Chassis dimensions

| Xa | Xb | Y | Za | Zb | Zc |
|---|---|---|---|---|---|
| 482.0 mm (18.97 inches) | 434.0 mm (17.08 inches) | 86.8 mm (3.41 inches) | 22.0 mm (0.86 inches) Without bezel
35.84 mm (1.41 inches) With bezel | 677.44 mm (26.67 inches) Ear to L bracket housing
650.24 mm (25.6 inches) Ear to PSU surface | 685.78 mm (26.99 inches) Ear to PSU handle without velcro strap |
System weight
| System configuration | Maximum weight (with all drives/SSDs/bezel) |
|---|---|
| 16+8 x 2.5-inch | 25.92 kg (57.14 lb) |
| 12 x 3.5-inch | 28.82 kg (63.53 lb) |
| 8 x 3.5-inch | 25.84 kg (54.96 lb) |
| 8 x 2.5-inch | 21.56 kg (47.53 lb) |
| No backplane configuration | 19.40 kg (42.76 lb) |
Processor specifications
| Supported processor | Number of processors supported |
|---|---|
| 5th Generation Intel Xeon Scalable processors with up to 32 cores | Up to two |
| and 4th Generation Intel Xeon Scalable processors with up to 32 cores |
PSU specifications
The PowerEdgeHS5620system supports up to two AC or DC power supply units (PSUs).
| PSU | Class | Heat dissipation (maximum) (BTU/hr) | Frequency (Hz) | AC Voltage | DC Voltage | Current (A) | ||||
|---|---|---|---|---|---|---|---|---|---|---|
| 100–120 V | 200–240 V | 277 V | 240 V | 336 V | - (48 V — 60 V) | |||||
| 700 W mixed mode HLAC | Titanium | 2625 | 50/60 | N/A | 700 W | N/A | N/A | N/A | N/A | 4.1 A |
| N/A | N/A | N/A | N/A | N/A | 700 W | N/A | N/A | 3.4 A | ||
| 800 W mixed mode | Platinum | 3000 | 50/60 | 800 W | 800 W | N/A | N/A | N/A | N/A | 9.2 A - 4.7 A |
| N/A | N/A | N/A | N/A | N/A | 800 W | N/A | N/A | 3.8 A | ||
| 1100 W -48 V DC | N/A | 4265 | N/A | N/A | N/A | N/A | N/A | N/A | 1100 W | 27 A |
| 1100 W mixed mode | Titanium | 4125 | 50/60 | 1050 W | 1100 W | N/A | N/A | N/A | N/A | 12 A - 6.3 A |
| N/A | N/A | N/A | N/A | N/A | 1100 W | N/A | N/A | 5.2 A | ||
| 1400 W mixed mode | Titanium | 5250 | 50/60 | 1050 W | 1400 W | N/A | N/A | N/A | N/A | 12 A - 8 A |
| N/A | N/A | N/A | N/A | N/A | 1400 W | N/A | N/A | 6.5 A | ||
| 1400 W mixed mode | Platinum | 5250 | 50/60 | 1050 W | 1400 W | N/A | N/A | N/A | N/A | 12 A - 8 A |
| N/A | N/A | N/A | N/A | N/A | 1400 W | N/A | N/A | 6.6 A | ||
| 1400 W 277 V AC and HVDC | Titanium | 5250 | 50/60 | N/A | N/A | 1400 W | N/A | N/A | N/A | 5.8 A |
| 5250 | N/A | N/A | N/A | N/A | N/A | 1400 W | N/A | 5.17 A | ||
| 1800 W mixed mode HLAC | Titanium | 6610 | 50/60 | N/A | 1800 W | N/A | N/A | N/A | N/A | 10 A |
| N/A | N/A | N/A | N/A | N/A | 1800 W | N/A | N/A | 8.2 A | ||



| Form factor | Output | Power cord |
|---|---|---|
| Redundant 60 mm | 700 W Mixed Mode HLAC | C13 |
| 800 W Mixed Mode | C13 | |
| 1100 W Mixed Mode | C13 | |
| 1100 W -48 V DC | Lotes DC PSU connector | |
| 1400 W Mixed Mode | C13 | |
| 1400 W 277 VAC and 336 VDC | APP 2006G1 | |
| 1800 W Mixed Mode HLAC | C15 |
Supported operating systems
The PowerEdge HS5620 system supports the following operating systems:
- Canonical Ubuntu Server LTS
- Microsoft Windows Server with Hyper-V
- Red Hat Enterprise Linux
- SUSE Linux Enterprise Server
- VMware vSAN/ESXi
For more information, go to Operating System Manuals.
