Dell EMC PowerEdge R6525: технические характеристики и спецификации

Chassis dimensions

Figure 1. Chassis dimensions
This image shows chassis dimension for the PowerEge R6525 system.
Table 1. PowerEdgeR6525 chassis dimensionsThis table provides the dimensions of the PowerEdgeR6525 system:
Drives Xa Xb Y Za Zb*Zc
Eight drives 482.0 mm

(18.97 inches)

434.0 mm

(17.08 inches)

42.8 mm

(1.68 inches)

With bezel: 35.84 mm (1.4 inches)

Without bezel: 22.0 mm (0.87 inches)

700.53 mm

(27.58 inches)

(Ear to rear wall)
736.27 mm

(28.98 inches)

(Ear to PSU handle)
Four or ten drives 482.0 mm

(18.97 inches)

434.0 mm

(17.08 inches)

42.8 mm

(1.68 inches)

With bezel: 35.84 mm (1.4 inches)

Without bezel: 22.0 mm (0.87 inches)

751.48 mm

(29.58 inches)

(Ear to I/O label)
787.05 mm

(30.98 inches)

(Ear to PSU handle)
NOTE Zb* is the nominal rear wall external surface where the system board I/O connectors reside.

System weight

Table 1. PowerEdge R6525 system weightThe table below shows the maximum weight of the PowerEdge R6525.
System configuration Maximum weight (with all drives/SSDs)
4 x 3.5-inch 21.8 kg (48.06 lb)
8 x 2.5-inch 19.2 kg (42.33 lb)
10 x 2.5-inch 21.8 kg (48.06 lb)

Processor specifications

Table 1. PowerEdge R6525 processor specificationsThis table provides processor specifications for the PowerEdge R6525 system:
Supported processor Number of processors supported
AMD EPYC 7002 or 7003 series processors Two

PSU specifications

The PowerEdge R6525 system supports up to two AC or DC power supply units (PSUs).

WARNING Instructions for the qualified electricians only:

System using -(48-60) V DC or 240 V DC power supplies are intended for restricted access locations in accordance with Articles 110-5, 110-6, 110-11, 110-14, and 110-17 of the National Electrical Code, American National Standards Institute (ANSI)/National Fire Protection Association (NFPA) 70.

240 V DC power supplies shall be connected to the 240 V DC outlet from certified power distribution units if applicable in country of use.

Power supply cords/jumper cords and the associated plugs/inlets/connectors shall have appropriate electrical ratings referencing the rating label on the system when used for connection.

Table 1. PowerEdge R6525 PSU specificationsThis table describes PSU specifications.
PSU Class (AC only) Heat dissipation (maximum) Frequency Voltage Current
800 W Mixed Mode Platinum 3000 BTU/hr 50/60 Hz 100 -240 V AC 9.2 - 4.7 A
N/A DC 240 V DC 3.8 A
1100 W Mixed Mode Titanium 4100 BTU/hr 50/60 Hz 100–240 V AC 12 A-6.3 A (X2)
N/A DC 240 V DC 5.2 A DC
1100 W (-48Vdc) N/A 4265 BTU/hr DC (-48)-(-60) V DC 27 A
1400 W Mixed Mode Platinum 5250 BTU/hr 50/60 Hz 100 - 240 V AC 12 - 8 A AC
N/A DC 240 V DC 6.6 A DC
NOTE When selecting or upgrading the system configuration, to ensure optimum power utilization, verify the system power consumption with the Dell Energy Smart Solution Advisor available at Dell.com/ESSA.

Supported operating systems

The PowerEdge R6525 supports the following operating systems:

  • Canonical Ubuntu Server LTS
  • Citrix XenServer
  • Microsoft Windows Server with Hyper-V
  • Red Hat Enterprise Linux
  • SUSE Linux Enterprise Server
  • VMware vSAN/ESXi
For more information, see www.dell.com/ossupport.

Cooling fan specifications

The PowerEdgeR6525 system supports up to four standard (STD), high performance silver grade (HPR (Silver)), or high performance gold grade (HPR (Gold)) dual cooling fan modules.

