Dell PowerVault NX440 Network Attached Storage System: руководство по обслуживанию

Physical specifications

This section describes the dimensions and weight of the system.

Figure 1. NX440 Chassis dimensions
Description Dimension
Physical dimensions
Xa 482.0 mm (18.98 inches)
Xb 434.0 mm (17.08 inches)
Y 42.8 mm (1.68 inches)
Za (with bezel) 35.64 mm (1.4 inches)
Za (without bezel) 22.0 mm (0.87 inches)
Zb 534.5 mm (21.04 inches)
Zc 573.6 mm (22.58 inches)
Weight
Maximum weight (with all drives) 13.2 kg (29.10 lb)

Processor specifications

Supported processorNumber of processors supported
Intel Xeon E-2124 3.3GHz, 4C, 8M CacheOne

Power specifications

The NX440 system supports two redundant power supply units. The following specifications are for each PSU.

Power Supply Unit (PSU)
Maximum output power 350 W
Maximum input current 4.8-2.4 A
Nominal input voltage operating range 100–240 VAC
Nominal input frequency 50/60 Hz
Heat dissipation (maximum) 1340 BTU/hr
NOTE This system is also designed to connect to the IT power systems with a phase-to-phase voltage not exceeding 230 V.

Cooling fan specifications

The NX440 supports the following cooling fans.

NOTE When selecting or upgrading the system configuration verify the system power consumption with the Dell Energy Smart Solution Advisor available at Dell.com/ESSA to ensure optimum power usage.
This table describes the fans supported for NX440 .
Front storage PSU type Fan 1 Fan 2 Fan 3 Fan 4
4 x 3.5-inch Redundant 350 W Required, if the PERC card and/or expansion riser is installed Required Required Required

System battery specifications

The NX440 contains one CR 2032 3.0-V lithium coin cell battery.

Expansion bus specifications

The NX440 NAS system supports up to two PCI express (PCIe) generation 3 cards.

PCIe slot Riser PCIe slot height PCIe slot length Slot width
Slot 1 x8 PCIe Low-profile Half-length x4
Slot 2 x16 PCIe Low-profile/Full height Half-length x8

Memory specifications

The NX440 supports up to four 288-pin UDIMMS with a speed of either 3200 MT/s or 2666 MT/s.

Memory

The table below shows the memory specifications for the NX440 system
DIMM type DIMM rank DIMM capacity Minimum RAM Maximum RAM
UDIMM Single rank 8 GB 8 GB 8 GB
Single rank 16 GB 16 GB 16 GB

Storage controller specifications

The NX440 contains one internal storage controller card and supports external storage using a SAS HBA.

  • Internal controller — PERC H730P mini
  • External storage — 12 Gb SAS Host Bus Adapter card

Drive specifications

The NX440 system supports SAS and SATA drives and an optical DVD.

Internal drives
4 x 3.5-inch hot-swappable SAS or SATA
NOTE Solid State Drives (SSDs) are supported, but must be ordered in a separate kit.
External storage
MD1400, MD1420 12 Gb JBOD
ME484 12 Gb JBOD
ML3 Tape
ML3E Tape
Optical LTO external drive, PV114x, TL1000 Tape
One DVD-ROM drive or DVD +/-RW drive SATA

Ports and connectors specifications

The NX440 system supports USB ports, NIC ports, VGA ports, and a serial connector.

USB ports

The NX440 supports both USB 2.0 and USB 3.0-compliant ports.

Description of USB port location, type, and quantity
Location Type Quantity
Front panel USB 2.0-compliant port One
Front panel Micro USB 2.0-compliant port for iDRAC Direct One
Back panel USB 3.0-compliant port Two
Internal USB 3.0-compliant port One
NOTE The micro USB 2.0-compliant port on the front panel can only be used as an iDRAC Direct or a management port.

NIC ports

The NX440 system supports two 1 GbE/10 GbE Network Interface Controller (NIC) ports on the back panel.

Serial connector

The NX440 system supports one serial connector on the back panel. The serial port is a 9-pin connector, Data Terminal Equipment (DTE), 16550-compliant.

VGA ports

The Video Graphic Array (VGA) port enables you to connect the system to a VGA display. The NX440 system supports one 15-pin VGA port on the back panel.

Video specifications

The NX440 system supports the Integrated Matrox G200 graphics controller with 16 MB of video frame buffer.

For 640 x 480 resolution, the refresh rate is 60 to 70 Hz and the color depth is 8, 16, 24 bit. For 800 x 600 resolution, the refresh rate is 60, 75, 85 Hz and color depth is 8, 16, 24 bit. For 1024 x 768 resolution, the refresh rate is 60, 75, 85 Hz and color depth is 8, 16, 24 bit. For 1152 x 864 resolution, the refresh rate is 60, 75, 85 Hz and color depth is 8, 16, 24 bit. For 1280 x 1024 resolution, the refresh rate is 60, 75 Hz and color depth is 8, 16, 24 bit.
Resolution Refresh Rate (Hz) Color Depth (bit)
640 x 480 60, 70 8, 16, 24
800 x 600 60, 75, 85 8, 16, 24
1024 x 768 60, 75, 85 8, 16, 24
1152 x 864 60, 75, 85 8, 16, 24
1280 x 1024 60, 75 8, 16, 24

Environmental specifications

For additional information about environmental measurements for specific system configurations, see dell.com/environmental_datasheets.