Cooling fan specifications
Cooling fan specifications
The PowerEdgeHS5620 system supports up to six Standard (STD) fans , High performance (HPR) gold fans , or Very high performance fans.
| Fan type | Abbreviation | Also known as | Label color | Label image |
|---|---|---|---|---|
| Standard fan | STD | STD | No label | |
| High-performance fan (Silver grade) fan | HPR SLVR | HPR | Silver | NOTE:New cooling fans come with the High-Performance Silver Grade label. While the older cooling fans have the High-Performance label.
![]() ![]() |
| High-performance fan (Gold grade) fan | HPR GOLD | VHPR - Very High Performance | Gold | NOTE:New cooling fans come with the High-Performance Gold Grade label. While the older cooling fans have the High-Performance label.
![]() ![]() |
System battery specifications
The PowerEdge HS5620 system uses one CR 2032 3.0-V lithium coin cell battery.
Expansion card riser specifications
| Slot no | Card support | CPU1 | CPU2 | |||
|---|---|---|---|---|---|---|
| R1C | R1D | Integrated | Integrated | R1C | ||
| PCIe Slot-1 | SW-HL-LP | N/A | N/A | x16 | N/A | N/A |
| PCIe Slot-2 | SW-HL-LP | N/A | N/A | x8 | N/A | N/A |
| PCIe Slot-3 | SW-HL-LP | x16 (Gen5) | x8 (Gen5) | N/A | N/A | N/A |
| PCIe Slot-4 | SW-HL-LP | N/A | x8 (Gen5) | N/A | N/A | x16 (Gen5) |
| PCIe Slot-5 | SW-HL-LP | N/A | N/A | N/A | x16 | N/A |
| PCIe Slot-6 | SW-HL-LP | N/A | N/A | N/A | x16 | N/A |
| Label | Description |
|---|---|
| SW | Single Width |
| DW | Double Wide (Xilinx FPGA accelerator) |
| FH | Full height |
| HL | Half length |
Memory specifications
| DIMM type | DIMM rank | DIMM capacity | Single processor | Dual processors | ||
|---|---|---|---|---|---|---|
| Minimum memory capacity | Maximum memory capacity | Minimum memory capacity | Maximum memory capacity | |||
| RDIMM | Single rank | 16 GB | 16 GB | 128 GB | 32 GB | 256 GB |
| Dual rank | 32 GB | 32 GB | 256 GB | 64 GB | 512 GB | |
| 64 GB | 64 GB | 512 GB | 128 GB | 1 TB | ||
| Quad rank | 128 GB | 128 GB | 1 TB | 256 GB | 2 TB | |
| Memory module sockets | Speed |
|---|---|
| 16, 288-pin | 4000 MT/s, 4400 MT/s, 4800 MT/s |
| DIMM type | DIMM rank | DIMM capacity | Single processor | Dual processors | ||
|---|---|---|---|---|---|---|
| Minimum memory capacity | Maximum memory capacity | Minimum memory capacity | Maximum memory capacity | |||
| RDIMM | Single rank | 16 GB | 16 GB | 128 GB | 32 GB | 256 GB |
| Dual rank | 32 GB | 32 GB | 256 GB | 64 GB | 512 GB | |
| 64 GB | 64 GB | 512 GB | 128 GB | 1 TB | ||
| 96 GB | 96 GB | 768 GB | 192 GB | 1.5 TB | ||
| Quad rank | 128 GB | 128 GB | 1 TB | 256 GB | 2 TB | |
| Memory module sockets | Speed |
|---|---|
| 16, 288-pin | 4000 MT/s, 4400 MT/s, 4800 MT/s, 5200 MT/s, 5600 MT/s |
Storage controller specifications
| Supported storage controller cards | |
|---|---|
Internal controllers
|
|
External controllers
|
|
Internal Boot
|
|
Software RAID
|
Drives
- 8 x 3.5-inch SAS/SATA drives
- 12 x 3.5-inch SAS/SATA drives
- 8 x 2.5-inch SAS/SATA (HDD/SSD) drives
- 8 x 2.5-inch NVMe drives
- 16 x 2.5-inch SAS/SATA (HDD/SSD) drives + 8 x 2.5-inch NVMe drives
USB ports specifications
| Front | Rear | Internal (Optional) | |||
|---|---|---|---|---|---|
| USB port type | No. of ports | USB port type | No. of ports | USB port type | No. of ports |
| USB 2.0-compliant port | One | USB 2.0-compliant port | One | Internal USB 3.0-compliant port | One |
| iDRAC Direct port (Micro-AB USB 2.0- compliant port) | One | USB 3.0-compliant port | One | ||
Serial connector specifications
The PowerEdge HS5620 system supports one serial port on the system board, which is Data Terminal Equipment (DTE), 16550-compliant .
