Technical specifications
|
Specifications |
|
|---|---|
|
Drives |
|
|
SAS hard drives |
Up to 84 SAS hot-swappable hard drives (6.0 Gbps or 12.0 Gbps) and SSDs |
|
Enclosure Management Modules (EMM) |
|
|
EMMs |
Two hot-swappable I/O EMM modules |
|
Connectivity |
|
|
Configurations |
Various server-attached configurations as specified by your solution provider. |
|
Backpanel Connectors |
|
|
SAS connectors |
|
|
LED Indicators |
|
|
Front panel |
|
|
Disk Drive In Carrier (DDIC) |
One single-color LED for hard drive fault status |
|
6 Gbps SAS I/O module |
14 one-color LED status indicators, four each for the three SAS ports, and two for the module status |
|
Fan module |
|
|
PSU |
|
|
Power Supply Units (per PSU) |
|
|
Watt |
2.8 kW |
|
Voltage |
200–240 VAC (8.6 A–4.3 A) |
|
Heat dissipation |
191–147 W |
|
Maximum inrush current |
Under typical line conditions and over the entire system ambient operating range, the inrush current may reach 55 A for each PSU for 10 ms or less. |
|
Available Hard Drive Power (Per Slot) |
|
|
Supported hard drive power consumption (continuous) |
Up to 1.16 A at +5 V, Up to 1.6 A at +12 V |
|
I/O Card Power (Per Slot) |
|
|
Maximum power consumed by I/O Card |
11 W at +12 V |
|
Maximum available power |
100 W at +12 V |
|
Maximum available power |
1 W at +5 V (standby) |
|
Physical |
|
|
Height |
22.23 cm (8.75 inches) |
|
Width |
48.26 cm (19 inches) |
|
Depth (front mounting bracket to rear surface) |
91.5 cm (36 inches) |
|
Depth (front surface to rear surface) |
96 cm (38 inches) |
|
Full Weight (maximum configuration) |
130.7 kg (287.5 lb) |
|
Shipping Weight (without hard drives) |
62 kg (137 lb) |
|
Environmental |
|
|
|
|
Storage |
–40°C to 65°C (–40°F to 149°F) at a maximum altitude of 12,000 m (39,370 ft) |
|
Relative humidity |
|
|
Operating |
10 percent to 80 percent (non-condensing) with 29°C (82.4°F) maximum dewpoint |
|
Storage |
5 percent to 95 percent (noncondensing) with 33°C (91°F) maximum dewpoint |
|
Maximum vibration |
|
|
Operating |
0.21 g at 5–500 Hz for 15 min |
|
Storage |
1.04 g at 2–200 Hz for 15 min |
|
Maximum shock |
|
|
Operating |
Half-sine shock 5 g +/- 5 percent with a pulse duration of 10 ms +/- 10 percent in operational orientations only |
|
Storage |
|
|
Altitude |
|
|
Operating |
–16 m to 3048 m (–50 ft to 10,000 ft) |
|
|
|
Storage |
–16 m to 10,600 m (–50 ft to 35,000 ft) |
|
Airborne Contaminant Level |
|
|
Class |