Dimensions and weight
| Physical | Dimensions |
|---|---|
| Height | 8.73 cm (3.44 inch) |
| Width | 48.2 cm (18.98 inch) |
| Depth | 75.58 cm (29.75 inch) |
| Maximum configuration weight | 36.5 kg (80.47 lb) (3.5–inch hard drive systems) |
| Empty weight | 23.2 kg (51.15 lb) (3.5–inch hard drive systems) |
Processor specifications
| Processor Type | Specification |
|---|---|
| Standard Edition | One or two Intel Xeon processors E5-2640 v4 product family |
| High Capacity Edition | One or two Intel Xeon processors E5–2660 v3 product family |
Expansion bus specifications
| Expansion card riser | PCIe slots on the riser | Height | Length | Link |
|---|---|---|---|---|
| Riser 1 | Slot 1 | half-height | low-profile | x8 |
| Riser 1 | Slot 2 | half-height | low-profile | x8 |
| Riser 1 | Slot 3 | half-height | low-profile | x8 |
| Riser 2 | Slot 4 | full-height | full-length | x16 |
| Riser 2 | Slot 5 | full-height | full-length | x8 |
| Riser 3 (default) | Slot 6 | full-height | full-length | x8 |
| Riser 3 | Slot 7 | full-height | full-length | x8 |
- NOTE: When using slots 1 through 4 on the riser, ensure that both the processors are installed on the system.
PSU specifications
| PSU | Class | Heat dissipation (maximum) | Frequency | Voltage |
|---|---|---|---|---|
| 1100 W AC | Platinum | 4100 BTU/hr | 50/60 Hz | 100–240 V AC, autoranging |
- NOTE: Heat dissipation is calculated using the PSU wattage rating.
- NOTE: This system is also designed to connect to the IT power systems with a phase to phase voltage not exceeding 230 V.
System battery specifications
Memory specifications
| Memory module sockets | Memory capacity | Minimum RAM | Maximum RAM |
|---|---|---|---|
| Twenty-four 288–pin | 4 GB single-ranked or 8 GB dual-ranked RDIMMs | 64 GB with a dual processor | Up to 128 GB with a dual processor |
| Memory module sockets | Memory capacity | Minimum RAM | Maximum RAM |
|---|---|---|---|
| Twenty-four 288–pin | 16 GB dual-ranked RDIMMs | 128 GB with a dual processor | Up to 256 GB with a dual processor |
Hard drives
The Dell DL4300 system supports up to twelve 3.5 inch and two 2.5 inch back-accessible and four 3.5 inch (in the hard-drive tray), internal, hot-swappable Nearline SAS drives in hard-drive slots 0 through 11 and 12 through 15.
USB ports
- USB 2.0-compliant ports on the front panel
- USB 3.0-complaint ports on the back panel
| System | Front panel | Back panel |
|---|---|---|
| Dell DL4300 system | One 4-pin, USB 2.0-compliant | Two 4-pin, USB 3.0-compliant |
NIC ports
- 1 Gbps
- 1 Gbps plus one 10 Gbps
The DL4300 High Capacity Edition system supports two 10 Gbps Network Interface Controller (NIC) ports on the back panel.
Serial connector
VGA ports
Internal Dual SD Module
Video specifications
| Video | Specification |
|---|---|
| Video type | Matrox G200eR2 |
| Video memory | 16 MB |
Environmental specifications
- NOTE: For additional information about environmental measurements for specific system configurations, see Dell.com/environmental_datasheets.
