Technical Specifications
| Processor | |
|---|---|
| Processor type | One or two Intel Xeon processor E5-2600 and E5-2600v2 product family |
| Memory | ||
|---|---|---|
| Architecture | 1866 MT/s, 1600 MT/s, 1333 MT/s, 1066 MT/s, or 800 MT/s DDR3 and LV-DDR3 DIMMs | |
| Memory module sockets | Twenty-four 240-pin | |
| Memory module capacities | ||
| RDIMMs | 2 GB (single-rank), 4 GB (single- and dual-rank), 8 GB (dual-rank), 16 GB (dual-rank), and 32 GB (quad-rank) | |
| UDIMMs | 2 GB (single-rank) and 4 GB (dual-rank) | |
| LRDIMMs | 32 GB (quad-rank) | |
| LRDIMMs | 64 GB (octal-rank) | |
| Minimum RAM | 2 GB (single processor configuration) | |
| Maximum RAM | 1.5 TB (with 64 GB LRDIMMs) |
| Drives | |
|---|---|
| Hard drives | Up to two 2.5-inch, hot-swappable SAS/SATA hard drives or two 2.5-inch, hot-swappable SAS/SATA/PCIe SSDs |
| Optical drive | External optional USB DVD NOTE: : DVD devices are data only. |
| Flash drive | Internal optional USB Internal optional SD card Optional vFlash card (with integrated iDRAC7 Enterprise) |
| Connectors | ||
|---|---|---|
| Front | ||
| USB | Two 4-pin, USB 2.0-compliant | |
| Internal | ||
| SD | Two internal SD cards dedicated for the hypervisor One dedicated for future vFlash support |
| Mezzanine Cards | |
|---|---|
| Mezzanine slots | Two mezzanine PCIe x8 Gen 3 slots supporting dual-port Gb Ethernet, 10 Gb Ethernet, FC8 Fibre Channel, or Infiniband mezzanine cards |
| Video | |
|---|---|
| Video type | Matrox G200 integrated with iDRAC |
| Video memory | MB shared with iDRAC application memory |
| Battery | |
|---|---|
| NVRAM backup battery | CR 2032 3.0 V Lithium coin cell |
| Environmental | ||
|---|---|---|
NOTE: : For additional information about environmental measurements for specific system configurations, see dell.com/environmental_datasheets. |
||
| Storage temperature | –40 °C to 65 °C (–40 °F to 149 °F) with a maximum temperature gradation of 20 °C per hour. | |
| Standard operating temperature | Continuous operation: 10 °C to 35 °C at 10% to 80% relative humidity (RH), with 26 °C max dew point. De-rate maximum allowable dry bulb temperature at 1 °C per 300 m above 900 m (1 °F per 550 ft). | |
| Expanded operating temperature (EOT) | ||
NOTE: : When operating in the expanded temperature range, system performance may be impacted. NOTE: : When operating in the expanded temperature range, ambient temperature warnings may be reported on the LCD and in the System Event Log. |
||
| ≤ 10% of annual operating hours | 5 °C to 40 °C at 5% to 85% RH with 26
°C dew point. NOTE: : Outside the standard operating temperature (10 °C to 35 °C), the system can operate down to 5 °C or up to 40 °C for a maximum of 10% of its annual operating hours. For temperatures between 35 °C and 40 °C, de-rate maximum allowable dry bulb temperature by 1 °C per 175 m above 950 m (1 °F per 319 ft). |
|
| ≤ 1% of annual operating hours | –5 °C to 45 °C at 5% to 90% RH with 26
°C dew point. NOTE: : Outside the standard operating temperature (10 °C to 35 °C), the system can operate down to –5 °C or up to 45 °C for a maximum of 1% of its annual operating hours. For temperatures between 40 °C and 45 °C, de-rate maximum allowable dry bulb temperature by 1 °C per 125 m above 950 m (1 °F per 228 ft). |
|
| EOT restrictions |
|