Dell EMC PowerEdge R7525: технические характеристики и спецификации

Chassis dimensions

Figure 1. Chassis dimensions
This image shows chassis dimension for the PowerEge R7525 system.
Table 1. PowerEdgeR7525This table provides the dimensions of the PowerEdgeR7525 system:
Drives Xa Xb Y Za Zb Zc
12 drives 482.0 mm

(18.97 inches)

434.0 mm

(17.08 inches)

86.8 mm

(3.41 inches)

With bezel: 35.84 mm (1.4 inches)

Without bezel: 22.0 mm (0.87 inches)

700.7 mm

(27.58 inches)

(Ear to rear wall)
736.29 mm

(28.98 inches)

(Ear to PSU handle)
24 drives 482.0 mm

(18.97 inches)

434.0 mm

(17.08 inches)

86.8 mm

(3.41 inches)

With bezel: 35.84 mm (1.4 inches)

Without bezel: 22.0 mm (0.87 inches)

700.7 mm

(27.58 inches)

(Ear to rear wall)
736.29 mm

(28.98 inches)

(Ear to PSU handle)
NOTE:Zb is the nominal rear wall external surface where the system board I/O connectors reside.

Chassis weight

Table 1. PowerEdge R7525The table below shows the maximum weight of the PowerEdge R7525.
System configuration Maximum weight (with all drives/SSDs)
12 x 3.5-inch 36.3 kg (80.02 lb)
8 x 3.5-inch 33.2 kg (73.19 lb)
24 x 2.5-inch 28.6 kg (63.05 lb)
16 x 2.5-inch 26.6 kg (58.64 lb)
8 x 2.5-inch 24.6 kg (54.23 lb)

Processor specifications

Table 1. PowerEdge R7525 processor specifications This table provides processor specifications for the PowerEdge R7525
Supported processor Number of processors supported
AMD EPYC 7002 or 7003 series processor Two

PSU specifications

The PowerEdge R7525 system supports up to two AC or DC power supply units (PSUs).

WARNING:Instructions for the qualified electricians only:

System using -(48-60) V DC or 240 V DC power supplies are intended for restricted access locations in accordance with Articles 110-5, 110-6, 110-11, 110-14, and 110-17 of the National Electrical Code, American National Standards Institute (ANSI)/National Fire Protection Association (NFPA) 70.

240 V DC power supplies shall be connected to the 240 V DC outlet from certified power distribution units if applicable in country of use.

Power supply cords/jumper cords and the associated plugs/inlets/connectors shall have appropriate electrical ratings referencing the rating label on the system when used for connection.

Table 1. PowerEdge R7525 PSU specificationsThis table describes PSU specifications.
PSU Class (AC only) Heat dissipation (maximum) Frequency Voltage Current
800 W Mixed Mode Platinum 3000 BTU/hr 50/60 Hz 100 -240 V AC 9.2 - 4.7 A
N/A DC 240 V DC 3.8 A
1100 W Mixed Mode Titanium 4100 BTU/hr 50/60 Hz 100–240 V AC 12 A-6.3 A (X2)
N/A DC 240 V DC 5.2 A DC
1100 W (-48Vdc) N/A 4265 BTU/hr DC (-48)-(-60) V DC 27 A
1400 W Mixed Mode Platinum 5250 BTU/hr 50/60 Hz 100 - 240 V AC 12 - 8 A AC
N/A DC 240 V DC 6.6 A DC
2400W Mixed Mode Platinum 9000 BTU/hr 50/60 Hz 100 - 240 V AC 13.5 - 11 A AC
N/A DC 240 V DC 11.2 A DC
NOTE:If a system with AC 1400 W PSU operate at low line 100-120 V AC, then the power rating per PSU is derated to 1050 W.
NOTE: : If a system with AC 2400 W PSU operate at low line 100-120 V AC, then the power rating per PSU is derated to 1400 W.
NOTE:When selecting or upgrading the system configuration, to ensure optimum power utilization, verify the system power consumption with the Dell Energy Smart Solution Advisor available at Dell.com/ESSA.

Supported operating systems

The PowerEdge R7525 supports the following operating systems:

  • Canonical Ubuntu Server LTS
  • Citrix XenServer
  • Microsoft Windows Server with Hyper-V
  • Red Hat Enterprise Linux
  • SUSE Linux Enterprise Server
  • VMware vSAN/ESXi
For more information, see www.dell.com/ossupport.

