System dimensions
This section provides details of the dimensions of the NX3340 system.

| System | Xa | Xb | Y | Za (with bezel) | Za (without bezel) | Zb* | Zc |
|---|---|---|---|---|---|---|---|
| 8 x 2.5 inch | 482.0 mm
(18.97 inches) | 434.0 mm
(17.08 inches) | 42.8 mm
(1.68 inches) | 35.84 mm
(1.41 inches) | 22.0 mm
(0.87 inches) | 683.05 mm
(26.89 inches) | 721.91
(28.42 inches) |
Chassis weight
The maximum chassis weight is 21.9 kg (48.28 lbs).
Processor specifications
The NX3340 system supports up to two Intel Xeon Processor Scalable Family processors.
PSU specifications
The NX3340 system supports up to two AC power supply units (PSUs).
| PSU | Class | Heat dissipation (maximum) | Frequency | Voltage |
|---|---|---|---|---|
| 750 W AC | Platinum | 2891 BTU/hr | 50/60 Hz | 100–240 V AC, autoranging |
System battery specifications
The NX3340 system contains a CR 2032 3.0-V lithium coin cell system battery.
Expansion bus specifications
The NX3340 system supports up to four three PCI express (PCIe) 3.0 expansion cards which are installed on the system board using expansion card risers. This system supports 1A and 2A expansion card risers.
Memory specifications
The NX3340 system supports up to twenty four 288-pins RDIMMS with speed of 3200 MT/s or 2666 MT/s with support for memory optimized operation.
| DIMM type | DIMM rank | DIMM capacity | Dual processors | |
|---|---|---|---|---|
| Minimum RAM | Maximum RAM | |||
| RDIMM | Single rank | 8 GB | 32 GB | 192 GB |
Storage controller specifications
- Internal storage controller cards: PowerEdge RAID Controller (PERC) H730P Mini.
- External storage controller cards: PERC H840 and 12 GB SAS HBA.
- External storage:
- Two external enclosures for clustering: 12 Gbp/s MD JBOD - MD1400, MD1420, and SC Series.
- External Tape: LTO external drive, PV114x, TL1000, TL2000, TL4000, ML6000
Drive specifications
The NX3340 system supports up to eight 2.5" SAS, and SATA hard drives and an optional optical drive.
Ports and connectors specifications
The NX3340 system supports USB ports, NIC ports, VGA ports, and a serial connector.
USB ports
The NX3340 supports both USB 2.0 and USB 3.0-compliant ports.
| Location | Type | Quantity |
|---|---|---|
| Front panel | USB 2.0-compliant port | One |
| Front panel | Micro USB 2.0-compliant port for iDRAC Direct | One |
| Back panel | USB 3.0-compliant port | Two |
| Internal | USB 3.0-compliant port | One |
NIC ports
The NX3340 system supports up to four Network Interface Controller (NIC) ports that are integrated on the network daughter card (NDC). The ports are available in the following configurations.
- Four RJ-45 ports that support 10, 100 and 1000 Mbps
- Four RJ-45 ports that support 100 M, 1 G and 10 Gbps
- Four RJ-45 ports, where two ports support maximum of 10 G and the other two ports maximum of 1 G
- Two RJ-45 ports that support up to 1 Gbps and 2 SFP+ ports that support up to 10 Gbps
- Four SFP+ ports that support up to 10 Gbps
- Two SFP28 ports that support up to 25 Gbps
Serial connector
The NX3340 system supports one serial connector on the back panel. This port is a 9-pin connector, Data Terminal Equipment (DTE), 16550-compliant.
VGA ports
The Video Graphic Array (VGA) port enables you to connect the system to a VGA display.
The NX3340 system supports one 15-pin VGA port on the front and back of the system.
Video specifications
The NX3340 system supports integrated VGA controller with 4 MB SPI capacity.
| Resolution | Refresh rate (Hz) | Color depth (bits) |
|---|---|---|
| 640 x 480 | 60, 70 | 8, 16, 32 |
| 800 x 600 | 60, 75, 85 | 8, 16, 32 |
| 1024 x 768 | 60, 75, 85 | 8, 16, 32 |
| 1152 x 864 | 60, 75, 85 | 8, 16, 32 |
| 1280 x 1024 | 60, 75 | 8, 16, 32 |
| 1440 x 900 | 60 | 8, 16, 32 |
| 1920 x 1200 | 60 | 8, 16, 32 |
Environmental specifications
For additional information about environmental measurements for specific system configurations, see dell.com/environmental_datasheets.
| Temperature | |
| Operating (Continuous, for altitude less than 950 m or 3117 ft) | 10°C to 35°C (50°F to 95°F) with no direct sunlight on the equipment.
