Dell EMC PowerEdge R350: технические характеристики и спецификации

Chassis dimensions

Figure 1. Chassis dimensions

The image shows system dimensions.

Table 1. PowerEdge R350 chassis dimensionsThis table provides the dimensions of the system:
Drives Xa Xb Y Za Zb Zc
4 x 3.5-inch482.0 mm (18.98 inches)434.0 mm (17.09 inches)42.8 mm (1.7 inches)35.64 mm (1.40 inches)With bezel

22.0 mm (0.86 inches)Without bezel

534.59 mm (21.04 inches)

Ear to rear wall

563.3 mm (22.18 inches)

Ear to PSU handle

8 x 2.5-inch482.0 mm (18.98 inches)434.0 mm (17.09 inches)42.8 mm (1.7 inches)35.64 mm (1.40 inches)With bezel

22.0 mm (0.86 inches)Without bezel

483.82 mm (19.04 inches)Ear to rear wall512.53 mm (20.17 inches)Ear to PSU handle
NOTE Zb is the nominal rear wall external surface where the system board I/O connectors reside.

System weight

Table 1. PowerEdge R350 system weightThe table below shows the maximum weight of the system.
System configuration Maximum weight (with all drives/SSDs)
4 x 3.5-inch 13.14 kg (28.96 pound)
8 x 2.5-inch 11.74 kg (25.88 pound)

Processor specifications

Table 1. PowerEdge R350 processor specifications This table provides processor specifications for the system.
Supported processor Number of processors supported
Intel Xeon E-2300 series processor with up to 8 cores One

PSU specifications

The PowerEdge R350 system supports up to two AC power supply units (PSUs).

Table 1. PSU specifications This table describes PSU specifications for the system.
PSU Class Heat dissipation (maximum) Frequency Voltage AC DC Input AC Current DC Current
High line 200–240 V Low line 100–120 V
600 W AC Platinum 2250 BTU/hr 50/60 Hz 100 - 240 V, autoranging 600 W 600 W 240 VDC 7.1 - 3.6 A 2.9 A
NOTE This system is also designed to connect to the IT power systems with a phase-to-phase voltage not exceeding 240 V.
NOTE Heat dissipation is calculated using the PSU wattage rating.
NOTE When selecting or upgrading the system configuration, to ensure optimum power utilization, verify the system power consumption with the Enterprise Infrastructure Planning Tool available at Dell.com/calc.

Cooling fans specifications

The PowerEdge R350 system supports up to four non hot plug system fans connected to the system board.

NOTE For more information about the fan support configuration or matrix, see Thermal restriction matrix.

Supported operating systems

The PowerEdge R350 system supports the following operating systems:

  • Canonical Ubuntu Server LTS
  • VMware ESXi
  • Microsoft Windows Server with Hyper-V
  • Red Hat Enterprise Linux
  • SUSE Linux Enterprise Server

For more information, go to www.dell.com/ossupport.

System battery specifications

The PowerEdge R350 system supports CR 2032 3.0-V lithium coin cell system battery.

Expansion card riser specifications

The PowerEdge R350 system supports up to three PCI express (PCIe) Gen 4 expansion cards.
Table 1. Expansion card slots supported on the system boardThis table provides information about the expansion card slots that are supported on the system.
PCIe slot Form factor Processor PCIe slot bandwidth PCIe slot connector
Slot 1 Half Height Processor 1 Gen4 x8 lanes x8
Slot 2 Half Height Processor 1 Gen4 x8 lanes x16
Internal Half Length Processor 1 Gen4 x4 lanes x8
Table 2. Riser Configuration 0This table provides information for riser configuration 0 supported on the system.
PCIe slot Risers Riser width PCIe slot height PCIe slot length PCIe slot width
Slot 1 Butterfly Riser Single Wide Half Height Half Length x8
Slot 2 Butterfly Riser Single Wide Half Height Half Length x8
Internal NA Single Wide Half Height Half Length x4

Memory specifications

The PowerEdge R350 system supports the following memory specifications for optimized operation.
Table 1. Memory specificationsThe table below shows the memory specifications:
DIMM type DIMM rank DIMM capacity Single processor
Minimum system capacity Maximum system capacity
UDIMM Single rank 8 GB 8 GB 32 GB
16 GB 16 GB 64 GB
Dual rank 32 GB 32 GB 128 GB
Table 2. Memory module socketsThe table below shows the memory module sockets for the system:
Memory module sockets Speed
4, 288-pin 3200 MT/s, 2933 MT/s, 2666 MT/s
NOTE Memory DIMM slots are not hot pluggable.
NOTE Pentium processors support up to 2666 MT/s only. All channels in a system run at the fastest common frequency.
NOTE Using dual rank UDIMMs with two DIMMs per channel (2DPC) limits the speed to 2933 MT/s.

