Dell EMC PowerEdge R350: технические характеристики и спецификации
Chassis dimensions
Figure 1. Chassis dimensions
Table 1. PowerEdge R350 chassis dimensionsThis table provides the dimensions of the system:
Drives
Xa
Xb
Y
Za
Zb
Zc
4 x 3.5-inch
482.0 mm (18.98 inches)
434.0 mm (17.09 inches)
42.8 mm (1.7 inches)
35.64 mm (1.40 inches)With bezel
22.0 mm (0.86 inches)Without bezel
534.59 mm (21.04 inches)
Ear to rear wall
563.3 mm (22.18 inches)
Ear to PSU handle
8 x 2.5-inch
482.0 mm (18.98 inches)
434.0 mm (17.09 inches)
42.8 mm (1.7 inches)
35.64 mm (1.40 inches)With bezel
22.0 mm (0.86 inches)Without bezel
483.82 mm (19.04 inches)Ear to rear wall
512.53 mm (20.17 inches)Ear to PSU handle
NOTE Zb is the nominal rear wall external surface where the system board I/O connectors reside.
System weight
Table 1. PowerEdge R350 system weightThe table below shows the maximum weight of the system.
System configuration
Maximum weight (with all drives/SSDs)
4 x 3.5-inch
13.14 kg (28.96 pound)
8 x 2.5-inch
11.74 kg (25.88 pound)
Processor specifications
Table 1. PowerEdge R350 processor specifications This table provides processor specifications for the system.
Supported processor
Number of processors supported
Intel Xeon E-2300 series processorwith up to 8 cores
One
PSU specifications
The PowerEdge R350 system supports up to two AC power supply units (PSUs).
Table 1. PSU specifications This table describes PSU specifications for the system.
PSU
Class
Heat dissipation (maximum)
Frequency
Voltage
AC
DC Input
AC Current
DC Current
High line 200–240 V
Low line 100–120 V
600 W
AC
Platinum
2250 BTU/hr
50/60 Hz
100 - 240 V,
autoranging
600 W
600 W
240 VDC
7.1 - 3.6 A
2.9 A
NOTE This system is also designed to connect to the IT power systems with a phase-to-phase voltage not exceeding 240 V.
NOTE Heat dissipation is calculated using the PSU wattage rating.
NOTE When selecting or upgrading the system configuration, to ensure optimum power utilization, verify the system power consumption with the Enterprise Infrastructure Planning Tool available at
Dell.com/calc.
Cooling fans specifications
The
PowerEdgeR350system supports up to four non hot plug system fans connected to the system board.
NOTE For more information about the fan support configuration or matrix, see Thermal restriction matrix.
Supported operating systems
The
PowerEdgeR350system supports the following operating systems:
Canonical Ubuntu Server LTS
VMware ESXi
Microsoft Windows Server with Hyper-V
Red Hat Enterprise Linux
SUSE Linux Enterprise Server
For more information, go to
www.dell.com/ossupport.
System battery specifications
The PowerEdge R350 system
supports
CR 2032 3.0-V lithium coin cell system battery.
Expansion card riser specifications
The PowerEdge R350 system supports up to three PCI express (PCIe) Gen 4 expansion cards.
Table 1. Expansion card slots supported on the system boardThis table provides information about the expansion card slots that are supported on the system.
PCIe slot
Form factor
Processor
PCIe slot bandwidth
PCIe slot connector
Slot 1
Half Height
Processor 1
Gen4 x8 lanes
x8
Slot 2
Half Height
Processor 1
Gen4 x8 lanes
x16
Internal
Half Length
Processor 1
Gen4 x4 lanes
x8
Table 2. Riser Configuration 0This table provides information for riser configuration 0 supported on the system.
PCIe slot
Risers
Riser width
PCIe slot height
PCIe slot length
PCIe slot width
Slot 1
Butterfly Riser
Single Wide
Half Height
Half Length
x8
Slot 2
Butterfly Riser
Single Wide
Half Height
Half Length
x8
Internal
NA
Single Wide
Half Height
Half Length
x4
Memory specifications
The PowerEdge R350 system supports the following memory specifications for optimized operation.
Table 1. Memory specificationsThe table below shows the memory specifications:
DIMM type
DIMM rank
DIMM capacity
Single processor
Minimum system capacity
Maximum system capacity
UDIMM
Single rank
8 GB
8 GB
32 GB
16 GB
16 GB
64 GB
Dual rank
32 GB
32 GB
128 GB
Table 2. Memory module socketsThe table below shows the memory module sockets for the system:
Memory module sockets
Speed
4, 288-pin
3200 MT/s, 2933 MT/s, 2666 MT/s
NOTE Memory DIMM slots are not hot pluggable.
NOTE Pentium processors support up to 2666 MT/s only. All channels in a system run at the fastest common frequency.
NOTE Using dual rank UDIMMs with two DIMMs per channel (2DPC) limits the speed to 2933 MT/s.