Cooling fan specifications

The PowerEdgeR7525 system supports up to six (STD), high performance silver grade (HPR (Silver)), or high performance gold grade (HPR (Gold)) cooling fans.

Table 1. Cooling fan specificationsCooling fan specifications
Fan type Abbreviation Also known as Label color Label image
Standard fan STD STD No label This shows the Standard fan image.
High-performance fan (Silver grade) fanHPR (Silver) HPR Silver
NOTE:New cooling fans comes with the High Performance Silver Grade label. While the older cooling fans has the High Performance label.
Figure 1. High performance fan
High performance fan
Figure 2. High performance (Silver grade) fan
High performance (Silver grade) fan
High-performance fan (Gold grade) fanHPR (Gold) VHP - Very High Performance Gold
NOTE:New cooling fans comes with the High Performance Gold Grade label. While the older cooling fans has the High Performance label.
Figure 3. Very high performance fan
Very high performance fan
Figure 4. High performance (Gold grade) fan
High performance (Gold grade) fan
NOTE:Mixing of STD, HPR (Silver), or HPR (Gold) fan is not supported.
NOTE:The STD, HPR (Silver), or HPR (Gold) fan installation depends on the system configuration. For more information about the supported fan configuration or matrix, see Thermal restriction matrix.

System battery specifications

The PowerEdge R7525 system supports CR 2032 3.0-V lithium coin cell system battery.

Expansion card riser specifications

WARNING: Consumer-Grade GPU should not be installed or used in the Enterprise Server products.
The PowerEdge R7525 system supports up to eight PCI express (PCIe) Gen 4 expansion cards.
Table 1. Expansion card slots supported on the system boardThis table provides information about the expansion card slots that are supported on the PowerEdge R7525 system.
PCIe slot With Regular shroud PCIe slot length R1a R1b R1c R2a R3a R3b R4a R4b R4c
Slot 1 Low profile and Full Height- Half Length Low profile and Full Height- Half Length x8 x16
Slot 2 Low profile and Full Height- Half Length Full Height-3/4 and Full Length x16(GPU) x8 x16
Slot 3 Low profile-Half Length x16
Slot 4 Low profile and Full Height- Half Length x8
Slot 5 Low profile and Full Height- Half Length Full Height-3/4 and Full Length x16(GPU) x8
Slot 6 Low profile-Half Length x16
Slot 7 Low profile and Full Height- Half Length Full Height-3/4 and Full Length x16(GPU) x8 x16
Slot 8 Low profile and Full Height- Half Length Low profile and Full Height- Half Length x8 x16

Memory specifications

The PowerEdge R7525 system supports the following memory specifications for optimized operation.
Table 1. Memory specificationsThe table below shows the memory specifications for the PowerEdge PowerEdge R7525 system:
DIMM type Rank Capacity DIMM rated voltage and speed Operating Speed on AMD EPYC™ processor
1 DIMM per channel (1DPC) 2 DIMMs per channel (2DPC)
RDIMM 1R 8 GB DDR4 (1.2V), 3200 MT/s 3200 MT/s 2933 MT/s
2R 16 GB, 32 GB, 64 GB DDR4 (1.2V), 3200 MT/s 3200 MT/s 2933 MT/s
LRDIMM 4 R 128 GB DDR4 (1.2 V), 3200 MT/s 3200 MT/s 2933 MT/s
8R 128 GB DDR4 (1.2V), 2666 MT/s 2666 MT/s 2666 MT/s
8R 128 GB DDR4 (1.2V), 3200 MT/s 3200 MT/s 2933 MT/s
NOTE:The older 32 GB capacity RDIMM memory with x4 data width and 8Gb DRAM density cannot be mixed with the newer 32GB capacity RDIMM memory with x8 data width and 16Gb DRAM density in the same AMD EPYC™ processor unit.
NOTE:The older 128 GB capacity LRDIMM memory at 2666 MT/s speed cannot be mixed with the new 128 GB capacity LRDIMM memory at 3200 MT/s speed.
Table 2. Memory module socketsThe table below shows the memory module sockets for the PowerEdge R7525 system:
Memory module sockets Speed
32, 288-pin 3200 MT/s, 2933 MT/s, 2666 MT/s

