Dell PowerEdge M830 (For PowerEdge VRTX Enclosure): руководство по обслуживанию

Chassis dimensions

Table 1. Dimensions of the Dell PowerEdge M830 systemSystem height (Y) = 50.35 mm, width (X) = 395.20 mm, and depth (z) = 545.0.
System Dimension in mm
X Y Z
M830 395.20 50.35 545.0

Chassis weight

Maximum chassis weight of the PowerEdge M830 (for PowerEdge VRTX) system is 14.5 kg (31.9 lb).

Processor specification

The PowerEdge M830 system supports up to four Intel Xeon E5-4600 v3 or v4 product family processors.

System battery specification

The PowerEdge M830 system supports CR 2032 3.0-V lithium coin cell system battery.

Memory specifications

The PowerEdge M830 system supports DDR4 registered DIMMs and LR-DDR4 DIMMs at 2400 MT/s, 2133 MT/s, and 1866 MT/s.
Table 1. Memory specificationsYour system supports 48 memory module sockets of 240-pins each. The system supports LRDIMMs of memory capacity 32 GB or 64 GB quad rank, RDIMMs of memory capacity 4 GB single rank, and RDIMMs of memory capacity 8 GB, 16 GB, or 32 GB dual rank. For system with dual processor, the minimum RAM is 4 GB and the maximum RAM is up to 3 TB with four processors.
Memory module socket Memory capacity Minimum RAM Maximum RAM
Forty-eight 240-pin
  • 4 GB single rank (RDIMMs)
  • 8 GB, 16 GB or 32 GB dual rank (RDIMMs)
  • 32 GB or 64 GB quad rank (LRDIMMs)
4 GB with dual processor 3 TB with four processor

RAID controller specifications

The PowerEdge M830 system supports PERC H330, PERC H730, and PERC H730P controllers.

Hard drives

The PowerEdge M830 system supports:
  • Up to four 2.5-inch SAS/SATA/PCIe SSDs or SAS/SATA hard drives
  • Up to twelve 1.8-inch SAS SSDs

Optical drives

The PowerEdge M830 system supports external optional USB DVD optical drive.
NOTE: DVD devices support only data.

Flash drive

The PowerEdge M830 system supports:
  • Internal optional USB
  • Internal optional SD card
  • Optional vFlash card (with integrated iDRAC Enterprise)

USB ports

The PowerEdge M830 system supports:
  • One 4-pin, USB 2.0-compliant and one 9-pin, USB 3.0-compliant on the front panel
  • Internal two 4-pin, USB 2.0-compliant

SD cards

The PowerEdge M830 system supports two internal SD cards dedicated for the hypervisor.
NOTE: One SD card is dedicated for future vFlash support.

PCIe mezzanine card specification

The PowerEdge M830 system supports four PCIe x16 Gen 3 slots mezzanine cards.

Video specifications

The PowerEdge M830 system supports Matrox G200 VGA controller integrated with iDRAC and 2 GB video memory is shared with iDRAC application memory.

