Dell PowerEdge FC430: руководство по обслуживанию

Chassis dimensions and weight

Figure 1. Chassis dimensions of the PowerEdge FC430 system
This image shows the chassis dimensions of the PowerEdge FC430 system.
Table 1. Dimensions of the PowerEdge FC430 systemThe dimensions of the PowerEdge FC430 system are as follows: X=102.7mm, Y=40.3mm, Z=480.36mm.
SystemXYZ
FC430102.7 mm40.3 mm480.36 mm
Table 2. Chassis weightThe maximum chassis weight of the PowerEdge FC430 system is 3.0 kg (6.61 lb).
SystemChassis weight
FC4303.0 kg (6.61 lb)

Processor specifications

The PowerEdge FC430 system supports up to two Intel Xeon E5-2600 v4 processors.

System battery specification

The PowerEdge FC430 system supports CR 2032 3.0-V lithium coin cell system battery.

Memory specifications

The PowerEdge FC430 system supports DDR4 registered DIMMs (RDIMMs and LRDIMMs).

Table 1. Memory specificationsYour system supports eight memory module sockets of 288-pins each. The system supports RDIMMs of memory capacity 4 GB or 8 GB single rank, and RDIMMs of memory capacity 8 GB, 16 GB, or 32 GB dual rank. The minimum RAM is 4 GB and the maximum RAM is up to 256 GB (RDIMM).

Memory module sockets

Memory capacity

Minimum RAM

Maximum RAM

Eight 288-pin 4 GB, 8 GB, 16 GB, and 32 GB (RDIMMs) 4 GB (RDIMM) 256 GB (RDIMM)
64 GB (LRDIMM)64 GB (LRDIMM)512 GB (LRDIMM)

RAID controller

The PowerEdge FC430 system supports PERC S130 controller.

SSD specification

The PowerEdge FC430 system supports up to two 1.8-inch uSATA SSDs.

USB ports

The PowerEdge FC430 system supports:
  • One 4-pin, USB 3.0 compliant port
  • USB management port or iDRAC Direct port which supports USB 2.0 compliant port

QSFP+ port

The QSFP+ port is used for Infiniband or Ethernet.

PCIe Mezzanine card

The PowerEdge FC430 system supports one PCIe x8 mezzanine slot supporting a single or dual port InfiniBand mezzanine card.

Video specification

The PowerEdge FC430 supports Matrox G200eR2 video controller. The available memory is 16 MB which is shared with the iDRAC application memory.

Environmental specifications

NOTE:For additional information about environmental measurements for specific system configurations, see Dell.com/environmental_datasheets.
Table 1. Temperature specifications When the system is in continuous operation (for altitude less than 950 m or 3117 ft), the temperature specification ranges from 10°C to 35°C (50°F to 95°F) with no direct sunlight on the equipment. When the system is not in operation, the temperature specification is –40°C to 65°C (–40°F to 149°F). The Maximum temperature gradient for both opertaion and non-opertaional systems is 20°C/h (36°F/h). Information about fresh air specification is described in the Expanded Operating Temperature section.
Temperature Specifications
Storage –40°C to 65°C (–40°F to 149°F)
Continuous operation (for altitude less than 950 m or 3117 ft) 10°C to 35°C (50°F to 95°F) with no direct sunlight on the equipment
Maximum temperature gradient (operating and storage) 20°C/h (36°F/h)
Table 2. Relative humidity specificationsFor a non-operational system, the ambient relative humidity ranges from 5% to 95% with 33°C (91°F) maximum dew point. Atmosphere must be non-condensing at all times. For an operational system, the ambient relative humidity ranges from 10% to 80% with 29°C (84.2°F) maximum dew point.
Relative humidity Specifications
Storage 5% to 95% RH with 33°C (91°F) maximum dew point. Atmosphere must be non-condensing at all times.
Operating 10% to 80% RH with 29°C (84.2°F) maximum dew point.
Table 3. Maximum vibration specificationsThe maximum vibration specification of an operational system is 0.26 Grms at 5 Hz to 350 Hz (all operation orientations).The maximum vibration specification of a non-operational system is 1.87 Grms at 10 Hz to 500 Hz for 15 min (all six sides tested).
Maximum vibration Specifications
Operating 0.26 Grms at 5 Hz to 350 Hz (all operation orientations)
Storage 1.87 Grms at 10 Hz to 500 Hz for 15 minutes (all six sides tested)
Table 4. Maximum shock pulse specificationsThe maximum shock specification of an operational system is one shock pulse in the positive z axes of 31 G for 2.6 ms in all operational orientations. The maximum shock specification of a non-operational system is six consecutively executed shock pulses in the positive and negative x, y, and z axes (one pulse on each side of the system) of 71 G for up to 2 ms.
Maximum shock pulse Specifications
Operating One shock pulse in the positive z axes of 31 G for 2.6 ms in all operational orientations.
Storage Six consecutively executed shock pulses in the positive and negative x, y, and z axes (one pulse on each side of the system) of 71 G for up to 2 ms.
Table 5. Maximum altitude specificationsThe maximum altitude specification for an operational system is 3048 m (10,000 ft). The maximum altitude specification for a non-operational system is 12,000 m (39,370 ft).
Maximum altitude Specifications
Operating 3048 m (10,000 ft)
Storage 12,000 m (39,370 ft)
Table 6. Operating temperature de-rating specificationIf the operating temperature of a system is up to 35 °C (95 °F), the maximum temperature is reduced by 1°C/300 m (1°F/547 ft) above 950 m (3,117 ft).
Operating temperature de-rating Specifications
Up to 35°C (95°F) Maximum temperature is reduced by 1°C/300 m (1°F/547 ft) above 950 m (3,117 ft)