Storage controller specifications

The PowerEdge R7525 system supports the following controller cards:
Table 1. PowerEdge R7525 system controller cardsThis table provides the controller cards supported on PowerEdge R7525 system:
Internal controllers External controllers
  • PERC H755
  • PERC H755N
  • PERC H745
  • PERC H345
  • HBA345
  • HBA355
  • S150
  • Boot Optimized Storage Subsystem (BOSS-S1): HWRAID 2 x M.2 SSDs
  • Boot Optimized Storage Subsystem (BOSS-S2): HWRAID 2 x M.2 SSDs
  • 12Gbps SAS Ext. HBA
  • PERC H840
  • HBA355E
Table 2. PowerEdge R7525 Front PERC and Adapter PERC support on back planes This table provides information on Front PERC and Adapter PERC on different back planes supported on PowerEdge R7525 system:
Front PERC Adapter PERC
8 x 3.5 inches SAS/SATA 12 x 3.5 inches SAS/SATA
16 x 2.5 inches SAS/SATA 12 x 3.5 inches + Rear 2 x 2.5 inches
24 x 2.5 inches (16 SAS/SATA X 2.5 inches + 8 X 2.5 inches NVME) 12 x 3.5 inches + Rear 2 x 2.5 inches NVME
8 x 2.5 inches NVMe 16 x 2.5 inches SAS/SATA

Drives

The PowerEdge R7525 system supports:
  • 8 x 3.5-inch hot-swappable SAS, SATA drives.
  • 8 x 2.5 inch NVMe drives.
  • 12 x 3.5-inch hot-swappable SAS, SATA drives.
  • 16 x 2.5-inch hot-swappable SAS, SATA drives.
  • 24 x 2.5-inch hot-swappable SAS, SATA , or NVMe drives.

Backplane

  • Up to 8 x 3.5-inch SAS, SATA drives.
  • Up to 8 x 2.5 inch NVMe drives.
  • Up to 12 x 3.5-inch SAS, SATA drives.
  • Up to 16 x 2.5-inch SAS, SATA drives.
  • Up to 24 x 2.5-inch NVMe drives.
  • Up to 2 x 2.5-inch rear SAS, SATA, or NVMe drives
NOTE: For more information about how to hot swap NVMe PCIe SSD U.2 device, see the Dell Express Flash NVMe PCIe SSD User's Guide at https://www.dell.com/support Browse all Products > Data Center Infrastructure >  Storage Adapters & Controllers > Dell PowerEdge Express Flash NVMe PCIe SSD > Documentation > Manuals and Documents.

USB ports specifications

Table 1. PowerEdge R7525 system USB specificationsThe following table shows the USB specifications for the PowerEdge R7525 system.
Front Rear Internal (Optional)
USB port type No. of ports USB port type No. of ports USB port type No. of ports
USB 2.0-compliant port One USB 3.0-compliant ports One Internal USB 3.0-compliant port One
Micro-USB 2.0 compliant port One USB 2.0-compliant ports One
NOTE:The micro USB 2.0 compliant port can only be used as an iDRAC Direct or a management port.
NOTE:The USB 2.0 specifications provide a 5 V supply on a single wire to power connected USB devices. A unit load is defined as 100 mA in USB 2.0, and 150 mA in USB 3.0. A device may draw a maximum of 5 unit loads (500 mA) from a port in USB 2.0; 6 (900 mA) in USB 3.0.
NOTE:The USB 2.0 interface can provide power to low-power peripherals but must adhere to USB specification. An external power source is required for higher-power peripherals to function, such as external CD/DVD Drives.

NIC port specifications

The PowerEdge R7525 system supports up to two 10/100/1000 Mbps Network Interface Controller (NIC) ports embedded on the LAN on Motherboard (LOM) and integrated on the optional OCP cards.
Table 1. NIC port specification This table describes the NIC port specification.
Feature Specifications
LOM card 1 GB x 2
OCP card (OCP 3.0) 1 GbE x 4, 10 GbE x 2, 25 GbE x 2, 25 GbE x 4, 50 GbE x 2, 100 GbE x 2

Serial connector specifications

The PowerEdge R7525 system supports one optional card type serial connector, which is a 9-pin connector, Data Terminal Equipment (DTE), 16550-compliant.

The optional serial connector card is installed similar to an expansion card filler bracket.

VGA ports specifications

The PowerEdge R7525 system supports two DB-15 VGA port one each on the front and back panels.

IDSDM

The PowerEdge R7525 system supports Internal Dual SD module (IDSDM).

The IDSDM supports two SD cards and is available in the following configurations:

Table 1. Supported SD card storage capacityThis table lists the storage capacity of the supported SD cards
IDSDM card
  • 16 GB
  • 32 GB
  • 64 GB
NOTE:One IDSDM card slot is dedicated for redundancy.
NOTE:Use Dell EMC branded SD cards that are associated with the IDSDM configured systems.

