one memory module per processor)
  • Up to 256 GB with a single processor
  • Up to 384 GB with a dual processor

Hard drives

The PowerEdge R430 system supports SAS, SATA, Nearline SAS hard drives and Solid State Drives (SSDs).

Table 1. Supported hard drive and SSD options for the PowerEdge R430 systemThis table lists out the supported hard drive and SSD options for the PowerEdge 430 system.
Drive System Supports up to
Four hard drive systems

Up to four 3.5-inch cabled hard drives, or

Up to four 3.5-inch hot-swappable SAS, SATA, or Nearline SAS hard drives, or

Up to four 2.5-inch hot-swappable SAS, SATA, SATA SSD, or Nearline SAS hard drives.

NOTE Four hard-drive systems support software RAID. For more information about software RAID, see the Dell PowerEdge RAID Controller (PERC) documentation at dell.com/storagecontrollermanuals.
Eight hard-drive systems Up to eight 2.5-inch, hot-swappable SAS, SATA, SATA SSD, or Nearline SAS hard drives
Ten hard-drive systems Up to ten 2.5-inch, hot-swappable SATA hard drive or SATA SSD

Optical drive

The PowerEdge R430 system supports one optional SATA DVD-ROM drive or DVD+/-RW drive.
NOTE The optical drive is supported on the four hard-drive systems and eight hard-drive systems.

USB ports

The PowerEdge R430 system supports:
  • USB 2.0-compliant ports on the front panel
  • USB 3.0-complaint and USB 2.0-compliant ports on the back panel
  • USB 3.0-compliant internal port
The following table provides more information about the USB specifications:
Table 1. USB specificationsThe PowerEdge R430 system supports two 4-pin, USB 2.0-compliant ports on the front panel. Your system supports one 9-pin, USB 3.0-compliant port and one 4-pin, USB 2.0-compliant port on the back panel and one 9-pin, USB 3.0-compliant internal port.
System Front panel Back panel Internal
PowerEdge R430 Two 4-pin, USB 2.0-compliant ports

One 9-pin, USB 3.0-compliant port

One 4-pin, USB 2.0-compliant port

One 9-pin, USB 3.0-compliant port

NIC ports

The PowerEdge R430 system supports four 10/100/1000 Mbps Network Interface Controller (NIC) ports on the back panel.

Serial connector

The serial connector connects a serial device to the system. The PowerEdge R430 system supports one serial connector on the back panel, which is a 9-pin connector, Data Terminal Equipment (DTE), 16550-compliant.

VGA ports

The Video Graphic Array (VGA) port enables you to connect the system to a VGA display. The PowerEdge R430 system supports two 15-pin VGA ports one each on the front and back panels.

Internal Dual SD Module

The PowerEdge R430 system supports two optional flash memory card slots with an internal dual SD module.
NOTE One card slot is dedicated for redundancy.

Video specifications

The PowerEdge R430 system supports Matrox G200 graphics card with 16 MB capacity.
Table 1. Supported video resolution optionsFor 640 x 480 resolution, the refresh rate is 60 to 70 Hz and the color depth is 8, 16, 32 bit. For 800 x 600 resolution, the refresh rate is 60, 75, 85 Hz and color depth is 8, 16, 32 bit. For 1024 x 768 resolution, the refresh rate is 60, 75, 85 Hz and color depth is 8, 16, 32 bit. For 1152 x 864 resolution, the refresh rate is 60, 75, 85 Hz and color depth is 8, 16, 32 bit. For 1280 x 1024 resolution, the refresh rate is 60, 75 Hz and color depth is 8, 16, 32 bit. For 1440 x 900 resolution, the refresh rate is 60 Hz and color depth is 8, 16, 32 bit.
Resolution Refresh rate (Hz) Color depth (bits)
640 x 480 60, 70 8, 16, 32
800 x 600 60, 75, 85 8, 16, 32
1024 x 768 60, 75, 85 8, 16, 32
1152 x 864 60, 75, 85 8, 16, 32
1280 x 1024 60, 75 8, 16, 32
1440 x 900 60 8, 16, 32

