Dell PowerVault MD3400 and MD3420 Storage Arrays: руководство по обслуживанию

Technical Specifications

Table 1. Physical Disks. This describes physical disks.
Physical disks Up to twelve 3.5 inch or twenty-four 2.5 inch SAS, nearline SAS physical disks, or SAS SSDs
Table 2. RAID Controller Modules . This describes RAID Controller Modules
RAID controller modules Two hot-swappable modules with temperature sensors

4GB or 8GB of cache per controller

    Provides host-to-controller 12 Gbps SAS connection
     
     
Table 3. Expansion Modules. This describes Expansion Modules
Dell PowerVault MD1200 and MD1220 expansion enclosures Each expansion enclosure holds Up to twelve 3.5 inch or twenty-four 2.5 inch SAS, nearline SAS physical disks, or SAS SSDs

Redundant path connectivity provides redundant data paths to each hard drive

  • NOTE: Support for 192 physical disks is a premium feature and requires activation.
  SAS connectors Two SAS IN ports to connect hosts

One SAS OUT port for expansion to additional PowerVault MD1200 or MD1220 expansion enclosure

  • NOTE: SAS connectors are SFF-8088 compliant.
  Serial connector (debug port) One 6-pin mini-DIN connector
  • NOTE: For technical support use only.
Table 4. Back-Panel Connectors (Per RAID Controller Module) . This describes Back-Panel Connectors (Per RAID Controller Module
  SAS connectors Four SAS IN ports to connect to hosts
  • NOTE: SAS connectors are SFF-8088 compliant.
  • NOTE: It is recommended that you use one port.
     
     
  Serial connector (debug port) One mini-USB port
  • NOTE: For technical support use only.
  Management Ethernet connector One 100/1000 Mbps Ethernet connection for out-of-band management of the enclosure (MGMT)
Table 5. Power . This describes power
AC power supply (per power supply)  
  Wattage 600 W
  Heat dissipation (maximum)
  • NOTE: Heat dissipation is calculated using the power supply wattage rating. The heat dissipation values are for the entire system which includes chassis and two controllers.
100 W
  Voltage
  • NOTE: This system is also designed to be connected to IT power systems with a phase to phase voltage not exceeding 230 V.
100–220 V AC, (8.6 A-4.3 A)
Battery 6.6 V DC, 1100 mAh, 7.26 W Lithium ion battery
Table 6. Environmental. This describes Environmental
   
  • NOTE: For additional information about environmental measurements for specific system configurations, see dell.com/environmental_datasheets.
Temperature  
  Operating Continuous operation: 10 °C to 35 °C (50 °F to 95 °F) at 20% to 80% relative humidity (RH), with 26 °C maximum dew point. De-rate maximum allowable dry bulb temperature at 1 °C/300 m (1 °F per 550 ft) above 900 m (2952.75 ft).
  • NOTE: For information on supported expanded operating temperature range and configurations, see the Owner's Manual at dell.com/powervaultmanuals.
  Storage –40 °C to 65 °C (–40 °F to 149 °F) with a maximum temperature gradation of 20 °C per hour
Relative humidity  
  Operating 10% to 80% (noncondensing) with maximum humidity gradation of 10% per hour
  Storage 5% to 95% at a maximum wet bulb temperature of 33 °C (91 °F)
Maximum vibration  
  Operating 0.26 G rms at 5 Hz to 350 Hz in operational orientation
  Storage 1.88 G rms at 10 Hz to 500 Hz for 15 minutes (all six sides tested)
Maximum shock  
  Operating

One shock pulse in the positive z axis of the system at 31 G for 2.6 ms in the operational orientation

  Storage Six consecutively executed shock pulses in the positive and negative x, y, and z axes (one pulse on each side of the system) at 71 G for up to 2 ms
Altitude  
  Operating Maximum 3000 m (9842.5 ft)
  • NOTE: For altitudes above 2950 ft, the maximum operating temperature is derated 1.8 ºF/1000 ft.
  Storage Maximum 12192 m ( 40,000 ft)
Airborne contaminant level
  Class G1 as defined by ISA-S71.04-1985
 
 
 
 
 
Table 7. Particulate Contamination . This describes Particulate Contamination
  • NOTE: This section defines the limits to help avoid IT equipment damage and/or failure from particulates and gaseous contamination. If it is determined that levels of particulates or gaseous pollution are beyond the limits specified below and are the reason for the damage and/or failures to your equipment, it may be necessary for you to re-mediate the environmental conditions that are causing the damage and/or failures. Re-mediation of environmental conditions will be the responsibility of the customer.
  Air Filtration
  • NOTE: Applies to data center environments only. Air filtration requirements do not apply to IT equipment designed to be used outside a data center, in environments such as an office or factory floor.
Data center air filtration as defined by ISO Class 8 per ISO 14644-1 with a 95% upper confidence limit.
  • NOTE: Air entering the data center must have MERV11 or MERV13 filtration.
  Conductive Dust
  • NOTE: Applies to data center and non-data center environments.
Air must be free of conductive dust, zinc whiskers, or other conductive particles.
  Corrosive Dust
  • NOTE: Applies to data center and non-data center environments.
  • Air must be free of corrosive dust.
  • Residual dust present in the air must have a deliquescent point less than 60% relative humidity.
Gaseous Contamination
  • NOTE: Maximum corrosive contaminant levels measured at ≤50% relative humidity.
  Copper Coupon Corrosion Rate <300 Å/month per Class G1 as defined by ANSI/ISA71.04-1985.
  Silver Coupon Corrosion Rate <200 Å/month as defined by AHSRAE TC9.9.