Video specifications

The PowerEdge R7525 system supports integrated Matrox G200 graphics controller with 16 MB of video frame buffer.
Table 1. Supported front video resolution optionsThis table describes the supported front video resolution options.
Resolution Refresh rate (Hz) Color depth (bits)
1024 x 768 60 8, 16, 32
1280 x 800 60 8, 16, 32
1280 x 1024 60 8, 16, 32
1360 x 768 60 8, 16, 32
1440 x 900 60 8, 16, 32
Table 2. Supported rear video resolution optionsThis table describes the supported rear video resolution options.
Resolution Refresh rate (Hz) Color depth (bits)
1024 x 768 60 8, 16, 32
1280 x 800 60 8, 16, 32
1280 x 1024 60 8, 16, 32
1360 x 768 60 8, 16, 32
1440 x 900 60 8, 16, 32
1600 x 900 60 8, 16, 32
1600 x 1200 60 8, 16, 32
1680 x 1050 60 8, 16, 32
1920 x 1080 60 8, 16, 32
1920 x 1200 60 8, 16, 32

Environmental specifications

NOTE:For additional information about environmental certifications, refer to the Product Environmental Datasheet located with the Manuals & Documents on www.dell.com/support/home.
Table 1. Operational climatic range category A2 This table describes the operational climatic range for category A2.
Temperature Specifications
Allowable continuous operations
Temperature ranges for altitudes <= 900 m (<= 2953 ft) 10–35°C (50–95°F) with no direct sunlight on the equipment
Humidity percent ranges (non-condensing at all times) 8% RH with -12°C minimum dew point to 80% RH with 21°C (69.8°F) maximum dew point
Operational altitude de-rating Maximum temperature is reduced by 1°C/300 m (33.8°F/984 Ft) above 900 m (2953 Ft)
Table 2. Operational climatic range category A3 This table describes the operational climatic range for category A3.
Temperature Specifications
Allowable continuous operations
Temperature ranges for altitudes <= 900 m (<= 2953 ft) 5–40°C (41–104°F) with no direct sunlight on the equipment
Humidity percent ranges (non-condensing at all times) 8% RH with -12°C minimum dew point to 85% RH with 24°C (75.2°F) maximum dew point
Operational altitude de-rating Maximum temperature is reduced by 1°C/175 m (33.8°F/574 Ft) above 900 m (2953 Ft)
Table 3. Operational climatic range category A4 This table describes the operational climatic range for category A4.
Temperature Specifications
Allowable continuous operations
Temperature ranges for altitudes <= 900 m (<= 2953 ft) 5–45°C (41–113°F) with no direct sunlight on the equipment
Humidity percent ranges (non-condensing at all times) 8% RH with -12°C minimum dew point to 90% RH with 24°C (75.2°F) maximum dew point
Operational altitude de-rating Maximum temperature is reduced by 1°C/125 m (33.8°F/410 Ft) above 900 m (2953 Ft)
Table 4. Shared requirements across all categories This table describes the shared requirements across all categories.
Temperature Specifications
Allowable continuous operations
Maximum temperature gradient (applies to both operation and non-operation) 20°C in an hour* (36°F in an hour) and 5°C in 15 minutes (41°F in 15 minutes), 5°C in an hour* (41°F in an hour) for tape
NOTE:* - Per ASHRAE thermal guidelines for tape hardware, these are not instantaneous rates of temperature change.
Non-operational temperature limits -40 to 65°C (-104 to 149°F)
Non-operational humidity limits 5% to 95% RH with 27°C (80.6°F) maximum dew point
Maximum non-operational altitude 12,000 meters (39,370 feet)
Maximum operational altitude 3,048 meters (10,000 feet)
Table 5. Maximum vibration specificationsThe maximum vibration specification of an operational system is 0.26 Grms at 5 Hz to 350 Hz (all operation orientations).The maximum vibration specification of a nonoperational system is 1.88 Grms at 10 Hz to 500 Hz for 15 minutes (all six sides tested).
Maximum vibration Specifications
Operating 0.26 Grms at 5 Hz to 350 Hz (all operation orientations)
Storage 1.88 Grms at 10 Hz to 500 Hz for 15 minutes (all six sides tested)
Table 6. Maximum shock pulse specificationsThe maximum shock specification of an operational system is six consecutively executed shock pulses in the positive and negative x, y, and z axis of 40 G for up to 2.3 ms. The maximum shock specification of a nonoperational system is six consecutively executed shock pulses in the positive and negative x, y, and z axis (one pulse on each side of the system) of 71 G for up to 2 ms.
Maximum shock pulse Specifications
Operating Six consecutively executed shock pulses in the positive and negative x, y, and z axis of 6 G for up to 11 ms.
Storage Six consecutively executed shock pulses in the positive and negative x, y, and z axis (one pulse on each side of the system) of 71 G for up to 2 ms.

