Chassis dimensions

| Drives | Xa | Xb | Y | Za | Zb | Zc |
|---|---|---|---|---|---|---|
| 12 drives | 482.0 mm
(18.97 inches) | 434.0 mm
(17.08 inches) | 86.8 mm
(3.41 inches) | With bezel: 35.84 mm (1.4 inches) Without bezel: 22.0 mm (0.87 inches) | 700.7 mm
(27.58 inches) (Ear to rear wall) | 736.29 mm
(28.98 inches) (Ear to PSU handle) |
| 24 drives | 482.0 mm
(18.97 inches) | 434.0 mm
(17.08 inches) | 86.8 mm
(3.41 inches) | With bezel: 35.84 mm (1.4 inches) Without bezel: 22.0 mm (0.87 inches) | 700.7 mm
(27.58 inches) (Ear to rear wall) | 736.29 mm
(28.98 inches) (Ear to PSU handle) |
Chassis weight
| System configuration | Maximum weight (with all drives/SSDs) |
|---|---|
| 12 x 3.5-inch | 36.3 kg (80.02 lb) |
| 8 x 3.5-inch | 33.2 kg (73.19 lb) |
| 24 x 2.5-inch | 28.6 kg (63.05 lb) |
| 16 x 2.5-inch | 26.6 kg (58.64 lb) |
| 8 x 2.5-inch | 24.6 kg (54.23 lb) |
Processor specifications
| Supported processor | Number of processors supported |
|---|---|
| AMD EPYC 7002 or 7003 series processor | Two |
PSU specifications
The PowerEdge R7525 system supports up to two AC or DC power supply units (PSUs).
System using -(48-60) V DC or 240 V DC power supplies are intended for restricted access locations in accordance with Articles 110-5, 110-6, 110-11, 110-14, and 110-17 of the National Electrical Code, American National Standards Institute (ANSI)/National Fire Protection Association (NFPA) 70.
240 V DC power supplies shall be connected to the 240 V DC outlet from certified power distribution units if applicable in country of use.
Power supply cords/jumper cords and the associated plugs/inlets/connectors shall have appropriate electrical ratings referencing the rating label on the system when used for connection.
| PSU | Class (AC only) | Heat dissipation (maximum) | Frequency | Voltage | Current |
|---|---|---|---|---|---|
| 800 W Mixed Mode | Platinum | 3000 BTU/hr | 50/60 Hz | 100 -240 V AC | 9.2 - 4.7 A |
| N/A | DC | 240 V DC | 3.8 A | ||
| 1100 W Mixed Mode | Titanium | 4100 BTU/hr | 50/60 Hz | 100–240 V AC | 12 A-6.3 A (X2) |
| N/A | DC | 240 V DC | 5.2 A DC | ||
| 1100 W (-48Vdc) | N/A | 4265 BTU/hr | DC | (-48)-(-60) V DC | 27 A |
| 1400 W Mixed Mode | Platinum | 5250 BTU/hr | 50/60 Hz | 100 - 240 V AC | 12 - 8 A AC |
| N/A | DC | 240 V DC | 6.6 A DC | ||
| 2400W Mixed Mode | Platinum | 9000 BTU/hr | 50/60 Hz | 100 - 240 V AC | 13.5 - 11 A AC |
| N/A | DC | 240 V DC | 11.2 A DC |
Supported operating systems
The PowerEdge R7525 supports the following operating systems:
- Canonical Ubuntu Server LTS
- Citrix XenServer
- Microsoft Windows Server with Hyper-V
- Red Hat Enterprise Linux
- SUSE Linux Enterprise Server
- VMware vSAN/ESXi
Cooling fan specifications
The PowerEdgeR7525 system supports up to six (STD), high performance silver grade (HPR (Silver)), or high performance gold grade (HPR (Gold)) cooling fans.
| Fan type | Abbreviation | Also known as | Label color | Label image |
|---|---|---|---|---|
| Standard fan | STD | STD | No label | ![]() |
| High-performance fan (Silver grade) fan | HPR (Silver) | HPR | Silver | NOTE:New cooling fans comes with the High Performance Silver Grade label. While the older cooling fans has the High Performance label.
![]() ![]() |
| High-performance fan (Gold grade) fan | HPR (Gold) | VHP - Very High Performance | Gold | NOTE:New cooling fans comes with the High Performance Gold Grade label. While the older cooling fans has the High Performance label.
