Dell EMC PowerEdge MX840c: технические характеристики и спецификации

Sled dimensions

Figure 1. Dimensions of the PowerEdge MX840c sled
This image shows dimensions of the PowerEdge MX840c sled
Table 1. Dimensions of the PowerEdge MX840c sledThis table gives details of the dimensions of the Dell EMC PowerEdge MX840c sled.
XYZ (handle closed)
250.2 mm (9.85 inches)85.5 mm (3.37 inches)618 mm (24.33 inches)

Chassis weight

Table 1. Chassis weightThe table below shows the maximum weight of the PowerEdge MX840c.
SledMaximum weight (with all drives/SSDs)
8 x 2.5 inch 17 kg (37.47 lb)
6 x 2.5 inch16.8 kg (37.04 lb)

Processor specifications

The PowerEdge MX840c sled supports up to four Intel Xeon Scalable Processors.

Intel Quick Assist Technology

The Intel® Quick Assist Technology (QAT) on the Dell EMC PowerEdge MX840c is supported with chipset integration and is enabled through an optional license. The license files are enabled on the sleds through iDRAC.

For more information about iDRAC, see the Dell Integrated Remote Access Controller User's Guide at www.dell.com/poweredgemanuals

For more information about drivers, documentation, and white papers on the Intel® QAT, see https://01.org/intel-quickassist-technology

Supported operating systems

The PowerEdge MX840c supports the following operating systems:

Red Hat® Enterprise Linux

SUSE® Linux Enterprise Server

Canonical® Ubuntu® LTS

Microsoft Windows Server® with Hyper-V

Virtualization options:

VMware® ESXi

Citrix® XenServer®

NOTE For more information about the specific versions and additions, go to https://www.dell.com/ossupport.

System battery specifications

The PowerEdge MX840c sled supports CR 2032 3.0-V Nickel-Plated lithium coin cell system battery.

Memory specifications

The Dell EMC PowerEdge MX840c system supports the following memory specifications for optimized operation.
Table 1. Memory specificationsThe table below shows the memory specifications for the Dell EMC PowerEdge MX840c system:
DIMM type DIMM rank DIMM capacity Dual processors Quad processors
Minimum RAM Maximum RAM Minimum RAM Maximum RAM
LRDIMM Octa rank 128 GB 256 GB 3 TB 512 GB 6 TB
Quad rank 64 GB 128 GB 1.5 TB 256 GB 3 TB
RDIMM Single rank 8 GB 16 GB 192 GB 32 GB 384 GB
Dual rank 16 GB 32 GB 384 GB 64 GB 768 GB
Dual rank 32 GB 64 GB 768 GB 128 GB 1.5 TB
Dual rank 64 GB 64 GB 768 GB 128 GB 1.5 TB
NVDIMM-N Single rank 16 GB 16 GB 192 GB Supported on the system board only (No NVDIMM-N on PEM)
DCPMM NA 128 GB RDIMM: 384 GB LRDIMM: 1536 GB RDIMM: 384 GB LRDIMM: 3072 GB
DCPMM: 1536 GB DCPMM: 1536 GB DCPMM: 248 GB DCPMM: 3072 GB
NA 256 GB RDIMM: 192 GB LRDIMM: 1536 GB RDIMM: 384 GB LRDIMM: 3072 GB
DCPMM: 2048 GB DCPMM: 3072 GB DCPMM: 4096 GB DCPMM: 6144 GB
NA 512 GB RDIMM: 384 GB LRDIMM: 1536 GB RDIMM: 768 GB LRDIMM: 3072 GB
DCPMM: 4096 GB DCPMM: 6144 GB DCPMM: 8192 GB DCPMM: 12,288 GB
Table 2. Memory module socketsThe table below shows the memory module sockets for the Dell EMC PowerEdge MX840c system:
Memory module sockets Speed
Sixteen 288-pin 2933 MT/s, 2666 MT/s
NOTE 8 GB RDIMMs and NVDIMM-N must not be mixed.
NOTE 64 GB LRDIMMs and 128 GB LRDIMMs must not be mixed.
NOTE Minimum of two processors are required for any configurations that support NVDIMM-N.
NOTE DCPMM can be mixed with RDIMMs and LRDIMMs.
NOTE Mix of Intel DCPMM operating modes (App Direct, Memory Mode) is not supported within socket or across sockets.