Thermal air restrictions

Fresh air environment

  • Two PSUs are required in redundant mode, however single PSU failure is not supported.
  • NVMe drive is not supported.
  • 128 GB or greater capacity DIMMs are not supported.
  • Both SW and DW GPGPU/FPGA are not supported.
  • CPU TDP equal or greater than 180 W are not supported.
  • Rear drives are not supported.
  • PCIe card TDP more than 25 W is not supported

ASHRAE A3 environment

  • Two PSUs are required in redundant mode, however single PSU failure is not supported.
  • NVMe drive is not supported.
  • 128 GB or greater capacity DIMMs are not supported.
  • Both SW and DW GPGPU/FPGA are not supported.
  • CPU TDP equal or greater than 180 W are not supported.
  • Rear drives are not supported.
  • PCIe card TDP more than 25 W is not supported.

ASHRAE A4 environment

  • Two PSUs are required in redundant mode, however single PSU failure is not supported.
  • NVMe drive is not supported.
  • 128 GB or greater capacity DIMMs are not supported.
  • CPU TDP equal or greater than 155 W are not supported (Only 120 W processor supports A4).
  • Rear drives are not supported.
  • 12 x 3.5-inch chassis is not supported.
  • BOSS and OCP are not supported.
  • PCIe card TDP more than 25 W is not supported.

Liquid cooling: Fresh air environment

  • Two PSUs are required in redundant mode. Single PSU failure is not supported.
  • NVMe drive is not supported.
  • 256 GB and higher capacity DIMM is not supported.
  • Both SW and DW GPGPU/FPGA are not supported.
  • Rear drive configuration is not supported.
  • PCIe card TDP more than 25 W is not supported.

Liquid cooling: ASHRAE A3 environment

  • Two PSUs are required in redundant mode, however single PSU failure is not supported.
  • NVMe drive is not supported.
  • 256 GB and higher capacity DIMM is not supported.
  • Both SW and DW GPGPU/FPGA are not supported.
  • Rear drive configuration is not supported.
  • PCIe card TDP more than 25 W is not supported.

Liquid cooling: ASHRAE A4 environment

  • Two PSUs are required in redundant mode, however single PSU failure is not supported.
  • NVMe drive is not supported.
  • 256 GB and higher capacity DIMM is not supported.
  • Both SW and DW GPGPU/FPGA are not supported.
  • Rear drive configuration is not supported.
  • PCIe card TDP more than 25 W is not supported.

Thermal restriction matrix

Table 1. Thermal restriction matrixThe table describes thermal restriction matrix for the PowerEdge R7525 system.
Configuration 8 x 2.5-inch NVMe 16 x 2.5-inch SAS 16 x 2.5-inch NVMe 24 x 2.5-inch SAS 16 x 2.5-inch SAS + 8 x 2.5-inch NVMe 24 x 2.5-inch NVMe 8 x 3.5-inch 12 x 3.5-inch Ambient temperature
Rear storage No Rear Drives No Rear Drives No Rear Drives No Rear Drives 2 x Rear 2.5-inch No Rear Fan 4 x Rear 2.5-inch with Rear Fan No Rear Drives No Rear Drives No Rear Drives No Rear Drives 2 x Rear 2.5-inch No Rear Fan 4 x Rear 2.5-inch with Rear Fan
CPU TDP/cTDP 120 W STD fan

