Сегодня покупают
← Вернуться назад
Нужна помощь с конфигурацией?
Пришлите SKU, спецификацию или список требований. Специалист Apltech проверит совместимость компонентов и найдёт актуальные артикулы
Получить консультацию →

Dell EMC PowerEdge FC640: технические характеристики и спецификации

System dimensions

Figure 1. System dimensions
This image shows System dimensions
Table 1. System dimensions of the Dell EMCPowerEdgeFC640systemSystem dimensions
SystemXYZ (handle closed)
Dell EMCPowerEdgeFC640211.0 mm (8.3-inches)40.25 mm (1.58-inches)535.75 mm (21.09-inches)

System weight

Table 1. Dell EMC PowerEdge FC640 system weightSystem weight
SystemMaximum weight
2 x 2.5-inch drive5.8 kg (12.79 lb)

Processor specifications

The Dell EMC PowerEdge FC640 system supports up to two Intel Xeon Scalable Processors.

Supported operating systems

The PowerEdge FC640 supports the following operating systems:
  • Canonical Ubuntu LTS
  • Citrix XenServer
  • Microsoft Windows Server
  • Red Hat Enterprise Linux
  • SUSE Linux Enterprise Server
  • VMware
For more information, go to www.dell.com/ossupport

System battery specifications

The Dell EMC PowerEdge FC640 system supports CR 2032 3.0-V lithium coin cell system battery.

Memory specifications

Table 1. Memory specificationsThe table below shows the memory specifications.
Memory module socketsDIMM type DIMM rank DIMM capacity Single processor Dual processors
Minimum RAM Maximum RAM Minimum RAM Maximum RAM
Sixteen 288-pinsLRDIMMOcta rank128 GB128 GB1024 GB256 GB2048 GB
Quad rank 64 GB 64 GB 512 GB 128 GB 1024 GB
RDIMM Single rank 8 GB 8 GB 64 GB 16 GB 128 GB
Dual rank 16 GB 16 GB 128 GB 32 GB 256 GB
Dual rank 32 GB 32 GB 256 GB 64 GB 512 GB
Dual rank 64 GB64 GB512 GB128 GB1024 GB

Mezzanine card specifications

The Dell EMC PowerEdge FC640 system supports two PCIe x8 Gen 3 slots mezzanine card supporting dual port 10 Gb Ethernet, quad port 1 Gb, FC8 Fibre Channel, FC16 Fibre Channel, or Infiniband mezzanine cards.

Storage controller specifications

The Dell EMC PowerEdge FC640 system supports:

Internal Controllers: Software RAID S140,PERC9 H330,H730P

Boot Optimized Storage Subsystem:
  • HWRAID 2 x M.2 SSDs 120GB, 240 GB
  • Internal Dual SD Module optional

Hard drives

The Dell EMC PowerEdge FC640 system supports up to two 2.5-inch SAS or SATA hard drives or PCIe SSDs. The hard drives or SSDs are supplied in a hot-swappable drive carriers that fit in the drive bays and these drives connect to the system board through the drive backplane.

USB ports

The Dell EMC PowerEdge FC640 system supports:
  • One USB 3.0-compliant port on the front of the system
  • One micro USB/iDRAC direct USB 2.0-compliant port on the front of the system
  • One USB 3.0-compliant internal port
NOTE The micro USB 2.0-compliant port on the front of the system can only be used as an iDRAC Direct or a management port.

Internal Dual SD Module

The Dell EMC PowerEdge FC640 system supports two internal micro SD cards dedicated for the hypervisor. This card offers the following features:
  • Dual card operation — maintains a mirrored configuration by using micro SD cards in both slots and provides redundancy.
  • Single card operation — single card operation is supported, but without redundancy.
NOTE One IDSDM card slot is dedicated for redundancy. It is recommended to use Dell branded micro SD cards associated with the IDSDM/micro SD vFlash configured systems.

Micro SD vFlash connector

The Dell EMC PowerEdge FC640 system supports one dedicated micro SD card for vFlash support.