Drives

Table 1. Supported drive options for the PowerEdge MX840c sled The table lists out the supported drives for the PowerEdge MX840c sled.
DrivesSpecifications
Eight drivesUp to eight 2.5 inch (SAS, SATA, Nearline SAS, or NVMe) front accessible drives in slots 0 to 7.
Dual processor sledNVMe drives are supported in the slots 4 to 7.
NOTE NVMe is not supported in the slots 0 to 3.
Quad processor sledNVMe drives are supported in the slots 0 to 7.
Six drivesUp to six 2.5 inch (SAS, SATA, Nearline SAS, or NVMe) front accessible drives in slots 0 to 5.
Dual processor sledNVMe drives are supported in the slots 2 to 5.
NOTE NVMe is not supported in the slots 0 to 1.
Quad processor sledNVMe drives are supported in the slots 0 to 5.

USB ports

The PowerEdge MX840c sled supports:
  • One USB 3.0-compliant port on the front of the sled
  • One USB 3.0-compliant port internal port
  • One USB 2.0-compliant management port to iDRAC on the front of the sled
  • One port for IDSDM (USB 3.0 + USB 2.0 for Cypress solution)

Internal Dual SD Module

The PowerEdge MX840c sled supports optional Internal Dual SD module (IDSDM). The IDSDM module is placed in the front of the sled, in a Dell-proprietary slot. The IDSDM module supports two MicroSD cards. The MicroSD cards capacity for IDSDM are 16, 32, 64 GB.

The IDSDM module is available with single MicroSD card in either slot or in redundant mode with two MicroSD cards installed.

NOTE The dip switch is on the IDSDM module for write-protection.
NOTE One IDSDM card slot is dedicated for redundancy.
NOTE It is recommended to use Dell branded MicroSD cards associated with the IDSDM configured systems.

PERC controller cards

The PowerEdge MX840c sled supports PERC9/10 solutions. The PERC provides a base RAID hardware controller without a PCIe slot by using small form factor and high density connector to the system board.

Table 1. Supported PERC controllersThe table describes the supported PERC controllers for the PowerEdge MX840c.
Performance Level Controller and Description
Entry S140 (SATA, NVMe)
SW RAID SATA
Value HBA330 (non-RAID Internal)
Fury IOC
Memory: None
x8 12 Gb/s SAS
x8 PCIe 3.0/2.0
HBA330 MX(non-RAID External)
Memory: None
x8 12 Gb/s SAS
x8 PCIe 3.0
HBA330 Mini-Mezzanine (non-RAID Internal)
Memory: None
x8 12 Gb/s SAS
PCIe 3.0
Value Performance H730P (Internal)
Invader ROC
Memory: 2 GB, NV 72-bit, 866MHz
x8 12 Gb SAS, 6 Gb/s SATA
x8 PCIe 3.0/2.0
H745P (Internal)
Memory: 8 GB
x8 12 Gb SAS
x8 PCIe 3.0/2.0
H730P MX (External)
Memory: 8 GB
x8 12 Gb SAS, 6 Gb/s SATA/SAS, 3 Gb/s SATA
x8 PCIe 3.0
H745P MX (External)
Memory: 8 GB
12 Gb/s SAS, 6 Gb/s SATA/SAS, 3 Gb/s SATA
x8 PCIe 3.0

Mezzanine cards

The PowerEdge MX840c sled supports:

Table 1. Supported mezzanine cardsThe table list the supported mezzanine cards for the PowerEdge MX840c sled.
TypeConnection
Two x16 PCIe Gen3 for mini mezzanine cardsConnected to processor 2 and processor 4
Four x16 PCIe Gen3 for mezzanine cardsMezzanine A is connected to processor 1 and processor 3
Mezzanine B is connected to processor 2 and processor 4

Video specifications

Table 1. Video specificationsThe following table provides the video specifications for the Dell EMC PowerEdge MX740c systems.
Type Description
Video type Matrox G200eW3 graphics controller integrated with iDRAC
Video memory 4 Gb DDR4 shared with iDRAC application memory