1U STD HSK

STD fan

1U STD HSK

STD fan

1U STD HSK

STD fan

1U STD HSK

HPR fan

1U STD HSK

HPR fan

1U STD HSK

STD fan

1U STD HSK

HPR fan

1U STD HSK

STD fan

1U STD HSK

HPR fan

1U STD HSK

HPR fan

1U STD HSK

HPR fan

1U STD HSK

35°C
155 W STD fan

1U STD HSK

STD fan

1U STD HSK

STD fan

1U STD HSK

STD fan

1U STD HSK

HPR fan

1U STD HSK

HPR fan

1U STD HSK

STD fan

1U STD HSK

HPR fan

1U STD HSK

STD fan

1U STD HSK

HPR fan

1U STD HSK

HPR fan

1U STD HSK

HPR fan

1U STD HSK

35°C
170 W STD fan

1U STD HSK

STD fan

1U STD HSK

STD fan

1U STD HSK

STD fan

1U STD HSK

HPR fan

1U STD HSK

HPR fan

1U STD HSK

STD fan

1U STD HSK

HPR fan

1U STD HSK

STD fan

1U STD HSK

HPR fan

1U STD HSK

HPR fan

1U STD HSK

HPR fan

1U STD HSK

35°C
180 W STD fan

2U Full HSK

STD fan

2U Full HSK

STD fan

2U Full HSK

STD fan

2U Full HSK

HPR fan

2U Full HSK

HPR fan

2U Full HSK

STD fan

2U Full HSK

HPR fan

2U Full HSK

STD fan

2U Full HSK

HPR fan

2U Full HSK

HPR fan

2U Full HSK

HPR fan

2U Full HSK

35°C
200 W STD fan

2U Full HSK

STD fan

2U Full HSK

STD fan

2U Full HSK

STD fan

2U Full HSK

HPR fan

2U Full HSK

HPR fan

2U Full HSK

STD fan

2U Full HSK

HPR fan

2U Full HSK

STD fan

2U Full HSK

HPR fan

2U Full HSK

HPR fan

2U Full HSK

HPR fan

2U Full HSK

35°C
225 W STD fan

2U Full HSK

STD fan

2U Full HSK

STD fan

2U Full HSK

STD fan

2U Full HSK

HPR fan

2U Full HSK

HPR fan

2U Full HSK

STD fan

2U Full HSK

HPR fan

2U Full HSK

STD fan

2U Full HSK

HPR fan

2U Full HSK

HPR fan

2U Full HSK

HPR fan

2U Full HSK

35°C
240 W STD fan

2U Full HSK

STD fan

2U Full HSK

STD fan

2U Full HSK

STD fan

2U Full HSK

HPR fan

2U Full HSK

HPR fan

2U Full HSK

STD fan

2U Full HSK

HPR fan

2U Full HSK

STD fan

2U Full HSK

HPR fan

2U Full HSK

HPR fan

2U Full HSK

HPR fan

2U Full HSK

35°C
280 W - 64C STD fan

2U Full HSK

STD fan

2U Full HSK

STD fan

2U Full HSK

STD fan*

2U Full HSK

HPR fan

2U Full HSK

VHP fan

2U Full HSK

STD fan*

2U Full HSK

HPR fan*

2U Full HSK

STD fan

2U Full HSK

HPR fan*

2U Full HSK

HPR fan*

2U Full HSK

HPR fan*

2U Full HSK

35°C
280 W - 32C STD fan

2U Full HSK

STD fan

2U Full HSK

STD fan

2U Full HSK

STD fan*

2U Full HSK

HPR fan

2U Full HSK

VHP fan

2U Full HSK

STD fan*

2U Full HSK

HPR fan*

2U Full HSK

STD fan

2U Full HSK

- - - 35°C
280 W - 64C/32C STD fan

2U Full HSK

STD fan

2U Full HSK

STD fan

2U Full HSK

STD fan*

2U Full HSK

HPR fan

2U Full HSK

VHP fan

2U Full HSK

STD fan*

2U Full HSK

HPR fan*

2U Full HSK

STD fan

2U Full HSK

- - - 35°C
280 W - 24C/16C VHP fan

2U Full HSK

VHP fan

2U Full HSK

VHP fan

2U Full HSK

128 GB LRDIMM - STD fan STD fan STD fan STD fan HPR (Silver) fan HPR (Silver) fan STD fan HPR (Silver) fan STD fan HPR (Silver) fan*, if TDP ≥ 200 W HPR (Silver) fan*, if TDP ≥ 170 W HPR (Silver) fan* 35°C
NOTE:* Supported ambient temperature is 30°C.
NOTE:Three fan modules are required for single processor, and six fan modules are required for dual processor system.
Table 2. Air cooling and liquid cooling: GPU/FPGA thermal restriction matrix The table describes GPU/FPGA thermal restriction matrix for the PowerEdge R7525 system.
Configuration (Front storage) Fan type Max CPU TDP/cTDP GPU/FPGA ( Ambient temperature )
T4 V100 (16 GB) V100S M10 Snow white RTX 6000 RTX8000 A100 MI100 A40 A10 A30 A16 MI210 A2
No Backpane HPR (Silver) 280 W 30°C 35°C 30°C 35°C 35°C 35°C 35°C 35°C 30°C 30°C 30°C 35°C 35°C 35°C 30°C
8 x 2.5-inch NVMe HPR (Silver) 280 W 30°C 35°C 30°C 35°C 35°C 35°C 35°C 35°C 30°C 30°C 30°C 35°C 35°C 35°C 30°C
16 x 2.5-inch SAS HPR (Silver) 280 W 30°C 35°C 30°C 35°C 35°C 35°C 35°C 35°C 30°C 30°C 30°C 35°C 35°C 35°C 30°C