Table 1. Cooling fan specificationsCooling fan specifications:
Fan type Abbreviation Also known as Label color Label image
Standard fanSTD STD No label
Figure 1. Standard fan
This image shows Standard fan module.
High performance (Silver grade) fan HPR (Silver) HPR Silver
NOTE New cooling fans comes with the High Performance Silver Grade label. While the older cooling fans has the High Performance label.
Figure 2. High performance fan
This image shows the High performance fan
Figure 3. High performance (Silver grade) fan
This image shows the High performance (Silver grade) fan
High performance (Gold grade) fan HPR (Gold) VHP - Very High Performance Gold
NOTE New cooling fans comes with the High Performance Gold Grade label. While the older cooling fans has the High Performance label.
Figure 4. High performance fan
This image shows the high performance fan
Figure 5. High performance (Gold grade) fan
This image shows the High performance (Gold grade) fan
NOTE You can distinguish between the High-performance (Silver) fan and High-performance (Gold) fan by the color of the label.
NOTE Mixing of STD, HPR (Silver), or HPR (Gold) fan is not supported.
NOTE The STD, HPR (Silver), or HPR (Gold) fan installation depends on the system configuration. For more information about the supported fan configuration or matrix, see Thermal restriction matrix.

System battery specifications

The PowerEdge R6525 system supports CR 2032 3.0-V lithium coin cell system battery.

Expansion card riser specifications

WARNING Consumer-Grade GPU should not be installed or used in the Enterprise Server products.
The PowerEdge R6525 system supports up to four PCI express (PCIe) Gen 4 expansion cards.
Table 1. Expansion card slots supported on the system boardThis table provides information about the expansion card slots that are supported on the PowerEdge R6525 system.
PCIe slot Risers Riser width PCIe slot height PCIe slot length Slot width
Slot 1 R2a (Riser 2) x32 PCIe Low profile Half length x16
Slot 1 R1a (Riser 1) x16 PCIe Full height 3/4th length x16
Slot 2 R2a (Riser 2) x32 PCIe Low profile Half length x16
Slot 2 R4c + R4d (Riser 4) x16 PCIe Full height 3/4th length x16
Slot 3 R3a (Riser 3) x16 PCIe Low profile Half length x16

Memory specifications

The PowerEdge R6525 system supports the following memory specifications for optimized operation.
Table 1. Memory specificationsThe table below shows the memory specifications for the PowerEdge PowerEdge system:
DIMM type DIMM rank DIMM capacity Single processor Dual processor
Minimum RAM Maximum RAM Minimum RAM Maximum RAM
RDIMM Single rank 8 GB 8 GB 128 GB 16 GB 256 GB
Dual rank 16 GB 16 GB 256 GB 32 GB 512 GB
32 GB 32 GB 512 GB 64 GB 1 TB
64 GB 64 GB 1 TB 128 GB 2 TB
LRDIMM Quad rank 128 GB 128 GB 2 TB 256 GB 4 TB
Octa rank 128 GB 128 GB 2 TB 256 GB 4 TB
NOTE The older 32 GB capacity RDIMM memory with x4 data width and 8Gb DRAM density cannot be mixed with the newer 32 GB capacity RDIMM memory with x8 data width and 16Gb DRAM density in the same AMD EPYC™ processor unit.
NOTE The older 128 GB capacity LRDIMM memory at 2666 MT/s speed cannot be mixed with the new 128 GB capacity LRDIMM memory at 3200 MT/s speed.
Table 2. Memory module socketsThe table below shows the memory module sockets for the PowerEdge R6525 system:
Memory module sockets Speed
32, 288-pin 3200 MT/s, 2933 MT/s, 2666 MT/s

Storage controller specifications

The PowerEdge R6525 system supports the following controller cards:
Table 1. PowerEdge R6525 system controller cardsThe table provides the controller cards that are supported by PowerEdge R6525 system:
Internal controllers External controllers
  • PERC H755N
  • PERC H745
  • HBA345
  • HBA355
  • S150
  • H345
  • Boot Optimized Storage Subsystem (BOSS-S1): HWRAID 2 x M.2 SSDs
  • Boot Optimized Storage Subsystem (BOSS-S2): HWRAID 2 x M.2 SSDs
  • 12 Gbps SAS Ext. HBA
  • PERC H840
  • HBA355E
NOTE The front PERC module for the PowerEdge R6525 system connects to the drive backplane. The front PERC module is connected in two different ways:
  • Front mounting front PERC module
  • Rear mounting front PERC module