Environmental specifications

NOTE For additional information about environmental measurements for specific system configurations, see Dell.com/environmental_datasheets.
Table 1. Temperature specificationsWhen the system is in continuous operation (for altitude less than 950 m or 3117 ft), the temperature specification ranges from 10°C to 35°C (50°F to 95°F) with no direct sunlight on the equipment. NOTE: Maximum of 145 W 22 core processor is supported in systems with eight 2.5-inches drives, two PCI slot chassis, and 75 W single wide active GPU. When the system is not in operation, the temperature specification is –40°C to 65°C (–40°F to 149°F). The Maximum temperature gradient for both operation and non-operational systems is 20°C/h (36°F/h).
Temperature Specifications
Storage –40°C to 65°C (–40°F to 149°F)
Continuous operation (for altitude less than 950 m or 3117 ft) 10°C to 35°C (50°F to 95°F) with no direct sunlight on the equipment.
Maximum temperature gradient (operating and storage) 20°C/h (36°F/h)
Table 2. Relative humidity specificationsFor a non-operational system, the ambient relative humidity ranges from 5% to 95% with 33°C (91°F) maximum dew point. Atmosphere must be non-condensing at all times. For an operational system, the ambient relative humidity ranges from 10% to 80% with 29°C (84.2°F) maximum dew point.
Relative humidity Specifications
Storage 5% to 95% RH with 33°C (91°F) maximum dew point. Atmosphere must be non-condensing at all times.
Operating 10% to 80% relative humidity with 29°C (84.2°F) maximum dew point.
Table 3. Maximum vibration specificationsThe maximum vibration specification of an operational system is 0.26 Grms at 5 Hz to 350 Hz (all operation orientations).The maximum vibration specification of a non-operational system is 1.88 Grms at 10 Hz to 500 Hz for 15 min (all six sides tested).
Maximum vibration Specifications
Operating 0.26 Grms at 5 Hz to 350 Hz (all operation orientations).
Storage 1.88 Grms at 10 Hz to 500 Hz for 15 min (all six sides tested).
Table 4. Maximum shock specificationsThe maximum shock specification of an operational system is six consecutively executed shock pulses in the positive and negative x, y, and z axes of 40 G for up to 2.3 ms. The maximum shock specification of a non-operational system is six consecutively executed shock pulses in the positive and negative x, y, and z axes (one pulse on each side of the system) of 71 G for up to 2 ms.
Maximum shock Specifications
Operating Six consecutively executed shock pulses in the positive and negative x, y, and z axes of 40 G for up to 2.3 ms.
Storage Six consecutively executed shock pulses in the positive and negative x, y, and z axes (one pulse on each side of the system) of 71 G for up to 2 ms.
Table 5. Maximum altitude specificationsThe maximum altitude specification for an operational system is 3048 m (10,000 ft). The maximum altitude specification for a non-operational system is 12,000 m (39,370 ft).
Maximum altitude Specifications
Operating

30482000 m (10,0006560 ft)

Storage 12,000 m (39,370 ft)
Table 6. Operating temperature de-rating specificationsIf the operating temerature of a system is up to 35 °C (95 °F), the maximum temperature is reduced by 1 °C/300 m (1 °F/547 ft) above 950 m (3,117 ft). If the operating temperature of a system ranges from 35 °C to 40 °C (95 °F to 104 °F), the maximum temperature is reduced by 1 °C/175 m (1 °F/319 ft) above 950 m (3,117 ft). If the operating temperature of a system ranges from 40 °C to 45 °C (104 °F to 113 °F), the maximum temperature is reduced by 1 °C/125 m (1 °F/228 ft) above 950 m (3,117 ft).
Operating temperature de-rating Specifications
Up to 35°C (95°F) Maximum temperature is reduced by 1°C/300 m (1°F/547 ft) above 950 m (3,117 ft).
35°C to 40°C (95°F to 104°F) Maximum temperature is reduced by 1°C/175 m (1°F/319 ft) above 950 m (3,117 ft).
40°C to 45°C (104°F to 113°F) Maximum temperature is reduced by 1°C/125 m (1°F/228 ft) above 950 m (3,117 ft).

