Dell PowerEdge M620 Systems (For PowerEdge VRTX Enclosure): руководство по обслуживанию

Technical Specifications

Processor  
Processor type One or two Intel Xeon processor E5-2600 and E5-2600v2 product family
Memory
Architecture 1866 MT/s, 1600 MT/s, 1333 MT/s, 1066 MT/s, or 800 MT/s DDR3 and LV-DDR3 DIMMs
Memory module sockets Twenty-four 240-pin
Memory module capacities
  RDIMMs 2 GB (single-rank), 4 GB (single- and dual-rank), 8 GB (dual-rank), 16 GB (dual-rank), and 32 GB (quad-rank)
  UDIMMs 2 GB (single-rank) and 4 GB (dual-rank)
  LRDIMMs 32 GB (quad-rank)
  LRDIMMs 64 GB (octal-rank)
Minimum RAM 2 GB (single processor configuration)
Maximum RAM 1.5 TB (with 64 GB LRDIMMs)
Drives  
Hard drives Up to two 2.5-inch, hot-swappable SAS/SATA hard drives or two 2.5-inch, hot-swappable SAS/SATA/PCIe SSDs
Optical drive External optional USB DVD
  • NOTE: DVD devices are data only.
Flash drive

Internal optional USB

Internal optional SD card

Optional vFlash card (with integrated iDRAC7 Enterprise)

Connectors
Front
  USB Two 4-pin, USB 2.0-compliant
Internal  
  SD

Two internal SD cards dedicated for the hypervisor

One dedicated for future vFlash support

PCIe mezzanine cards  
PCIe Mezzanine card slots Two PCIe x8 Gen 2 slots supporting dual-port PCIe mezzanine cards
Video  
Video type Matrox G200 integrated with iDRAC
Video memory MB shared with iDRAC application memory
Battery  
NVRAM backup battery CR 2032 3.0 V Lithium coin cell
Environmental  
  • NOTE: For additional information about environmental measurements for specific system configurations, see dell.com/environmental_datasheets.
  Storage temperature –40 °C to 65 °C (–40 °F to 149 °F) with a maximum temperature gradation of 20 °C per hour.
  Standard operating temperature Continuous operation: 10 °C to 35 °C at 10% to 80% relative humidity (RH), with 26 °C max dew point. De-rate maximum allowable dry bulb temperature at 1 °C per 300 m above 900 m (1 °F per 550 ft).
  Expanded operating temperature (EOT)  
   
  • NOTE: When operating in the expanded temperature range, system performance may be impacted.
  • NOTE: When operating in the expanded temperature range, ambient temperature warnings may be reported on the LCD and in the System Event Log.
  ≤ 10% of annual operating hours 5 °C to 40 °C at 5% to 85% RH with 26 °C dew point.
  • NOTE: Outside the standard operating temperature (10 °C to 35 °C), the system can operate down to 5 °C or up to 40 °C for a maximum of 10% of its annual operating hours.

For temperatures between 35 °C and 40 °C, de-rate maximum allowable dry bulb temperature by 1 °C per 175 m above 950 m (1 °F per 319 ft).

  ≤ 1% of annual operating hours –5 °C to 45 °C at 5% to 90% RH with 26 °C dew point.
  • NOTE: Outside the standard operating temperature (10 °C to 35 °C), the system can operate down to –5 °C or up to 45 °C for a maximum of 1% of its annual operating hours.

For temperatures between 40 °C and 45 °C, de-rate maximum allowable dry bulb temperature by 1 °C per 125 m above 950 m (1 °F per 228 ft).

  EOT restriction
  • Do not perform a cold startup below 5 °C.
  • Maximum 95 W processor is supported.
  • The following do not support the expanded operating temperature range:
    • PCIe SSDs
    • LRDIMMs
    • Dell PowerEdge RAID Controller (PERC) H710/H710P cards (in dual-processor configurations)
  • When populating the server module slots in the PowerEdge VRTX enclosure with only PowerEdge M620 server modules:
    • Install only 97 mm wide heat sink(s).
    • Dual-processor server modules with PERC H310 cards cannot be mixed with single-processor server modules.
    • If you install a server module with two processors and a PERC H310 card in the PowerEdge VRTX enclosure, all server module slots in the enclosure must have PowerEdge M620 server modules with the same configuration (PowerEdge M620 server modules with two processors and a PERC H310 card). However, vacant server module slots in the enclosure can be installed with server module blanks.