Dell EMC PowerEdge R440: технические характеристики и спецификации

System dimensions

Figure 1. Dimensions of the Dell EMCPowerEdgeR440system
This image shows dimensions of the PowerEdge R440 system
Table 1. Dimensions of the Dell EMCPowerEdgeR440systemThis table gives details of the dimensions of the Dell EMCPowerEdgeR440system
XaXbYZa Zb Zc
482.0 mm (18.97 inches)434.0 mm (17.08 inches)42.8 mm (1.68 inches)35.84 mm (1.41 inches) (with bezel)

22 mm (0.87 inches) (without bezel)

x4 and x10 = 657.25 mm (25.87 inches)

x8 = 606.47 (23.87 inches)
x4 and x10 = 692.62 (27.26 inches)

x8 = 641.85 mm (25.26 inches)

Chassis weight

Table 1. Dell EMC PowerEdge R440 system Chassis weightThe table below shows the maximum weight of the Dell EMC PowerEdge R440 system:
SystemMaximum weight (with all drives/SSDs)
4 x 3.5-inch drive system 17.64 Kg (38.90 lb)
8 x 2.5-inch drive system16.04 Kg (35.36 lb)
10 x 2.5-inch drive system16.81 Kg (37.07 lb)

Processor specifications

The Dell EMC PowerEdge R440 system supports up to two Intel Xeon Scalable Processor, up to 22 cores per processor.

Supported operating systems

The Dell EMC PowerEdge R440 system supports the following operating systems:

  • Canonical Ubuntu LTS
  • Citrix XenServer
  • Microsoft Windows Server with Hyper-V
  • Red Hat Enterprise Linux
  • SUSE Linux Enterprise Server
  • VMware ESXi
NOTE For more information, go to www.dell.com/ossupport.

PSU specifications

The Dell EMC PowerEdge R440 system supports the following AC power supply units (PSU).
Table 1. PSU specificationsThe table below are the specifications for power supplies.
PSU Class Heat dissipation (maximum) Frequency Voltage
550 W AC Platinum 2559 BTU/hr 50/60 Hz  100–240 V AC, autoranging
450 W AC (no longer offering) Bronze 1871 BTU/hr 50/60 Hz  100–240 V AC, autoranging
NOTE Heat dissipation is calculated using the PSU wattage rating.
NOTE This system is also designed to connect to the IT power systems with a phase-to-phase voltage not exceeding 230 V.

System battery

The Dell EMC PowerEdge R440 system supports CR 2032 3.0-V lithium coin cell system battery.

Expansion bus specifications

The Dell EMC PowerEdge R440 system supports PCI express (PCIe) generation three expansion cards, which must be installed on the system board using expansion card risers.
Table 1. Expansion card riser configurationsThis table provides information about the expansion card riser configuration for Dell EMC PowerEdge R440 system:
Expansion card riser PCIe slots on the riser Height Length Link
LOM riser Slot 1 Mezz type Mezz type x8
Right riser Slot 2 Low Profile Half Length x16
Right riser Slot 2 Full Height Half Length x16
PCIe passive bridge Slot-integrated Low Profile Half Length x8
Internal riser Slot-integrated Low Profile Half Length x8
Left riser Slot 2 Low Profile Half Length x16
Left riser Slot 3 Low Profile Half Length x16

Memory specifications

Table 1. Memory specificationsThe table below shows the memory specifications of Dell EMC PowerEdge R440 system.
DIMM type DIMM rank DIMM capacity Single processor Dual processors
Minimum RAM Maximum RAM Minimum RAM Maximum RAM
RDIMM Single rank 8 GB 8 GB 80 GB 16 GB 128 GB
RDIMM Dual rank 16 GB 16 GB 160 GB 32 GB 256 GB
RDIMM Dual rank 32 GB 32 GB 320 GB 64 GB 512 GB
LRDIMMQuad rank 64 GB 64 GB640 GB128 GB1024 GB

Storage controller specifications

The Dell EMC PowerEdge R440 system supports:
  • Software RAID: S140
  • Internal controllers: H750, H350, H740p, H730p, H330
  • Boot Optimized Storage Subsystem (BOSS): HWRAID 2 x M.2 SSDs 120 GB, 240 GB with 6 Gb/s
    • x8 connector using PCIe Gen 2.0 x2 lanes, available only in the low-profile and half-height form factor.
  • External controller: HBA355e, H840, 12 Gbps Ext SAS HBA
  • SAS Hot Bus Adapters: HBA350i, HBA330
NOTE The new generation PERC 11 H750, H350, and HBA350i adapters cannot be mixed with the PERC H740P, H730P, H330, HBA330 adapters of the previous generations in one system.