Storage controller specifications

The PowerEdge R350 system supports the following controller cards:
Table 1. Storage controller cards This table provides the controller cards supported on the system:
Internal controllers External controllers
  • PERC H355
  • PERC H355f
  • PERC H345
  • PERC H755
  • HBA355i
  • PERC H345f
  • PERC H755f
  • HBA355f
  • HBA355e

Drives

The PowerEdge R350 system supports:
  • 4 x 3.5-inch hot-swappable SAS, SATA drives.
  • 8 x 2.5-inch hot-swappable SAS, SATA drives.
  • Max 80TB for 4 HDD configurations

Optical drives

The PowerEdge R350 system supports one Slim SATA DVD-ROM drive or DVD +/- RW drive.
NOTE DVD devices support only data.

NIC port specifications

The PowerEdge R350 system supports up to two 10/100/1000 Mbps Network Interface Controller (NIC) ports embedded on Motherboard.
Table 1. NIC port specification for the systemThis table describes the NIC port specification for the system.
Feature Specifications
LOM 1 GB x 2

Serial connector specifications

The PowerEdge R350 system supports serial connector, which is a 9-pin connector, Data Terminal Equipment (DTE), 16550-compliant .

USB ports specifications

Table 1. PowerEdge R350 USB specificationsThe following table shows the USB specifications for the system:
Front Rear Internal (Optional)
USB port type No. of ports USB port type No. of ports USB port type No. of ports
USB 2.0-compliant port One USB 3.0-compliant port One Internal USB 3.0-compliant port One
iDRAC Direct port (Micro-AB USB 2.0-compliant port) One USB 2.0-compliant port One
NOTE The micro USB 2.0 compliant port can only be used as an iDRAC Direct or a management port.

VGA ports specifications

The PowerEdge R350 system supports One DB-15 VGA port on back panel.

IDSDM

The PowerEdge R350 system supports Internal Dual SD module (IDSDM).

The IDSDM supports two SD cards and is available in the following configurations:

Table 1. Supported SD card storage capacityThis table lists the storage capacity of the supported SD cards
IDSDM card
  • 16 GB
  • 32 GB
  • 64 GB
NOTE One IDSDM card slot is dedicated for redundancy.
NOTE Use Dell EMC branded SD cards that are associated with the IDSDM configured systems.

Video specifications

The PowerEdge R350 system supports integrated Matrox G200 graphics controller with 16 MB of video frame buffer.
Table 1. Supported video resolution options This table describes the supported rear video resolution options for the system.
Resolution Refresh rate (Hz) Color depth (bits)
1024 x 768 60, 72, 75, 85 8, 16, 32
1280 x 800 60, 75 8, 16, 32
1280 x 1024 60, 75, 85 8, 16, 32
1360 x 768 60 8, 16, 32
1440 x 900 60, 75, 85 8, 16, 32
1600 x 900 60 8, 16, 32
1600 x 1200 60, 65, 70, 75, 85 8, 16, 32
1680 x 1050 60, 75, 85 8, 16, 32
1920 x 1080 60 8, 16, 32
1920 x 1200 60, 75, 85 8, 16, 32

Environmental specifications

NOTE For additional information about environmental certifications, see the Product Environmental Datasheet located with the Documentation on www.dell.com/support/home.
Table 1. Continuous Operation Specifications for ASHRAE A2 This table describes the operational climatic range for category A2.
Allowable continuous operations
Temperature range for altitudes <= 900 m (<= 2953 ft) 10–35°C (50–95°F) with no direct sunlight on the equipment
Humidity percent range (non-condensing at all times) 8% RH with -12°C minimum dew point to 80% RH with 21°C (69.8°F) maximum dew point
Operational altitude de-rating Maximum temperature is reduced by 1°C/300 m (33.8°F/984 Ft) above 900 m (2953 Ft)
Table 2. Continuous Operation Specifications for ASHRAE A3 This table describes the operational climatic range for category A3.
Allowable continuous operations
Temperature range for altitudes <= 900 m (<= 2953 ft) 5–40°C (41–104°F) with no direct sunlight on the equipment
Humidity percent range (non-condensing at all times) 8% RH with -12°C minimum dew point to 85% RH with 24°C (75.2°F) maximum dew point
Operational altitude de-rating Maximum temperature is reduced by 1°C/175 m (33.8°F/574 Ft) above 900 m (2953 Ft)
Table 3. Continuous Operation Specifications for ASHRAE A4 This table describes the operational climatic range for category A4.
Allowable continuous operations

Temperature range for altitudes <= 900 m (<= 2953 ft)

