Dell DL1300 Appliance: руководство по обслуживанию

Dimensions and weight

Physical Dimensions
Height 42.8 mm (1.68 inch)
Width with rack latches 482.38 mm (19 inch)
Width without rack latches 434.15 mm (17.09 inch)
Depth without bezel 497 mm (19.5 inch)
Maximum weight for four 3.5-inch hot swappable hard drive chassis 9.51 kg (20.96 lb)
Empty weight for four 3.5-inch hot swappable hard drive chassis 5.25 kg (11.57 lb)

Processor specifications

Processor Specification
Type One Intel Xeon E3 series processor

Expansion bus specifications

PCI Express Generation 3 expansion slots using expansion card riser Specification
PCIE_G3_X16 (Slot 1) one half-height, half-length x16 link for processor 1
(Slot 2) one full-height, half-length x16 link for processor 1
PCIE_G3_X8 (Slot 1) one full-height, half-length x4 link for processor 1
(Slot 2) one half-height, half-length x8 link for processor 1

Memory specifications

Memory Specification
Architecture DDR3 UDIMMs that operates at 2133 MT/s.
Support for advanced ECC or memory optimized operation
Memory module sockets Four 288-pin sockets
Memory module capacities (UDIMM) 4 GB (single-rank), 8 GB (dual-rank), 16 GB (dual-rank)
Minimum RAM 16 GB
Maximum RAM 64 GB
  • NOTE: For system specific memory details, see Supported configurations section.
Related reference

Power specifications

Power supply unit Specification
Power rating per power supply unit (PSU) 250 W (Bronze) AC (100–240 V, 50/60 Hz, 4.0 A-2.0 A)
Heat dissipation
  • NOTE: Heat dissipation is calculated using the PSU wattage rating.
1039 BTU/hr maximum (250 W PSU)
Voltage
  • NOTE: This system is also designed to be connected to IT power systems with a phase-to-phase voltage not exceeding 230 V.
100–240 V AC, autoranging, 50/60 Hz

Storage controller specifications

Storage controller Specification
Storage controller type PERC H330
  • NOTE: Only the DL1300 4 TB+2VM system supports PERC H830 RAID controller.

Drive specifications

Drives Specification
Four hard drive systems Four 3.5-inch hot swappable Nearline SAS hard drives

Connectors specifications

Back connectors Specification
NIC Two 10/100/1000 Mbps
Serial 9-pin, DTE, 16550-compatible
USB Two 9-pin, USB 3.0-compliant
Video 15-pin VGA
iDRAC8 One optional 1 GbE Ethernet
Front connectors Specification
USB Two 4-pin, USB 2.0-compliant
Video 15-pin VGA
Internal connectors Specification
USB One 9-pin, USB 3.0-compliant

Video specifications

Video Specification
Video type Integrated Matrox G200
Video memory 16 MB shared

Environmental specifications

  • NOTE: For additional information about environmental measurements for specific system configurations, see Dell.com/environmental_datasheets.
Table 1. Temperature specifications
Temperature Specifications
Storage –40°C to 65°C (–40°F to 149°F)
Continuous operation (for altitude less than 950 m or 3117 ft) 10°C to 35°C (50°F to 95°F) with no direct sunlight on the equipment.
For information about fresh air, see Expanded Operating Temperature section.
Maximum temperature gradient (operating and storage) 20°C/h (36°F/h)
Table 2. Relative humidity specifications
Relative humidity Specifications
Storage 5% to 95% RH with 33°C (91°F) maximum dew point. Atmosphere must be non-condensing at all times.
Operating 10% to 80% relative humidity with 29°C (84.2°F) maximum dew point.
Table 3. Maximum vibration specifications
Maximum vibration Specifications
Operating 0.26 G rms at 5 Hz to 350 Hz (all operation orientations).
Storage 1.88 G rms at 10 Hz to 500 Hz for 15 min (all six sides tested).
Table 4. Maximum shock specifications
Maximum shock Specifications
Operating Six consecutively executed shock pulses in the positive and negative x, y, and z axes of 40 G for up to 2.3 ms.
Storage Six consecutively executed shock pulses in the positive and negative x, y, and z axes (one pulse on each side of the system) of 71 G for up to 2 ms.
Table 5. Maximum altitude specifications
Maximum altitude Specifications
Operating

3048 m (10,000 ft)

Storage 12,000 m (39,370 ft)
Table 6. Operating temperature de-rating specifications
Operating temperature de-rating Specifications
Up to 35°C (95°F) Maximum temperature is reduced by 1°C/300 m (1°F/547 ft) above 950 m (3,117 ft).

Particulate and gaseous contamination specifications

The following table defines the limitations that help avoid any equipment damage or failure from particulates and gaseous contamination. If the levels of particulates or gaseous pollution exceed the specified limitations and result in equipment damage or failure, you may need to rectify the environmental conditions. Re-mediation of environmental conditions is the responsibility of the customer.
Table 1. Particulate contamination specifications
Particulate contamination Specifications
Air filtration Data center air filtration as defined by ISO Class 8 per ISO 14644-1 with a 95% upper confidence limit.
  • NOTE: This condition applies only to data center environments. Air filtration requirements do not apply to IT equipment designed to be used outside a data center, in environments such as an office or factory floor.
  • NOTE: Air entering the data center must have MERV11 or MERV13 filtration.
Conductive dust Air must be free of conductive dust, zinc whiskers, or other conductive particles.
  • NOTE: This condition applies to data center and non-data center environments.
Corrosive dust
  • Air must be free of corrosive dust.
  • Residual dust present in the air must have a deliquescent point less than 60% relative humidity.
  • NOTE: This condition applies to data center and non-data center environments.
Table 2. Gaseous contamination specifications
Gaseous contamination Specifications
Copper coupon corrosion rate <300 Å/month per Class G1 as defined by ANSI/ISA71.04-1985.
Silver coupon corrosion rate <200 Å/month as defined by AHSRAE TC9.9.
  • NOTE: Maximum corrosive contaminant levels measured at ≤50% relative humidity.