Drives

The Dell EMC PowerEdge R440 system supports:
  • 4x3.5 configuration: up to 4 SAS or SATA drives (SDD/HDD) / Nearline SAS HDDs
  • 8x2.5 configuration: up to 8 SAS or SATA drives (SDD/HDD)
  • 10x2.5 configuration: up to 10 SAS or SATA drives (SDD/HDD)
  • 10x2.5 with NVMe configuration: up to 4 NVMe SSDs + SAS or SATA drives (SDD/HDD) on remaining slots

Drives are supplied in hot swappable drive carriers that fit in the drive slots.

CAUTION Before attempting to remove or install a drive while the system is running, see the documentation for the storage controller card to ensure that the host adapter is configured correctly.
CAUTION Do not turn off or restart your system while a drive is being formatted. Doing so can cause a drive failure.

When you format a drive, allow enough time for the formatting to complete. Be aware that high-capacity drives can take a long time to format.

USB ports

Table 1. Dell EMC PowerEdge R440 system USB specificationsThe following table provides information about the USB specifications:
Front panel Back panelInternal USB
  • One USB 2.0-compliant port
  • One iDRAC Direct (Micro-AB USB) port
  • Two USB 3.0-compliant port
  • One internal USB 3.0 port

NIC ports

The Dell EMC PowerEdge R440 system supports two Network Interface Controller (NIC) ports on the back panel, which have two 1 Gbps configuration.
NOTE You can install up to three NIC cards (two PCIe AIC cards and one OCP card).

Serial connector

The serial connector connects a serial device to the system. The Dell EMC PowerEdge R440 system supports one serial connector on the back panel, which is a 9-pin connector, Data Terminal Equipment (DTE), 16550-compliant.

VGA ports

The Video Graphic Array (VGA) port enables you to connect the system to a VGA display. The Dell EMC PowerEdge R440 system supports two 15-pin VGA ports.

IDSDM or vFlash card

The Dell EMC PowerEdge R440 systemIDSDM module contains both Internal Dual SD Module (IDSDM) and vFlash card that are combined into a single card module. The following are options available for PowerEdge R440 system:
  • VFlash only
  • IDSDM only
  • vFlash + IDSDM

Video specifications

The Dell EMC PowerEdge R440 system supports Matrox G200eW3 graphics card with 16 MB capacity.
Table 1. Supported video resolution optionsThis table describes the supported video resolution options of Dell EMC PowerEdge R440 system:
Resolution Refresh rate (Hz) Color depth (bits)
1024 x 768 60 8, 16, 32
1280 x 800 60 8, 16, 32
1280 x 1024 60 8, 16, 32
1360 x 768 60 8, 16, 32
1440 x 900 60 8, 16, 32
1600 x 900 60 8, 16, 32
1600 x 1200 60 8, 16, 32
1680 x 1050 60 8, 16, 32
1920 x 1080 60 8, 16, 32
1920 x 1200 60 8, 16, 32

Environmental specifications

NOTE For additional information about environmental certifications, please refer to the Product Environmental Datasheet located with the Manuals & Documents on www.dell.com/poweredgemanuals
Table 1. Temperature specificationsThe table below shows the optimal working temperature specifications.
Temperature Specifications
Storage –40°C to 65°C (–40°F to 149°F)
Continuous operation (for altitude less than 950 m or 3117 ft) 10°C to 35°C (50°F to 95°F) with no direct sunlight on the equipment.
Fresh air For information about fresh air, see the Expanded Operating Temperature section.
Maximum temperature gradient (operating and storage) 20°C/h (68°F/h)
Table 2. Relative humidity specificationsThe table below shows the relative humidity specification during operations and storage.
Relative humidity Specifications
Storage 5% to 95% RH with 33°C (91°F) maximum dew point. Atmosphere must be non-condensing at all times.
Operating 10% to 80% relative humidity with 29°C (84.2°F) maximum dew point.
Table 3. Maximum vibration specificationsThe table below shows the maximum vibration specifications during operations and storage.
Maximum vibration Specifications
Operating 0.26 Grms at 5 Hz to 350 Hz (all operation orientations).
Storage 1.88 Grms at 10 Hz to 500 Hz for 15 min (all six sides tested).
Table 4. Maximum shock specificationsThe table below shows the maximum shock specifications during operations and storage.
Maximum shock Specifications
Operating Six consecutively executed shock pulses in the positive and negative x, y, and z axes of 6 G for up to 11 ms.
Storage Six consecutively executed shock pulses in the positive and negative x, y, and z axes (one pulse on each side of the system) of 71 G for up to 2 ms.
Table 5. Maximum altitude specificationsThe table below shows the maximum altitude specifications during operations and storage.
Maximum altitude Specifications
Operating