The serial connector is installed as default on the system board.
NIC port specifications
| Feature | Specifications |
|---|---|
| LOM | 1 GB x 2 |
| OCP card (OCP 3.0) (optional) | 1 GbE x 4, 10 GbE x 2, 10 GbE x 4, 25 GbE x 2, 25 GbE x 4 |
VGA ports specifications
The PowerEdge HS5620 system supports two DB-15 VGA ports, one each on the front and rear panels of the system.
Video specifications
| Resolution | Refresh rate (Hz) | Color depth (bits) |
|---|---|---|
| 1024 x 768 | 60 | 8, 16, 32 |
| 1280 x 800 | 60 | 8, 16, 32 |
| 1280 x 1024 | 60 | 8, 16, 32 |
| 1360 x 768 | 60 | 8, 16, 32 |
| 1440 x 900 | 60 | 8, 16, 32 |
| 1600 x 900 | 60 | 8, 16, 32 |
| 1600 x 1200 | 60 | 8, 16, 32 |
| 1680 x 1050 | 60 | 8, 16, 32 |
| 1920 x 1080 | 60 | 8, 16, 32 |
| 1920 x 1200 | 60 | 8, 16, 32 |
Environmental specifications
| Temperature, humidity and, operational altitude | Allowable continuous operations |
|---|---|
| Temperature range for altitudes <= 900 m (<= 2953 ft) | 10–35°C (50–95°F) with no direct sunlight on the equipment |
| Humidity percent range (non-condensing at all times) | 8% RH with -12°C (10.4°F) minimum dew point to 80% RH with 21°C (69.8°F) maximum dew point |
| Operational altitude derating | Maximum temperature is reduced by 1°C/300 m (1.8°F/984 Ft) above 900 m (2953 Ft) |
| Temperature, humidity and, operational altitude | Allowable continuous operations |
|---|---|
| Temperature range for altitudes <= 900 m (<= 2953 ft) | 5–40°C (41–104°F) with no direct sunlight on the equipment |
| Humidity percent range (non-condensing at all times) | 8% RH with -12°C (10.4°F) minimum dew point to 85% RH with 24°C (75.2°F) maximum dew point |
| Operational altitude derating | Maximum temperature is reduced by 1°C/175 m (1.8°F/574 Ft) above 900 m (2953 Ft) |
| Temperature, humidity and, operational altitude | Allowable continuous operations |
|---|---|
| Temperature range for altitudes <= 900 m (<= 2953 ft) | 5–45°C (41–113°F) with no direct sunlight on the equipment |
| Humidity percent range (non-condensing at all times) | 8% RH with -12°C (10.4°F) minimum dew point to 90% RH with 24°C (75.2°F) maximum dew point |
| Operational altitude derating | Maximum temperature is reduced by 1°C/125 m (1.8°F/410 Ft) above 900 m (2953 Ft) |
| Temperature, humidity and, operational altitude | Allowable continuous operations |
|---|---|
| Temperature range for altitudes <= 900 m (<= 2953 ft) | 5–45°C (41–113°F) with no direct sunlight on the equipment |
| Humidity percent range (non-condensing at all times) | 8% RH with -12°C (10.4°F) minimum dew point to 90% RH with 24°C (75.2°F) maximum dew point |
| Operational altitude derating | Maximum temperature is reduced by 1°C/125 m (1.8°F/410 Ft) above 900 m (2953 Ft) |
| Temperature, humidity and, operational altitude | Allowable continuous operations |
|---|---|
| Maximum temperature gradient (applies to both operation and non-operation) | 20°C in an hour* (36°F in an hour) and 5°C in 15 minutes (9°F in 15 minutes), 5°C in an hour* (9°F in an hour) for tape
NOTE:* - Per ASHRAE thermal guidelines for tape hardware, these are not instantaneous rates of temperature change.
