Chassis dimensions

| X | Xa | Y | Z (with bezel) | Z (without bezel) | Za (with bezel) | Za (without bezel) | Zb |
|---|---|---|---|---|---|---|---|
| 482.4 mm (18.99 inches) | 434.0 mm (17.08 inches) | 42.8 mm (1.68 inches) | 677.3 mm (26.66 inches) | 662.4 mm (264.07 inches) | 35.0 mm (1.37 inches) | 20.1 mm (0.79 inches) | 642.3 mm (25.28 inches) |
Chassis weight
| System | Maximum weight (with all hard drives/SSDs) |
|---|---|
| PowerEdge R430 | 19.9 kg (43.87 lb) |
Processor specifications
PSU specifications
| PSU | Class | Heat dissipation (maximum) | Frequency | Voltage | Current |
|---|---|---|---|---|---|
| 550 W AC | Platinum | 2107 BTU/hr | 50/60 Hz | 100–240 V AC, autoranging | 7.4 A-3.7 A |
| 450 W AC | Bronze | 1871 BTU/hr | 50/60 Hz | 100–240 V AC, autoranging | 6.5 A-3.5 A |
System battery specifications
Expansion bus specifications
| Expansion card riser | PCIe slots on the riser | Height | Length | Link |
|---|---|---|---|---|
| PCIE_G3_X16 riser | Slot 1 | low-profile | half-length | x16 |
| Slot 2 | low-profile | half-length | x16 | |
| PCIE_G3_X8 riser | Slot 1 | full-height | half-length | x8 |
| Slot 2 | low-profile | half-length | x8 |
Memory specifications
| Memory module sockets | Memory capacity | Minimum RAM | Maximum RAM |
|---|---|---|---|
| Twelve 288–pin |
|
|
|
Hard drives
The PowerEdge R430 system supports SAS, SATA, Nearline SAS hard drives and Solid State Drives (SSDs).
| Drive System | Supports up to |
|---|---|
| Four hard drive systems |
Up to four 3.5-inch cabled hard drives, or Up to four 3.5-inch hot-swappable SAS, SATA, or Nearline SAS hard drives, or Up to four 2.5-inch hot-swappable SAS, SATA, SATA SSD, or Nearline SAS hard drives. NOTE Four hard-drive systems support software RAID. For more information about software RAID, see the Dell PowerEdge RAID Controller (PERC) documentation at
dell.com/storagecontrollermanuals.
|
| Eight hard-drive systems | Up to eight 2.5-inch, hot-swappable SAS, SATA, SATA SSD, or Nearline SAS hard drives |
| Ten hard-drive systems | Up to ten 2.5-inch, hot-swappable SATA hard drive or SATA SSD |
Optical drive
USB ports
- USB 2.0-compliant ports on the front panel
- USB 3.0-complaint and USB 2.0-compliant ports on the back panel
- USB 3.0-compliant internal port
| System | Front panel | Back panel | Internal |
|---|---|---|---|
| PowerEdge R430 | Two 4-pin, USB 2.0-compliant ports | One 9-pin, USB 3.0-compliant port One 4-pin, USB 2.0-compliant port |
One 9-pin, USB 3.0-compliant port |
NIC ports
Serial connector
VGA ports
Internal Dual SD Module
Video specifications
| Resolution | Refresh rate (Hz) | Color depth (bits) |
|---|---|---|
| 640 x 480 | 60, 70 | 8, 16, 32 |
| 800 x 600 | 60, 75, 85 | 8, 16, 32 |
| 1024 x 768 | 60, 75, 85 | 8, 16, 32 |
| 1152 x 864 | 60, 75, 85 | 8, 16, 32 |
| 1280 x 1024 | 60, 75 | 8, 16, 32 |
| 1440 x 900 | 60 | 8, 16, 32 |
Environmental specifications
| Temperature | Specifications |
|---|---|
| Storage | –40°C to 65°C (–40°F to 149°F) |
| Continuous operation (for altitude less than 950 m or 3117 ft) | 10°C to 35°C (50°F to 95°F) with no direct sunlight on the equipment. |
| Maximum temperature gradient (operating and storage) | 20°C/h (36°F/h) |
| Relative humidity | Specifications |
|---|---|
| Storage | 5% to 95% RH with 33°C (91°F) maximum dew point. Atmosphere must be non-condensing at all times. |