NOTE Maximum of 205 W, 28 core processor is supported in systems with eight 2.5 inch processor direct attached PCIe SSD drives, and three PCIe slot chassis.
|
| Storage | –40° to 65°C (–40° to 149°F) at a maximum altitude of 12,000 m (39,370 ft) |
| Fresh Air | For information on fresh air, see Expanded Operating Temperature section. |
| Maximum temperature gradient (operating and storage) | 20°C/h (68°F/h) |
| Relative humidity | |
| Operating | 10% to 80% (noncondensing) with 29°C (84.2°F) maximum dew point |
| Storage | 5% to 95% (noncondensing) with 33°C (91°F) maximum dew point |
| Maximum vibration | |
| Operating | 0.26 Grms at 5–350 Hz (all operation orientation) |
| Storage | 1.88 Grms at 10–500 Hz for 15 min (all six sides tested) |
| Maximum shock | |
| Operating | Six consecutively executed shock pulses in the positive and negative x, y, and z axes of 40 G for up to 2.3 ms |
| Storage | Six consecutively executed shock pulses in the positive and negative x, y, and z axes (one pulse on each side of the system) of 71 G for up to 2 ms |
| Altitude | |
| Operating | 3,048 m (10,000 ft) |
| Storage | 12,000 m (39,370 ft) |
| Operating temperature de-rating | |
| Up to 35 °C (95 °F) | Maximum temperature is reduced by 1°C/300 m (33.8°F/984.25 ft) above 950 m (3,117 ft) |
| 35 °C to 40 °C (95 °F to 104 °F) | Maximum temperature is reduced by 1°C/175 m (1°F/574.14 ft) above 950 m (3,117 ft). |
| 40 °C to 45 °C (104 °F to 113 °F) | Maximum temperature is reduced by 1°C/125 m (1°F/410.1 ft) above 950 m (3,117 ft) |
Expanded operating temperature
| Expanded operating temperature | Specifications |
|---|---|
| Continuous operation | 5°C to 40°C at 5% to 85% RH with 29°C dew point.
NOTE Outside the standard operating temperature (10°C to 35°C), the system can operate continuously in temperatures as low as 5°C and as high as 40°C.
For temperatures between 35°C to 40°C, de-rate maximum allowable temperature by 1°C per 175 m above 950 m (1°F per 319 ft). |
| ≤ 1% of annual operating hours | –5°C to 45°C at 5% to 90% RH with 29°C dew point.
NOTE Outside the standard operating temperature (10°C to 35°C), the system can operate down to –5°C or up to 45°C for a maximum of 1% of its annual operating hours.
For temperatures between 40°C and 45°C, de-rate maximum allowable temperature by 1°C per 125 m above 950 m (1°F per 228 ft). |
Expanded operating temperature restrictions
- Do not perform a cold startup below 5°C.
- The operating temperature specified is for a maximum altitude of 3050 m (10,000 ft).
- 150 W/8 core, 165 W/12 core and higher wattage processor [Thermal Design Power (TDP)>165 W] are not supported.
- Redundant power supply unit is required.
- Non-Dell EMC qualified peripheral cards and/or peripheral cards greater than 25 W are not supported.
- PCIe SSD is not supported.
- Tape backup unit is not supported.
Particulate and gaseous contamination specifications
This section defines the limitations that help avoid any equipment damage or failure from particulate and gaseous contamination. If the levels of particulate or gaseous pollution exceed the specified limitations and result in equipment damage or failure, you may need to rectify the environmental conditions. Remediation of environmental conditions is the responsibility of the customer.
| Particulate contamination | Specifications |
|---|---|
| Air filtration | Data center air filtration as defined by ISO Class
8 per ISO 14644-1 with a 95% upper confidence limit. NOTE The ISO Class 8 condition
applies to data center environments only. This air filtration requirement
does not apply to IT equipment designed to be used outside a data
center, in environments such as an office or factory floor. NOTE Air entering the data center must have MERV11 or MERV13 filtration. |
| Conductive dust | Air must be free of conductive dust, zinc whiskers,
or other conductive particles. NOTE This condition applies
to data center and non-data center environments. |
| Corrosive dust |
NOTE This condition
applies to data center and non-data center environments. |
| Gaseous contamination | Specifications |
|---|---|
| Copper coupon corrosion rate | <300 Å/month per Class G1 as defined by ANSI/ISA71.04-2013. |
| Silver coupon corrosion rate | <200 Å/month as defined by ANSI/ISA71.04-2013. |