|
| Non-operational temperature limits | -40°C to 65°C (-104°F to 149°F) |
| Non-operational humidity limits | 5% to 95% RH with 27°C (80.6°F) maximum dew point |
| Maximum non-operational altitude | 12,000 meters (39,370 feet) |
| Maximum operational altitude | 3,048 meters (10,000 feet) |
| Maximum vibration | Specifications |
|---|---|
| Operating | 0.21 Grms at 5 Hz to 500 Hz for 10 minutes (all operation orientations) |
| Storage | 1.88 Grms at 10 Hz to 500 Hz for 15 minutes (all six sides tested) |
| Maximum shock pulse | Specifications |
|---|---|
| Operating | Six consecutively performed shock pulses in the positive and negative x, y, and z axis of 6 G for up to 11 ms. |
| Storage | Six consecutively performed shock pulses in the positive and negative x, y, and z axis (one pulse on each side of the system) of 71 G for up to 2 ms. |
| Particulate contamination | Specifications |
|---|---|
| Air filtration | Data center air filtration as defined by ISO Class 8 per ISO 14644-1 with a 95% upper confidence limit.
NOTE:The ISO Class 8 condition applies to data center environments only. This air filtration requirement does not apply to IT equipment designed to be used outside a data center, in environments such as an office or factory floor.
NOTE: Air entering the data center must have MERV11 or MERV13 filtration.
|
| Conductive dust | Air must be free of conductive dust zinc whiskers, or other conductive particles.
NOTE: This condition applies to data center and non-data center environments.
|
| Corrosive dust |
Air must be free of corrosive dust. Residual dust present in the air must have a deliquescent point less than 60% relative humidity. NOTE:This condition applies to data center and non-data center environments.
|
| Gaseous contamination | Specification |
|---|---|
| Copper coupon corrosion rate | <300A/month per class G1 as defines by ANSI/ISA71.04-2013 |
| Silver coupon corrosion rate | <200A/month as defined by ANSI/ISA71.04-2013 |
Thermal restriction matrix
| Heat sink | Processor TDP |
|---|---|
| STD HSK | < 185 W CPU SKUs |
| HPR HSK | 185 W-250 W CPU SKUs (12 x 3.5-inch drive configuration not supported) |
| 125W-250W CPU SKUs (12 x 3.5-inch drive configuration supported) |
| Label | Description |
|---|---|
| STD | Standard |
| HPR (Silver) | High Performance Silver (HPR) fan |
| HPR (Gold) | High Performance Gold (VHP) fan |
| HSK | Heat sink |
| HS5620 | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| configuration | No backplane | 8 x 3.5-inch SAS configuration | 12 x 3.5-inch SAS configuration | 12 x 3.5-inch configuration with rear drive module | 8 x 2.5-inch SAS configuration | 8 x 2.5-inch NVMe configuration | 16 x 2.5-inch SAS configuration | 16 x 2.5-inch + 8 x 2.5-inch NVMe configuration | ||
| EMR MCC CPU | 4514Y | 150 W | 45°C | 40°C | 35°C | 35°C | 40°C | 40°C | 40°C | 40°C |