Video specifications

Table 1. Video specificationsThe following table provides the video specifications for the Dell EMC PowerEdge FC640 system.
Features Specifications
Video type Matrox G200eW3 graphics controller integrated with iDRAC
Video memory 4 GB DDR4 shared with iDRAC application memory

Environmental specifications

NOTE For additional information about environmental certifications, please refer to the Product Environmental Datasheet located with the Manuals & Documents on www.dell.com/poweredgemanuals
Table 1. Temperature specificationsWhen the system is in continuous operation (for altitude less than 950 m or 3117 ft), the temperature specification ranges from 10°C to 35°C (50°F to 95°F) with no direct sunlight on the equipment. NOTE: Maximum of 145 W 22 core processor is supported in systems with eight 2.5-inches drives, two PCI slot chassis, and 75 W single wide active GPU. When the system is not in operation, the temperature specification is –40°C to 65°C (–40°F to 149°F). The Maximum temperature gradient for both opertaion and non-opertaional systems is 20°C/h (36°F/h).
Temperature Specifications
Storage –40°C to 65°C (–40°F to 149°F)
Continuous operation (for altitude less than 950 m or 3117 ft) 10°C to 35°C (50°F to 95°F) with no direct sunlight on the equipment.
Maximum temperature gradient (operating and storage) 20°C/h (68°F/h)
Table 2. Relative humidity specificationsFor a non-operational system, the ambient relative humidity ranges from 5% to 95% with 33°C (91°F) maximum dew point. Atmosphere must be non-condensing at all times. For an operational system, the ambient relative humidity ranges from 10% to 80% with 29°C (84.2°F) maximum dew point.
Relative humidity Specifications
Storage 5% to 95% RH with 33°C (91°F) maximum dew point. Atmosphere must be non-condensing at all times.
Operating 10% to 80% relative humidity with 26°C (78.8°F) maximum dew point.
Table 3. Maximum vibration specificationsThe maximum vibration specification of an operational system is 0.26 Grms at 5 Hz to 350 Hz (all operation orientations).The maximum vibration specification of a non-operational system is 1.87 Grms at 10 Hz to 500 Hz for 15 min (all six sides tested).
Maximum vibration Specifications
Operating 0.26 Grms at 5 Hz to 350 Hz (all operation orientations).
Storage 1.87 Grms at 10 Hz to 500 Hz for 15 min (all six sides tested).
Table 4. Maximum shock specificationsThe maximum shock specification of an operational system is six consecutively executed shock pulses in the positive and negative x, y, and z axes of 6 G for up to 11 ms. The maximum shock specification of a non-operational system is six consecutively executed shock pulses in the positive and negative x, y, and z axes (one pulse on each side of the system) of 71 G for up to 2 ms.
Maximum shock Specifications
Operating Six consecutively executed shock pulses in the positive and negative x, y, and z axes of 6 G for up to 11 ms.
Storage Six consecutively executed shock pulses in the positive and negative x, y, and z axes (one pulse on each side of the system) of 71 G for up to 2 ms.
Table 5. Maximum altitude specificationsThe maximum altitude specification for an operational system is 3048 m (10,000 ft). The maximum altitude specification for a non-operational system is 12,000 m (39,370 ft).
Maximum altitude Specifications
Operating

3048 m (10,000 ft)

Storage 12,000 m (39,370 ft)
Table 6. Operating temperature de-rating specificationsIf the operating temerature of a system is up to 35 °C (95 °F), the maximum temperature is reduced by 1 °C/300 m (1 °F/547 ft) above 950 m (3,117 ft). If the operating temperature of a system ranges from 35 °C to 40 °C (95 °F to 104 °F), the maximum temperature is reduced by 1 °C/175 m (1 °F/319 ft) above 950 m (3,117 ft). If the operating temperature of a system ranges from 40 °C to 45 °C (104 °F to 113 °F), the maximum temperature is reduced by 1 °C/125 m (1 °F/228 ft) above 950 m (3,117 ft).
Operating temperature de-rating Specifications
Up to 35°C (95°F) Maximum temperature is reduced by 1°C/300 m (1°F/547 ft) above 950 m (3,117 ft).
35°C to 40°C (95°F to 104°F) Maximum temperature is reduced by 1°C/175 m (1°F/319 ft) above 950 m (3,117 ft).
40°C to 45°C (104°F to 113°F) Maximum temperature is reduced by 1°C/125 m (1°F/228 ft) above 950 m (3,117 ft).