| Temperature | Specifications |
|---|---|
| Storage | –40°C to 65°C (–40°F to 149°F) |
| Continuous operation (for altitude less than 950 m or 3117 ft) | 10°C to 35°C (50°F to 95°F) with no direct sunlight on the equipment. |
| Fresh air | For information about fresh air, see Expanded Operating Temperature section. |
| Maximum temperature gradient (operating and storage) | 20°C/h (68°F/h) |
| Relative humidity | Specifications |
|---|---|
| Storage | 5% to 95% RH with 33°C (91°F) maximum dew point. Atmosphere must be non-condensing at all times. |
| Operating | 10% to 80% relative humidity with 29°C (84.2°F) maximum dew point. |
| Maximum vibration | Specifications |
|---|---|
| Operating | 0.26 G rms at 5 Hz to 350 Hz (all operation orientations). |
| Storage | 1.88 G rms at 10 Hz to 500 Hz for 15 min (all six sides tested). |
| Maximum vibration | Specifications |
|---|---|
| Operating | Six consecutively executed shock pulses in the positive and negative x, y, and z axes of 40 G for up to 2.3 ms. |
| Storage | Six consecutively executed shock pulses in the positive and negative x, y, and z axes (one pulse on each side of the system) of 71 G for up to 2 ms. |
| Maximum altitude | Specifications |
|---|---|
| Operating |
3048 m (10,000 ft) |
| Storage | 12,000 m (39,370 ft) |
| Operating temperature de-rating | Specifications |
|---|---|
| Up to 35°C (95°F) | Maximum temperature is reduced by 1°C/300 m (1°F/547 ft) above 950 m (3,117 ft). |
| 35°C to 40°C (95°F to 104°F) | Maximum temperature is reduced by 1°C/175 m (1°F/319 ft) above 950 m (3,117 ft). |
| 40°C to 45°C (104°F to 113°F) | Maximum temperature is reduced by 1°C/125 m (1°F/228 ft) above 950 m (3,117 ft). |
Particulate and gaseous contamination specifications
| Particulate contamination | Specifications |
|---|---|
| Air filtration | Data center air filtration as defined by ISO Class
8 per ISO 14644-1 with a 95% upper confidence limit.
|
| Conductive dust | Air must be free of conductive dust, zinc whiskers,
or other conductive particles.
|
| Corrosive dust |
|
| Gaseous contamination | Specifications |
|---|---|
| Copper coupon corrosion rate | <300 Å/month per Class G1 as defined by ANSI/ISA71.04-1985. |
| Silver coupon corrosion rate | <200 Å/month as defined by AHSRAE TC9.9. |
- NOTE: Maximum corrosive contaminant levels measured at ≤50% relative humidity.
Standard operating temperature
| Standard operating temperature | Specifications |
|---|---|
| Continuous operation (for altitude less than 950 m or 3117 ft) | 10°C to 35°C (50°F to 95°F) with no direct sunlight
on the equipment.
|
Expanded operating temperature
| Expanded operating temperature | Specifications |
|---|---|
| Continuous operation | 5°C to 40°C at 5% to 85% RH with 29°C dew point.
For temperatures between 35°C and 40°C, de-rate maximum allowable temperature by 1°C per 175 m above 950 m (1°F per 319 ft). |
| ≤ 1% of annual operating hours | –5°C to 45°C at 5% to 90% RH with 29°C dew point.
For temperatures between 40°C and 45°C, de-rate maximum allowable temperature by 1°C per 125 m above 950 m (1°F per 228 ft). |
- NOTE: When operating in the expanded temperature range, system performance may be impacted.
- NOTE: When operating in the expanded temperature range, ambient temperature warnings maybe reported in the System Event Log.
Expanded operating temperature restrictions
- Do not perform a cold startup below 5°C.
- The operating temperature specified is for a maximum altitude of 3050 m (10,000 ft).
- 160 W or higher wattage processor is not supported.
- Redundant power supply units are required.
- Non-Dell qualified peripheral cards and/or peripheral cards greater than 25 W are not supported.
- The 3.5-inch hard drive chassis supports a maximum of 120 W processor.
- The 2.5-inch hard drive chassis supports a maximum of 145 W processor.
- Only SSDs are allowed in the hard drive slots at the back of the 3.5-inch hard drive chassis.
- Mid drive configurations, eight 3.5-inch and eighteen 1.8-inch SSD configurations are not supported.
- GPU is not supported
- Tape backup unit (TBU) is not supported.