Particulate and gaseous contamination specifications

The following table defines the limitations that will help avoid any damages to the IT equipment and/or failure from particulates and gaseous contamination. If the levels of particulates or gaseous pollution exceed the specified limitations and result in equipment damage or failure, you may need to rectify the environmental conditions. Re-mediation of environmental conditions is the responsibility of the customer.
Table 1. Particulate contamination specifications Air filtration specification: Data center air filtration as defined by ISO Class 8 per ISO 14644-1 should have a 95% upper confidence limit. Note: This condition applies only to data center environments. Air filtration requirements do not apply to IT equipment designed to be used outside a data center, in environments such as an office or factory floor. Note: Air entering the data center must have MERV11 or MERV13 filtration. Conductive dust specification: Air must be free of conductive dust, zinc whiskers, or other conductive particles. Note: This condition applies to data center and nondata center environments. Corrosive dust specification: Air must be free of corrosive dust. Residual dust present in the air must have a deliquescent point less than 60% relative humidity. Note: This condition applies to data center and nondata center environments.
Particulate contamination Specifications
Air Filtration

Data center air filtration as defined by ISO Class 8 per ISO 14644-1 with a 95% upper confidence limit.

NOTE:This condition applies to data center environments only. Air filtration requirements do not apply to IT equipment designed to be used outside a data center, in environments such as an office or factory floor.
NOTE:Air entering the data center must have MERV11 or MERV13 filtration.

Conductive dust

Air must be free of conductive dust, zinc whiskers, or other conductive particles.

NOTE:This condition applies to data center and nondata center environments.

Corrosive dust

  • Air must be free of corrosive dust.
  • Residual dust present in the air must have a deliquescent point less than 60% relative humidity.
NOTE:This condition applies to data center and nondata center environments.
Table 2. Gaseous contamination specifications The copper coupon corrosion rate is <300 Å/month per Class G1 as defined by ANSI/ISA71.04-1985. The silver coupon corrosion rate is <200 Å/month as defined by AHSRAE TC9.9.
Gaseous contamination Specifications
Copper Coupon Corrosion <300 Å/month per Class G1 as defined by ANSI/ISA71.04-1985.
Silver Coupon Corrosion <200 Å/month as defined by AHSRAE TC9.9.
NOTE:Maximum corrosive contaminant levels measured at ≤50% relative humidity.

Standard operating temperature

Table 1. Standard operating temperature specificationsThe standard operating temperature for altitude less than 950 metres or 3117 feet ranges from 10°C to 35°C (50°F to 95°F) with no direct sunlight on the equipment.
Standard operating temperature Specifications
Continuous Operation (for altitude less than 950 m or 3117 ft) 10°C to 35°C (50°F to 95°F) with no direct sunlight on the equipment.

Expanded operating temperature restrictions

Table 1. Expanded operating temperature restrictionsThis table describes the expanded operating temperature restrictions.
System Processor configuration (in watts) DIMM Operating temperature
Dual processor system 120 W

RDIMM: 4 GB, 8 GB, 16 GB, and 32 GB

Up to 25ºC ambient
120 W LRDIMM: 64 GB Up to 20ºC ambient
105 W

RDIMM: 4 GB, 8 GB, 16 GB, and 32 GB

Up to 30ºC ambient
105 W LRDIMM: 64 GB Up to 25ºC ambient
90 W

RDIMM: 4 GB, 8 GB, 16 GB, and 32 GB

LRDIMM: 64 GB

Up to 30ºC ambient
<=85 W

RDIMM: 4 GB, 8 GB, 16 GB, and 32 GB

Up to 35ºC ambient
<=85 W

LRDIMM: 64 GB

Up to 30ºC ambient
Single processor system 140 W

RDIMM: 4 GB, 8 GB, 16 GB, and 32 GB

LRDIMM: 64 GB

Up to 30ºC ambient
135 W

RDIMM: 4 GB, 8 GB, 16 GB, and 32 GB

LRDIMM: 64 GB

Up to 30ºC ambient
<=120 W

RDIMM: 4 GB, 8 GB, 16 GB, and 32 GB

LRDIMM: 64 GB

Up to 35ºC ambient