Dell EMC PowerEdge MX740c: технические характеристики и спецификации

System dimensions

Figure 1. System dimensions
This image shows System dimensions
Table 1. System dimensions of thePowerEdge MX740c systemSystem dimensions
SystemXYZ (handle closed).
Dell EMCPowerEdge MX740c250.2 mm (9.85 inches)42.15 mm (1.65 inches)620.35 mm (24.42 inches)

System weight

Table 1. System weightSystem weight
SystemMaximum weight
Dell EMC PowerEdge MX740c 9.5 kg (20.94 lb)

Processor specifications

The Dell EMC PowerEdge MX740c system supports up to two Intel Xeon Scalable processors, up to 28 cores per processor.

Processor wattage and heat sink dimensions

Table 1. Processor wattage and heat sink dimensionsThis table shows the processor wattage and heat sink dimensions.
Processor configurationProcessor typeHeat sink widthNumber of maximum DIMMS per processorNumber of DIMMS, RAS)
AllUp to 205 W90 mm1212

Intel Quick Assist Technology

The Intel® Quick Assist Technology (QAT) on the Dell EMC PowerEdge MX740c is supported with chipset integration and is enabled through an optional license. The license files are enabled on the sleds through iDRAC.

For more information about iDRAC, see the Dell Integrated Remote Access Controller User's Guide at www.dell.com/poweredgemanuals

For more information about drivers, documentation, and white papers on the Intel® QAT, see https://01.org/intel-quickassist-technology.

Supported operating systems

The Dell EMC PowerEdge MX740c sled supports the following operating systems:

  • Citrix XenServer
  • Microsoft Windows Server with Hyper-V
  • Red Hat Enterprise Linux
  • SuSE Linux Enterprise Server
  • Ubuntu
  • VMWare ESXi
For more information about the specific versions and editions, go to https://www.dell.com/ossupport.

System battery specifications

The Dell EMC PowerEdge MX740c system supports CR 2032 3.0-V Nickel-Plated lithium coin cell system battery.

Memory specifications

Table 1. Memory specificationsThe table below shows the memory specifications for the MX740c system:
DIMM type DIMM rank DIMM capacity Single processor Dual processors
Minimum RAM Maximum RAM Minimum RAM Maximum RAM
LRDIMM Octal rank 128 GB 128 GB 1536 GB 256 GB 3072 GB
Quad rank 64 GB 64 GB 768 GB 128 GB 1536 GB
RDIMM Single rank 8 GB 8 GB 96 GB 16 GB 192 GB
Dual rank 16 GB 16 GB 192 GB 32 GB 384 GB
32 GB 32 GB 384 GB 64 GB 768 GB
64 GB 64 GB 768 GB 128 GB 1536 GB
NVDIMM-N Single rank 16 GB Not supported with single processor Not supported with single processor RDIMM: 192 GB RDIMM: 384 GB
NVDIMM-N: 16 GB NVDIMM-N: 192 GB
DCPMM NA 128 GB RDIMM: 64 GB RDIMM: 384 GB RDIMM: 128 GB LRDIMM: 1536 GB
DCPMM: 128 GB DCPMM: 128 GB DCPMM: 1536 GB DCPMM: 1536 GB
NA 256 GB NA NA RDIMM: 192 GB LRDIMM: 1536 GB
NA NA DCPMM: 2048 GB DCPMM: 3072 GB
NA 512 GB NA NA RDIMM: 384 GB RDIMM: 1536 GB
NA NA DCPMM: 4096 GB DCPMM: 6144 GB
NOTE 8 GB RDIMMs and NVDIMM-N must not be mixed.
NOTE 64 GB LRDIMMs and 128 GB LRDIMMs must not be mixed.
NOTE Minimum of two processors are required for any configurations that support NVDIMM-N.
NOTE DCPMM can be mixed with RDIMMs and LRDIMMs.
NOTE Mix of Intel DCPMM operating modes (App Direct, Memory Mode) is not supported within socket or across sockets.

Hard drives

The Dell EMC PowerEdge MX740c system supports upto six 2.5-inch, hot-swappable SAS/SATA HDDs, SSDs, or PCIe NVMe drives.

The drives are supplied in a hot-swappable drive carriers and these drives connect to the system board or RAID controller through the backplane.

NOTE A dual-processor configuration is required to support NVMe drives.

Mezzanine and Mini Mezzanine slots specifications

The Dell EMC PowerEdge MX740c supports:
  • One x16 PCIe Gen3 for Mini Mezzanine cards - connected to Processor 2.
  • Two x16 PCIe Gen3 for Mezzanine cards - Mezzanine A1 is connected to Processor 1, Mezzanine B1 is connected to Processor 2.

Storage controller specifications

The Dell EMC PowerEdge MX740c system supports PowerEdge RAID Controller (PERC) HBA330 MX, HBA330, H730P MX, H745P MX, H730P, H745P, S140 (SATA and NVMe drives),HBA330 MMZ(mini Mezzanine card), Fiber Fiber channel HBA (in Mini mezzanine Fab C slot), and Boot Optimized Server Storage (BOSS M.2).