5–45°C (41–113°F) with no direct sunlight on the equipment
Humidity percent range (non-condensing at all times) 8% RH with -12°C minimum dew point to 90% RH with 24°C (75.2°F) maximum dew point
Operational altitude de-rating Maximum temperature is reduced by 1°C/125 m (33.8°F/410 Ft) above 900 m (2953 Ft)
Table 4. Common Environmental Specifications for ASHRAE A2, A3, A4 This table describes the shared requirements across all categories.
Allowable continuous operations
Maximum temperature gradient (applies to both operation and non-operation) 20°C in an hour* (36°F in an hour) and 5°C in 15 minutes (41°F in 15 minutes), 5°C in an hour* (41°F in an hour) for tape
NOTE * - Per ASHRAE thermal guidelines for tape hardware, these are not instantaneous rates of temperature change.
Non-operational temperature limits -40 to 65°C (-104 to 149°F)
Non-operational humidity limits 5% to 95% RH with 27°C (80.6°F) maximum dew point
Maximum non-operational altitude 12,000 meters (39,370 feet)
Maximum operational altitude 3,048 meters (10,000 feet)
Table 5. Maximum vibration specificationsThe maximum vibration specification of an operational system is 0.26 Grms at 5 Hz to 350 Hz (all operation orientations).The maximum vibration specification of a nonoperational system is 1.88 Grms at 10 Hz to 500 Hz for 15 minutes (all six sides tested).
Maximum vibration Specifications
Operating 0.26 Grms at 5 Hz to 350 Hz (all operation orientations)
Storage 1.88 Grms at 10 Hz to 500 Hz for 15 minutes (all six sides tested)
Table 6. Maximum shock pulse specificationsThe maximum shock specification of an operational system is six consecutively executed shock pulses in the positive and negative x, y, and z axis of 40 G for up to 2.3 ms. The maximum shock specification of a nonoperational system is six consecutively executed shock pulses in the positive and negative x, y, and z axis (one pulse on each side of the system) of 71 G for up to 2 ms.
Maximum shock pulse Specifications
Operating Six consecutively executed shock pulses in the positive and negative x, y, and z axis of 6 G for up to 11 ms.
Storage Six consecutively executed shock pulses in the positive and negative x, y, and z axis (one pulse on each side of the system) of 71 G for up to 2 ms.

Particulate and gaseous contamination specifications

The following table defines the limitations that help avoid any damages to the IT equipment and/or, or both failure from particulate and gaseous contamination. If the levels of particulate or gaseous pollution exceed the specified limitations and results in equipment damage or failure, you must rectify the environmental conditions. Remediation of environmental conditions is the responsibility of the customer.
Table 1. Particulate contamination specifications Air filtration specification: Data center air filtration as defined by ISO Class 8 per ISO 14644-1 should have a 95% upper confidence limit. This condition applies only to data center environments. Air filtration requirements do not apply to IT equipment designed to be used outside a data center, in environments such as an office or factory floor. Air entering the data center must have MERV11 or MERV13 filtration. Conductive dust specification: Air must be free of conductive dust, zinc whiskers, or other conductive particles. This condition applies to data center and non-data center environments. Corrosive dust specification: Air must be free of corrosive dust. Residual dust present in the air must have a deliquescent point less than 60% relative humidity. This condition applies to data center and non-data center environments.
Particulate contamination Specifications
Air filtration Data center air filtration as defined by ISO Class 8 per ISO 14644-1 with a 95% upper confidence limit.
NOTE This condition applies to data center environments only. Air filtration requirements do not apply to IT equipment designed to be used outside a data center, in environments such as an office or factory floor.
NOTE Air entering the data center must have MERV11 or MERV13 filtration.
NOTE Air filtering can also be accomplished by filtering room air with MERV8 filter per ANSI/ASHRAE Standard 127
Conductive dust Air must be free of conductive dust, zinc whiskers, or other conductive particles.
NOTE This condition applies to data center and non-data center environments.
NOTE Common sources of conductive dust include manufacturing processes, and zinc whiskers from the plating on the bottom of raised floor tiles
Corrosive dust
  • Air must be free of corrosive dust.
  • Residual dust present in the air must have a deliquescent point less than 60% relative humidity.
NOTE This condition applies to data center and non-data center environments.
Table 2. Gaseous contamination specifications The copper coupon corrosion rate is <300 Å/month per Class G1 as defined by ANSI/ISA71.04-2013. The silver coupon corrosion rate is <200 Å/month as defined by ANSI/ISA71.04-2013.
Gaseous contamination Specifications
Copper Coupon Corrosion rate <300 Å/month per Class G1 as defined by ANSI/ISA71.04-2013
Silver Coupon Corrosion rate <200 Å/month as defined by ANSI/ISA71.04-2013
NOTE Maximum corrosive contaminant levels measured at ≤50% relative humidity.

Thermal air restrictions

ASHRAE A3/A4 environment

  • BOSS (M.2) is not supported.
  • 8 x 2.5-inch supported with capacity < 1 TB.
  • Redundant power supplies are required.
  • Non Dell qualified peripheral cards and/or peripheral cards greater than 25 W are not supported.