![]() ![]() |
System battery specifications
The PowerEdge R7525 system supports CR 2032 3.0-V lithium coin cell system battery.
Expansion card riser specifications
| PCIe slot | With Regular shroud | PCIe slot length | R1a | R1b | R1c | R2a | R3a | R3b | R4a | R4b | R4c |
|---|---|---|---|---|---|---|---|---|---|---|---|
| Slot 1 | Low profile and Full Height- Half Length | Low profile and Full Height- Half Length | x8 | x16 | |||||||
| Slot 2 | Low profile and Full Height- Half Length | Full Height-3/4 and Full Length | x16(GPU) | x8 | x16 | ||||||
| Slot 3 | Low profile-Half Length | x16 | |||||||||
| Slot 4 | Low profile and Full Height- Half Length | x8 | |||||||||
| Slot 5 | Low profile and Full Height- Half Length | Full Height-3/4 and Full Length | x16(GPU) | x8 | |||||||
| Slot 6 | Low profile-Half Length | x16 | |||||||||
| Slot 7 | Low profile and Full Height- Half Length | Full Height-3/4 and Full Length | x16(GPU) | x8 | x16 | ||||||
| Slot 8 | Low profile and Full Height- Half Length | Low profile and Full Height- Half Length | x8 | x16 |
Memory specifications
| DIMM type | Rank | Capacity | DIMM rated voltage and speed | Operating Speed on AMD EPYC™ processor | |
|---|---|---|---|---|---|
| 1 DIMM per channel (1DPC) | 2 DIMMs per channel (2DPC) | ||||
| RDIMM | 1R | 8 GB | DDR4 (1.2V), 3200 MT/s | 3200 MT/s | 2933 MT/s |
| 2R | 16 GB, 32 GB, 64 GB | DDR4 (1.2V), 3200 MT/s | 3200 MT/s | 2933 MT/s | |
| LRDIMM | 4 R | 128 GB | DDR4 (1.2 V), 3200 MT/s | 3200 MT/s | 2933 MT/s |
| 8R | 128 GB | DDR4 (1.2V), 2666 MT/s | 2666 MT/s | 2666 MT/s | |
| 8R | 128 GB | DDR4 (1.2V), 3200 MT/s | 3200 MT/s | 2933 MT/s | |
| Memory module sockets | Speed |
|---|---|
| 32, 288-pin | 3200 MT/s, 2933 MT/s, 2666 MT/s |
Storage controller specifications
| Internal controllers | External controllers |
|---|---|
|
|
| Front PERC | Adapter PERC |
|---|---|
| 8 x 3.5 inches SAS/SATA | 12 x 3.5 inches SAS/SATA |
| 16 x 2.5 inches SAS/SATA | 12 x 3.5 inches + Rear 2 x 2.5 inches |
| 24 x 2.5 inches (16 SAS/SATA X 2.5 inches + 8 X 2.5 inches NVME) | 12 x 3.5 inches + Rear 2 x 2.5 inches NVME |
| 8 x 2.5 inches NVMe | 16 x 2.5 inches SAS/SATA |
Drives
- 8 x 3.5-inch hot-swappable SAS, SATA drives.
- 8 x 2.5 inch NVMe drives.
- 12 x 3.5-inch hot-swappable SAS, SATA drives.
- 16 x 2.5-inch hot-swappable SAS, SATA drives.
- 24 x 2.5-inch hot-swappable SAS, SATA , or NVMe drives.
Backplane
- Up to 8 x 3.5-inch SAS, SATA drives.
- Up to 8 x 2.5 inch NVMe drives.
- Up to 12 x 3.5-inch SAS, SATA drives.
- Up to 16 x 2.5-inch SAS, SATA drives.
- Up to 24 x 2.5-inch NVMe drives.
