Dell EMC PowerEdge R250: технические характеристики и спецификации
Chassis dimensions
Figure 1. PowerEdgeR250 Chassis dimensions
Table 1. Chassis dimensionsThis table provides the dimensions of the
PowerEdgeR250system:
Drives
Xa
Xb
Y
Za
Zb
Zc
4 x 3.5-inch and 2 x 3.5-inch
482 mm (18.976 inches)
434 mm (17.08 inches)
42.8 mm(1.685 inches)
22 mm (0.866 inches) without bezel
35.64 mm (1.40 inches) with bezel
534.59 mm (21.04 inches)
(Ear to PSU surface)
563 mm (22.16 inches)
NOTE:Zb is the nominal rear wall external surface where the system board I/O connectors reside.
System weight
Table 1. PowerEdgeR250 system weight The table below shows the maximum weight of the
PowerEdgeR250system.
System configuration
Maximum weight (with all drives/SSDs)
4 x 3.5-inch system
2 x 3.5-inch system
12.48 kg (27.51 lbs.)
Processor specifications
Table 1. PowerEdgeR250 processor specifications This table provides processor specifications for the system.
Supported processor
Number of processors supported
Intel Xeon E-2300 series processor with up to 8 cores per processor
One
NOTE:Note: For Pentium processor, maximum memory speed supported is 2666 MT/s.
PSU specifications
The
PowerEdgeR250system supports one AC cabled power supply unit (PSU).
Table 1. PowerEdgeR250 PSU specificationsThe table lists the specifications for 450 W, and 450 W cabled power supplies.
PSU
Class
Heat dissipation (maximum)
Frequency
Voltage
AC
DC Input
AC Current
DC Current
High line 200–240 V
Low line 100–120 V
450 W
Bronze
1871 BTU/hr
50/60 Hz
100–240 V AC, autoranging
450 W
450 W
N/A
6.5 A-3.5 A
N/A
450 W
Platinum
1725 BTU/hr
50/60 Hz
100–240 V AC, autoranging
450 W
450 W
N/A
6.5 A-3.5 A
N/A
700 W
Titanium
2625 BTU/hr
50/60 Hz
200–240 V AC, autoranging
700 W
N/A
240 V DC
4.1 A
3.4 A
NOTE:Heat dissipation is calculated using the PSU wattage rating.
NOTE:When selecting or upgrading the system configuration, to ensure optimum power utilization, verify the system power consumption with the Enterprise Infrastructure Planning Tool available at
Dell.com/calc.
Supported operating systems
The
PowerEdgeR250system supports the following operating systems:
Canonical Ubuntu Server LTS
VMware ESXi
Microsoft Windows Server with Hyper-V
SUSE Linux Enterprise Server
Red Hat Enterprise Linux
For more information, go to
Operating System Manuals.
Cooling fans specifications
The
PowerEdgeR250system supports up to three non hot plug system fans and one optional non hot plug PCIe fan connected to the system board.
NOTE: For more information about the fan support configuration or matrix, see Thermal restriction matrix.
System battery specifications
The
PowerEdgeR250system supports
CR 2032 3.0-V lithium coin cell system battery.
Expansion card riser specifications
The
PowerEdgeR250system supports up to two PCI express (PCIe) Gen 4 expansion cards.
Table 1. Expansion card slots supported on the system boardThis table provides information about the expansion card slots that are supported on the system.
PCIe slot
Form factor
Processor
PCIe slot bandwidth
PCIe slot connector
Slot 1
Half Height
Processor 1
Gen4 x8 lanes
x8
Slot 2
Half Height
Processor 1
Gen4 x8 lanes
x16
Table 2. Riser Configuration 0This table provides information for riser configuration 0 supported on the system.
PCIe slot
Risers
Riser width
PCIe slot height
PCIe slot length
PCIe slot width
Slot 1
Butterfly Riser
Single Wide
Half Height
Half Length
x8
Slot 2
Butterfly Riser
Single Wide
Half Height
Half Length
x8
NOTE: For information on the expansion card installation guidelines, see the system specific
Installation and Service Manual available on the
PowerEdge Manuals.