Particulate and gaseous contamination specifications

The following table defines the limitations that help avoid any equipment damage or failure from particulates and gaseous contamination. If the levels of particulates or gaseous pollution exceed the specified limitations and result in equipment damage or failure, you may need to rectify the environmental conditions. Re-mediation of environmental conditions is the responsibility of the customer.
Table 1. Particulate contamination specificationsAir filtration specification: Data center air filtration as defined by ISO Class 8 per ISO 14644-1 shpuld have a 95% upper confidence limit. Note: This condition applies only to data center environments. Air filtration requirements do not apply to IT equipment designed to be used outside a data center, in environments such as an office or factory floor. Note: Air entering the data center must have MERV11 or MERV13 filtration. Conductive dust specification: Air must be free of conductive dust, zinc whiskers, or other conductive particles. Note: This condition applies to data center and non-data center environments. Corrosive dust specification: Air must be free of corrosive dust. Residual dust present in the air must have a deliquescent point less than 60% relative humidity. Note: This condition applies to data center and non-data center environments.
Particulate contamination Specifications
Air filtration Data center air filtration as defined by ISO Class 8 per ISO 14644-1 with a 95% upper confidence limit.
NOTE This condition applies to data center environments only. Air filtration requirements do not apply to IT equipment designed to be used outside a data center, in environments such as an office or factory floor.
NOTE Air entering the data center must have MERV11 or MERV13 filtration.
Conductive dust Air must be free of conductive dust, zinc whiskers, or other conductive particles.
NOTE This condition applies to data center and non-data center environments.
Corrosive dust
  • Air must be free of corrosive dust.
  • Residual dust present in the air must have a deliquescent point less than 60% relative humidity.
NOTE This condition applies to data center and non-data center environments.
Table 2. Gaseous contamination specificationsThe copper coupon corrosion rate is <300 Å/month per Class G1 as defined by ANSI/ISA71.04-1985. The silver coupon corrosion rate is <200 Å/month as defined by AHSRAE TC9.9.
Gaseous contamination Specifications
Copper coupon corrosion rate <300 Å/month per Class G1 as defined by ANSI/ISA71.04-1985.
Silver coupon corrosion rate <200 Å/month as defined by AHSRAE TC9.9.
NOTE Maximum corrosive contaminant levels measured at ≤50% relative humidity.

Standard operating temperature

Table 1. Standard operating temperature specificationsThe standard operating temperature for altitude less than 950 metres or 3117 feet ranges from 10°C to 35°C (50°F to 95°F) with no direct sunlight on the equipment. Note: The 2.5-inch hard drive chassis supports a maximum of 145 W processors.
Standard operating temperature Specifications
Continuous operation (for altitude less than 950 m or 3117 ft) 10°C to 35°C (50°F to 95°F) with no direct sunlight on the equipment.
Humidity percentage range 10% to 80% Relative Humidity with 26°C (78.8°F) maximum dew point.

Expanded operating temperature

Table 1. Expanded operating temperature specificationsWhen the system is in continuous operation, the expanded operating temperature ranges from 5°C to 40°C at 5% to 85% RH with 29°C dew point. NOTE: Outside the standard operating temperature (10°C to 35°C), the system can operate continuously in temperatures as low as 5°C and as high as 40°C. For temperatures between 35°C and 40°C, de-rate maximum allowable dry bulb temperature by 1°C per 175 m above 950 m (1°F per 319 ft). When the system is operating at < 1% of annual operating hours, the expanded operating temperature is –5°C to 45°C at 5% to 90% RH with 29°C dew point. NOTE: Outside the standard operating temperature (10°C to 35°C), the system can operate down to –5°C or up to 45°C for a maximum of 1% of its annual operating hours. For temperatures between 40°C and 45°C, de-rate maximum allowable temperature by 1°C per 125 m above 950 m (1°F per 228 ft).
Expanded operating temperature Specifications
Continuous operation 5°C to 40°C at 5% to 85% RH with 29°C dew point.
NOTE Outside the standard operating temperature (10°C to 35°C), the system can operate continuously in temperatures as low as 5°C and as high as 40°C.

For temperatures between 35°C and 40°C, de-rate maximum allowable dry bulb temperature by 1°C per 175 m above 950 m (1°F per 319 ft).

Less than or equal to 1% of annual operating hours –5°C to 45°C at 5% to 90% RH with 29°C dew point.
NOTE Outside the standard operating temperature (10°C to 35°C), the system can operate down to –5°C or up to 45°C for a maximum of 1% of its annual operating hours.

For temperatures between 40°C and 45°C, de-rate maximum allowable temperature by 1°C per 125 m above 950 m (1°F per 228 ft).

NOTE When operating in the expanded temperature range, system performance may be impacted.
NOTE When operating in the expanded temperature range, ambient temperature warnings maybe reported on the LCD panel and in the System Event Log.