- Up to 2 x 2.5-inch rear SAS, SATA, or NVMe drives
USB ports specifications
| Front | Rear | Internal (Optional) | |||
|---|---|---|---|---|---|
| USB port type | No. of ports | USB port type | No. of ports | USB port type | No. of ports |
| USB 2.0-compliant port | One | USB 3.0-compliant ports | One | Internal USB 3.0-compliant port | One |
| Micro-USB 2.0 compliant port | One | USB 2.0-compliant ports | One | ||
NIC port specifications
| Feature | Specifications |
|---|---|
| LOM card | 1 GB x 2 |
| OCP card (OCP 3.0) | 1 GbE x 4, 10 GbE x 2, 25 GbE x 2, 25 GbE x 4, 50 GbE x 2, 100 GbE x 2 |
Serial connector specifications
The PowerEdge R7525 system supports one optional card type serial connector, which is a 9-pin connector, Data Terminal Equipment (DTE), 16550-compliant.
The optional serial connector card is installed similar to an expansion card filler bracket.
VGA ports specifications
The PowerEdge R7525 system supports two DB-15 VGA port one each on the front and back panels.
IDSDM
The IDSDM supports two SD cards and is available in the following configurations:
| IDSDM card |
|---|
|
Video specifications
| Resolution | Refresh rate (Hz) | Color depth (bits) |
|---|---|---|
| 1024 x 768 | 60 | 8, 16, 32 |
| 1280 x 800 | 60 | 8, 16, 32 |
| 1280 x 1024 | 60 | 8, 16, 32 |
| 1360 x 768 | 60 | 8, 16, 32 |
| 1440 x 900 | 60 | 8, 16, 32 |
| Resolution | Refresh rate (Hz) | Color depth (bits) |
|---|---|---|
| 1024 x 768 | 60 | 8, 16, 32 |
| 1280 x 800 | 60 | 8, 16, 32 |
| 1280 x 1024 | 60 | 8, 16, 32 |
| 1360 x 768 | 60 | 8, 16, 32 |
| 1440 x 900 | 60 | 8, 16, 32 |
| 1600 x 900 | 60 | 8, 16, 32 |
| 1600 x 1200 | 60 | 8, 16, 32 |
| 1680 x 1050 | 60 | 8, 16, 32 |
| 1920 x 1080 | 60 | 8, 16, 32 |
| 1920 x 1200 | 60 | 8, 16, 32 |
Environmental specifications
| Temperature | Specifications |
|---|---|
| Allowable continuous operations | |
| Temperature ranges for altitudes <= 900 m (<= 2953 ft) | 10–35°C (50–95°F) with no direct sunlight on the equipment |
| Humidity percent ranges (non-condensing at all times) | 8% RH with -12°C minimum dew point to 80% RH with 21°C (69.8°F) maximum dew point |
| Operational altitude de-rating | Maximum temperature is reduced by 1°C/300 m (33.8°F/984 Ft) above 900 m (2953 Ft) |
| Temperature | Specifications |
|---|---|
| Allowable continuous operations | |
| Temperature ranges for altitudes <= 900 m (<= 2953 ft) | 5–40°C (41–104°F) with no direct sunlight on the equipment |
| Humidity percent ranges (non-condensing at all times) | 8% RH with -12°C minimum dew point to 85% RH with 24°C (75.2°F) maximum dew point |
| Operational altitude de-rating | Maximum temperature is reduced by 1°C/175 m (33.8°F/574 Ft) above 900 m (2953 Ft) |
| Temperature | Specifications |
|---|---|
| Allowable continuous operations | |
| Temperature ranges for altitudes <= 900 m (<= 2953 ft) | 5–45°C (41–113°F) with no direct sunlight on the equipment |
| Humidity percent ranges (non-condensing at all times) | 8% RH with -12°C minimum dew point to 90% RH with 24°C (75.2°F) maximum dew point |
| Operational altitude de-rating | Maximum temperature is reduced by 1°C/125 m (33.8°F/410 Ft) above 900 m (2953 Ft) |
| Temperature | Specifications |
|---|---|
| Allowable continuous operations | |
| Maximum temperature gradient (applies to both operation and non-operation) | 20°C in an hour* (36°F in an hour) and 5°C in 15 minutes (41°F in 15 minutes), 5°C in an hour* (41°F in an hour) for tape
NOTE:* - Per ASHRAE thermal guidelines for tape hardware, these are not instantaneous rates of temperature change.