| 5512U | 185 W | 45°C | 40°C | 35°C | 35°C | 40°C | 40°C | 40°C | 40°C | |
| 6526Y/6534 | 195 W | 35°C | 35°C | 35°C | 35°C | 35°C | 35°C | 35°C | 35°C | |
| 6548+/6542Y/6548N | 250 W | 35°C | 35°C | 30°C | 30°C | 35°C | 35°C | 35°C | 35°C | |
| SPR LCC CPU | 4509Y | 125W | 45°C | 40°C | 35°C | 35°C | 40°C | 40°C | 40°C | 40°C |
| 4510 | 150 W | 45°C | 40°C | 35°C | 35°C | 40°C | 40°C | 40°C | 40°C | |
| SPR MCC CPU | 3408U | 125 W | 45°C | 40°C | 35°C | 35°C | 40°C | 40°C | 40°C | 40°C |
| 4410Y/5415+ | 150 W | 45°C | 40°C | 35°C | 35°C | 40°C | 40°C | 40°C | 40°C | |
| 4416+ | 165 W | 45°C | 40°C | 35°C | 35°C | 40°C | 40°C | 40°C | 40°C | |
| 5418Y/5412U/6426Y | 185 W | 45°C | 40°C | 35°C | 35°C | 40°C | 40°C | 40°C | 40°C | |
| 6438M/5420+/6434/6438Y+ | 205 W | 35°C | 35°C | 35°C | 35°C | 35°C | 35°C | 35°C | 35°C | |
| 6448Y/6442Y | 225 W | 35°C | 35°C | 35°C | 35°C | 35°C | 35°C | 35°C | 35°C | |
| 6414U/6444Y 11 | 250 W | 35°C | 35°C | 30°C | 30°C | 35°C | 35°C | 35°C | 35°C | |
| Memory | 128 GB RDIMM 5200 | 9 W, 1DPC | 35°C | 35°C | 30°C | 30°C | 35°C | 35°C | 35°C | 35°C |
| 96 GB RDIMM 5200 | 8.1 W, 1DPC | 35°C | 35°C | 30°C | 30°C | 35°C | 35°C | 35°C | 35°C | |
| 64 GB RDIMM 5200 | 7.7 W, 1DPC | 45°C | 40°C | 35°C | 35°C | 40°C | 40°C | 40°C | 40°C | |
| 32 GB RDIMM 5200 | 5.1 W, 1DPC | 45°C | 40°C | 35°C | 35°C | 40°C | 40°C | 40°C | 40°C | |
| 128 GB RDIMM 4800 | 14.2 W, 1DPC | 35°C | 35°C | 30°C | 30°C | 35°C | 35°C | 35°C | 35°C | |
| 64 GB RDIMM 4800 | 12 W, 1DPC | 45°C | 40°C | 35°C | 35°C | 40°C | 40°C | 40°C | 40°C | |
| 32 GB RDIMM 4800 | 10 W, 1DPC | 45°C | 40°C | 35°C | 35°C | 40°C | 40°C | 40°C | 40°C | |
| PCIe | 45°C | 40°C | 35°C1 | 35°C1 | 40°C | 40°C | 40°C | 40°C | ||
| A2 GPU6 | 35°C | 30°C | Not supported | Not supported | 35°C | 35°C | 30°C | 30°C | ||
| OCP | 45°C | 40°C | 35°C2 | 35°C2 | 40°C | 40°C | 40°C | 40°C | ||
| BOSS | 35°C | 35°C | 35°C | 35°C | 35°C | 35°C | 35°C | 35°C | ||
- Max supported thermal tier of PCIe card is Tier 5.
- Max supported thermal tier of OCP is Tier 5.
- HPR Sliver fan is required from fan zone 2 to fan zone 6 for 8 x 2.5-inch NVMe, 16 x 2.5-inch SAS/SATA + 8 x 2.5-inch NVMe, 12 x 3.5-inch drives or GPU configurations.
- Optional fan zone 1 has to be populated with HPR Gold fan is for BOSS, GPU or rear drive module populations.
- PCIe slot priority of Nvidia A2 GPU is constrained on slot #3, #4, #6.
- HPR heatsink is required for ≥ 185 W CPUs, 12 x 3.5-inch drives or 12 x 3.5-inch drives with rear storage module configurations.
- DIMM blank is required for 12 x 3.5-inch SAS/SATA with rear storage module.
- Fan blank is required on fan zone 1 when no fan population.
- OCP shroud is required for OCP card population without PCIe riser module installed.
- CPU blank is required for single processor configuration.
- Due to HW limitation, 6444Y is clamped to 250 W.