Environmental specifications

NOTE For additional information about environmental certifications, please refer to the Product Environmental Datasheet located with the Manuals & Documents on support.dell.com.
Table 1. Temperature specificationsThe table below shows the optimal working temperature specifications.
Temperature Specifications
Storage –40°C to 65°C (–40°F to 149°F)
Continuous operation (for altitude less than 950 m or 3117 ft) 10°C to 35°C (50°F to 95°F) with no direct sunlight on the equipment.
Fresh air For information about fresh air, see the Expanded Operating Temperature section.
Maximum temperature gradient (operating and storage) 20°C/h (68°F/h)
Table 2. Relative humidity specificationsThe table below shows the relative humidity specification during operations and storage.
Relative humidity Specifications
Storage 5% to 95% RH with 33°C (91°F) maximum dew point. Atmosphere must be non-condensing at all times.
Operating 10% to 80% relative humidity with 29°C (84.2°F) maximum dew point.
Table 3. Maximum vibration specificationsThe table below shows the maximum vibration specifications during operations and storage.
Maximum vibration Specifications
Operating 0.26 Grms at 5 Hz to 350 Hz (all operation orientations).
Storage 1.88 Grms at 10 Hz to 500 Hz for 15 min (all six sides tested).
Table 4. Maximum shock specificationsThe table below shows the maximum shock specifications during operations and storage.
Maximum shock Specifications
Operating Six consecutively executed shock pulses in the positive and negative x, y, and z axes of 6 G for up to 11 ms.
Storage Six consecutively executed shock pulses in the positive and negative x, y, and z axes (one pulse on each side of the system) of 71 G for up to 2 ms.
Table 5. Maximum altitude specificationsThe table below shows the maximum altitude specifications during operations and storage.
Maximum altitude Specifications
Operating

30482000 m (10,0006560 ft)

Storage 12,000 m (39,370 ft)
Table 6. Operating temperature derating specificationsThe table below shows the operating temperature derating specifications.
Operating temperature derating Specifications
Up to 35°C (95°F) Maximum temperature is reduced by 1°C/300 m (1°F/547 ft) above 950 m (3,117 ft).
35°C to 40°C (95°F to 104°F) Maximum temperature is reduced by 1°C/175 m (1°F/319 ft) above 950 m (3,117 ft).
40°C to 45°C (104°F to 113°F) Maximum temperature is reduced by 1°C/125 m (1°F/228 ft) above 950 m (3,117 ft).

Particulate and gaseous contamination specifications

The following table defines the limitations that help avoid any equipment damage or failure from particulates and gaseous contamination. If the levels of particulates or gaseous pollution exceed the specified limitations and result in equipment damage or failure, you may need to rectify the environmental conditions. Re-mediation of environmental conditions is the responsibility of the customer.
Table 1. Particulate contamination specificationsAir filtration specification: Data center air filtration as defined by ISO Class 8 per ISO 14644-1 shpuld have a 95% upper confidence limit. Note: This condition applies only to data center environments. Air filtration requirements do not apply to IT equipment designed to be used outside a data center, in environments such as an office or factory floor. Note: Air entering the data center must have MERV11 or MERV13 filtration. Conductive dust specification: Air must be free of conductive dust, zinc whiskers, or other conductive particles. Note: This condition applies to data center and non-data center environments. Corrosive dust specification: Air must be free of corrosive dust. Residual dust present in the air must have a deliquescent point less than 60% relative humidity. Note: This condition applies to data center and non-data center environments.
Particulate contamination Specifications
Air filtration Data center air filtration as defined by ISO Class 8 per ISO 14644-1 with a 95% upper confidence limit.
NOTE This condition applies to data center environments only. Air filtration requirements do not apply to IT equipment designed to be used outside a data center, in environments such as an office or factory floor.
NOTE Air entering the data center must have MERV11 or MERV13 filtration.
Conductive dust Air must be free of conductive dust, zinc whiskers, or other conductive particles.
NOTE This condition applies to data center and non-data center environments.
Corrosive dust
  • Air must be free of corrosive dust.
  • Residual dust present in the air must have a deliquescent point less than 60% relative humidity.
NOTE This condition applies to data center and non-data center environments.
Table 2. Gaseous contamination specificationsThe copper coupon corrosion rate is <300 Å/month per Class G1 as defined by ANSI/ISA71.04-1985. The silver coupon corrosion rate is <200 Å/month as defined by AHSRAE TC9.9.
Gaseous contamination Specifications
Copper coupon corrosion rate <300 Å/month per Class G1 as defined by ANSI/ISA71.04-1985.
Silver coupon corrosion rate <200 Å/month as defined by AHSRAE TC9.9.
NOTE Maximum corrosive contaminant levels measured at ≤50% relative humidity.