16 x 2.5-inch NVMe HPR (Gold) 280 W 30°C 35°C 30°C 35°C 35°C 35°C 35°C 35°C 30°C 30°C 30°C 35°C 35°C 35°C 30°C
16 x 2.5-inch SAS + 8 x 2.5-inch NVMe HPR (Gold) 280 W 30°C 35°C 30°C 35°C 35°C 35°C 35°C 35°C 30°C 30°C 30°C 35°C 35°C 35°C 30°C
8 x 3.5-inch SAS HPR (Silver) 280 W 30°C 35°C 30°C 35°C 35°C 35°C 35°C 35°C 30°C 30°C 30°C 35°C 35°C 35°C 30°C
NOTE:GPU is not supported in 12 x 3.5-inch hard drive and 24 x 2.5-inch NVMe configuration systems.
NOTE:Low Profile and Full Height T4 cards are installed in order to support maximun 6 pcs T4 in x 16 slots.
NOTE:In Liquid Cooling system, maximum two DW GPUs are supported.
Table 3. Processor and heat sink matrixThis table describes the processor and heat sink restriction matrix.
Heat sink Processor TDP
STD HSK < 180 W
2U HPR (Silver) HSK >= 180 W
L-type HSK Supports all TDP (system should be installed with GPU/FGPA/long PCIe cards)
NOTE:All GPU/FGPA cards require 1U L-type HSK and GPU shroud.
Table 4. Label referenceThis table describes the label references used in the restriction tables.
Label Description
STD Standard
HPR (Silver) High performance (silver grade)
HPR (Gold) High performance (gold grade)
HSK Heat sink
LP Low profile
FH Full height
Table 5. Liquid cooling: CPU thermal restrictions (non-GPU/FPGA)This table describes the CPU liquid cooling thermal restrictions for non-GPU/FPGA.
Configuration 8 x 2.5-inch NVMe 16 x 2.5-inch SAS 16 x 2.5-inch NVMe 16 x 2.5-inch SAS + 8 x 2.5-inch NVMe 24 x 2.5-inch NVMe 8 x 3.5-inch 12 x 3.5-inch
Rear storage No Rear Drives No Rear Drives No Rear Drives No Rear Drives No Rear Drives No Rear Drives No Rear Drives 2 x rear 2.5-inch, No rear fan
CPU TDP/cTDP 120 W STD fan STD fan (A4 support) STD fan STD fan STD fan STD fan (A4 support) STD fan (A4 support) STD fan (A3 support)
155 W STD fan STD fan (A4 support) STD fan STD fan STD fan STD fan (A4 support) STD fan (A4 support) STD fan (A3 support)
170 W STD fan STD fan (A4 support) STD fan STD fan STD fan STD fan (A4 support) STD fan (A4 support) STD fan (A3 support)
180 W STD fan STD fan (A4 support) STD fan STD fan STD fan STD fan (A4 support) STD fan (A4 support) STD fan (A3 support)
200 W STD fan STD fan (A4 support) STD fan STD fan STD fan STD fan (A4 support) STD fan (A4 support) STD fan (A3 support)
225 W STD fan STD fan (A4 support) STD fan STD fan STD fan STD fan (A4 support) STD fan (A4 support) STD fan (A3 support)
240 W STD fan STD fan (A4 support) STD fan STD fan STD fan STD fan (A4 support) STD fan (A4 support) STD fan (A3 support)
280 W STD fan STD fan (A4 support) STD fan STD fan STD fan STD fan (A4 support) STD fan (A4 support) STD fan (A3 support)
Table 6. Liquid cooling: Memory thermal restrictions (non-GPU/FPGA)This table describes the memory liquid cooling thermal restrictions for non-GPU/FPGA.
Configuration 1 DPC 2 DPC 8 x 2.5-inch NVMe 16 x 2.5-inch SAS 16 x 2.5-inch NVMe 16 x 2.5-inch SAS + 8 x 2.5-inch NVMe 24 x 2.5-inch NVMe 8 x 3.5-inch 12 x 3.5-inch
Rear storage No Rear Drives No Rear Drives No Rear Drives No Rear Drives No Rear Drives No Rear Drives No Rear Drives 2 x rear 2.5-inch, No rear fan
Memory 8 GB RDIMM 3200 2.8 2.0 STD fan STD fan (A4 support) STD fan STD fan STD fan STD fan (A4 support) STD fan (A4 support) STD fan (A3 support)
16 GB RDIMM 3200 4.3 3.0 STD fan STD fan (A4 support) STD fan STD fan STD fan STD fan (A4 support) STD fan (A4 support) STD fan (A3 support)
32 GB RDIMM 3200 6.9 4.8 STD fan STD fan (A4 support) STD fan STD fan STD fan STD fan (A4 support) STD fan (A4 support) STD fan (A3 support)
64 GB RDIMM 3200 8.3 5.8 STD fan STD fan (A4 support) STD fan STD fan STD fan STD fan (A4 support) STD fan (A4 support) STD fan (A3 support)
128 GB LRDIMM 2666 12.4 9.9 STD fan STD fan (A3 support) STD fan STD fan STD fan STD fan (A3 support) STD fan (A3 support) STD fan (A3 support)

