Chassis dimensions
| System | Dimension in mm | ||
|---|---|---|---|
| X | Y | Z | |
| FC830 | 427.6 | 40.3 | 538.1 |
Chassis weight
Maximum chassis weight of the PowerEdge FC830 system is 13.0 kg (28.66 lb).
Processor specification
The PowerEdge FC830 system supports up to four Intel Xeon E5-4600 v3 or v4 product family
processors.
System battery specification
The PowerEdge FC830 system supports CR 2032 3.0-V lithium coin cell system battery.
Memory specifications
The PowerEdge FC830 system supports DDR4 registered DIMMs and LV-DDR4 DIMMs at 2400
MT/s, 2133 MT/s, and 1866 MT/s.
| Memory module socket | Memory capacity | Minimum RAM | Maximum RAM |
|---|---|---|---|
| Forty-eight 240-pin |
|
4 GB with dual processor | 1.5 TB with four processor |
RAID controller specifications
The PowerEdge FC830 system supports PERC H330, PERC H730, and PERC H730P controllers.
Hard drives
The PowerEdge FC830 system supports:
- Up to eight 2.5-inch SAS/SATA/PCIe SSDs or SAS/SATA hard drives
- Up to sixteen 1.8-inch SAS SSDs
Optical drives
The PowerEdge FC830 system supports external optional USB DVD optical drive.
NOTE: DVD devices support
only data.
Flash drive
The PowerEdge FC830 system supports:
- Internal optional USB
- Internal optional SD card
- Optional vFlash card (with integrated iDRAC Enterprise)
USB ports
The PowerEdge FC830 system supports:
- One 4-pin, USB 2.0-compliant and one 9-pin, USB 3.0-compliant on the front panel
- Internal two 4-pin, USB 2.0-compliant
SD cards
The PowerEdge FC830 system supports two internal SD cards dedicated for the hypervisor.
NOTE: One SD card is dedicated
for future vFlash support.
PCIe mezzanine card specification
The PowerEdge FC830 system supports two PCIe x16 Gen 3 slots mezzanine cards.
Video specifications
The PowerEdge FC830 system supports Matrox G200 VGA controller integrated with iDRAC
and 2 GB video memory is shared with iDRAC application memory.
Environmental specifications
NOTE: For additional information
about environmental measurements for specific system configurations,
see Dell.com/environmental_datasheets.
| Temperature | Specifications |
|---|---|
| Storage | –40°C to 65°C (–40°F to 149°F) |
| Continuous operation (for altitude less than 950 m or 3117 ft) | 10°C to 35°C (50°F to 95°F) with no direct sunlight on the equipment |
| Fresh air | For information about fresh air, see the Expanded Operating Temperature section. |
| Maximum temperature gradient (operating and storage) | 20°C/h (36°F/h) |
| Relative humidity | Specifications |
|---|---|
| Storage | 5% to 95% RH with 33°C (91°F) maximum dew point. Atmosphere must be non-condensing at all times. |
| Operating | 10% to 80% RH with 29°C (84.2°F) maximum dew point. |
| Maximum vibration | Specifications |
|---|---|
| Operating | 0.26 Grms at 5 Hz to 350 Hz (all operation orientations) |
| Storage | 1.88 Grms at 10 Hz to 500 Hz for 15 minutes (all six sides tested) |
| Maximum shock pulse | Specifications |
|---|---|
| Operating | Six consecutively executed shock pulses in the positive and negative x, y, and z axes of 40 G for up to 2.3 ms. |
| Storage | Six consecutively executed shock pulses in the positive and negative x, y, and z axes (one pulse on each side of the system) of 71 G for up to 2 ms. |
| Maximum altitude | Specifications |
|---|---|
| Operating | 3048 m (10,000 ft) |
| Storage | 12,000 m (39,370 ft) |
| Operating temperature de-rating | Specifications |
|---|---|
| Up to 35°C (95°F) | Maximum temperature is reduced by 1°C/300 m (1°F/547 ft), above 950 m (3,117 ft). |
| 35 °C to 40 °C (95 °F to 104 °F) | Maximum temperature is reduced by 1°C/175 m (1°F/319 ft), above 950 m (3,117 ft). |
| 40 °C to 45 °C (104 °F to 113 °F) | Maximum temperature is reduced by 1°C/125 m (1°F/228 ft), above 950 m (3,117 ft). |
Particulate and gaseous contamination specifications
The following
table defines the limitations that will help avoid any damages to
the IT equipment and/or failure from particulates and gaseous contamination.
If the levels of particulates or gaseous pollution exceed the specified
limitations and result in equipment damage or failure, you may need
to rectify the environmental conditions. Re-mediation of environmental
conditions is the responsibility of the customer.
| Particulate contamination | Specifications |
|---|---|
| Air Filtration | Data center air filtration as defined by ISO Class 8 per ISO 14644-1 with a 95% upper confidence limit. NOTE: This condition
applies to data center environments only. Air filtration requirements
do not apply to IT equipment designed to be used outside a data center,
in environments such as an office or factory floor. NOTE: Air entering the data
center must have MERV11 or MERV13 filtration. |
Conductive dust |
Air must be free of conductive dust, zinc whiskers, or other conductive particles. NOTE: This condition applies
to data center and nondata center environments. |
Corrosive dust |
NOTE: This condition
applies to data center and nondata center environments. |
| Gaseous contamination | Specifications |
|---|---|
| Copper Coupon Corrosion | <300 Å/month per Class G1 as defined by ANSI/ISA71.04-1985. |
| Silver Coupon Corrosion | <200 Å/month as defined by AHSRAE TC9.9. |
NOTE: Maximum
corrosive contaminant levels measured at ≤50% relative humidity.
Expanded operating temperature
| Expanded operating temperature | Specifications |
|---|---|
| Continuous operation | 5°C to 40°C at 5% to 85% RH with 29°C dew point. NOTE: Outside the standard
operating temperature (10°C to 35°C), the system can operate continuously
in temperatures as low as 5°C and as high as 40°C. For temperatures between 35°C and 40°C, de-rate maximum allowable temperature by 1°C per 175 m (1°F per 319 ft.) above 950 m (3,1171 ft.). |
| ≤ 1% of annual operating hours | –5°C to 45°C at 5% to 90% RH with 29°C dew point. NOTE: Outside the standard
operating temperature (10°C to 35°C), the system can operate down
to –5°C or up to 45°C for a maximum of 1% of its annual operating
hours. For temperatures between 40°C and 45°C, de-rate maximum allowable temperature by 1°C per 125 m (1°F per 228 ft.) above 950 m (3.117 ft.). |
NOTE: When
operating in the expanded temperature range, the performance of the
system may be impacted.
NOTE: When operating in the
expanded temperature range, ambient temperature warnings may be reported
on the LCD panel and in the System Event Log.