- Rear drive module does not support Kioxia CM6 series, Samsung PM1735 series, Hynix PE8010/PE8110 ≥ 7.68 TB, Samsung PM1733a > 1.92 TB, Samsung PM1735a > 1.6 TB and Redtail NVMe drive.
| HS5620 | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| configuration | No backplane | 8 x 3.5-inch SAS configuration | 12 x 3.5-inch SAS configuration | 12 x 3.5-inch configuration with rear drive module | 8 x 2.5-inch SAS configuration | 8 x 2.5-inch NVMe configuration | 16 x 2.5-inch SAS configuration | 24 x 2.5-inch (16 x 2.5-inch + 8 x 2.5-inch NVMe configuration) | ||
| SPR MCC CPU | 3408U | 125 W | 35°C | 35°C | 35°C | 35°C | 35°C | 35°C | 35°C | 35°C |
| 4410Y/5415+ | 150 W | 35°C | 35°C | 35°C | 35°C | 35°C | 35°C | 35°C | 35°C | |
| 4416+ | 165 W | 35°C | 35°C | Not Supported | Not Supported | 35°C | 35°C | 35°C | 35°C | |
| 5418Y/5412U/6426Y | 185 W | 35°C | 35°C | Not Supported | Not Supported | 35°C | 35°C | 35°C | 35°C | |
| 6438M/5420+/6434/6438Y+ | 205 W | 35°C | Not Supported | Not Supported | Not Supported | 35°C | 35°C | 35°C | 35°C | |
| 6448Y/6442Y | 225 W | 35°C | Not Supported | Not Supported | Not Supported | 35°C | 35°C | Not Supported | 35°C | |
| 6414U / 6444Y 15 | 250 W | 35°C | Not Supported | Not Supported | Not Supported | Not Supported | 35°C | Not Supported | Not Supported | |
| Memory | 128 GB RDIMM 4800 | 14.2 W, 1DPC | 35°C | Not Supported | Not Supported | Not Supported | Not Supported | 35°C | Not Supported | Not Supported |
| 64 GB RDIMM 4800 | 12 W, 1DPC | 35°C | 35°C | Not Supported | Not Supported | 35°C | 35°C | 35°C | 35°C | |
| 32 GB RDIMM 4800 | 10 W, 1DPC | 35°C | 35°C | 35°C | 35°C | 35°C | 35°C | 35°C | 35°C | |
| PCIe | 35°C | 35°C 2 | 35°C 1 | 35°C 1 | 35°C 2 | 35°C | 35°C 2 | 35°C 2 | ||
| A2 GPU6 | 35°C | Not Supported | Not Supported | Not Supported | 35°C | 35°C | Not Supported | Not Supported | ||
| OCP | 35°C | 35°C 4 | 35°C 3 | 35°C 3 | 35°C 4 | 35°C | 35°C 4 | 35°C 4 | ||
| BOSS | 35°C | 35°C | 35°C 3 | 35°C 3 | 35°C | 35°C | 35°C | 35°C | ||
- Max supported thermal tier of PCIe card is Tier 3.
- Max supported thermal tier of OCP is Tier 5.
- Max supported thermal tier of OCP is Tier 2.
- Max supported thermal tier of OCP is Tier 5.
- ≥ 960 GB M.2 SSDs are not supported in 12 x 3.5-inch drive configuration.
- Only support the optical transceiver with thermal spec. 85°C for network adapter and OCP card.
- PERC adapter with BBU is not supported in 3.5-inch drive configurations.
- Six fans population is required and fan zone 1 is dedicated to install HPR Gold fan.
- HPR Silver fan on fan zone 2 to fan zone 6 is required for front NVMe drives population or 12 x 3.5-inch drive configuration.
- HPR Silver fan on fan zone 2 to fan zone 6 is required for GPU population and PCIe slot priority of Nvidia A2 GPU is constrained on slot #3, #4, #6.
- HPR heatsink is required for ≥ 185 W CPUs or 12 x 3.5-inch SAS/SATA or 12 x 3.5-inch SAS/SATA with rear storage modules.
- DIMM blank is required for 12 x 3.5-inch SAS/SATA and 12 x 3.5-inch SAS/SATA with rear storage modules.
- OCP shroud is required for OCP card population without PCIe riser module installed.
- CPU blank is required for single processor configuration.
- Due to HW limitation, 6444Y is clamped to 250 W.