Drives

The PowerEdge R6525 system supports:
  • 4 x 3.5-inch hot-swappable SAS, SATA drives
  • 8 x 2.5-inch hot-swappable SAS, SATA drives
  • 10 x 2.5-inch hot-swappable SAS, SATA , or NVMe drives
  • 10 + 2 x 2.5-inch hot-swappable SAS, SATA , or NVMe drives

Backplane:

  • Up to 2 x 2.5-inch SAS, SATA, or NVMe drives
  • Up to 4 x 3.5-inch SAS, SATA drives
  • Up to 8 x 2.5-inch SAS, SATA drives
  • Up to 10 x 2.5-inch SAS, SATA, or NVMe drives
NOTE For more information about how to hot swap NVMe PCIe SSD U.2 device, see the Dell Express Flash NVMe PCIe SSD User's Guide at https://www.dell.com/support Browse all Products > Data Center Infrastructure >  Storage Adapters & Controllers > Dell PowerEdge Express Flash NVMe PCIe SSD > Documentation > Manuals and Documents.

USB ports specifications

Table 1. PowerEdge R6525 system USB specificationsThe following table shows the USB specifications for the PowerEdge R6525 system:
Front Rear Internal
USB port type No. of ports USB port type No. of ports USB port type No. of ports
USB 2.0-compliant port One USB 3.0-compliant ports One Internal USB 3.0-compliant port One
Micro-USB 2.0 compliant port One USB 2.0-compliant ports One
NOTE The micro USB 2.0 compliant port can only be used as an iDRAC Direct or a management port.
NOTE The USB 2.0 specifications provide a 5 V supply on a single wire to power connected USB devices. A unit load is defined as 100 mA in USB 2.0, and 150 mA in USB 3.0. A device may draw a maximum of 5 unit loads (500 mA) from a port in USB 2.0; 6 (900 mA) in USB 3.0.
NOTE The USB 2.0 interface can provide power to low-power peripherals but must adhere to USB specification. An external power source is required for higher-power peripherals to function, such as external CD/DVD Drives.

NIC port specifications

The PowerEdge R6525 system supports up to two 10/100/1000 Mbps Network Interface Controller (NIC) ports embedded on the LAN on Motherboard (LOM) and integrated on the optional OCP cards.
Table 1. NIC port specification This table describes the NIC port specification.
Feature Specifications
LOM card 1 GB x 2
OCP card (OCP 3.0) 1 GbE x 4, 10 GbE x 2, 25 GbE x 2, 25 GbE x 4, 50 GbE x 2, 100 GbE x 2

Serial connector specifications

The PowerEdge R6525 system supports one optional card type serial connector, which is a 9-pin connector, Data Terminal Equipment (DTE), 16550-compliant.

The optional serial connector card is installed similar to an expansion card filler bracket.

VGA ports specifications

The PowerEdge R6525 system supports one DB-15 VGA port that is located on the front and rear panel of the system.

IDSDM

The PowerEdge R6525 system supports optional Internal Dual SD module (IDSDM).

The IDSDM supports two SD cards and is available in the following configurations:

Table 1. Supported SD card storage capacityThis table lists the storage capacity of the supported SD cards
IDSDM card
  • 16 GB
  • 32 GB
  • 64 GB
NOTE One IDSDM card slot is dedicated for redundancy.
NOTE Use Dell EMC branded SD cards that are associated with the IDSDM configured systems.