List of environmental specs
Temperature
Operating (Continuous, for altitude less than 950 m or 3117 ft) 10°C to 35°C (50°F to 95°F) with no direct sunlight on the equipment.
Storage –40° to 65°C (–40° to 149°F) at a maximum altitude of 12,000 m (39,370 ft)
Fresh Air For information on fresh air, see Expanded Operating Temperature section.
Maximum temperature gradient (operating and storage) 20°C/h (68°F/h)
Relative humidity
Operating 10% to 80% (noncondensing) with 29°C (84.2°F) maximum dew point
Storage 5% to 95% (noncondensing) with 33°C (91°F) maximum dew point
Maximum vibration
Operating 0.26 Grms at 5–350 Hz (all operation orientation)
Storage 1.88 Grms at 10–500 Hz for 15 min (all six sides tested)
Maximum shock
Operating Six consecutively executed shock pulses in the positive and negative x, y, and z axes of 40 G for up to 2.3 ms
Storage Six consecutively executed shock pulses in the positive and negative x, y, and z axes (one pulse on each side of the system) of 71 G for up to 2 ms
Altitude
Operating 3,048 m (10,000 ft)
Storage 12,000 m (39,370 ft)
Operating temperature de-rating
Up to 35 °C (95 °F) Maximum temperature is reduced by 1°C/300 m (33.8°F/984.25 ft) above 950 m (3,117 ft)
35 °C to 40 °C (95 °F to 104 °F) Maximum temperature is reduced by 1°C/175 m (1°F/574.14 ft) above 950 m (3,117 ft).
40 °C to 45 °C (104 °F to 113 °F) Maximum temperature is reduced by 1°C/125 m (1°F/410.1 ft) above 950 m (3,117 ft)

Expanded operating temperature

List of expanded operating temperature requirements.
Expanded operating temperature Specifications
Continuous operation 5°C to 40°C at 5% to 85% RH with 29°C dew point.
NOTE Outside the standard operating temperature (10°C to 35°C), the system can operate continuously in temperatures as low as 5°C and as high as 40°C.

For temperatures between 35°C to 40°C, de-rate maximum allowable temperature by 1°C per 175 m above 950 m (1°F per 319 ft).

≤ 1% of annual operating hours –5°C to 45°C at 5% to 90% RH with 29°C dew point.
NOTE Outside the standard operating temperature (10°C to 35°C), the system can operate down to –5°C or up to 45°C for a maximum of 1% of its annual operating hours.

For temperatures between 40°C and 45°C, de-rate maximum allowable temperature by 1°C per 125 m above 950 m (1°F per 228 ft).

NOTE When operating in the expanded temperature range, system performance may be impacted.
NOTE When operating in the expanded temperature range, ambient temperature warnings may be reported in the System Event Log.

Expanded operating temperature restrictions

  • Do not perform a cold startup below 5°C.
  • The operating temperature specified is for a maximum altitude of 3050 m (10,000 ft).
  • 150 W/8 core, 165 W/12 core and higher wattage processor [Thermal Design Power (TDP)>165 W] are not supported.
  • Redundant power supply unit is required.
  • Non-Dell EMC qualified peripheral cards and/or peripheral cards greater than 25 W are not supported.
  • Tape backup unit is not supported.

Particulate and gaseous contamination specifications

This section defines the limitations that help avoid any equipment damage or failure from particulate and gaseous contamination. If the levels of particulate or gaseous pollution exceed the specified limitations and result in equipment damage or failure, you may need to rectify the environmental conditions. Remediation of environmental conditions is the responsibility of the customer.

Air filtration specification: Data center air filtration as defined by ISO Class 8 per ISO 14644-1 should have a 95% upper confidence limit. Note: This condition applies only to data center environments. Air filtration requirements do not apply to IT equipment designed to be used outside a data center, in environments such as an office or factory floor. Note: Air entering the data center must have the MERV11 or MERV13 filtration. Conductive dust specification: Air must be free of conductive dust, zinc whiskers, or other conductive particles. Note: This condition applies to data center and non-data center environments. Corrosive dust specification: Air must be free of corrosive dust. Residual dust present in the air must have a deliquescent point less than 60% relative humidity. Note: This condition applies to data center and non-data center environments.

Particulate contamination Specifications
Air filtration Data center air filtration as defined by ISO Class 8 per ISO 14644-1 with a 95% upper confidence limit.
NOTE The ISO Class 8 condition applies to data center environments only. This air filtration requirement does not apply to IT equipment designed to be used outside a data center, in environments such as an office or factory floor.
NOTE Air entering the data center must have MERV11 or MERV13 filtration.
Conductive dust Air must be free of conductive dust, zinc whiskers, or other conductive particles.
NOTE This condition applies to data center and non-data center environments.
Corrosive dust
  • Air must be free of corrosive dust.
  • Residual dust present in the air must have a deliquescent point less than 60% relative humidity.
NOTE This condition applies to data center and non-data center environments.
Table 1. Gaseous contamination specifications

The copper coupon corrosion rate is <300 Å/month per Class G1 as defined by ANSI/ISA71.04-2013. The silver coupon corrosion rate is <200 Å/month as defined by ANSI/ISA71.04-2013.

Gaseous contamination Specifications
Copper coupon corrosion rate <300 Å/month per Class G1 as defined by ANSI/ISA71.04-2013.
Silver coupon corrosion rate <200 Å/month as defined by ANSI/ISA71.04-2013.
NOTE Maximum corrosive contaminant levels measured at ≤50% relative humidity.