|
| Non-operational temperature limits | -40 to 65°C (-104 to 149°F) |
| Non-operational humidity limits | 5% to 95% RH with 27°C (80.6°F) maximum dew point |
| Maximum non-operational altitude | 12,000 meters (39,370 feet) |
| Maximum operational altitude | 3,048 meters (10,000 feet) |
| Maximum vibration | Specifications |
|---|---|
| Operating | 0.26 Grms at 5 Hz to 350 Hz (all operation orientations) |
| Storage | 1.88 Grms at 10 Hz to 500 Hz for 15 minutes (all six sides tested) |
| Maximum shock pulse | Specifications |
|---|---|
| Operating | Six consecutively executed shock pulses in the positive and negative x, y, and z axis of 6 G for up to 11 ms. |
| Storage | Six consecutively executed shock pulses in the positive and negative x, y, and z axis (one pulse on each side of the system) of 71 G for up to 2 ms. |
Thermal air restrictions
Fresh air environment
- Two PSUs are required in redundant mode, however single PSU failure is not supported.
- NVMe drive is not supported.
- 128 GB or greater capacity DIMMs are not supported.
- Both SW and DW GPGPU/FPGA are not supported.
- CPU TDP equal or greater than 180 W are not supported.
- Rear drives are not supported.
- PCIe card TDP more than 25 W is not supported
ASHRAE A3 environment
- Two PSUs are required in redundant mode, however single PSU failure is not supported.
- NVMe drive is not supported.
- 128 GB or greater capacity DIMMs are not supported.
- Both SW and DW GPGPU/FPGA are not supported.
- CPU TDP equal or greater than 180 W are not supported.
- Rear drives are not supported.
- PCIe card TDP more than 25 W is not supported.
ASHRAE A4 environment
- Two PSUs are required in redundant mode, however single PSU failure is not supported.
- NVMe drive is not supported.
- 128 GB or greater capacity DIMMs are not supported.
- CPU TDP equal or greater than 155 W are not supported (Only 120 W processor supports A4).
- Rear drives are not supported.
- 12 x 3.5-inch chassis is not supported.
- BOSS and OCP are not supported.
- PCIe card TDP more than 25 W is not supported.
Liquid cooling: Fresh air environment
- Two PSUs are required in redundant mode. Single PSU failure is not supported.
- NVMe drive is not supported.
- 256 GB and higher capacity DIMM is not supported.
- Both SW and DW GPGPU/FPGA are not supported.
- Rear drive configuration is not supported.
- PCIe card TDP more than 25 W is not supported.
Liquid cooling: ASHRAE A3 environment
- Two PSUs are required in redundant mode, however single PSU failure is not supported.
- NVMe drive is not supported.
- 256 GB and higher capacity DIMM is not supported.
- Both SW and DW GPGPU/FPGA are not supported.
- Rear drive configuration is not supported.
- PCIe card TDP more than 25 W is not supported.
Liquid cooling: ASHRAE A4 environment
- Two PSUs are required in redundant mode, however single PSU failure is not supported.
- NVMe drive is not supported.
- 256 GB and higher capacity DIMM is not supported.
- Both SW and DW GPGPU/FPGA are not supported.
- Rear drive configuration is not supported.
- PCIe card TDP more than 25 W is not supported.
Thermal restriction matrix