Expanded operating temperature restrictions

The expanded operating temperature restrictions for the FC640 system are listed here:

  • Do not perform a cold startup below 5°C.
  • The operating temperature specified is for a maximum altitude of 3048 metres (10,000 feet ).
  • NVME drives are not supported.
  • AEP DIMMs are not supported.
  • 105 W/4 C, 115 W/6 C, 130 W/8 C, 140 W/14 C or higher wattage processor (TDP>140 W) are not supported.
  • NEBS SKU processors higher than 85 W are not supported.
  • Peripheral cards and /or peripheral cards greater than 25 W, that are not verified by Dell, are not supported.

Thermal Restriction matrix

Table 1. Thermal restrictions matrixThe following table describes the configuration required for efficient cooling.
Thermal Design Power (TDP) for the processor Core count Processors Ambient restriction
M1000e VRTX FX2
205W 28/24 8180; 8168 Not supported C25, DIMM limit 2* C25, Special limit*
205W 28/26/24 8280; 8270;8268;8280M;8280L Not supported C25, DIMM limit 2* C25, Special limit*
205W 24/16/20 6248R;6246R;6242R Not supported* Not supported* Not supported*
200W 18 6154;6254 Not supported C25, DIMM limit 2* C25, Special limit*
165W 28/26/18 8176; 8170; 6150 C30, DIMM limit 1* C35, DIMM limit 1* C30, DIMM limit 1*
165W 12 6246 C25, Special limit* C30, DIMM limit 1* C25, Special limit*
165W 28/24 6240R;6238R;6212U;8276; 8260;8260M;8260L;8276M;8276L C30 C35 C30
150W 26/24/20 8164; 8160; 6148 C30 C35 C30
150W 16/12 6142; 6136; 8158 C30 C35 C30
150W 24 8160T C25, DIMM limit 2* C25, DIMM limit 2* C25, DIMM limit 2*
150W 8 6244 C25, Special limit* C30, DIMM limit 1* C25, Special limit*
150W 24/20/18/16 6248;6240;6242;6252;6210U;6240M C30 C35 C30
150W 24/16/8 6252N C25, Special limit* C30, DIMM limit 1* C25, Special limit*
150W 16/26/16/24 6226R/6230R/6208U/5220R C30 C35 C30
140W 22/8 6152; 6140 C40E45 C40E45 C35
140W 14 6132 C30 C35 C30
140W 22 6238;6238M C40E45 C40E45 C35
135W 24 6262V C40E45 C40E45 C35
130W 8 6234 C40E45 C40E45 C35
130W 8 6134 C30 C35 C30
130W 8 4215R C30 C35 C30
125W 20/16 6138; 6130; 8153 C40E45 C40E45 C35
125W 12 6126 C40E45 C40E45 C35
125W 20 6138T C30 C35 C30
125W 16 6130T C30 C35 C30
125W 12 6126T C30 C35 C30
125W 20/18/16/12

6209U;6230;5220S;5218;8253;6226;5220

C40E45 C40E45 C35
125W 20/16/4 6230N C35 C35 C35
125W 20 5218R C40E45 C40E45 C35
115W 6 6128 C30 C35 C30
115W 8 5217 C35 C35 C35
115W 20 6222V C35 C35 C35
105W 4 5122; 8156 C30 C35 C30
105W 14/12 5120; 5118 C40E45 C40E45 C40E45
105W 14 5120T C30 C35 C30
105W 4 5222/8256 C30 C35 C30
105W 16 5218T C30 C30 C30
100W 16 4216 C40E45 C40E45 C40E45
95W 10 4210T C40E45 C40E45 C40E45
85W 12/10/8/6/4 4116; 5115; 4114; 4110; 4108; 3106; 3104; 4112 C40E45 C40E45 C40E45
85W 14 5119T C40E45 C40E45 C40E45
85W 12 4116T C40E45 C40E45 C40E45
85W 10 4114T C40E45 C40E45 C40E45
85W 12/10/8/6 5215;4215;4214;4216; 4210;4208;3204;5215M;5215L C40E45 C40E45 C40E45
70W 8 4109T C40E45 C40E45 C40E45

* DIMM limit 1 – Max 64 GB LRDIMMs. No 128 GB, No AEP(Apache Pass). This is applicable only for systems with dual processors.

* DIMM limit 2– Max 32 GB LRDIMMs. No 128 GB/ 64 GB, No AEP(Apache Pass). This is applicable only for systems with dual processors.

* Special limit – No drives, No Backplane, No PCIe, and Max 64GB LRDIMM

**C indicates that the processor is continuously operating at the specified temperature or lower.

***E indicates the expanded operating temperature specified for the processor.

* Not Supported - Only supported in a 1 socket config at ambient 30C