| Operating | 10% to 80% relative humidity with 29°C (84.2°F) maximum dew point. |
| Maximum vibration | Specifications |
|---|---|
| Operating | 0.26 Grms at 5 Hz to 350 Hz (all operation orientations). |
| Storage | 1.88 Grms at 10 Hz to 500 Hz for 15 min (all six sides tested). |
| Maximum shock | Specifications |
|---|---|
| Operating | Six consecutively executed shock pulses in the positive and negative x, y, and z axes of 40 G for up to 2.3 ms. |
| Storage | Six consecutively executed shock pulses in the positive and negative x, y, and z axes (one pulse on each side of the system) of 71 G for up to 2 ms. |
| Maximum altitude | Specifications |
|---|---|
| Operating | 30482000 m (10,0006560 ft) |
| Storage | 12,000 m (39,370 ft) |
| Operating temperature de-rating | Specifications |
|---|---|
| Up to 35°C (95°F) | Maximum temperature is reduced by 1°C/300 m (1°F/547 ft) above 950 m (3,117 ft). |
| 35°C to 40°C (95°F to 104°F) | Maximum temperature is reduced by 1°C/175 m (1°F/319 ft) above 950 m (3,117 ft). |
| 40°C to 45°C (104°F to 113°F) | Maximum temperature is reduced by 1°C/125 m (1°F/228 ft) above 950 m (3,117 ft). |
Particulate and gaseous contamination specifications
| Particulate contamination | Specifications |
|---|---|
| Air filtration | Data center air filtration as defined by ISO Class
8 per ISO 14644-1 with a 95% upper confidence limit. NOTE This condition applies
to data center environments only. Air filtration requirements do not
apply to IT equipment designed to be used outside a data center, in
environments such as an office or factory floor. NOTE Air entering the data
center must have MERV11 or MERV13 filtration. |
| Conductive dust | Air must be free of conductive dust, zinc whiskers,
or other conductive particles. NOTE This condition applies
to data center and non-data center environments. |
| Corrosive dust |
NOTE This condition
applies to data center and non-data center environments. |
| Gaseous contamination | Specifications |
|---|---|
| Copper coupon corrosion rate | <300 Å/month per Class G1 as defined by ANSI/ISA71.04-1985. |
| Silver coupon corrosion rate | <200 Å/month as defined by AHSRAE TC9.9. |
Expanded operating temperature
| Expanded operating temperature | Specifications |
|---|---|
| Continuous operation | 5°C to 40°C at 5% to 85% RH with 29°C dew point. NOTE Outside the standard
operating temperature (10°C to 35°C), the system can operate continuously
in temperatures as low as 5°C and as high as 40°C. For temperatures between 35°C and 40°C, de-rate maximum allowable dry bulb temperature by 1°C per 175 m above 950 m (1°F per 319 ft). |
| < 1% of annual operating hours | –5°C to 45°C at 5% to 90% RH with 29°C dew point. NOTE Outside the standard
operating temperature (10°C to 35°C), the system can operate down
to –5°C or up to 45°C for a maximum of 1% of its annual operating
hours. For temperatures between 40°C and 45°C, de-rate maximum allowable temperature by 1°C per 125 m above 950 m (1°F per 228 ft). |
Expanded operating temperature restrictions
Processors of 55 W and 65 W are not supported.
Do not perform a cold startup below 5°C.
Allow processor performance degrade.
Non-redundant power supplies are not supported.
Non Dell qualified peripheral cards and/or peripheral cards are not supported.
Maximum altitude for the operating temperature must be 3050 m (10,000 ft).