Standard operating temperature

Table 1. Standard operating temperature specificationsThe standard operating temperature for altitude less than 950 metres or 3117 feet ranges from 10°C to 35°C (50°F to 95°F) with no direct sunlight on the equipment.
Standard operating temperature Specifications
Continuous operation (for altitude less than 950 m or 3117 ft) 10°C to 35°C (50°F to 95°F) with no direct sunlight on the equipment.
Humidity percentage range10% to 80% relative humidity with 29°C (84.2°F) maximum dew point.

Expanded operating temperature

Table 1. Expanded operating temperature specificationsWhen the system is in continuous operation, the expanded operating temperature ranges from 10°C to 40°C at 5% to 85% RH with 29°C dew point. NOTE: Outside the standard operating temperature (10°C to 40°C), the system can operate continuously in temperatures as low as 5°C and as high as 40°C. For temperatures between 35°C and 40°C, de-rate maximum allowable temperature by 1°C per 175 m above 950 m (1°F per 319 ft). When the system is operating at < 1% of annual operating hours, the expanded operating temperature is –5°C to 45°C at 5% to 90% RH with 29°C dew point.

NOTE: Outside the standard operating temperature (10°C to 40°C), the system can operate down to –5°C or up to 45°C for a maximum of 1% of its annual operating hours. For temperatures between 40°C and 45°C, de-rate maximum allowable temperature by 1°C per 125 m above 950 m (1°F per 228 ft).

Expanded operating temperature Specifications
Continuous operation 5°C to 40°C at 5% to 85% RH with 29°C dew point.
NOTE Outside the standard operating temperature (10°C to 40°C), the system can operate continuously in temperatures as low as 5°C and as high as 40°C.

For temperatures between 35°C and 40°C, de-rate maximum allowable temperature by 1°C per 175 m above 950 m (1°F per 319 ft).

≤ 1% of annual operating hours –5°C to 45°C at 5% to 90% RH with 29°C dew point.
NOTE Outside the standard operating temperature (10°C to 40°C), the system can operate down to –5°C or up to 45°C for a maximum of 1% of its annual operating hours.

For temperatures between 40°C and 45°C, de-rate maximum allowable temperature by 1°C per 125 m above 950 m (1°F per 228 ft).

NOTE When operating in the expanded temperature range, system performance may be impacted.
NOTE When operating in the expanded temperature range, ambient temperature warnings may be reported on the bezel's LCD panel and in the System Event Log.

Expanded operating temperature restrictions

  • Do not perform a cold startup below 5°C.
  • The operating temperature specified is for a maximum altitude of 3050 m (10,000 ft).
  • Low core count processors [Gold 6240Y, 6146, 6144] and higher wattage processors [Thermal Design Power (TDP)>=165 W] are not supported.
  • Non-Dell qualified peripheral cards and/or peripheral cards greater than 30 W are not supported.
  • PCIe SSD is not supported.
  • NVDIMM is not supported.
  • DCPMM is not supported.

Thermal

PowerEdge servers have an extensive collection of sensors that automatically track thermal activity, which helps regulate temperature thereby reducing server noise and power consumption. The sensors in the MX840c interact with the chassis management services module which regulates fan speed. All fans which cool the MX840c are contained in the MX7000 chassis.

Thermal management of PowerEdge MX840c delivers high performance for the right amount of cooling to components at the lowest fan speeds across a wide range of ambient temperatures from 10°C to 35°C (50°F to 95°F) and to extended ambient temperature ranges (see Environmental Specifications). The benefits to you are lower fan power consumption (lower server system power and data center power consumption) and greater acoustical versatility.

Table 1. Thermal restrictions matrixThe following table describes the thermal restriction matrix for the PowerEdge MX840c.
Ambient support25°C 30°C 35°C 40°C-45°C Expanded operating temperature
ProcessorNo restrictionNo restrictionNo restrictionNo support for 165 W processors and above.

No support for Gold 6144(150W8c) 6146(165W12c) 6240Y(150W8c)

DIMMNo restrictionNo restrictionNo restrictionNo support for NVDIMM
DriveNo restrictionNo restrictionNo restrictionNo support for NVMe drive
CardNo restrictionNo restrictionNo restrictionNo support for card power above 30 W