Video specifications

The PowerEdge R6525 system supports integrated Matrox G200 graphics controller with 16 MB of video frame buffer.
Table 1. Supported front video resolution optionsThis table describes the supported front video resolution options.
Resolution Refresh rate (Hz) Color depth (bits)
1024 x 768 60 8, 16, 32
1280 x 800 60 8, 16, 32
1280 x 1024 60 8, 16, 32
1360 x 768 60 8, 16, 32
1440 x 900 60 8, 16, 32
1600 x 900 60 8, 16, 32
1600 x 1200 60 8, 16, 32
1680 x 1050 60 8, 16, 32
1920 x 1080 60 8, 16, 32
1920 x 1200 60 8, 16, 32
Table 2. Supported rear video resolution optionsThis table describes the supported rear video resolution options.
Resolution Refresh rate (Hz) Color depth (bits)
1024 x 768 60 8, 16, 32
1280 x 800 60 8, 16, 32
1280 x 1024 60 8, 16, 32
1360 x 768 60 8, 16, 32
1440 x 900 60 8, 16, 32
1600 x 900 60 8, 16, 32
1600 x 1200 60 8, 16, 32
1680 x 1050 60 8, 16, 32
1920 x 1080 60 8, 16, 32
1920 x 1200 60 8, 16, 32

Environmental specifications

NOTE For additional information about environmental certifications, refer to the Product Environmental Datasheet located with the Manuals & Documents on www.dell.com/support/home.
Table 1. Operational climatic range category A2 This table describes the operational climatic range for category A2.
Temperature Specifications
Allowable continuous operations
Temperature ranges for altitudes <= 900 m (<= 2953 ft) 10–35°C (50–95°F) with no direct sunlight on the equipment
Humidity percent ranges (non-condensing at all times) 8% RH with -12°C minimum dew point to 80% RH with 21°C (69.8°F) maximum dew point
Operational altitude de-rating Maximum temperature is reduced by 1°C/300 m (1.8°F/984 Ft) above 900 m (2953 Ft)
Table 2. Operational climatic range category A3 This table describes the operational climatic range for category A3.
Temperature Specifications
Allowable continuous operations
Temperature ranges for altitudes <= 900 m (<= 2953 ft) 5–40°C (41–104°F) with no direct sunlight on the equipment
Humidity percent ranges (non-condensing at all times) 8% RH with -12°C minimum dew point to 85% RH with 24°C (75.2°F) maximum dew point
Operational altitude de-rating Maximum temperature is reduced by 1°C/175 m (1.8°F/574 Ft) above 900 m (2953 Ft)
Table 3. Operational climatic range category A4 This table describes the operational climatic range for category A4.
Temperature Specifications
Allowable continuous operations
Temperature ranges for altitudes <= 900 m (<= 2953 ft) 5–45°C (41–113°F) with no direct sunlight on the equipment
Humidity percent ranges (non-condensing at all times) 8% RH with -12°C minimum dew point to 90% RH with 24°C (75.2°F) maximum dew point
Operational altitude de-rating Maximum temperature is reduced by 1°C/125 m (1.8°F/410 Ft) above 900 m (2953 Ft)
Table 4. Shared requirements across all categories This table describes the shared requirements across all categories.
Temperature Specifications
Allowable continuous operations
Maximum temperature gradient (applies to both operation and non-operation) 20°C in an hour* (36°F in an hour) and 5°C in 15 minutes (9°F in 15 minutes), 5°C in an hour* (9°F in an hour) for tape hardware
NOTE * - Per ASHRAE thermal guidelines for tape hardware, these are not instantaneous rates of temperature change.
Non-operational temperature limits -40 to 65°C (-40 to 149°F)
Non-operational humidity limits 5% to 95% RH with 27°C (80.6°F) maximum dew point
Maximum non-operational altitude 12,000 meters (39,370 feet)
Maximum operational altitude 3,048 meters (10,000 feet)
Table 5. Maximum vibration specificationsThe maximum vibration specification of an operational system is 0.26 Grms at 5 Hz to 350 Hz (all operation orientations).The maximum vibration specification of a nonoperational system is 1.88 Grms at 10 Hz to 500 Hz for 15 minutes (all six sides tested).
Maximum vibration Specifications
Operating 0.21 Grms at 5 Hz to 500 Hz (all operation orientations)
Storage 1.88 Grms at 10 Hz to 500 Hz for 15 minutes (all six sides tested)
Table 6. Maximum shock pulse specificationsThe maximum shock specification of an operational system is six consecutively executed shock pulses in the positive and negative x, y, and z axis of 40 G for up to 2.3 ms. The maximum shock specification of a nonoperational system is six consecutively executed shock pulses in the positive and negative x, y, and z axis (one pulse on each side of the system) of 71 G for up to 2 ms.
Maximum shock pulse Specifications
Operating Six consecutively executed shock pulses in the positive and negative x, y, and z axis of 6 G for up to 11 ms.
Storage Six consecutively executed shock pulses in the positive and negative x, y, and z axis (one pulse on each side of the system) of 71 G for up to 2 ms.