30482000 m (10,0006560 ft)

Storage 12,000 m (39,370 ft)
Table 6. Operating temperature derating specificationsThe table below shows the operating temperature derating specifications.
Operating temperature derating Specifications
Up to 35°C (95°F) Maximum temperature is reduced by 1°C/300 m (1°F/547 ft) above 950 m (3,117 ft).
35°C to 40°C (95°F to 104°F) Maximum temperature is reduced by 1°C/175 m (1°F/319 ft) above 950 m (3,117 ft).
40°C to 45°C (104°F to 113°F) Maximum temperature is reduced by 1°C/125 m (1°F/228 ft) above 950 m (3,117 ft).

Standard operating temperature

Table 1. Standard operating temperature specificationsThe standard operating temperature for altitude less than 950 metres or 3117 feet ranges from 10°C to 35°C (50°F to 95°F) with no direct sunlight on the equipment.
Standard operating temperature Specifications
Continuous operation (for altitude less than 950 m or 3117 ft) 10°C to 35°C (50°F to 95°F) with no direct sunlight on the equipment.

Expanded operating temperature

Table 1. Expanded operating temperature specificationsWhen the system is in continuous operation, the expanded operating temperature ranges from 10°C to 40°C at 5% to 85% RH with 29°C dew point. NOTE: Outside the standard operating temperature (10°C to 40°C), the system can operate continuously in temperatures as low as 5°C and as high as 40°C. For temperatures between 35°C and 40°C, de-rate maximum allowable temperature by 1°C per 175 m above 950 m (1°F per 319 ft). When the system is operating at < 1% of annual operating hours, the expanded operating temperature is –5°C to 45°C at 5% to 90% RH with 29°C dew point.

NOTE: Outside the standard operating temperature (10°C to 40°C), the system can operate down to –5°C or up to 45°C for a maximum of 1% of its annual operating hours. For temperatures between 40°C and 45°C, de-rate maximum allowable temperature by 1°C per 125 m above 950 m (1°F per 228 ft).

Expanded operating temperature Specifications
Continuous operation 5°C to 40°C at 5% to 85% RH with 29°C dew point.
NOTE Outside the standard operating temperature (10°C to 40°C), the system can operate continuously in temperatures as low as 5°C and as high as 40°C.

For temperatures between 35°C and 40°C, de-rate maximum allowable temperature by 1°C per 175 m above 950 m (1°F per 319 ft).

≤ 1% of annual operating hours –5°C to 45°C at 5% to 90% RH with 29°C dew point.
NOTE Outside the standard operating temperature (10°C to 40°C), the system can operate down to –5°C or up to 45°C for a maximum of 1% of its annual operating hours.

For temperatures between 40°C and 45°C, de-rate maximum allowable temperature by 1°C per 125 m above 950 m (1°F per 228 ft).

NOTE When operating in the expanded temperature range, system performance may be impacted.
NOTE When operating in the expanded temperature range, ambient temperature warnings may be reported on the bezel's LCD panel and in the System Event Log.

Expanded operating temperature restrictions

  • Do not perform a cold startup below 5°C.
  • The operating temperature specified is for a maximum altitude of 3048 m (10,000 ft).
  • 105 W/4C, 115 W/6C, 130 W/8C, 140 W/14C or higher wattage processor (TDP>140 W) are not supported.
  • Redundant power supply configuration is required.
  • Non-Dell qualified peripheral cards and/or peripheral cards greater than 25 W are not supported.
  • NVMe drives are not supported.
  • Apache Pass DIMM and NVDIMM are not supported.

Thermal restriction matrix

Table 1. Thermal restriction matrix for Dell EMC PowerEdge R440 systemThis table describes the thermal restriction for Dell EMC PowerEdge R440 system:
Storage configuration 10x 2.5-inch with NVMe drive 10x 2.5-inch drive 8x 2.5-inch drive 4x 3.5-inch drive
Processor number TDP (W) Core count Ambient support = 35°C
Intel Xeon Gold 6240 150 18 Yes Yes Yes Yes
Intel Xeon Gold 6242 150 16 Yes Yes Yes Yes
Intel Xeon Gold 6248 150 20 Yes Yes Yes Yes
Intel Xeon Gold 6252 150 24 Yes Yes Yes Yes
Intel Xeon Gold 6152 140 22 Yes Yes Yes Yes
Intel Xeon Gold 6140 18 Yes Yes Yes Yes
Intel Xeon Gold 6138 125 20 Yes Yes Yes Yes
Intel Xeon Gold 6130 16 Yes Yes Yes Yes
Intel Xeon Platinum 8153 16 Yes Yes Yes Yes
Intel Xeon Gold 6132 140 14 No