| Configuration | 8 x 2.5-inch NVMe | 16 x 2.5-inch SAS | 16 x 2.5-inch NVMe | 24 x 2.5-inch SAS | 16 x 2.5-inch SAS + 8 x 2.5-inch NVMe | 24 x 2.5-inch NVMe | 8 x 3.5-inch | 12 x 3.5-inch | Ambient temperature | |||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Rear storage | No Rear Drives | No Rear Drives | No Rear Drives | No Rear Drives | 2 x Rear 2.5-inch No Rear Fan | 4 x Rear 2.5-inch with Rear Fan | No Rear Drives | No Rear Drives | No Rear Drives | No Rear Drives | 2 x Rear 2.5-inch No Rear Fan | 4 x Rear 2.5-inch with Rear Fan | ||
| CPU TDP/cTDP | 120 W | STD fan
1U STD HSK |
STD fan
1U STD HSK |
STD fan
1U STD HSK |
STD fan
1U STD HSK |
HPR fan
1U STD HSK |
HPR fan
1U STD HSK |
STD fan
1U STD HSK |
HPR fan
1U STD HSK |
STD fan
1U STD HSK |
HPR fan
1U STD HSK |
HPR fan
1U STD HSK |
HPR fan
1U STD HSK |
35°C |
| 155 W | STD fan
1U STD HSK |
STD fan
1U STD HSK |
STD fan
1U STD HSK |
STD fan
1U STD HSK |
HPR fan
1U STD HSK |
HPR fan
1U STD HSK |
STD fan
1U STD HSK |
HPR fan
1U STD HSK |
STD fan
1U STD HSK |
HPR fan
1U STD HSK |
HPR fan
1U STD HSK |
HPR fan
1U STD HSK |
35°C | |
| 170 W | STD fan
1U STD HSK |
STD fan
1U STD HSK |
STD fan
1U STD HSK |
STD fan
1U STD HSK |
HPR fan
1U STD HSK |
HPR fan
1U STD HSK |
STD fan
1U STD HSK |
HPR fan
1U STD HSK |
STD fan
1U STD HSK |
HPR fan
1U STD HSK |
HPR fan
1U STD HSK |
HPR fan
1U STD HSK |
35°C | |
| 180 W | STD fan
2U Full HSK |
STD fan
2U Full HSK |
STD fan
2U Full HSK |
STD fan
2U Full HSK |
HPR fan
2U Full HSK |
HPR fan
2U Full HSK |
STD fan
2U Full HSK |
HPR fan
2U Full HSK |
STD fan
2U Full HSK |
HPR fan
2U Full HSK |
HPR fan
2U Full HSK |
HPR fan
2U Full HSK |
35°C | |
| 200 W | STD fan
2U Full HSK |
STD fan
2U Full HSK |
STD fan
2U Full HSK |
STD fan
2U Full HSK |
HPR fan
2U Full HSK |
HPR fan
2U Full HSK |
STD fan
2U Full HSK |
HPR fan
2U Full HSK |
STD fan
2U Full HSK |
HPR fan
2U Full HSK |
HPR fan
2U Full HSK |
HPR fan
2U Full HSK |
35°C | |
| 225 W | STD fan
2U Full HSK |
STD fan
2U Full HSK |
STD fan
2U Full HSK |
STD fan
2U Full HSK |
HPR fan
2U Full HSK |
HPR fan
2U Full HSK |
STD fan
2U Full HSK |
HPR fan
2U Full HSK |
STD fan
2U Full HSK |
HPR fan
2U Full HSK |
HPR fan
2U Full HSK |
HPR fan
2U Full HSK |
35°C | |
| 240 W | STD fan
2U Full HSK |
STD fan
2U Full HSK |
STD fan
2U Full HSK |
STD fan
2U Full HSK |
HPR fan
2U Full HSK |
HPR fan
2U Full HSK |
STD fan
2U Full HSK |
HPR fan
2U Full HSK |
STD fan
2U Full HSK |
HPR fan
2U Full HSK |
HPR fan
2U Full HSK |
HPR fan
2U Full HSK |
35°C | |
| 280 W - 64C | STD fan
2U Full HSK |
STD fan
2U Full HSK |
STD fan
2U Full HSK |
STD fan*
2U Full HSK |
HPR fan
2U Full HSK |
VHP fan
2U Full HSK |
STD fan*
2U Full HSK |
HPR fan*
2U Full HSK |
STD fan
2U Full HSK |
HPR fan*
2U Full HSK |
HPR fan*
2U Full HSK |
HPR fan*
2U Full HSK |
35°C | |
| 280 W - 32C | STD fan
2U Full HSK |
STD fan
2U Full HSK |
STD fan
2U Full HSK |
STD fan*
2U Full HSK |
HPR fan
2U Full HSK |
VHP fan
2U Full HSK |
STD fan*
2U Full HSK |
HPR fan*
2U Full HSK |
STD fan
2U Full HSK |
- | - | - | 35°C | |
| 280 W - 64C/32C | STD fan
2U Full HSK |
STD fan
2U Full HSK |
STD fan
2U Full HSK |
STD fan*
2U Full HSK |
HPR fan
2U Full HSK |
VHP fan
2U Full HSK |
STD fan*
2U Full HSK |
HPR fan*
2U Full HSK |
STD fan
2U Full HSK |
- | - | - | 35°C | |
| 280 W - 24C/16C | VHP fan
2U Full HSK |
VHP fan
2U Full HSK |
VHP fan
2U Full HSK |
|||||||||||
| 128 GB LRDIMM | - | STD fan | STD fan | STD fan | STD fan | HPR (Silver) fan | HPR (Silver) fan | STD fan | HPR (Silver) fan | STD fan | HPR (Silver) fan*, if TDP ≥ 200 W | HPR (Silver) fan*, if TDP ≥ 170 W | HPR (Silver) fan* | 35°C |