- Rear drive module does not support Kioxia CM6 series, Samsung PM1735 series, Hynix PE8010/PE8110 ≥ 7.68 TB, Samsung PM1733a > 1.92 TB, Samsung PM1735a > 1.6 TB and Redtail NVMe drive.
| configuration | No backplane | 8 x 3.5-inch SAS | 12 x 3.5-inch SAS | 8 x 2.5-inch SAS | 8 x 2.5-inch NVMe | 24 x 2.5-inch (16 x 2.5-inch + 8 x 2.5-inch NVMe) |
|---|---|---|---|---|---|---|
| Optional HW | ||||||
| Default | Fan 2 to Fan 6 with STD fan | Fan 2 to Fan 6 with STD fan | Fan 2 to Fan 6 with HPR Silver fan | Fan 2 to Fan 6 with STD fan | Fan 2 to Fan 6 with HPR Silver fan | Fan 2 to Fan 6 with HPR Silver fan |
| Rear Module | Not supported | Not supported |
Fan 1 with HPR Gold fan Fan 2 to Fan 6 with HPR Silver fan |
Not supported | Not supported | Not supported |
| BOSS N1 |
Fan 1 with HPR Gold fan Fan 2 to Fan 6 with STD fan |
Fan 1 with HPR Gold fan Fan 2 to Fan 6 with STD fan |
Fan 1 with HPR Gold fan Fan 2 to Fan 6 with HPR Silver fan |
Fan 1 with HPR Gold fan Fan 2 to Fan 6 with STD fan |
Fan 1 with HPR Gold fan Fan 2 to Fan 6 with HPR Silver fan |
Fan 1 with HPR Gold fan Fan 2 to Fan 6 with HPR Silver fan |
| GPU |
Fan 1 with HPR Gold fan Fan 2 to Fan 6 with HPR Silver fan |
Fan 1 with HPR Gold fan Fan 2 to Fan 6 with HPR Silver fan |
Fan 1 with HPR Gold fan Fan 2 to Fan 6 with HPR Silver fan |
Fan 1 with HPR Gold fan Fan 2 to Fan 6 with HPR Silver fan |
Fan 1 with HPR Gold fan Fan 2 to Fan 6 with HPR Silver fan |
Fan 1 with HPR Gold fan Fan 2 to Fan 6 with HPR Silver fan |
| configuration | No backplane | 8 x 3.5-inch SAS | 12 x 3.5-inch SAS | 8 x 2.5-inch SAS | 8 x 2.5-inch NVMe | 24 x 2.5-inch (16 x 2.5-inch + 8 x 2.5-inch NVMe) |
|---|---|---|---|---|---|---|
| Optional HW | ||||||
| Default |
Fan 1 with HPR Gold fan Fan 2 to Fan 6 with STD fan |
Fan 1 with HPR Gold fan Fan 2 to Fan 6 with STD fan |
Fan 1 with HPR Gold fan Fan 2 to Fan 6 with HPR Silver fan |
Fan 1 with HPR Gold fan Fan 2 to Fan 6 with STD fan |
Fan 1 with HPR Gold fan Fan 2 to Fan 6 with HPR Silver fan |
Fan 1 with HPR Gold fan Fan 2 to Fan 6 with HPR Silver fan |
| Rear Module | Not supported | Not supported |
Fan 1 with HPR Gold fan Fan 2 to Fan 6 with HPR Silver fan |
Not supported | Not supported | Not supported |
| BOSS N1 |
Fan 1 with HPR Gold fan Fan 2 to Fan 6 with STD fan |
Fan 1 with HPR Gold fan Fan 2 to Fan 6 with STD fan |
Fan 1 with HPR Gold fan Fan 2 to Fan 6 with HPR Silver fan |
Fan 1 with HPR Gold fan Fan 2 to Fan 6 with STD fan |
Fan 1 with HPR Gold fan Fan 2 to Fan 6 with HPR Silver fan |
Fan 1 with HPR Gold fan Fan 2 to Fan 6 with HPR Silver fan |
| GPU |
Fan 1 with HPR Gold fan Fan 2 to Fan 6 with HPR Silver fan |
Not supported |
Fan 1 with HPR Gold fan Fan 2 to Fan 6 with HPR Silver fan |
Fan 1 with HPR Gold fan Fan 2 to Fan 6 with HPR Silver fan |
Fan 1 with HPR Gold fan Fan 2 to Fan 6 with HPR Silver fan |
Not supported |
Thermal restrictions for PCIe adapter card and others with Open Server Manager (OSM)
- Cannot support PCIe adapter with the cooling requirement more than 200 LFM at 55C in a 3.5-inch drives configuration.