Thermal air restrictions

ASHRAE A3 environment

  • CPU TDP equal or greater than 180 W are not supported.
  • Rear drives are not supported.
  • 128 GB or greater capacity LRDIMMs are not supported.
  • Two PSUs are required in redundant mode, however PSU failure is not supported.
  • Non-Dell qualified peripheral cards and/or peripheral cards greater than 25 W are not supported.
  • GPU is not supported.
  • BOSS 1.5 is not supported.
  • NVMe is not supported.

ASHRAE A4 environment

  • CPU TDP equal or greater than 155 W are not supported.
  • Rear drives are not supported.
  • 128 GB or greater capacity LRDIMMs are not supported.
  • Two PSUs are required in redundant mode, however PSU failure is not supported.
  • Non-Dell qualified peripheral cards and/or peripheral cards greater than Tier 5 cards are not supported.
  • GPU is not supported.
  • BOSS 1.5 is not supported.
  • OCP 3.0 card cooling tier greater than Tier4 is not supported.
  • NVMe is not supported.

Liquid cooling: ASHRAE A3 environment

  • 128 GB ir greater capacity LRDIMMs are not supported.
  • Two PSUs are required in redundant mode, but PSU failure is not supported.
  • Non Dell qualified peripheral cards and/or peripheral cards greater than 25 W are not supported.
  • GPU is not supported.
  • BOSS 1.5 is not supported.
  • NVMe is not supported.

Liquid cooling: ASHRAE A4 environment

  • Rear drives are not supported.
  • 128 GB ir greater capacity LRDIMMs are not supported.
  • Two PSUs are required in redundant mode, but PSU failure is not supported.
  • Non Dell qualified peripheral cards and/or peripheral cards greater than Tier 5 are not supported.
  • OCP 3.0 card cooling tier greater than Tier 4 is not supported.
  • GPU is not supported.
  • BOSS 1.5 is not supported.
  • NVMe is not supported.

Thermal restriction matrix

Table 1. Thermal restriction matrixThe table describes thermal restriction matrix for the PowerEdge R6525 system.
Configuration 4 x 3.5-inch 8 x 2.5-inch 10 x 2.5-inch SAS 10 x 2.5-inch NVMe
Rear configuration 3 LP/ 2 FH Rear 2 x 2.5-inch SAS Rear 2 x 2.5-inch NVMe 3 LP/ 2 FH Rear 2 x 2.5-inch NVMe(single processor) 3 LP/ 2 FH Rear 2 x 2.5-inch SAS Rear 2 x 2.5-inch NVMe 3 LP/ 2 FH Rear 2 x 2.5-inch NVMe
CPU TDP CPU cTDP Max
120 W 150 W STD fan