| Configuration (Front storage) | Fan type | Max CPU TDP/cTDP | GPU/FPGA ( Ambient temperature ) | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| T4 | V100 (16 GB) | V100S | M10 | Snow white | RTX 6000 | RTX8000 | A100 | MI100 | A40 | A10 | A30 | A16 | MI210 | A2 | |||
| No Backpane | HPR (Silver) | 280 W | 30°C | 35°C | 30°C | 35°C | 35°C | 35°C | 35°C | 35°C | 30°C | 30°C | 30°C | 35°C | 35°C | 35°C | 30°C |
| 8 x 2.5-inch NVMe | HPR (Silver) | 280 W | 30°C | 35°C | 30°C | 35°C | 35°C | 35°C | 35°C | 35°C | 30°C | 30°C | 30°C | 35°C | 35°C | 35°C | 30°C |
| 16 x 2.5-inch SAS | HPR (Silver) | 280 W | 30°C | 35°C | 30°C | 35°C | 35°C | 35°C | 35°C | 35°C | 30°C | 30°C | 30°C | 35°C | 35°C | 35°C | 30°C |
| 16 x 2.5-inch NVMe | HPR (Gold) | 280 W | 30°C | 35°C | 30°C | 35°C | 35°C | 35°C | 35°C | 35°C | 30°C | 30°C | 30°C | 35°C | 35°C | 35°C | 30°C |
| 16 x 2.5-inch SAS + 8 x 2.5-inch NVMe | HPR (Gold) | 280 W | 30°C | 35°C | 30°C | 35°C | 35°C | 35°C | 35°C | 35°C | 30°C | 30°C | 30°C | 35°C | 35°C | 35°C | 30°C |
| 8 x 3.5-inch SAS | HPR (Silver) | 280 W | 30°C | 35°C | 30°C | 35°C | 35°C | 35°C | 35°C | 35°C | 30°C | 30°C | 30°C | 35°C | 35°C | 35°C | 30°C |
| Heat sink | Processor TDP |
|---|---|
| STD HSK | < 180 W |
| 2U HPR (Silver) HSK | >= 180 W |
| L-type HSK | Supports all TDP (system should be installed with GPU/FGPA/long PCIe cards) |
| Label | Description |
|---|---|
| STD | Standard |
| HPR (Silver) | High performance (silver grade) |
| HPR (Gold) | High performance (gold grade) |
| HSK | Heat sink |
| LP | Low profile |
| FH | Full height |
| Configuration | 8 x 2.5-inch NVMe | 16 x 2.5-inch SAS | 16 x 2.5-inch NVMe | 16 x 2.5-inch SAS + 8 x 2.5-inch NVMe | 24 x 2.5-inch NVMe | 8 x 3.5-inch | 12 x 3.5-inch | ||
|---|---|---|---|---|---|---|---|---|---|
| Rear storage | No Rear Drives | No Rear Drives | No Rear Drives | No Rear Drives | No Rear Drives | No Rear Drives | No Rear Drives | 2 x rear 2.5-inch, No rear fan | |
| CPU TDP/cTDP | 120 W | STD fan | STD fan (A4 support) | STD fan | STD fan | STD fan | STD fan (A4 support) | STD fan (A4 support) | STD fan (A3 support) |
| 155 W | STD fan | STD fan (A4 support) | STD fan | STD fan | STD fan | STD fan (A4 support) | STD fan (A4 support) | STD fan (A3 support) | |
| 170 W | STD fan | STD fan (A4 support) | STD fan | STD fan | STD fan | STD fan (A4 support) | STD fan (A4 support) | STD fan (A3 support) | |
| 180 W | STD fan | STD fan (A4 support) | STD fan | STD fan | STD fan | STD fan (A4 support) | STD fan (A4 support) | STD fan (A3 support) | |
| 200 W | STD fan | STD fan (A4 support) | STD fan | STD fan | STD fan | STD fan (A4 support) | STD fan (A4 support) | STD fan (A3 support) | |
| 225 W | STD fan | STD fan (A4 support) | STD fan | STD fan | STD fan | STD fan (A4 support) | STD fan (A4 support) | STD fan (A3 support) | |
| 240 W | STD fan | STD fan (A4 support) | STD fan | STD fan | STD fan | STD fan (A4 support) | STD fan (A4 support) | STD fan (A3 support) | |
| 280 W | STD fan | STD fan (A4 support) | STD fan | STD fan | STD fan | STD fan (A4 support) | STD fan (A4 support) | STD fan (A3 support) | |
