System dimensions

| System | X | Y | Z (handle closed) |
|---|---|---|---|
| Dell EMCPowerEdgeM640 | 197.92 mm (7.79 inches) | 50.35 mm (1.98 inches) | 544.32 mm (21.43 inches) |
System weight
| System | Maximum weight |
|---|---|
| Dell EMC PowerEdge M640 | 6.4 kg (14.11 lb) |
Processor specifications
Supported operating systems
- RedHat Enterprise Linux Server
- SUSE Linux Enterprise Server
- Microsoft Windows Server
- VMware
- Citrix Xen Server
- Canonical Ubuntu LTS
System battery specifications
Memory specifications
| Memory module sockets | DIMM type | DIMM rank | DIMM capacity | Single processor | Dual processors | ||
|---|---|---|---|---|---|---|---|
| Minimum RAM | Maximum RAM | Minimum RAM | Maximum RAM | ||||
| Sixteen 288-pins | LRDIMM | Octa rank | 128 GB | 128 GB | 1024 GB | 256 GB | 2048 GB |
| Quad rank | 64 GB | 64 GB | 512 GB | 128 GB | 1024 GB | ||
| RDIMM | Single rank | 8 GB | 8 GB | 64 GB | 16 GB | 128 GB | |
| Dual rank | 16 GB | 16 GB | 128 GB | 32 GB | 256 GB | ||
| Dual rank | 32 GB | 32 GB | 256 GB | 64 GB | 512 GB | ||
| Dual rank | 64 GB | 64 GB | 512 GB | 128 GB | 1024 GB | ||
Mezzanine card specifications
Storage controller specifications
The PowerEdge M640p system supports :
- Internal controllers:Software RAID S140, PowerEdge RAID controller(PERC)9 H330, H730P
- Boot Optimized Storage Subsystem(BOSS): HWRAID 2 x M.2 SSDs 120GB, 240 GB
- Internal Dual SD Module optional
Hard drives
USB ports
- One USB 3.0-compliant port on the front of the system
- One micro USB/iDRAC direct USB 2.0-compliant port on the front of the system
- One USB 3.0-compliant internal port
Internal Dual SD Module
- Dual card operation — maintains a mirrored configuration by using micro SD cards in both slots and provides redundancy.
- Single card operation — single card operation is supported, but without redundancy.
Micro SD vFlash connector
Video specifications
| Features | Specifications |
|---|---|
| Video type | Matrox G200eW3 graphics controller integrated with iDRAC |
| Video memory | 4 GB DDR4 shared with iDRAC application memory |
Environmental specifications
| Temperature | Specifications |
|---|---|
| Storage | –40°C to 65°C (–40°F to 149°F) |
| Continuous operation (for altitude less than 950 m or 3117 ft) | 10°C to 35°C (50°F to 95°F) with no direct sunlight on the equipment. |
| Maximum temperature gradient (operating and storage) | 20°C/h (68°F/h) |
| Relative humidity | Specifications |
|---|---|
| Storage | 5% to 95% RH with 33°C (91°F) maximum dew point. Atmosphere must be non-condensing at all times. |
| Operating | 10% to 80% relative humidity with 26°C (78.8°F) maximum dew point. |
| Maximum vibration | Specifications |
|---|---|
| Operating | 0.26 Grms at 5 Hz to 350 Hz (all operation orientations). |
| Storage | 1.87 Grms at 10 Hz to 500 Hz for 15 min (all six sides tested). |
| Maximum shock | Specifications |
|---|---|
| Operating | Six consecutively executed shock pulses in the positive and negative x, y, and z axes of 6 G for up to 11 ms. |
| Storage | Six consecutively executed shock pulses in the positive and negative x, y, and z axes (one pulse on each side of the system) of 71 G for up to 2 ms. |
| Maximum altitude | Specifications |
|---|---|
| Operating | 3048 m (10,000 ft) |
