Chassis dimensions

System | X | Y | Z |
|---|---|---|---|
PowerEdge FC630 | 211.0 mm | 40.3 mm | 535.8 mm |
Chassis weight
System |
Maximum weight |
|---|---|
| PowerEdge FC630 | 6.4 kg (14.11 lb) |
Processor specifications
System battery specifications
Memory specifications
Memory module sockets |
Memory capacity |
Minimum RAM |
Maximum RAM |
Speed |
|---|---|---|---|---|
| PowerEdge FC630 | 64 GB quad rank (LRDIMMs) | 4 GB with single processor |
|
2400 MT/s, 2133 MT/s, or 1866 MT/s, DDR4 DIMMs |
| 32 GB quad rank (LRDIMMs) | 2133 MT/s, or 1866 MT/s,, DDR4 DIMMs |
|||
| 4 GB, 8 GB, 16 GB or 32 GB single rank (RDIMMs) | 2400 MT/s, 2133 MT/s, or 1866 MT/s, DDR4 DIMMs |
|||
| 8 GB, 16 GB and 32 GB dual rank (RDIMMs) | 2400 MT/s, 2133 MT/s, or 1866 MT/s, DDR4 DIMMs |
RAID controllers
PCIe mezzanine card slots
Hard drives
- Up to two 2.5-inch, hot-swappable SAS, SATA hard drives or SAS or SATA or PCIe SSDs
SSDs
- Up to eight 1.8-inch, hot-swappable SATA SSDs
Optical drive
Flash drive
USB ports
- One USB 2.0-compliant and one USB 3.0-compliant port on the front panel
- Internal USB 2.0-compliant port
System |
Front panel |
Internal |
|---|---|---|
| PowerEdge FC630 | One 4-pin, USB 2.0-compliant and one 4-pin, USB 3.0-compliant |
|
Internal Dual SD Module
- Dual card operation — maintains a mirrored configuration by using SD cards in both slots and provides redundancy.
- Single card operation — single card operation is supported, but without redundancy.
Video specifications
Environmental specifications
Temperature |
Specifications |
|---|---|
| Storage | –40°C to 65°C (–40°F to 149°F) |
| Continuous operation (for altitude less than 950 m or 3117 ft) | 10°C to 35°C (50°F to 95°F) with no direct sunlight on the equipment. |
| Fresh air | For information about fresh air, see Expanded Operating Temperature section. |
| Maximum temperature gradient (operating and storage) | 20°C/h (36°F/h) |
Relative humidity |
Specifications |
|---|---|
| Storage | 5% to 95% RH with 33°C (91°F) maximum dew point. Atmosphere must be noncondensing always. |
| Operating | 10% to 80% Relative Humidity with 29°C (84.2°F) maximum dew point. |
Maximum vibration |
Specifications |
|---|---|
| Operating | 0.26 Grms at 5 Hz to 350 Hz (all operation orientations). |
| Storage | 1.88 Grms at 10 Hz to 500 Hz for 15 min (all six sides tested). |
Maximum shock |
Specifications |
|---|---|
| Operating | Six consecutively run shock pulses in the positive and negative x, y, and z axes of 40 G for up to 2.3 ms. |
| Storage | Six consecutively run shock pulses in the positive and negative x, y, and z axes (one pulse on each side of the system) of 71 G for up to 2 ms. |
Maximum altitude |
Specifications |
|---|---|
| Operating | 3048 m (10,000 ft). |
| Storage | 12,000 m (39,370 ft). |
Temperature |
Specifications |
|---|---|
| Up to 35 °C (95 °F) | Maximum temperature is reduced by 1°C/300 m (1°F/547 ft) above 950 m (3,117 ft). |
| 35 °C to 40 °C (95 °F to 104 °F) | Maximum temperature is reduced by 1°C/175 m (1°F/319 ft) above 950 m (3,117 ft). |
| 40 °C to 45 °C (104 °F to 113 °F) | Maximum temperature is reduced by 1°C/125 m (1°F/228 ft) above 950 m (3,117 ft). |
Particulate and gaseous contamination specifications
Particulate contamination |
Specifications |
|---|---|
Air filtration |
Data center air filtration as defined by ISO Class
8 per ISO 14644-1 with a 95% upper confidence limit. NOTE: This condition applies
only to data center environments. Air filtration requirements do not
apply to IT equipment designed to be used outside a data center, in
environments such as an office or factory floor. NOTE: Air entering the data
center must have MERV11 or MERV13 filtration. |
Conductive dust |
Air must be free of conductive dust, zinc whiskers,
or other conductive particles. NOTE: This condition applies
to data center and nondata center environments. |
Corrosive dust |
NOTE: This condition
applies to data center and nondata center environments. |
Gaseous contamination |
Specifications |
|---|---|
Copper coupon corrosion rate |
<300 Å/month per Class G1 as defined by ANSI/ ISA71.04-1985. |
Silver coupon corrosion rate |
<200 Å/month as defined by AHSRAE TC9.9. |
Expanded operating temperature
Expanded operating temperature |
Specifications |
|---|---|
Continuous operation |
5°C to 40°C at 5% to 85% RH with 29°C dew point. NOTE: Outside the standard operating temperature (10°C to 35°C), the system
can operate continuously in temperatures as low as 5°C and as high
as 45°C. For temperatures between 35°C and 40°C, derate maximum allowable temperature by 1°C per 175 m above 950 m (1°F per 319 ft). |
< 1% of annual operating hours |
–5°C to 45°C at 5% to 90% RH with 29°C dew point. NOTE: Outside the standard operating temperature (10°C to 35°C), the system
can operate down to –5°C or up to 45°C for a maximum of 1% of its
annual operating hours. For temperatures between 40°C and 45°C, de-rate maximum allowable temperature by 1°C per 125 m above 950 m (1°F per 228 ft). |
Expanded operating temperature restrictions
- Do not perform a cold startup below 5°C.
- Maximum 105 W processor is supported.
- Non-Dell qualified peripheral cards and/or peripheral cards greater than 25 W are not supported.
- PCIeSSD is not supported.
- When populating
the sled slots in the FX2s enclosure with only PowerEdge FC630 sleds:
- Install 104 mm width heat sink for processors of less than 105 W.
- If you install a sled with two processors in the FX2s enclosure, all sled slots in the enclosure must have PowerEdge FC630 sleds with the same configuration. However, vacant sled slots in the enclosure can be installed with sled blanks.