- Cannot support PCIe adapter with the cooling requirement more than 300 LFM at 55C in a 2.5-inch drives configuration.
- Cannot support OCP card with the cooling requirement more than 250 LFM at 55C in a 2.5-inch drives configuration.
- Only support the optical transceiver with higher temperature spec (≥ 85°C) (M14MK / N8TDR).
- The rear PERC adapter with BBU is not supported in 12 x 3.5-inch drive configuration.
Thermal Restrictions for PCIe adapter NIC and other network cards with iDRAC
- Cannot support PCIe cards with the cooling requirement more than 300LFM at 55C in a 12 x 3.5-inch SAS/SATA configuration.
- Solarflare Melrose DP 25 GBE SFP28 (TTKWY) not supported with 12 x 3.5-inch SAS/SATA configuration.
- 100 Gb network adapter or 100 Gb OCP is not supported in the 12 x 3.5-inch SAS/SATA configuration.
- Few 25 GB OCP cards with the cooling requirement more than 250LFM at 55C (3Y64D/4TRD3 / GGGDF/R1KTR / Y4VV5) is not supported in 12x3.5" SAS/SATA configuration.
- The 12 x 3.5-inch SAS/SATA configuration requires the optical transceiver with higher temperature spec (≥ 85°C) to support (M14MK / N8TDR).
- Quad port OCP (3Y64D/Y4VV5) requires the optical transceiver with higher temperature spec (≥ 85°C) to support (M14MK).
- 100 Gb network adapter cannot support the transceivers as 14NV5 / 9JKK2 / QSFP56 (MFS1S00-VxxxE/HxxxE).
- The h965e is limited to populate in PCI slot 3 in a 12 x 3.5-inch SAS/SATA configuration.
- Mellanox CX7 NDR200 card has few limitations of PCI slot locations.
Table 7. Mellanox CX7 NDR200 slot location limitationsThis table shows Mellanox CX7 NDR200 slot location limitations. Storage configuration Slots on 3.5-inch configuration Slots on 2.5-inch configuration Gen5 PCIe sloit support for CX7 NDR200 3, 4 3, 4 Gen4 PCIe sloit support for CX7 NDR200 6 5, 6
Thermal restrictions for extended ambient support (ASHRAE A3/A4)
- Two PSUs are required in redundant mode. Single PSU failure is not supported.
- 12 x 3.5-inch SAS/SATA configuration is not supported.
- BOSS(M.2) module is not supported.
- CPU TDP > 185 W is not supported.
- PCIe card TDP > 25 W is not supported.
- OCP cards with transmission rate higher than 25 GB is not supported.
- OCP transceiver spec ≤ 75°C is not supported.
- 8 x 3.5-inch SAS/SATA, 8 x 2.5-inch SAS/SATA, 8 x 2.5-inch NVMe, 16 x 2.5-inch SAS/SATA, 16 x 2.5-inch SAS/SATA + 8x 2.5-inch NVMe configurations are limited to support A3.
- .
- The rear drive is not supported.
Thermal air restrictions
| ASHRAE | A3/40°C (104°F) | A4/45°C (113°F) |
|---|---|---|
| PSU | Two PSUs are required in redundant mode. If there is PSU failure, system performance may be reduced. | |
| PCIe card | Non-Dell qualified peripheral cards and peripheral cards greater than 25 W are not supported. | |
| Processor | CPU TDP > 185W is not supported | |
| Front storage | 12 x 3.5-inch SAS/SATA config is not supported | 12 x 3.5-inch SAS/SATA configuration is not supported |
| 8 x 3.5-inch SAS/SATA, 8 x 2.5-inch SAS/SATA, 8 x 2.5-inch NVMe, 16 x 2.5-inch SAS/SATA, 16 x 2.5-inch SAS/SATA+ 8 x 2.5-inch NVMe configs are limited in A3 | 0 drive configuration is supported | |
| Rear storage | Not supported | |
| OCP | OCP card with transmission rate higher than 25G is not supported | |
| OCP transceiver spec ≤ 75C is not supported | ||
| BOSS | Not supported | |