Storage controller specifications
The PowerEdge R350 system supports the following controller cards:
Table 1. Storage controller cards This table provides the controller cards supported on the system:
Internal controllers
External controllers
PERC H355
PERC H355f
PERC H345
PERC H755
HBA355i
PERC H345f
PERC H755f
HBA355f
HBA355e
Drives
The PowerEdge R350 system
supports:
4 x 3.5-inch hot-swappable
SAS,
SATA drives.
8 x 2.5-inch hot-swappable
SAS,
SATA drives.
Max 80TB for 4 HDD configurations
Optical drives
The PowerEdge R350 system supports one
Slim SATA DVD-ROM drive or
DVD +/- RW drive.
NOTE DVD devices support only data.
NIC port specifications
The PowerEdge R350 system supports up to two 10/100/1000 Mbps Network Interface Controller (NIC) ports embedded on Motherboard.
Table 1. NIC port specification for the systemThis table describes the NIC port specification for the system.
Feature
Specifications
LOM
1 GB x 2
Serial connector specifications
The PowerEdge R350
system supports
serial connector, which is a
9-pin connector,
Data Terminal Equipment (DTE),
16550-compliant
.
USB ports specifications
Table 1. PowerEdge R350 USB specificationsThe following table shows the USB specifications for the system:
Front
Rear
Internal (Optional)
USB port type
No. of ports
USB port type
No. of ports
USB port type
No. of ports
USB 2.0-compliant port
One
USB 3.0-compliant port
One
Internal USB 3.0-compliant port
One
iDRAC Direct port (Micro-AB USB 2.0-compliant port)
One
USB 2.0-compliant port
One
NOTE The micro USB 2.0 compliant port can only be used as an iDRAC Direct or a management port.
VGA ports specifications
The PowerEdge R350 system supports
One DB-15 VGA port on back panel.
IDSDM
The PowerEdge R350 system
supports Internal Dual SD module (IDSDM).
The IDSDM supports two SD cards and is available in the following configurations:
Table 1. Supported SD card storage capacityThis table lists the storage capacity of the supported SD cards
IDSDM card
16 GB
32 GB
64 GB
NOTE One IDSDM card slot is dedicated for redundancy.
NOTE Use Dell EMC branded SD cards that are associated with the IDSDM configured systems.
Video specifications
The
PowerEdgeR350 system supports integrated Matrox G200 graphics controller with 16 MB of video frame buffer.
Table 1. Supported video resolution options This table describes the supported rear video resolution options for the system.
Resolution
Refresh rate (Hz)
Color depth (bits)
1024 x 768
60, 72, 75, 85
8, 16, 32
1280 x 800
60, 75
8, 16, 32
1280 x 1024
60, 75, 85
8, 16, 32
1360 x 768
60
8, 16, 32
1440 x 900
60, 75, 85
8, 16, 32
1600 x 900
60
8, 16, 32
1600 x 1200
60, 65, 70, 75, 85
8, 16, 32
1680 x 1050
60, 75, 85
8, 16, 32
1920 x 1080
60
8, 16, 32
1920 x 1200
60, 75, 85
8, 16, 32
Environmental specifications
NOTE For additional information about environmental certifications, see the
Product Environmental Datasheet located with the
Documentation on
www.dell.com/support/home.
Table 1. Continuous Operation Specifications for ASHRAE A2 This table describes the operational climatic range for category A2.
Allowable continuous operations
Temperature range for altitudes <= 900 m (<= 2953 ft)
10–35°C (50–95°F) with no direct sunlight on the equipment
Humidity percent range (non-condensing at all times)
8% RH with -12°C minimum dew point to 80% RH with 21°C (69.8°F) maximum dew point
Operational altitude de-rating
Maximum temperature is reduced by 1°C/300 m (33.8°F/984 Ft) above 900 m (2953 Ft)
Table 2. Continuous Operation Specifications for ASHRAE A3 This table describes the operational climatic range for category A3.
Allowable continuous operations
Temperature range for altitudes <= 900 m (<= 2953 ft)
5–40°C (41–104°F) with no direct sunlight on the equipment
Humidity percent range (non-condensing at all times)
8% RH with -12°C minimum dew point to 85% RH with 24°C (75.2°F) maximum dew point
Operational altitude de-rating
Maximum temperature is reduced by 1°C/175 m (33.8°F/574 Ft) above 900 m (2953 Ft)
Table 3. Continuous Operation Specifications for ASHRAE A4 This table describes the operational climatic range for category A4.
Allowable continuous operations
Temperature range for altitudes <= 900 m (<= 2953 ft)
5–45°C (41–113°F) with no direct sunlight on the equipment
Humidity percent range (non-condensing at all times)
8% RH with -12°C minimum dew point to 90% RH with 24°C (75.2°F) maximum dew point
Operational altitude de-rating
Maximum temperature is reduced by 1°C/125 m (33.8°F/410 Ft) above 900 m (2953 Ft)
Table 4. Common Environmental Specifications for ASHRAE A2, A3, A4 This table describes the shared requirements across all categories.
