Technical Specifications
| Physical disks | Up to sixty 3.5 inch or 2.5 inch SAS or nearline SAS physical disks or 2.5 inch SAS SSDs | |
| RAID controller modules | Two hot-swappable modules
with temperature sensors
4 GB or 8 GB of cache per controller |
|
| Dell PowerVault MD3860i storage arrays | Provides host-to-controller 10 Gbps iSCSI connection and two 12 Gbps SAS connections | |
| Dell PowerVault MD3060e expansion enclosures | Supports 120 physical disks,
in addition to 60 physical disks in the RAID enclosure
Redundant path connectivity provides redundant data paths to each hard drive
|
||
| SAS connectors | Two SAS IN ports to connect
hosts
One SAS OUT port for expansion to an additional PowerVault MD3060e expansion enclosure
|
||
| Serial connector (debug port) | Six pin port
|
||
| SAS connectors |
Two SAS IN ports to connect hosts
Two SAS OUT ports, it is recommended that you use the first port for expansion to an additional PowerVault MD3060e expansion enclosure. Only one expansion port is supported at any given time.
|
|
| Serial connector (debug port) |
One 6-pin mini serial port
|
|
| Management Ethernet connector | One 100/1000 Mbps Ethernet connection for out-of-band management of the enclosure and the second Ethernet port is reserved. | |
| iSCSI connectors |
Two 10 Gbps iSCSI IN connectors
to connect hosts
|
| AC power supply (per power supply) | ||
| Wattage | 1755 W | |
Heat dissipation (maximum)
|
5988 BTU/hr | |
Voltage
|
220 V AC, autoranging, 50 Hz/60 Hz | |
| Battery | 6.6 V DC, 1100 mAh, 7.26 W Lithium ion battery | |
|
||
| Temperature | ||
| Operating | Continuous operation: 10
°C to 35 °C (50 °F to 95 °F) at 20% to 80% relative humidity (RH),
with 26 °C maximum dew point. De-rate maximum allowable dry bulb temperature
at 1 °C/300 m (1 °F per 550 ft) above 900 m (2952.75 ft).
|
|
| Storage | –40 °C to 65 °C (–40 °F to 149 °F) with a maximum temperature gradation of 20 °C per hour | |
| Relative humidity | ||
| Operating | 20% to 80% (noncondensing) with maximum humidity gradation of 10% per hour | |
| Storage | 5% to 95% at a maximum wet bulb temperature of 38 °C (100.4 °F) | |
| Maximum vibration | ||
| Operating | 0.26 G rms at 5 Hz to 350 Hz in operational orientation | |
| Storage | 1.88 G rms at 10 Hz to 500 Hz for 15 minutes (all six sides tested) | |
| Maximum shock | ||
| Operating |
One shock pulse in the positive z axis of the system at 31 G for 2.6 ms in the operational orientation |
|
| Storage | Six consecutively executed
shock pulses in the positive and negative x, y, and z axes (one pulse
on each side of the system) at 71 G for up to 2 ms
Six consecutively executed shock pulses in the positive and negative x, y, and z axes (one pulse on each side of the system) of 22 G faired square wave pulse with velocity change at 200 inches/second (508 centimeters/second) |
|
| Altitude | ||
| Operating | Maximum 3000 m (9,842 ft) | |
| Storage | Maximum 12192 m (40,000 ft) | |
| Airborne contaminant level | ||
| Class | G1 as defined by ISA-S71.04-1985 | |