Technical Specifications
| Physical disks | Up to twelve 3.5 inch or twenty-four 2.5 inch SAS, nearline SAS physical disks, or SAS SSDs | |
| RAID controller modules | Two hot-swappable modules
with temperature sensors
4GB or 8GB of cache per controller |
|
| Provides host-to-controller 12 Gbps SAS connection | ||
| Dell PowerVault MD1200 and MD1220 expansion enclosures | Each expansion enclosure
holds Up to twelve 3.5 inch or twenty-four 2.5 inch SAS, nearline
SAS physical disks, or SAS SSDs
Redundant path connectivity provides redundant data paths to each hard drive
|
||
| SAS connectors | Two SAS IN ports to connect
hosts
One SAS OUT port for expansion to additional PowerVault MD1200 or MD1220 expansion enclosure
|
||
| Serial connector (debug port) | One 6-pin mini-DIN connector
|
||
| SAS connectors |
Four SAS IN ports to connect
to hosts
|
|
| Serial connector (debug port) | One mini-USB port
|
|
| Management Ethernet connector | One 100/1000 Mbps Ethernet connection for out-of-band management of the enclosure (MGMT) |
| AC power supply (per power supply) | ||
| Wattage | 600 W | |
Heat dissipation (maximum)
|
100 W | |
Voltage
|
100–220 V AC, (8.6 A-4.3 A) | |
| Battery | 6.6 V DC, 1100 mAh, 7.26 W Lithium ion battery | |
|
||
| Temperature | ||
| Operating | Continuous operation: 10
°C to 35 °C (50 °F to 95 °F) at 20% to 80% relative humidity (RH),
with 26 °C maximum dew point. De-rate maximum allowable dry bulb temperature
at 1 °C/300 m (1 °F per 550 ft) above 900 m (2952.75 ft).
|
|
| Storage | –40 °C to 65 °C (–40 °F to 149 °F) with a maximum temperature gradation of 20 °C per hour | |
| Relative humidity | ||
| Operating | 10% to 80% (noncondensing) with maximum humidity gradation of 10% per hour | |
| Storage | 5% to 95% at a maximum wet bulb temperature of 33 °C (91 °F) | |
| Maximum vibration | ||
| Operating | 0.26 G rms at 5 Hz to 350 Hz in operational orientation | |
| Storage | 1.88 G rms at 10 Hz to 500 Hz for 15 minutes (all six sides tested) | |
| Maximum shock | ||
| Operating |
One shock pulse in the positive z axis of the system at 31 G for 2.6 ms in the operational orientation |
|
| Storage | Six consecutively executed shock pulses in the positive and negative x, y, and z axes (one pulse on each side of the system) at 71 G for up to 2 ms | |
| Altitude | ||
| Operating | Maximum 3000 m (9842.5 ft)
|
|
| Storage | Maximum 12192 m ( 40,000 ft) | |
| Airborne contaminant level | ||
| Class | G1 as defined by ISA-S71.04-1985 | |
|
||
Air Filtration
|
Data center air filtration as defined
by ISO Class 8 per ISO 14644-1 with a 95% upper confidence limit.
|
|
Conductive Dust
|
Air must be free of conductive dust, zinc whiskers, or other conductive particles. | |
Corrosive Dust
|
|
|
| Gaseous Contamination | ||
|
||
| Copper Coupon Corrosion Rate | <300 Å/month per Class G1 as defined by ANSI/ISA71.04-1985. | |
| Silver Coupon Corrosion Rate | <200 Å/month as defined by AHSRAE TC9.9. | |