| Configuration | 1 DPC | 2 DPC | 8 x 2.5-inch NVMe | 16 x 2.5-inch SAS | 16 x 2.5-inch NVMe | 16 x 2.5-inch SAS + 8 x 2.5-inch NVMe | 24 x 2.5-inch NVMe | 8 x 3.5-inch | 12 x 3.5-inch | ||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Rear storage | No Rear Drives | No Rear Drives | No Rear Drives | No Rear Drives | No Rear Drives | No Rear Drives | No Rear Drives | 2 x rear 2.5-inch, No rear fan | |||
| Memory | 8 GB RDIMM 3200 | 2.8 | 2.0 | STD fan | STD fan (A4 support) | STD fan | STD fan | STD fan | STD fan (A4 support) | STD fan (A4 support) | STD fan (A3 support) |
| 16 GB RDIMM 3200 | 4.3 | 3.0 | STD fan | STD fan (A4 support) | STD fan | STD fan | STD fan | STD fan (A4 support) | STD fan (A4 support) | STD fan (A3 support) | |
| 32 GB RDIMM 3200 | 6.9 | 4.8 | STD fan | STD fan (A4 support) | STD fan | STD fan | STD fan | STD fan (A4 support) | STD fan (A4 support) | STD fan (A3 support) | |
| 64 GB RDIMM 3200 | 8.3 | 5.8 | STD fan | STD fan (A4 support) | STD fan | STD fan | STD fan | STD fan (A4 support) | STD fan (A4 support) | STD fan (A3 support) | |
| 128 GB LRDIMM 2666 | 12.4 | 9.9 | STD fan | STD fan (A3 support) | STD fan | STD fan | STD fan | STD fan (A3 support) | STD fan (A3 support) | STD fan (A3 support) | |
Particulate and gaseous contamination specifications
The following table defines the limitations that help avoid any equipment damage or failure from particulates and gaseous contamination. If the levels of particulates or gaseous pollution exceed the specified limitations and result in equipment damage or failure, you must rectify the environmental conditions. Remediation of environmental conditions is the responsibility of the customer.
| Particulate contamination | Specifications |
|---|---|
| Air filtration: Conventional Data Center only | Data center air filtration as defined by ISO Class 8 per ISO 14644-1 with a 95% upper confidence limit
NOTE: Filtering room air with a MERV8 filter, as specified in ANSI/ASHRAE Standard 127, is a recommended method for achieving the necessary environmental conditions.
NOTE:Air entering the data center must have MERV11 or MERV13 filtration.
NOTE:This condition applies to data center environments only. Air filtration requirements do not apply to IT equipment designed to be used outside a data center, in environments such as an office or factory floor.
|
| Walk-Up Edge Data Center or Cabinet (sealed, closed loop environment) | Filtration is not required for cabinets that are anticipated to be opened six times or less per year. Class 8 per ISO 1466-1 filtration as defined above is required otherwise.
NOTE: In environments commonly above ISA-71 Class G1 or that may have known challenges, special filters may be required.
|
| Conductive dust: data center and non-data center environments | Air must be free of conductive dust, zinc whiskers, or other conductive particles.
NOTE: Conductive dust, which can interfere with equipment operation, can originate from various sources, including manufacturing processes and zinc whiskers that may develop on the plating of raised floor tiles.
NOTE:This condition applies to data center and non-data center environments.
|
| Corrosive dust: data center and non-data center environments |
NOTE:This condition applies to data center and non-data center environments.
|
| Gaseous contamination | Specifications | Notes |
|---|---|---|
| Copper coupon corrosion rate | ISA-71 Class G1: <300 Å/month | Per ANSI/ISA71.04 |
| Silver coupon corrosion rate | ISA-71 Class G1: <200 Å/month | Per ANSI/ISA71.04 |