Physical specifications
This section describes the dimensions and weight of the system.

| Description | Dimension |
|---|---|
| Physical dimensions | |
| Xa | 482.0 mm (18.98 inches) |
| Xb | 434.0 mm (17.08 inches) |
| Y | 42.8 mm (1.68 inches) |
| Za (with bezel) | 35.64 mm (1.4 inches) |
| Za (without bezel) | 22.0 mm (0.87 inches) |
| Zb | 534.5 mm (21.04 inches) |
| Zc | 573.6 mm (22.58 inches) |
| Weight | |
| Maximum weight (with all drives) | 13.2 kg (29.10 lb) |
Processor specifications
| Supported processor | Number of processors supported |
|---|---|
| Intel Xeon E-2124 3.3GHz, 4C, 8M Cache | One |
Power specifications
The NX440 system supports two redundant power supply units. The following specifications are for each PSU.
| Power Supply Unit (PSU) | |
|---|---|
| Maximum output power | 350 W |
| Maximum input current | 4.8-2.4 A |
| Nominal input voltage operating range | 100–240 VAC |
| Nominal input frequency | 50/60 Hz |
| Heat dissipation (maximum) | 1340 BTU/hr |
Cooling fan specifications
The NX440 supports the following cooling fans.
| Front storage | PSU type | Fan 1 | Fan 2 | Fan 3 | Fan 4 |
|---|---|---|---|---|---|
| 4 x 3.5-inch | Redundant 350 W | Required, if the PERC card and/or expansion riser is installed | Required | Required | Required |
System battery specifications
The NX440 contains one CR 2032 3.0-V lithium coin cell battery.
Expansion bus specifications
The NX440 NAS system supports up to two PCI express (PCIe) generation 3 cards.
| PCIe slot | Riser | PCIe slot height | PCIe slot length | Slot width |
|---|---|---|---|---|
| Slot 1 | x8 PCIe | Low-profile | Half-length | x4 |
| Slot 2 | x16 PCIe | Low-profile/Full height | Half-length | x8 |
Memory specifications
The NX440 supports up to four 288-pin UDIMMS with a speed of either 3200 MT/s or 2666 MT/s.
Memory
| DIMM type | DIMM rank | DIMM capacity | Minimum RAM | Maximum RAM |
|---|---|---|---|---|
| UDIMM | Single rank | 8 GB | 8 GB | 8 GB |
| Single rank | 16 GB | 16 GB | 16 GB |
Storage controller specifications
The NX440 contains one internal storage controller card and supports external storage using a SAS HBA.
- Internal controller — PERC H730P mini
- External storage — 12 Gb SAS Host Bus Adapter card
Drive specifications
The NX440 system supports SAS and SATA drives and an optical DVD.
| Internal drives | |
| 4 x 3.5-inch hot-swappable | SAS or SATA |
|
NOTE Solid State Drives (SSDs) are supported, but must be ordered in a separate kit.
|
|
| External storage | |
| MD1400, MD1420 | 12 Gb JBOD |
| ME484 | 12 Gb JBOD |
| ML3 | Tape |
| ML3E | Tape |
| Optical LTO external drive, PV114x, TL1000 Tape | |
| One DVD-ROM drive or DVD +/-RW drive | SATA |
Ports and connectors specifications
The NX440 system supports USB ports, NIC ports, VGA ports, and a serial connector.
USB ports
The NX440 supports both USB 2.0 and USB 3.0-compliant ports.
| Location | Type | Quantity |
|---|---|---|
| Front panel | USB 2.0-compliant port | One |
| Front panel | Micro USB 2.0-compliant port for iDRAC Direct | One |
| Back panel | USB 3.0-compliant port | Two |
| Internal | USB 3.0-compliant port | One |
NIC ports
The NX440 system supports two 1 GbE/10 GbE Network Interface Controller (NIC) ports on the back panel.