STD HSK

HPR Fan

STD HSK

HPR Fan

STD HSK

STD fan

STD HSK

HPR Fan

STD HSK

VHP fan

STD HSK

VHP fan

STD HSK

VHP fan

STD HSK

VHP fan

STD HSK

VHP fan

STD HSK

155 W 180 W STD fan

STD HSK

HPR Fan

STD HSK

HPR Fan

STD HSK

STD fan

STD HSK

HPR Fan

STD HSK

VHP fan

STD HSK

VHP fan

STD HSK

VHP fan

STD HSK

VHP fan

STD HSK

VHP fan

STD HSK

180 W 200 W HPR fan

L-type HSK

HPR Fan

L-type HSK

HPR Fan

L-type HSK

HPR fan

L-type HSK

HPR Fan

L-type HSK

VHP fan

L-type HSK

VHP fan

L-type HSK

VHP fan

L-type HSK

VHP fan

L-type HSK

VHP fan

L-type HSK

200 W 200 W HPR fan

L-type HSK

HPR Fan

L-type HSK

HPR Fan

L-type HSK

HPR fan

L-type HSK

HPR Fan

L-type HSK

VHP fan

L-type HSK

VHP fan

L-type HSK

VHP fan

L-type HSK

VHP fan

L-type HSK

VHP fan

L-type HSK

225 W 240 W HPR fan

L-type HSK

HPR Fan

L-type HSK

HPR Fan

L-type HSK

HPR fan

L-type HSK

HPR Fan

L-type HSK

VHP fan

L-type HSK

VHP fan

L-type HSK

VHP fan

L-type HSK

VHP fan

L-type HSK

VHP fan

L-type HSK

280 W - 64C

(7H12,7763)

HPR fan*

L-type HSK

HPR Fan*

L-type HSK

HPR Fan*

L-type HSK

HPR fan

L-type HSK

HPR Fan*

L-type HSK

VHP fan*

L-type HSK

VHP fan*

L-type HSK

VHP fan*

L-type HSK

VHP fan

L-type HSK

VHP fan*

L-type HSK

280 W - 32C

(75F3)

- - - VHP fan*

L-type HSK

- VHP fan*

L-type HSK

- - VHP fan*

L-type HSK

-
280 W - 64C/32C/24C 280 W (7773X,7573X,7473X) - - - - - VHP fan

L-type HSK

VHP fan*

L-type HSK

VHP fan*

L-type HSK

- -
280 W - 16C 280 W

(7373X)