Memory specifications
The
PowerEdgeR250system supports the following memory specifications for optimized operation.
Table 2. Memory module socketsThe table below shows the memory module sockets for the system:
Memory module sockets
Speed
4, 288-pin
3200 MT/s, 2933 MT/s, 2666 MT/s
NOTE:Memory DIMM slots are not hot pluggable.
NOTE:Pentium processors support up to 2666 MT/s only. All channels in a system run at the fastest common frequency.
NOTE:Using dual rank UDIMMs with two DIMMs per channel (2DPC) limits the speed to 2933 MT/s.
Storage controller specifications
The
PowerEdgeR250system supports the following controller cards:
Table 1. PowerEdgeR250 storage controller cardsThis table provides the controller cards supported on the system:
Internal controllers
External controllers
H345
H355
H755
HBA355i
S150
HBA355e
Drives
The
PowerEdgeR250system supports:
4 x 3.5-inch non-hot plug
SAS,
SATA (HDD/SSD) drives.
4 x 3.5-inch hot plug
SAS,
SATA drives
2 x 3.5-inch cabled
SAS,
SATA drives
USB ports specifications
Table 1. PowerEdgeR250 USB ports specifications The following table shows the
PowerEdgeR250 USB ports specifications :
Front
Rear
Internal (Optional)
USB port type
No. of ports
USB port type
No. of ports
USB port type
No. of ports
USB 2.0-compliant port
One
USB 3.0 port
One
Internal USB 3.0-compliant port
One
iDRAC Direct port (Micro-AB USB 2.0-compliant port)
One
USB 2.0 port
One
NOTE:The micro USB 2.0 compliant port can only be used as an iDRAC Direct or a management port.
NIC port specifications
The
PowerEdgeR250system supports up to two 10/100/1000 Mbps Network Interface Controller (NIC) ports embedded on the Motherboard.
Table 1. NIC port specification for the systemThis table describes the NIC port specification for the system.
Feature
Specifications
LOM
Onboard LOM 1GbE x2
Serial connector specifications
The
PowerEdgeR250system
supports one serial connector on rear of the system, which is a
9-pin connector,
Data Terminal Equipment (DTE),
16550-compliant
.
VGA ports specifications
The
PowerEdgeR250system supports one
DB-15 VGA port on the rear panel of the system.
IDSDM
The
PowerEdgeR250system supports Internal Dual SD module (IDSDM).
The IDSDM supports two SD cards and is available in the following configurations:
Table 1. Supported SD card storage capacityThis table lists the storage capacity of the supported SD cards
IDSDM card
16 GB
32 GB
64 GB
NOTE:One IDSDM card slot is dedicated for redundancy.
NOTE:Use Dell EMC branded SD cards that are associated with the IDSDM configured systems.
Environmental specifications
NOTE:For additional information about environmental certifications, refer to the
Product Environmental Datasheet located with the Documentation > Regulatory Information on
Dell Support.
Table 1. Operational climatic range category A2 This table describes the operational climatic range for category A2.
Temperature
Specifications
Allowable continuous operations
Temperature ranges for altitudes <= 900 m (<= 2953 ft)
10–35°C (50–95°F) with no direct sunlight on the equipment
Humidity percent ranges (non-condensing at all times)
8% RH with -12°C minimum dew point to 80% RH with 21°C (69.8°F) maximum dew point
Operational altitude de-rating
Maximum temperature is reduced by 1°C/300 m (1.8°F/984 Ft) above 900 m (2953 Ft)
Table 2. Shared requirements across all categories This table describes the shared requirements across all categories.
Temperature
Specifications
Allowable continuous operations
Maximum temperature gradient (applies to both operation and non-operation)
20°C in an hour* (36°F in an hour) and 5°C in 15 minutes (9°F in 15 minutes), 5°C in an hour* (9°F in an hour) for tape
NOTE:* - Per ASHRAE thermal guidelines for tape hardware, these are not instantaneous rates of temperature change.