Serial connector
VGA ports
Video specifications
The NX440 system supports the Integrated Matrox G200 graphics controller with 16 MB of video frame buffer.
| Resolution | Refresh Rate (Hz) | Color Depth (bit) |
|---|---|---|
| 640 x 480 | 60, 70 | 8, 16, 24 |
| 800 x 600 | 60, 75, 85 | 8, 16, 24 |
| 1024 x 768 | 60, 75, 85 | 8, 16, 24 |
| 1152 x 864 | 60, 75, 85 | 8, 16, 24 |
| 1280 x 1024 | 60, 75 | 8, 16, 24 |
Environmental specifications
For additional information about environmental measurements for specific system configurations, see dell.com/environmental_datasheets.
| Temperature | |
| Operating (Continuous, for altitude less than 950 m or 3117 ft) | 10°C to 35°C (50°F to 95°F) with no direct sunlight on the equipment. |
| Storage | –40° to 65°C (–40° to 149°F) at a maximum altitude of 12,000 m (39,370 ft) |
| Fresh Air | For information on fresh air, see Expanded Operating Temperature section. |
| Maximum temperature gradient (operating and storage) | 20°C/h (68°F/h) |
| Relative humidity | |
| Operating | 10% to 80% (noncondensing) with 29°C (84.2°F) maximum dew point |
| Storage | 5% to 95% (noncondensing) with 33°C (91°F) maximum dew point |
| Maximum vibration | |
| Operating | 0.26 Grms at 5–350 Hz (all operation orientation) |
| Storage | 1.88 Grms at 10–500 Hz for 15 min (all six sides tested) |
| Maximum shock | |
| Operating | Six consecutively executed shock pulses in the positive and negative x, y, and z axes of 40 G for up to 2.3 ms |
| Storage | Six consecutively executed shock pulses in the positive and negative x, y, and z axes (one pulse on each side of the system) of 71 G for up to 2 ms |
| Altitude | |
| Operating | 3,048 m (10,000 ft) |
| Storage | 12,000 m (39,370 ft) |
| Operating temperature de-rating | |
| Up to 35 °C (95 °F) | Maximum temperature is reduced by 1°C/300 m (33.8°F/984.25 ft) above 950 m (3,117 ft) |
| 35 °C to 40 °C (95 °F to 104 °F) | Maximum temperature is reduced by 1°C/175 m (1°F/574.14 ft) above 950 m (3,117 ft). |
| 40 °C to 45 °C (104 °F to 113 °F) | Maximum temperature is reduced by 1°C/125 m (1°F/410.1 ft) above 950 m (3,117 ft) |
Expanded operating temperature
| Expanded operating temperature | Specifications |
|---|---|
| Continuous operation | 5°C to 40°C at 5% to 85% RH with 29°C dew point.
NOTE Outside the standard operating temperature (10°C to 35°C), the system can operate continuously in temperatures as low as 5°C and as high as 40°C.
For temperatures between 35°C to 40°C, de-rate maximum allowable temperature by 1°C per 175 m above 950 m (1°F per 319 ft). |
| ≤ 1% of annual operating hours | –5°C to 45°C at 5% to 90% RH with 29°C dew point.
NOTE Outside the standard operating temperature (10°C to 35°C), the system can operate down to –5°C or up to 45°C for a maximum of 1% of its annual operating hours.
For temperatures between 40°C and 45°C, de-rate maximum allowable temperature by 1°C per 125 m above 950 m (1°F per 228 ft). |
Expanded operating temperature restrictions
- Do not perform a cold startup below 5°C.
- The operating temperature specified is for a maximum altitude of 3050 m (10,000 ft).
- 150 W/8 core, 165 W/12 core and higher wattage processor [Thermal Design Power (TDP)>165 W] are not supported.
- Redundant power supply unit is required.
- Non-Dell EMC qualified peripheral cards and/or peripheral cards greater than 25 W are not supported.
- Tape backup unit is not supported.
Particulate and gaseous contamination specifications
This section defines the limitations that help avoid any equipment damage or failure from particulate and gaseous contamination. If the levels of particulate or gaseous pollution exceed the specified limitations and result in equipment damage or failure, you may need to rectify the environmental conditions. Remediation of environmental conditions is the responsibility of the customer.
| Particulate contamination | Specifications |
|---|---|
| Air filtration | Data center air filtration as defined by ISO Class
8 per ISO 14644-1 with a 95% upper confidence limit. NOTE The ISO Class 8 condition
applies to data center environments only. This air filtration requirement
does not apply to IT equipment designed to be used outside a data
center, in environments such as an office or factory floor. NOTE Air entering the data center must have MERV11 or MERV13 filtration. |
| Conductive dust | Air must be free of conductive dust, zinc whiskers,
or other conductive particles. NOTE This condition applies
to data center and non-data center environments. |
| Corrosive dust |
NOTE This condition
applies to data center and non-data center environments. |
| Gaseous contamination | Specifications |
|---|---|
| Copper coupon corrosion rate | <300 Å/month per Class G1 as defined by ANSI/ISA71.04-2013. |
| Silver coupon corrosion rate | <200 Å/month as defined by ANSI/ISA71.04-2013. |