- - - - - VHP fan**

L-type HSK

- - - -
T4 or A2 GPU HPR fan* HPR Fan* HPR Fan* HPR fan* - VHP fan* VHP fan* VHP fan* VHP fan* VHP fan*
NOTE * Supported ambient temperature is 30°C.
NOTE ** Supported ambient temperature is 25°C.
Table 2. Liquid cooling thermal restriction matrixThis table describes the liquid cooling thermal restriction matrix.
Configuration 4 x 3.5-inch 8 x 2.5-inch 10 x 2.5-inch SAS 10 x 2.5-inch NVMe
Rear storage 3 LP/ 2 FH Rear 2 x 2.5-inch SAS Rear 2 x 2.5-inch NVMe 3 LP/ 2 FH 3 LP/ 2 FH Rear 2 x 2.5-inch SAS Rear 2 x 2.5-inch NVMe 3 LP/ 2 FH Rear 2 x 2.5-inch NVMe
CPU TDP CPU cTDP Max
120 W 150 W HPR fan HPR fan HPR fan HPR fan HPR fan HPR fan HPR fan HPR fan HPR fan
155 W 180 W HPR fan HPR fan HPR fan HPR fan HPR fan HPR fan HPR fan HPR fan HPR fan
180 W 200 W HPR fan HPR fan HPR fan HPR fan HPR fan HPR fan HPR fan HPR fan HPR fan
200 W 200 W HPR fan HPR fan HPR fan HPR fan HPR fan HPR fan HPR fan HPR fan HPR fan
225 W 240 W HPR fan HPR fan HPR fan HPR fan HPR fan HPR fan HPR fan HPR fan HPR fan
280 W 280 W HPR fan HPR fan HPR fan HPR fan HPR fan HPR fan HPR fan HPR fan HPR fan
T4 GPU HPR fan HPR fan HPR fan HPR fan HPR fan HPR fan HPR fan HPR fan HPR fan
NOTE Three dual fan modules are required for single processor, and four dual fan modules are required for dual processor system.
NOTE For T4 GPU and 280 W CPU, maximum supported ambient temperature is 30°C. For other configurations maximum supported ambient temperature is 35°C.
Table 3. Processor and heat sink matrixThis table describes the processor and heat sink restriction matrix.
Heat sink Processor TDP
STD HSK < 180 W
L-type HSK Processor 1 >= 180 W
L-type HSK Processor 2 >= 180 W
Table 4. Processor support matrixThis table describes the processor support matrix.
Processor TDP (W) cTDP Max (W) Cores Heat sink (HSK) type Fan type (x4/x8) Fan type (x10) Support A3 Support A4
7773X 280 280 64 L-type HSK NA HPR (gold) fan No No
7573X 280 280 32 L-type HSK NA HPR (gold) fan No No
7H12 280 280 64 L-type HSK HPR (silver) fan HPR (gold) fan No No
7F72 240 240 24 L-type HSK HPR(silver) fan HPR (gold) fan No No
7F52 225 240 16 L-type HSK HPR (silver) fan HPR (gold) fan No No
7662 225 240 64 L-type HSK HPR (silver) fan HPR (gold) fan No No
7643 240 240 56 L-type HSK HPR (silver) fan HPR (gold) fan No No
7742 225 240 64 L-type HSK HPR (silver) fan HPR (gold) fan No No
7713P 225 240 64 L-type HSK HPR (silver) fan HPR (gold) fan No No
7642 225 240 48 L-type HSK HPR (silver) fan HPR (gold) fan No No
7552 200 200 48 L-type HSK HPR (silver) fan HPR (gold) fan No No
7702 200 200 64 L-type HSK HPR (silver) fan HPR (gold) fan No No
7663 240 240 56 L-type HSK HPR (silver) fan HPR (gold) fan No No
7543P 225 240 32 L-type HSK HPR (silver) fan HPR (gold) fan No No
7542 225 240 32 L-type HSK HPR (silver) fan HPR (gold) fan No No
7532 200 200 32 L-type HSK HPR (silver) fan HPR (gold) fan No No
7F32 180 180 8 L-type HSK HPR (silver) fan HPR (gold) fan No No
7513 200 200 32 L-type HSK HPR (silver) fan HPR (gold) fan No No
7502 180 200 32 L-type HSK HPR (silver) fan HPR (gold) fan No No
74F3 240 240 24/48 L-type HSK HPR (silver) fan HPR (gold) fan No No
7402 180 200 24 L-type HSK HPR (silver) fan HPR (gold) fan No No
7452 155 180 32 STD HSK STD fan HPR (gold) fan Yes No
7443P 200 200 24 L-type HSK HPR (silver) fan HPR (gold) fan No No
7443 200 200 24 L-type HSK HPR (silver) fan HPR (gold) fan No No
7352 155 180 24 STD HSK STD fan HPR (gold) fan Yes No
7343 200 200 32 L-type HSK HPR (silver) fan HPR (gold) fan No No
7313P 155 180 16 STD HSK STD fan HPR (gold) fan Yes No
7302 155 180 16 STD HSK STD fan HPR (gold) fan Yes No
72F3 180 200 8 L-type HSK HPR (silver) fan HPR (gold) fan No No
7282 120 150 16 STD HSK STD fan HPR (gold) fan Yes Yes
7272 120 150 12 STD HSK STD fan HPR (gold) fan Yes Yes
7252 120 150 8 STD HSK STD fan HPR (gold) fan Yes Yes
7262 155 180 8 STD HSK STD fan HPR (gold) fan Yes No
NOTE DIMM blanks are required on empty slots if 280 W CPU is installed.
NOTE Processors 7573X and 7773X support only x10 SAS/SATA drives.
Table 5. T4 GPU support restrictionThis table describes the T4 GPU support restriction.
2.5-inch x 10 2.5-inch x 8 3.5-inch x 4
Rear Config 3 x LP 2 x FH 3 x LP 2 x FH 3 x LP 2 x FH
Slot 1 Supported Supported Supported Supported Supported Supported
Slot 2 Supported Supported Supported Supported Supported Supported
Slot 3 Supported NA Not supported NA Not supported NA
NOTE 128 GB LRDIMM 3200 MT/s or higher memory is not supported with 280 W T4/A2 configuration.
Table 6. Label referenceThis table describes the label references used in the restriction tables.
Label Description
STD Standard
HPR High performance (silver grade)
VHP Very high performance (gold grade)
HSK Heat sink
LP Low profile
FH Full height