USB ports

The Dell EMC PowerEdge MX740c system supports:
  • One USB 3.0-compliant port on the front of the system
  • One micro USB/iDRAC Direct USB 2.0-compliant port on the front of the system
  • One USB 3.0-compliant internal port
NOTE The micro USB 2.0-compliant port on the front of the system can only be used as an iDRAC Direct management port.

Internal Dual SD Module

The Dell EMC PowerEdge MX740c system supports optional Internal Dual SD module (IDSDM) module. In 14th generation of PowerEdge servers, IDSDM module supports two micro SD cards. Micro SD cards capacities for IDSDM are 16, 32, 64 GB.
NOTE There are two dip switches on the IDSDM module for write-protection.
NOTE One IDSDM card slot is dedicated for redundancy.
NOTE It is recommended to use Dell branded MicroSD cards associated with the IDSDM configured systems.

Micro SD vFlash connector

The Dell EMC PowerEdge MX740c system supports one dedicated micro SD card on iDRAC module for future vFlash support. It is recommended to use Dell branded MicroSD card associated with the iDRAC module.

Video specifications

Table 1. Video specificationsThe following table provides the video specifications for the Dell EMC PowerEdge MX740c systems.
Type Description
Video type Matrox G200eW3 graphics controller integrated with iDRAC
Video memory 4 Gb DDR4 shared with iDRAC application memory

Environmental specifications

NOTE For additional information about environmental certifications, please refer to the Product Environmental Datasheet located with the Manuals & Documents on www.dell.com/poweredgemanuals
Table 1. Temperature specificationsThe below table lists Temperature specifications.
Temperature Specifications
Storage –40°C to 65°C (–40°F to 149°F)
Continuous operation (for altitude less than 950 m or 3117 ft) 10°C to 35°C (50°F to 95°F) with no direct sunlight on the equipment.
Maximum temperature gradient (operating and storage) 20°C/h (68°F/h)
Table 2. Relative humidity specificationsFor a nonoperational system, the ambient relative humidity ranges from 5% to 95% with 33°C (91°F) maximum dew point. Atmosphere must be noncondensing always. For an operational system, the ambient relative humidity ranges from 10% to 80% with 29°C (84.2°F) maximum dew point.
Relative humidity Specifications
Storage 5% to 95% RH with 33°C (91°F) maximum dew point. Atmosphere must be noncondensing always.
Operating 10% to 80% relative humidity with 29°C (84.2°F) maximum dew point.
Table 3. Maximum vibration specificationsThe maximum vibration specification of an operational system is 0.26 Grms at 5 Hz to 350 Hz (all operation orientations).The maximum vibration specification of a nonoperational system is 1.87 Grms at 10 Hz to 500 Hz for 15 min (all six sides tested).
Maximum vibration Specifications
Operating 0.26 Grms at 5 Hz to 350 Hz (all operation orientations).
Storage 1.87 Grms at 10 Hz to 500 Hz for 15 min (all six sides tested).
Table 4. Maximum shock specificationsThe maximum shock specification of an operational system is six consecutively executed shock pulses in the positive and negative x, y, and z axes of 6 G for up to 11 ms. The maximum shock specification of a non-operational system is six consecutively executed shock pulses in the positive and negative x, y, and z axes (one pulse on each side of the system) of 71 G for up to 2 ms.
Maximum shock Specifications
Operating Six consecutively executed shock pulses in the positive and negative x, y, and z axes of 6 G for up to 11 ms.
Storage Six consecutively executed shock pulses in the positive and negative x, y, and z axes (one pulse on each side of the system) of 71 G for up to 2 ms.
Table 5. Maximum altitude specificationsThe maximum altitude specification for an operational system is 3048 m (10,000 ft). The maximum altitude specification for a nonoperational system is 12,000 m (39,370 ft).
Maximum altitude Specifications
Operating

3048 m (10,000 ft)

Storage 12,000 m (39,370 ft)
Table 6. Operating temperature derating specificationsThe below table lists Operating temperature derating specifications.
Operating temperature derating Specifications
Up to 35°C (95°F) Maximum temperature is reduced by 1°C/300 m (1°F/547 ft) above 950 m (3,117 ft).
35°C to 40°C (95°F to 104°F) Maximum temperature is reduced by 1°C/175 m (1°F/319 ft) above 950 m (3,117 ft).
40°C to 45°C (104°F to 113°F) Maximum temperature is reduced by 1°C/125 m (1°F/228 ft) above 950 m (3,117 ft).