Particulate and gaseous contamination specifications

The following table defines the limitations that help avoid any equipment damage or failure from particulates and gaseous contamination. If the levels of particulates or gaseous pollution exceed the specified limitations and result in equipment damage or failure, you must rectify the environmental conditions. Remediation of environmental conditions is the responsibility of the customer.

Table 1. Particulate contamination specificationsAir filtration specification: Data center air filtration as defined by ISO Class 8 per ISO 14644-1 should have a 95% upper confidence limit. Note: This condition applies only to data center environments. Air filtration requirements do not apply to IT equipment designed to be used outside a data center, in environments such as an office or factory floor. Note: Air entering the data center must have MERV11 or MERV13 filtration. Conductive dust specification: Air must be free of conductive dust, zinc whiskers, or other conductive particles. Note: This condition applies to data center and non-data center environments. Corrosive dust specification: Air must be free of corrosive dust. Residual dust present in the air must have a deliquescent point less than 60% relative humidity. Note: This condition applies to data center and non-data center environments.
Particulate contamination Specifications
Air filtration: Conventional Data Center only Data center air filtration as defined by ISO Class 8 per ISO 14644-1 with a 95% upper confidence limit
NOTE: Filtering room air with a MERV8 filter, as specified in ANSI/ASHRAE Standard 127, is a recommended method for achieving the necessary environmental conditions.
NOTE:Air entering the data center must have MERV11 or MERV13 filtration.
NOTE:This condition applies to data center environments only. Air filtration requirements do not apply to IT equipment designed to be used outside a data center, in environments such as an office or factory floor.
Walk-Up Edge Data Center or Cabinet (sealed, closed loop environment) Filtration is not required for cabinets that are anticipated to be opened six times or less per year. Class 8 per ISO 1466-1 filtration as defined above is required otherwise.
NOTE: In environments commonly above ISA-71 Class G1 or that may have known challenges, special filters may be required.
Conductive dust: data center and non-data center environments Air must be free of conductive dust, zinc whiskers, or other conductive particles.
NOTE: Conductive dust, which can interfere with equipment operation, can originate from various sources, including manufacturing processes and zinc whiskers that may develop on the plating of raised floor tiles.
NOTE:This condition applies to data center and non-data center environments.
Corrosive dust: data center and non-data center environments
  • Air must be free of corrosive dust.
  • Residual dust present in the air must have a deliquescent point less than 60% relative humidity.
NOTE:This condition applies to data center and non-data center environments.
Table 2. Gaseous contamination specificationsThe copper coupon corrosion rate is <300 Å/month per Class G1 as defined by ANSI/ISA71.04. The silver coupon corrosion rate is <200 Å/month as defined by ANSI/ISA71.04.
Gaseous contamination Specifications Notes
Copper coupon corrosion rate ISA-71 Class G1: <300 Å/month Per ANSI/ISA71.04
Silver coupon corrosion rate ISA-71 Class G1: <200 Å/month Per ANSI/ISA71.04