C30

Yes Yes Yes
Intel Xeon Gold 6134 130 8 No

C30

Yes Yes Yes
Intel Xeon Gold 6126 125 12 Yes Yes Yes Yes
Intel Xeon Gold 6128 115 6 No

C30

Yes Yes Yes
Intel Xeon Gold 6230 125 20 Yes Yes Yes Yes
Intel Xeon Gold 5122 105 4 No

C30

Yes Yes Yes
Intel Xeon Gold 5215 85 10 Yes Yes Yes Yes
Intel Xeon Gold 5217 115 8 No

C30

Yes Yes Yes
Intel Xeon Gold 5218 125 16 Yes Yes Yes Yes
Intel Xeon Gold 5220 125 18 Yes Yes Yes Yes
Intel Xeon Gold 5222 105 4 No

C30

Yes Yes Yes
Intel Xeon Platinum 8156 105 4 No

C30

Yes Yes Yes
Intel Xeon Gold 5120 105 14 Yes Yes Yes Yes
Intel Xeon Gold 5118 105 12 Yes Yes Yes Yes
Intel Xeon Gold 5115 85 10 Yes Yes Yes Yes
Intel Xeon Silver 4116 85 12 Yes Yes Yes Yes
Intel Xeon Silver 4114 85 10 Yes Yes Yes Yes
Intel Xeon Silver 4110 85 8 Yes Yes Yes Yes
Intel Xeon Silver 4108 85 8 Yes Yes Yes Yes
Intel Xeon Silver 4208 85 8 Yes Yes Yes Yes
Intel Xeon Silver 4210 85 10 Yes Yes Yes Yes
Intel Xeon Silver 4214 85 12 Yes Yes Yes Yes
Intel Xeon Silver 4215 85 8 Yes Yes Yes Yes
Intel Xeon Silver 4216 100 16 Yes Yes Yes Yes
Intel Xeon Bronze 3106 85 8 Yes Yes Yes Yes
Intel Xeon Bronze 3104 85 6 Yes Yes Yes Yes
Intel Xeon Bronze 3204 85 6 Yes Yes Yes Yes
Intel Xeon Silver 4112 85 4 Yes Yes Yes Yes

Particulate and gaseous contamination specifications

The following table defines the limitations that help avoid any equipment damage or failure from particulates and gaseous contamination. If the levels of particulates or gaseous pollution exceed the specified limitations and result in equipment damage or failure, you may need to rectify the environmental conditions. Re-mediation of environmental conditions is the responsibility of the customer.
Table 1. Particulate contamination specificationsAir filtration specification: Data center air filtration as defined by ISO Class 8 per ISO 14644-1 shpuld have a 95% upper confidence limit. Note: This condition applies only to data center environments. Air filtration requirements do not apply to IT equipment designed to be used outside a data center, in environments such as an office or factory floor. Note: Air entering the data center must have MERV11 or MERV13 filtration. Conductive dust specification: Air must be free of conductive dust, zinc whiskers, or other conductive particles. Note: This condition applies to data center and non-data center environments. Corrosive dust specification: Air must be free of corrosive dust. Residual dust present in the air must have a deliquescent point less than 60% relative humidity. Note: This condition applies to data center and non-data center environments.
Particulate contamination Specifications
Air filtration Data center air filtration as defined by ISO Class 8 per ISO 14644-1 with a 95% upper confidence limit.
NOTE This condition applies to data center environments only. Air filtration requirements do not apply to IT equipment designed to be used outside a data center, in environments such as an office or factory floor.
NOTE Air entering the data center must have MERV11 or MERV13 filtration.
Conductive dust Air must be free of conductive dust, zinc whiskers, or other conductive particles.
NOTE This condition applies to data center and non-data center environments.
Corrosive dust
  • Air must be free of corrosive dust.
  • Residual dust present in the air must have a deliquescent point less than 60% relative humidity.
NOTE This condition applies to data center and non-data center environments.
Table 2. Gaseous contamination specificationsThe copper coupon corrosion rate is <300 Å/month per Class G1 as defined by ANSI/ISA71.04-1985. The silver coupon corrosion rate is <200 Å/month as defined by AHSRAE TC9.9.
Gaseous contamination Specifications
Copper coupon corrosion rate <300 Å/month per Class G1 as defined by ANSI/ISA71.04-1985.
Silver coupon corrosion rate <200 Å/month as defined by AHSRAE TC9.9.
NOTE Maximum corrosive contaminant levels measured at ≤50% relative humidity.