Particulate and gaseous contamination specifications

The following table defines the limitations that help avoid any equipment damage or failure from particulates and gaseous contamination. If the levels of particulates or gaseous pollution exceed the specified limitations and result in equipment damage or failure, you may need to rectify the environmental conditions. Re-mediation of environmental conditions is the responsibility of the customer.
Table 1. Particulate contamination specificationsAir filtration specification: Data center air filtration as defined by ISO Class 8 per ISO 14644-1 shpuld have a 95% upper confidence limit. Note: This condition applies only to data center environments. Air filtration requirements do not apply to IT equipment designed to be used outside a data center, in environments such as an office or factory floor. Note: Air entering the data center must have MERV11 or MERV13 filtration. Conductive dust specification: Air must be free of conductive dust, zinc whiskers, or other conductive particles. Note: This condition applies to data center and non-data center environments. Corrosive dust specification: Air must be free of corrosive dust. Residual dust present in the air must have a deliquescent point less than 60% relative humidity. Note: This condition applies to data center and non-data center environments.
Particulate contamination Specifications
Air filtration Data center air filtration as defined by ISO Class 8 per ISO 14644-1 with a 95% upper confidence limit.
NOTE This condition applies to data center environments only. Air filtration requirements do not apply to IT equipment designed to be used outside a data center, in environments such as an office or factory floor.
NOTE Air entering the data center must have MERV11 or MERV13 filtration.
Conductive dust Air must be free of conductive dust, zinc whiskers, or other conductive particles.
NOTE This condition applies to data center and non-data center environments.
Corrosive dust
  • Air must be free of corrosive dust.
  • Residual dust present in the air must have a deliquescent point less than 60% relative humidity.
NOTE This condition applies to data center and non-data center environments.
Table 2. Gaseous contamination specificationsThe copper coupon corrosion rate is <300 Å/month per Class G1 as defined by ANSI/ISA71.04-1985. The silver coupon corrosion rate is <200 Å/month as defined by AHSRAE TC9.9.
Gaseous contamination Specifications
Copper coupon corrosion rate <300 Å/month per Class G1 as defined by ANSI/ISA71.04-1985.
Silver coupon corrosion rate <200 Å/month as defined by AHSRAE TC9.9.
NOTE Maximum corrosive contaminant levels measured at ≤50% relative humidity.

Expanded operating temperature

Table 1. Expanded operating temperature specificationsWhen the system is at 10% of annual operating hours, the expanded operating temperature ranges from 5°C to 40°C at 5% to 85% RH with 29°C dew point. NOTE: Outside the standard operating temperature (10°C to 35°C), the system can operate continuously in temperatures as low as 5°C and as high as 40°C. For temperatures between 35°C and 40°C, de-rate maximum allowable dry bulb temperature by 1°C per 175 m above 950 m (1°F per 319 ft). When the system is operating at < 1% of annual operating hours, the expanded operating temperature is –5°C to 45°C at 5% to 90% RH with 29°C dew point. NOTE: Outside the standard operating temperature (10°C to 35°C), the system can operate down to –5°C or up to 45°C for a maximum of 1% of its annual operating hours. For temperatures between 40°C and 45°C, de-rate maximum allowable temperature by 1°C per 125 m above 950 m (1°F per 228 ft).
Expanded operating temperature Specifications
Continuous operation 5°C to 40°C at 5% to 85% RH with 29°C dew point.
NOTE Outside the standard operating temperature (10°C to 35°C), the system can operate continuously in temperatures as low as 5°C and as high as 40°C.

For temperatures between 35°C and 40°C, de-rate maximum allowable dry bulb temperature by 1°C per 175 m above 950 m (1°F per 319 ft).

< 1% of annual operating hours –5°C to 45°C at 5% to 90% RH with 29°C dew point.
NOTE Outside the standard operating temperature (10°C to 35°C), the system can operate down to –5°C or up to 45°C for a maximum of 1% of its annual operating hours.

For temperatures between 40°C and 45°C, de-rate maximum allowable temperature by 1°C per 125 m above 950 m (1°F per 228 ft).

NOTE When operating in the expanded temperature range, system performance may be impacted.
NOTE When operating in the expanded temperature range, ambient temperature warnings maybe reported on the LCD panel and in the System Event Log.

Expanded operating temperature restrictions

  • Processors of 55 W and 65 W are not supported.

  • Do not perform a cold startup below 5°C.

  • Allow processor performance degrade.

  • Non-redundant power supplies are not supported.

  • Non Dell qualified peripheral cards and/or peripheral cards are not supported.

  • Maximum altitude for the operating temperature must be 3050 m (10,000 ft).