Non-operational temperature limits
-40 to 65°C (-40 to 149°F)
Non-operational humidity limits
5% to 95% RH with 27°C (80.6°F) maximum dew point
Maximum non-operational altitude
12,000 meters (39,370 feet)
Maximum operational altitude
3,048 meters (10,000 feet)
Table 3. Maximum vibration specifications
Maximum vibration
Specifications
Operating
0.21 Grms at 5 Hz to 500 Hz for 10 minutes (all x, y, and z axis)
Storage
1.88 G
rms at 10 Hz to 500 Hz for 15 minutes (all six sides tested)
Table 4. Maximum shock pulse specificationsThe maximum shock specification of an operational system is six consecutively executed shock pulses in the positive and negative x, y, and z axis of 6 G for up to 11 ms. The maximum shock specification of a nonoperational system is six consecutively executed shock pulses in the positive and negative x, y, and z axis (one pulse on each side of the system) of 71 G for up to 2 ms.
Maximum shock pulse
Specifications
Operating
Six consecutively executed shock pulses in the positive and negative x, y, and z axis of 6 G for up to 11 ms. Six consecutively executed shock pulses in the positive and negative x, y, and z axis of 6G for up to 11ms.
Storage
Six consecutively executed shock pulses in the positive and negative x, y, and z axis (one pulse on each side of the system) of 71 G for up to 2 ms
Particulate and gaseous contamination specifications
The following table defines the limitations that prevent the damage to the IT equipment and/or, or both failure from particulate and gaseous contamination. If the levels of particulate or gaseous pollution exceed the specified limitations and results in equipment damage or failure, you must rectify the environmental conditions. Remediation of environmental conditions is the responsibility of the customer.
Table 1. Particulate contamination specifications Air filtration specification: Data center air filtration as defined by ISO Class 8 per ISO 14644-1 should have a 95% upper confidence limit. This condition applies only to data center environments. Air filtration requirements do not apply to IT equipment designed to be used outside a data center, in environments such as an office or factory floor. Air entering the data center must have MERV11 or MERV13 filtration. Conductive dust specification: Air must be free of conductive dust, zinc whiskers, or other conductive particles. This condition applies to data center and non-data center environments. Corrosive dust specification: Air must be free of corrosive dust. Residual dust present in the air must have a deliquescent point less than 60% relative humidity. This condition applies to data center and non-data center environments.
Particulate contamination
Specifications
Air filtration
Data center air filtration as defined by ISO Class 8 per ISO 14644-1 with a 95% upper confidence limit.
NOTE:This condition applies to data center environments only. Air filtration requirements do not apply to IT equipment designed to be used outside a data center, in environments such as an office or factory floor.
NOTE:Air entering the data center must have MERV11 or MERV13 filtration.
Conductive dust
Air must be free of conductive dust, zinc whiskers, or other conductive particles.
NOTE:This condition applies to data center and non-data center environments.
Corrosive dust
Air must be free of corrosive dust.
Residual dust present in the air must have a deliquescent point less than 60% relative humidity.
NOTE:This condition applies to data center and non-data center environments.
Table 2. Gaseous contamination specifications The copper coupon corrosion rate is <300 Å/month per Class G1 as defined by ANSI/ISA71.04-2013. The silver coupon corrosion rate is <200 Å/month as defined by ANSI/ISA71.04-2013.
Gaseous contamination
Specifications
Copper Coupon Corrosion rate
<300 Å/month per Class G1 as defined by ANSI/ISA71.04-2013
Silver Coupon Corrosion rate
<200 Å/month as defined by ANSI/ISA71.04-2013
NOTE:Maximum corrosive contaminant levels measured at ≤50% relative humidity.
Thermal restrictions
Four fans population is required.
Non Dell qualified peripheral cards or peripheral cards greater than 25 W are not supported.