Allowable continuous operations
Maximum temperature gradient (applies to both operation and non-operation)
20°C in an hour* (36°F in an hour) and 5°C in 15 minutes (41°F in 15 minutes), 5°C in an hour* (41°F in an hour) for tape
NOTE * - Per ASHRAE thermal guidelines for tape hardware, these are not instantaneous rates of temperature change.
Non-operational temperature limits
-40 to 65°C (-104 to 149°F)
Non-operational humidity limits
5% to 95% RH with 27°C (80.6°F) maximum dew point
Maximum non-operational altitude
12,000 meters (39,370 feet)
Maximum operational altitude
3,048 meters (10,000 feet)
Table 5. Maximum vibration specificationsThe maximum vibration specification of an operational system is 0.26 Grms at 5 Hz to 350 Hz (all operation orientations).The maximum vibration specification of a nonoperational system is 1.88 Grms at 10 Hz to 500 Hz for 15 minutes (all six sides tested).
Maximum vibration
Specifications
Operating
0.26 Grms at 5 Hz to 350 Hz (all operation orientations)
Storage
1.88 Grms at 10 Hz to 500 Hz for 15 minutes (all six sides tested)
Table 6. Maximum shock pulse specificationsThe maximum shock specification of an operational system is six consecutively executed shock pulses in the positive and negative x, y, and z axis of 40 G for up to 2.3 ms. The maximum shock specification of a nonoperational system is six consecutively executed shock pulses in the positive and negative x, y, and z axis (one pulse on each side of the system) of 71 G for up to 2 ms.
Maximum shock pulse
Specifications
Operating
Six consecutively executed shock pulses in the positive and negative x, y, and z axis of 6 G for up to 11 ms.
Storage
Six consecutively executed shock pulses in the positive and negative x, y, and z axis (one pulse on each side of the system) of 71 G for up to 2 ms.
Particulate and gaseous contamination specifications
The following table defines the limitations that help avoid any damages to the IT equipment and/or, or both failure from particulate and gaseous contamination. If the levels of particulate or gaseous pollution exceed the specified limitations and results in equipment damage or failure, you must rectify the environmental conditions. Remediation of environmental conditions is the responsibility of the customer.
Table 1. Particulate contamination specifications Air filtration specification: Data center air filtration as defined by ISO Class 8 per ISO 14644-1 should have a 95% upper confidence limit. This condition applies only to data center environments. Air filtration requirements do not apply to IT equipment designed to be used outside a data center, in environments such as an office or factory floor. Air entering the data center must have MERV11 or MERV13 filtration. Conductive dust specification: Air must be free of conductive dust, zinc whiskers, or other conductive particles. This condition applies to data center and non-data center environments. Corrosive dust specification: Air must be free of corrosive dust. Residual dust present in the air must have a deliquescent point less than 60% relative humidity. This condition applies to data center and non-data center environments.
Particulate contamination
Specifications
Air filtration
Data center air filtration as defined by ISO Class 8 per ISO 14644-1 with a 95% upper confidence limit.
NOTE This condition applies to data center environments only. Air filtration requirements do not apply to IT equipment designed to be used outside a data center, in environments such as an office or factory floor.
NOTE Air entering the data center must have MERV11 or MERV13 filtration.
NOTE Air filtering can also be accomplished by filtering room air with MERV8 filter per ANSI/ASHRAE Standard 127
Conductive dust
Air must be free of conductive dust, zinc whiskers, or other conductive particles.
NOTE This condition applies to data center and non-data center environments.
NOTE Common sources of conductive dust include manufacturing processes, and zinc whiskers from the plating on the bottom of raised floor tiles
Corrosive dust
Air must be free of corrosive dust.
Residual dust present in the air must have a deliquescent point less than 60% relative humidity.
NOTE This condition applies to data center and non-data center environments.
Table 2. Gaseous contamination specifications The copper coupon corrosion rate is <300 Å/month per Class G1 as defined by ANSI/ISA71.04-2013. The silver coupon corrosion rate is <200 Å/month as defined by ANSI/ISA71.04-2013.
Gaseous contamination
Specifications
Copper Coupon Corrosion rate
<300 Å/month per Class G1 as defined by ANSI/ISA71.04-2013
Silver Coupon Corrosion rate
<200 Å/month as defined by ANSI/ISA71.04-2013
NOTE Maximum corrosive contaminant levels measured at ≤50% relative humidity.
Thermal air restrictions
ASHRAE A3/A4 environment
BOSS (M.2) is not supported.
8 x 2.5-inch supported with capacity < 1 TB.
Redundant power supplies are required.
Non Dell qualified peripheral cards and/or peripheral cards greater than 25 W are not supported.