Environmental specifications

NOTE: For additional information about environmental measurements for specific system configurations, see Dell.com/environmental_datasheets.
Table 1. Temperature specifications When the system is in continuous operation (for altitude less than 950 m or 3117 ft), the temperature specification ranges from 10°C to 35°C (50°F to 95°F) with no direct sunlight on the equipment. When the system is not in operation, the temperature specification is –40°C to 65°C (–40°F to 149°F). For more information about fresh air, see the Expanded Operating Temperature section. The Maximum temperature gradient for both opertaion and non-opertaional systems is 20°C/h (36°F/h). Information about fresh air specification is described in the Expanded Operating Temperature section.
Temperature Specifications
Storage –40°C to 65°C (–40°F to 149°F)
Continuous operation (for altitude less than 950 m or 3117 ft) 10°C to 35°C (50°F to 95°F) with no direct sunlight on the equipment
Fresh air For information about fresh air, see the Expanded Operating Temperature section.
Maximum temperature gradient (operating and storage) 20°C/h (36°F/h)
Table 2. Relative humidity specificationsFor a non-operational system, the ambient relative humidity ranges from 5% to 95% with 33°C (91°F) maximum dew point. Atmosphere must be non-condensing at all times. For an operational system, the ambient relative humidity ranges from 10% to 80% with 29°C (84.2°F) maximum dew point.
Relative humidity Specifications
Storage 5% to 95% RH with 33°C (91°F) maximum dew point. Atmosphere must be non-condensing at all times.
Operating 10% to 80% RH with 29°C (84.2°F) maximum dew point.
Table 3. Maximum vibration specificationsThe maximum vibration specification of an operational system is 0.26 Grms at 5 Hz to 350 Hz (all operation orientations).The maximum vibration specification of a non-operational system is 1.88 Grms at 10 Hz to 500 Hz for 15 min (all six sides tested).
Maximum vibration Specifications
Operating 0.26 Grms at 5 Hz to 350 Hz (all operation orientations)
Storage 1.88 Grms at 10 Hz to 500 Hz for 15 minutes (all six sides tested)
Table 4. Maximum shock pulse specificationsThe maximum shock specification of an operational system is six consecutively executed shock pulses in the positive and negative x, y, and z axes of 40 G for up to 2.3 ms. The maximum shock specification of a non-operational system is six consecutively executed shock pulses in the positive and negative x, y, and z axes (one pulse on each side of the system) of 71 G for up to 2 ms.
Maximum shock pulse Specifications
Operating Six consecutively executed shock pulses in the positive and negative x, y, and z axes of 40 G for up to 2.3 ms.
Storage Six consecutively executed shock pulses in the positive and negative x, y, and z axes (one pulse on each side of the system) of 71 G for up to 2 ms.
Table 5. Maximum altitude specificationsThe maximum altitude specification for an operational system is 3048 m (10,000 ft). The maximum altitude specification for a non-operational system is 12,000 m (39,370 ft).
Maximum altitude Specifications
Operating 3048 m (10,000 ft)
Storage 12,000 m (39,370 ft)
Table 6. Operating temperature de-rating specificationIf the operating temperature of a system is up to 35 °C (95 °F), the maximum temperature is reduced by 1°C/300 m (1°F/547 ft) above 950 m (3,117 ft). If the operating temperature of a system is 35 °C to 40 °C (95 °F to 104 °F), the maximum temperature is reduced by 1°C/175 m (1°F/319 ft) above 950 m (3,117 ft). If the operating temperature of a system is 40 °C to 45 °C (104 °F to 113 °F), the maximum temperature is reduced by 1°C/125 m (1°F/228 ft) above 950 m (3,117 ft).
Operating temperature de-rating Specifications
Up to 35°C (95°F) Maximum temperature is reduced by 1°C/300 m (1°F/547 ft), above 950 m (3,117 ft).
35 °C to 40 °C (95 °F to 104 °F) Maximum temperature is reduced by 1°C/175 m (1°F/319 ft), above 950 m (3,117 ft).
40 °C to 45 °C (104 °F to 113 °F) Maximum temperature is reduced by 1°C/125 m (1°F/228 ft), above 950 m (3,117 ft).

Particulate and gaseous contamination specifications

The following table defines the limitations that will help avoid any damages to the IT equipment and/or failure from particulates and gaseous contamination. If the levels of particulates or gaseous pollution exceed the specified limitations and result in equipment damage or failure, you may need to rectify the environmental conditions. Re-mediation of environmental conditions is the responsibility of the customer.
Table 1. Particulate contamination specifications Air filtration specification: Data center air filtration as defined by ISO Class 8 per ISO 14644-1 should have a 95% upper confidence limit. Note: This condition applies only to data center environments. Air filtration requirements do not apply to IT equipment designed to be used outside a data center, in environments such as an office or factory floor. Note: Air entering the data center must have MERV11 or MERV13 filtration. Conductive dust specification: Air must be free of conductive dust, zinc whiskers, or other conductive particles. Note: This condition applies to data center and nondata center environments. Corrosive dust specification: Air must be free of corrosive dust. Residual dust present in the air must have a deliquescent point less than 60% relative humidity. Note: This condition applies to data center and nondata center environments.
Particulate contamination Specifications
Air Filtration

Data center air filtration as defined by ISO Class 8 per ISO 14644-1 with a 95% upper confidence limit.