| Storage | 12,000 m (39,370 ft) |
| Operating temperature de-rating | Specifications |
|---|---|
| Up to 35°C (95°F) | Maximum temperature is reduced by 1°C/300 m (1°F/547 ft) above 950 m (3,117 ft). |
| 35°C to 40°C (95°F to 104°F) | Maximum temperature is reduced by 1°C/175 m (1°F/319 ft) above 950 m (3,117 ft). |
| 40°C to 45°C (104°F to 113°F) | Maximum temperature is reduced by 1°C/125 m (1°F/228 ft) above 950 m (3,117 ft). |
Particulate and gaseous contamination specifications
| Particulate contamination | Specifications |
|---|---|
| Air filtration | Data center air filtration as defined by ISO Class
8 per ISO 14644-1 with a 95% upper confidence limit. NOTE This condition applies
to data center environments only. Air filtration requirements do not
apply to IT equipment designed to be used outside a data center, in
environments such as an office or factory floor. NOTE Air entering the data
center must have MERV11 or MERV13 filtration. |
| Conductive dust | Air must be free of conductive dust, zinc whiskers,
or other conductive particles. NOTE This condition applies
to data center and non-data center environments. |
| Corrosive dust |
NOTE This condition
applies to data center and non-data center environments. |
| Gaseous contamination | Specifications |
|---|---|
| Copper coupon corrosion rate | <300 Å/month per Class G1 as defined by ANSI/ISA71.04-1985. |
| Silver coupon corrosion rate | <200 Å/month as defined by AHSRAE TC9.9. |
Standard operating temperature
| Standard operating temperature | Specifications |
|---|---|
| Continuous operation (for altitude less than 950 m or 3117 ft) | 10°C to 35°C (50°F to 95°F) with no direct sunlight on the equipment. |
| Humidity percentage range | 10% to 80% Relative Humidity with 26°C (78.8°F) maximum dew point. |
Expanded operating temperature
| Expanded operating temperature | Specifications |
|---|---|
| Continuous operation | 5°C to 40°C at 5% to 85% RH with 29°C dew point. NOTE Outside the standard
operating temperature (10°C to 35°C), the system can operate continuously
in temperatures as low as 5°C and as high as 40°C. For temperatures between 35°C and 40°C, de-rate maximum allowable dry bulb temperature by 1°C per 175 m above 950 m (1°F per 319 ft). |
| Less than or equal to 1% of annual operating hours | –5°C to 45°C at 5% to 90% RH with 29°C dew point. NOTE Outside the standard
operating temperature (10°C to 35°C), the system can operate down
to –5°C or up to 45°C for a maximum of 1% of its annual operating
hours. For temperatures between 40°C and 45°C, de-rate maximum allowable temperature by 1°C per 125 m above 950 m (1°F per 228 ft). |
Expanded operating temperature restrictions
The expanded operating temperature restrictions for the PowerEdge M640 system are listed here:
- Do not perform a cold startup below 5°C.
- The operating temperature specified is for a maximum altitude of 3048 metres (10,000 feet ).
- NVME drives are not supported.
- AEP DIMMs are not supported.
- 105 W/4 C, 115 W/6 C, 130 W/8 C, 140 W/14 C or higher wattage processor (TDP > 140 W) are not supported.
- NEBS SKU processors higher than 85 W are not supported.
- Peripheral cards and /or peripheral cards greater than 25 W, that are not verified by Dell, are not supported.
