Technical specifications
| Physical disks | Up to sixty 3.5 inch or 2.5 inch SAS or nearline SAS physical disks or 2.5 inch SAS SSDs | |
| RAID controller modules | Two hot-swappable modules
with temperature sensors 4 GB or 8 GB of cache per controller |
|
| Dell PowerVault MD3860f storage arrays | Provides host-to-controller 16 Gbps FC connection and two 12 Gbps SAS connections | |
| Dell PowerVault MD3060e expansion enclosures | Supports 120 physical disks,
in addition to 60 physical disks in the RAID enclosure Redundant path connectivity provides redundant data paths to each hard drive NOTE Support for 180 physical disk slots is a premium feature and requires
activation. The maximum number of physical disk slots supported without
using the premium feature is 120. |
||
| SAS connectors | Two SAS IN ports to connect
hosts One SAS OUT port for expansion to an additional PowerVault MD3060e expansion enclosure NOTE SAS connectors are
SFF-80644 compliant. |
||
| Serial connector (debug port) | Six pin port NOTE For technical support
use only. |
||
| SAS connectors | NOTE SAS and iSCSI connections to the
same host is not supported. Two SAS IN ports to connect hosts NOTE SAS
and FC connections
to the same host is not supported. Two SAS OUT ports, it is recommended that you use the first port for expansion to an additional PowerVault MD3060e expansion enclosure. Only one expansion port is supported at any given time. NOTE SAS connectors are
SFF-8644 compliant. |
|
| Serial connector (debug port) | One mini USB port NOTE For technical
support use only. |
|
| Management Ethernet connector | One 100/1000 Mbps Ethernet connection , labeled MGMT, for out-of-band management of the enclosure and the second Ethernet port is reserved. | |
| FC connectors | Four FC IN ports to connect hosts NOTE Directly
attaching to the FC ports is not supported. The host connection must
use a FC switch. |
| AC power supply (per power supply) | ||
| Wattage | 1755 W | |
| Heat dissipation (maximum) NOTE Heat dissipation is
calculated using the power supply wattage rating. The heat dissipation
values are for the entire system which includes chassis and two controllers. |
5988 BTU/hr | |
| Voltage NOTE This system is also
designed to be connected to IT power systems with a phase to phase
voltage not exceeding 230 V. |
220 V AC, autoranging, 50 Hz/60 Hz | |
| Battery | 6.6 V DC, 1100 mAh, 7.26 W Lithium ion battery | |
NOTE For additional
information about environmental measurements for specific system configurations,
see dell.com/environmental_datasheets. |
||
| Temperature | ||
| Operating | Continuous operation: 10
°C to 35 °C (50 °F to 95 °F) at 20% to 80% relative humidity (RH),
with 26 °C maximum dew point. De-rate maximum allowable dry bulb temperature
at 1 °C/300 m (1 °F per 550 ft) above 900 m (2952.75 ft). NOTE For information on
supported expanded operating temperature range and configurations,
see the Owner's Manual at dell.com/support/manuals. |
|
| Storage | –40 °C to 65 °C (–40 °F to 149 °F) with a maximum temperature gradation of 20 °C per hour | |
| Relative humidity | ||
| Operating | 20% to 80% (noncondensing) with maximum humidity gradation of 10% per hour | |
| Storage | 5% to 95% at a maximum wet bulb temperature of 38 °C (100.4 °F) | |
| Maximum vibration | ||
| Operating | 0.26 Grms at 5 Hz to 350 Hz in operational orientation | |
| Storage | 1.88 Grms at 10 Hz to 500 Hz for 15 minutes (all six sides tested) | |
| Maximum shock | ||
| Operating | One shock pulse in the positive z axis of the system at 31 G for 2.6 ms in the operational orientation |
|
| Storage | Six consecutively executed
shock pulses in the positive and negative x, y, and z axes (one pulse
on each side of the system) at 71 G for up to 2 ms Six consecutively executed shock pulses in the positive and negative x, y, and z axes (one pulse on each side of the system) of 22 G faired square wave pulse with velocity change at 200 inches/second (508 centimeters/second) |
|
| Altitude | ||
| Operating | Maximum 3000 m (9,842 ft) | |
| Storage | Maximum 12192 m (40,000 ft) | |
| Airborne contaminant level | ||
| Class | G1 as defined by ISA-S71.04-1985 | |