NOTE: This condition applies to data center environments only. Air filtration requirements do not apply to IT equipment designed to be used outside a data center, in environments such as an office or factory floor.
NOTE: Air entering the data center must have MERV11 or MERV13 filtration.

Conductive dust

Air must be free of conductive dust, zinc whiskers, or other conductive particles.

NOTE: This condition applies to data center and nondata center environments.

Corrosive dust

  • Air must be free of corrosive dust.
  • Residual dust present in the air must have a deliquescent point less than 60% relative humidity.
NOTE: This condition applies to data center and nondata center environments.
Table 2. Gaseous contamination specifications The copper coupon corrosion rate is <300 Å/month per Class G1 as defined by ANSI/ISA71.04-1985. The silver coupon corrosion rate is <200 Å/month as defined by AHSRAE TC9.9.
Gaseous contamination Specifications
Copper Coupon Corrosion <300 Å/month per Class G1 as defined by ANSI/ISA71.04-1985.
Silver Coupon Corrosion <200 Å/month as defined by AHSRAE TC9.9.
NOTE: Maximum corrosive contaminant levels measured at ≤50% relative humidity.

Expanded operating temperature

Table 1. Expanded operating temperature specificationsWhen the system is in continuous operation, the expanded operating temperature ranges from 5°C to 40°C at 5% to 85% RH with 29°C dew point. NOTE: Outside the standard operating temperature (10°C to 35°C), the system can operate continuously in temperatures as low as 5°C and as high as 40°C. For temperatures between 35°C and 40°C, de-rate maximum allowable temperature by 1°C per 175 m above 950 m (1°F per 319 ft). When the system is operating at < 1% of annual operating hours, the expanded operating temperature is –5°C to 45°C at 5% to 90% RH with 29°C dew point. NOTE: Outside the standard operating temperature (10°C to 35°C), the system can operate down to –5°C or up to 45°C for a maximum of 1% of its annual operating hours. For temperatures between 40°C and 45°C, de-rate maximum allowable temperature by 1°C per 125 m above 950 m (1°F per 228 ft).
Expanded operating temperature Specifications
Continuous operation 5°C to 40°C at 5% to 85% RH with 29°C dew point.
NOTE: Outside the standard operating temperature (10°C to 35°C), the system can operate continuously in temperatures as low as 5°C and as high as 40°C.

For temperatures between 35°C and 40°C, de-rate maximum allowable temperature by 1°C per 175 m (1°F per 319 ft.) above 950 m (3,1171 ft.).

≤ 1% of annual operating hours –5°C to 45°C at 5% to 90% RH with 29°C dew point.
NOTE: Outside the standard operating temperature (10°C to 35°C), the system can operate down to –5°C or up to 45°C for a maximum of 1% of its annual operating hours.

For temperatures between 40°C and 45°C, de-rate maximum allowable temperature by 1°C per 125 m (1°F per 228 ft.) above 950 m (3.117 ft.).

NOTE: When operating in the expanded temperature range, the performance of the system may be impacted.
NOTE: When operating in the expanded temperature range, ambient temperature warnings may be reported on the LCD panel and in the System Event Log.

Expanded operating temperature restrictions

  1. Do not perform a cold startup below 5 °C
  2. Install only 94 mm wide heat sinks
  3. Do not install more than 40 DIMMs
  4. The following do not support expanded operating temperature range:
    1. PCIe SSD
    2. Express flash
    3. LRDIMMs
    4. 130 W or 120 W all core processors
    5. Non Dell-qualified peripheral cards and/or peripheral cards greater than 25 W