Particulate and gaseous contamination specifications

The following table defines the limitations that help avoid any equipment damage or failure from particulates and gaseous contamination . If the levels of particulates or gaseous pollution exceed the specified limitations and result in equipment damage or failure, you may must rectify the environmental conditions. Remediation of environmental conditions is the responsibility of the customer.
Table 1. Particulate contamination specificationsThe below table lists Particulate contamination specifications.
Particulate contamination Specifications
Air filtration Data center air filtration as defined by ISO Class 8 per ISO 14644-1 with a 95% upper confidence limit.
NOTE This condition applies to data center environments only. Air filtration requirements do not apply to IT equipment designed to be used outside a data center, in environments such as an office or factory floor.
NOTE Air entering the data center must have MERV11 or MERV13 filtration.
Conductive dust Air must be free of conductive dust, zinc whiskers, or other conductive particles.
NOTE This condition applies to data center and nondata center environments.
Corrosive dust
  • Air must be free of corrosive dust.
  • Residual dust present in the air must have a deliquescent point less than 60% relative humidity.
NOTE This condition applies to data center and nondata center environments.
Table 2. Gaseous contamination specificationsThe copper coupon corrosion rate is <300 Å/month per Class G1 as defined by ANSI/ISA71.04-1985. The silver coupon corrosion rate is <200 Å/month as defined by AHSRAE TC9.9.
Gaseous contamination Specifications
Copper coupon corrosion rate <300 Å/month per Class G1 as defined by ANSI/ISA71.04-1985.
Silver coupon corrosion rate <200 Å/month as defined by AHSRAE TC9.9.
NOTE Maximum corrosive contaminant levels measured at ≤50% relative humidity.

Standard operating temperature

Table 1. Standard operating temperature specificationsThe below table lists Standard operating temperature specifications.
Standard operating temperature Specifications
Continuous operation (for altitude less than 950 m or 3117 ft) 10°C to 35°C (50°F to 95°F) with no direct sunlight on the equipment.
Humidity percentage range 10% to 80% Relative Humidity with 29°C (84.2°F) maximum dew point.

Expanded operating temperature

Table 1. Expanded operating temperature specificationsThe below table lists Expanded operating temperature specifications.
Expanded operating temperature Specifications
Continuous Operation 5°C–40°C at 5% to 85% RH with 29°C dew point
NOTE Outside the standard operating temperature (10°C–35°C), the system can operate continuously in temperatures as low as 5°C and as high as 40°C.

For temperatures 35°C–40°C, derate maximum allowable dry bulb temperature by 1°C per 175 m above 950 m (1°F per 319 ft).

Less than or equal to 1% of annual operating hours –5°C–45°C at 5% to 90% RH with 29°C dew point
NOTE Outside the standard operating temperature (10°C–35°C), the system can operate down to –5°C or up to 45°C for a maximum of 1% of its annual operating hours.

For temperatures 40°C–45°C, derate maximum allowable temperature by 1°C per 125 m above 950 m (1°F per 228 ft).

NOTE When operating in the expanded temperature range, system performance may be impacted.
NOTE When operating in the expanded temperature range, ambient temperature warnings maybe reported on the LCD panel and in the System event log.

Expanded operating temperature restrictions

  1. Do not perform a cold startup below 5°C.
  2. The operating temperature that is specified is for a maximum altitude of 3050 m(10,000 ft).
  3. Low core count processors [Gold 6146,6144,6134,6128,5222,5217,5122] and higher wattage processors [Thermal Design Power (TDP)>140 W] are not supported.
  4. Non-Dell qualified peripheral cards or peripheral cards greater than 30 W are not supported.
  5. PCIe SSD is not supported.
  6. NVDIMM are not supported.
  7. DCPMMs are not supported.

Thermal

PowerEdge servers have an extensive collection of sensors that automatically track thermal activity, which helps regulate temperature thereby reducing server noise and power consumption. The sensors in the MX740c interact with the chassis management services module which regulates fan speed. All fans which cool the MX740c are contained in the MX7000 chassis.

Thermal management of PowerEdge MX740c delivers high performance for the right amount of cooling to components at the lowest fan speeds across a wide range of ambient temperatures from 10°C to 35°C (50°F to 95°F) and to extended ambient temperature ranges (see Environmental Specifications section). The benefits to you are lower fan power consumption (lower server system power and data center power consumption) and greater acoustical versatility.

For detailed information about thermal please consult the MX7000 Technical Guide.

Table 1. Thermal restriction matrix

This table describes the thermal restriction for Dell EMC PowerEdge MX740c system:

Ambient Support 25 ° C 30 ° C 35 ° C 40 ° C ~ 45 ° C Expanded Operating Temperature
CPU No restriction No restriction No restriction

(The recommended operating temperature for processors with Thermal Design Power (TDP) > 165W is under 32°C)

Not Supported for the below SKUs:

CLX R 205W, x6 BP (6258R, 6248R, 6246R, 6242R) on MX740c

Does not support CPU with TDP> 140W

No Support: Gold 6132(140W 14C), Gold 6134(130W 8C), Gold 6128(115W 6C), Gold 5122(105W 4C)processors

6234(130W 8C), 5217(115W 8C),5222(105W 4C) processors

DIMM No restriction No restriction No restriction Does not support NVDIMM
Drives No restriction No restriction No restriction Does not support NVMe (PCIe SSDs)
PCIe card No restriction No restriction No restriction No support for card power above 30W
CLX Refresh 205W CPU (6242R, 6246R, 6248R, 6258R) configuration No restriction No restriction (The recommended operating temperature for processors with Thermal designs power 205W is <=25 ° C) Not supported Not supported