Thermal Restriction matrix
| Thermal Design Power (TDP) for the processor | Core count | Processors | Ambient restriction | ||
|---|---|---|---|---|---|
| M1000e | VRTX | FX2 | |||
| 205W | 28/24 | 8180; 8168 | Not supported | C25, DIMM limit 2* | C25, Special limit* |
| 205W | 28/26/24 | 8280; 8270;8268;8280M;8280L | Not supported | C25, DIMM limit 2* | C25, Special limit* |
| 205W | 24/16/20 | 6248R;6246R;6242R | Not supported* | Not supported* | Not supported* |
| 200W | 18 | 6154;6254 | Not supported | C25, DIMM limit 2* | C25, Special limit* |
| 165W | 28/26/18 | 8176; 8170; 6150 | C30, DIMM limit 1* | C35, DIMM limit 1* | C30, DIMM limit 1* |
| 165W | 12 | 6246 | C25, Special limit* | C30, DIMM limit 1* | C25, Special limit* |
| 165W | 28/24 | 6240R;6238R;6212U;8276; 8260;8260M;8260L;8276M;8276L | C30 | C35 | C30 |
| 150W | 26/24/20 | 8164; 8160; 6148 | C30 | C35 | C30 |
| 150W | 16/12 | 6142; 6136; 8158 | C30 | C35 | C30 |
| 150W | 24 | 8160T | C25, DIMM limit 2* | C25, DIMM limit 2* | C25, DIMM limit 2* |
| 150W | 8 | 6244 | C25, Special limit* | C30, DIMM limit 1* | C25, Special limit* |
| 150W | 24/20/18/16 | 6248;6240;6242;6252;6210U;6240M | C30 | C35 | C30 |
| 150W | 24/16/8 | 6252N | C25, Special limit* | C30, DIMM limit 1* | C25, Special limit* |
| 150W | 16/26/16/24 | 6226R/6230R/6208U/5220R | C30 | C35 | C30 |
| 140W | 22/8 | 6152; 6140 | C40E45 | C40E45 | C35 |
| 140W | 14 | 6132 | C30 | C35 | C30 |
| 140W | 22 | 6238;6238M | C40E45 | C40E45 | C35 |
| 135W | 24 | 6262V | C40E45 | C40E45 | C35 |
| 130W | 8 | 6234 | C40E45 | C40E45 | C35 |
| 130W | 8 | 6134 | C30 | C35 | C30 |
| 130W | 8 | 4215R | C30 | C35 | C30 |
| 125W | 20/16 | 6138; 6130; 8153 | C40E45 | C40E45 | C35 |
| 125W | 12 | 6126 | C40E45 | C40E45 | C35 |
| 125W | 20 | 6138T | C30 | C35 | C30 |
| 125W | 16 | 6130T | C30 | C35 | C30 |
| 125W | 12 | 6126T | C30 | C35 | C30 |
| 125W | 20/18/16/12 |
6209U;6230;5220S;5218;8253;6226;5220 |
C40E45 | C40E45 | C35 |
| 125W | 20/16/4 | 6230N | C35 | C35 | C35 |
| 125W | 20 | 5218R | C40E45 | C40E45 | C35 |
| 115W | 6 | 6128 | C30 | C35 | C30 |
| 115W | 8 | 5217 | C35 | C35 | C35 |
| 115W | 20 | 6222V | C35 | C35 | C35 |
| 105W | 4 | 5122; 8156 | C30 | C35 | C30 |
| 105W | 14/12 | 5120; 5118 | C40E45 | C40E45 | C40E45 |
| 105W | 14 | 5120T | C30 | C35 | C30 |
| 105W | 4 | 5222/8256 | C30 | C35 | C30 |
| 105W | 16 | 5218T | C30 | C30 | C30 |
| 100W | 16 | 4216 | C40E45 | C40E45 | C40E45 |
| 95W | 10 | 4210T | C40E45 | C40E45 | C40E45 |
| 85W | 12/10/8/6/4 | 4116; 5115; 4114; 4110; 4108; 3106; 3104; 4112 | C40E45 | C40E45 | C40E45 |
| 85W | 14 | 5119T | C40E45 | C40E45 | C40E45 |
| 85W | 12 | 4116T | C40E45 | C40E45 | C40E45 |
| 85W | 10 | 4114T | C40E45 | C40E45 | C40E45 |
| 85W | 12/10/8/6 | 5215;4215;4214;4216; 4210;4208;3204;5215M;5215L | C40E45 | C40E45 | C40E45 |
| 70W | 8 | 4109T | C40E45 | C40E45 | C40E45 |
* DIMM limit 1 – Max 64 GB LRDIMMs. No 128 GB, No AEP(Apache Pass). This is applicable only for systems with dual processors.
* DIMM limit 2– Max 32 GB LRDIMMs. No 128 GB/ 64 GB, No AEP(Apache Pass). This is applicable only for systems with dual processors.
* Special limit – No drives, No Backplane, No PCIe, and Max 64GB LRDIMM
**C indicates that the processor is continuously operating at the specified temperature or lower.
***E indicates the expanded operating temperature specified for the processor.
* Not Supported - Only supported in a 1 socket config at ambient 30C