Technical specifications

The technical specifications of the MD1280 are displayed in the following tables.
Table 1. Technical specifications. This table provides technical specifications of MD1280

Specifications

Drives

SAS hard drives

Up to 84 SAS hot-swappable hard drives (6.0 Gbps or 12.0 Gbps) and SSDs

Enclosure Management Modules (EMM)

EMMs

Two hot-swappable I/O EMM modules

Connectivity

Configurations

Various server-attached configurations as specified by your solution provider.

Backpanel Connectors

SAS connectors

  • Asymmetric SAS Cabling for connection to the host and for expansion to an additional enclosure

  • Support Mini-SAS to Mini-SAS cable universally keyed for the following lengths that are currently supported: 0.5m–6m

  • NOTE: SAS connectors are SFF-8086/SFF-8088-compliant.

LED Indicators

Front panel

  • One two-digit LCD indicator for Unit ID, error code, and unit location identifier

  • One two-color LED indicator for power status

  • One single-color LED indicator for module fault status (enclosure as a whole)

  • One single-color LED indicator for logical fault status (hard drive, HBA, RAID controller)

  • One single-color LED indicator for drive drawer 1 fault status

  • One single-color LED indicator for drive drawer 2 fault status

Disk Drive In Carrier (DDIC)

One single-color LED for hard drive fault status

6 Gbps SAS I/O module

14 one-color LED status indicators, four each for the three SAS ports, and two for the module status

Fan module

  • One single-color LED indicator for module status
  • One single-color LED indicator for battery fault status (not currently used)
  • One single-color LED indicator for fan fault status
  • One single-color LED indicator for power status

PSU

  • One single‐color LED indicator for PSU fault status
  • One single‐color LED indicator for AC fault status
  • One single‐color LED indicator for power status

Power Supply Units (per PSU)

Watt

2.8 kW

Voltage

200–240 VAC (8.6 A–4.3 A)

Heat dissipation

191–147 W

Maximum inrush current

Under typical line conditions and over the entire system ambient operating range, the inrush current may reach 55 A for each PSU for 10 ms or less.

Available Hard Drive Power (Per Slot)

Supported hard drive power consumption (continuous)

Up to 1.16 A at +5 V,  Up to 1.6 A at +12 V

I/O Card Power (Per Slot)

Maximum power consumed by I/O Card

11 W at +12 V

Maximum available power

100 W at +12 V

Maximum available power

1 W at +5 V (standby)

Physical

Height

22.23 cm (8.75 inches)

Width

48.26 cm (19 inches)

Depth (front mounting bracket to rear surface)

91.5 cm (36 inches)

Depth (front surface to rear surface)

96 cm (38 inches)

Full Weight (maximum configuration)

130.7 kg (287.5 lb)

Shipping Weight (without hard drives)

62 kg (137 lb)

Environmental

  • NOTE: For more information about environmental measurements for specific system configurations, see Dell.com/environmental_datasheets.

Storage

–40°C to 65°C (–40°F to 149°F) at a maximum altitude of 12,000 m (39,370 ft)

Relative humidity

Operating

10 percent to 80 percent (non-condensing) with 29°C (82.4°F) maximum dewpoint

Storage

5 percent to 95 percent (noncondensing) with 33°C (91°F) maximum dewpoint

Maximum vibration

Operating

0.21 g at 5–500 Hz for 15 min

Storage

1.04 g at 2–200 Hz for 15 min

Maximum shock

Operating

Half-sine shock 5 g +/- 5 percent with a pulse duration of 10 ms +/- 10 percent in operational orientations only

Storage

  • z-axis: 30 g 10 ms half-sine
  • x-axis and y-axis: 20 g 10 ms half-sine

Altitude

Operating

–16 m to 3048 m (–50 ft to 10,000 ft)

 
  • NOTE: Maximum 35°C up to 2134 m (7000 ft), derate to 30°C for 2134 m to 3000 m (7000 ft to 10,000 ft).

Storage

–16 m to 10,600 m (–50 ft to 35,000 ft)

Airborne Contaminant Level

Class

G2 or lower as defined by ISA-S71.04-1985