Chassis dimensions

| Xa | Xb | Y | Za (with bezel) | Za (without bezel) | Zb | Zc |
|---|---|---|---|---|---|---|
| 482.3 mm | 448.0 mm | 86.8 mm | N/A | 41.4 mm | 762.1 mm | 795.9 mm |
Chassis weight
| System | Maximum weight (with all sleds and hard drives/SSDs) |
|---|---|
| PowerEdge C6300 enclosure and the PowerEdge C6320p sleds | 36.5 Kg (80.4 lb) |
Processor specifications
PSU specifications
Dell PowerEdge C6300 enclosure supports up to two AC or HVDC power supply units (PSUs). Dell PowerEdge C6320p does not support a mixed installation of 1400 W and 1600 W PSUs. The 1400 W and 1600 W PSUs are hot swappable and support hot swap in any condition if the system has the power throttling feature enabled.
| PSU | Heat dissipation (maximum) | Frequency | Voltage | Maximum input current | Maximum inrush current (peak) |
|---|---|---|---|---|---|
1400 W AC |
5220.763 BTU/hr | 50/60 Hz |
200-240 V AC |
9 A |
Initial inrush current cannot exceed 55 A (peak). Secondary inrush current cannot exceed 25 A (peak). |
1400 W HVDC (China only) |
– |
240 V DC |
9 A |
||
1600 W AC |
5966.586 BTU/hr | 50/60 Hz |
100-120 V AC 200-240 V AC |
12 A 10 A |
Initial inrush current and secondary inrush current cannot exceed 35 A (peak). |
1600 W HVDC |
– |
240 V DC |
10 A |
System battery specifications
Dell PowerEdge C6320p sled supports CR2032 3.0-V lithium coin cell battery.
Memory specifications
Dell PowerEdge C6320p system supports DDR4 registered DIMMs (RDIMMs) and Load Reduced DIMMS (LRDIMMS).
| Memory module sockets | Architecture | Memory capacity and ranking | Minimum RAM | Maximum RAM |
|---|---|---|---|---|
| Six 288-pin | 2400 MT/s DDR4 RDIMMs and LRDIMMS with support for memory optimized operation |
|
8 GB | Up to 384 GB |
Hard drives and storage specifications
The PowerEdge C6320p sled supports SAS, SATA, Solid State Drives (SSDs), and SDHC storage options.
| 2.5" hard drive per server node (6 Gbps SATA/SAS) | 6 |
| Internal 1.8" SSD (optional) for boot (120 GB or 240 GB) | 1 |
| SDHC Card (optional) for boot (up to 16 GB) | 1 |
Internal SD card slot
USB ports
The following table provides more information about the USB specifications:
| PowerEdge C6320p back panel |
|---|
One 9-pin, USB 3.0 compliant port One 4-pin, micro USB 2.0 compliant port NOTE: The micro USB port
should not be used for general USB purposes, it is reserved for use
as a serial port only. |
NIC ports
VGA ports
Video specifications
| Resolution | Refresh rate (Hz) | Color depth (bits) |
|---|---|---|
| 640 x 480 | 60, 70 | 8, 16, 32 |
| 800 x 600 | 60, 75, 85 | 8, 16, 32 |
| 1024 x 768 | 60, 75, 85 | 8, 16, 32 |
| 1152 x 864 | 60, 75, 85 | 8, 16, 32 |
| 1280 x 1024 | 60, 75 | 8, 16, 32 |
| 1440 x 900 | 60 | 8, 16, 32 |
Environmental specifications
| Temperature | Specifications |
|---|---|
| Storage | –40°C to 65°C (–40°F to 149°F) |
| Continuous operation (for altitude less than 950 m or 3117 ft) | 10°C to 35°C (50°F to 95°F) with no direct sunlight
on the equipment. NOTE: Certain system configurations may require
reductions in the upper temperature limits. |
| Maximum temperature gradient (operating and storage) | 20°C/h (36°F/h) |
| Relative humidity | Specifications |
|---|---|
| Storage | 5% to 95% (non-condensing) |
| Operating | 20% to 80% (non-condensing) with a maximum humidity gradation of 10% per hour. |
| Maximum vibration | Specifications |
|---|---|
| Operating | 0.26 Grms at 5 Hz–350 Hz (all operation orientations). |
| Storage | 1.88 Grms at 10 Hz–500 Hz for 15 min (all six sides tested). |
| Maximum shock | Specifications |
|---|---|
| Operating | One shock pulse in the positive z axis of 31 G for 2.6 ms in the operational orientation |
| Storage | Six consecutively executed shock pulses in the positive and negative x, y, and z axes (one pulse on each side of the system) of 27 G faired square wave pulse with velocity change at 235 inches per second (597 centimeters per second) |
| Maximum altitude | Specifications |
|---|---|
| Operating | -15.2 m–3,048 m (-50–10,000 ft.) |
| Storage | -15.2 m–10,668 m (-50–35,000 ft.) |
| Airborne contaminant level (Class) | G1 as defined by ISA-S71.04-1985 |
| Operating temperature de-rating | Specifications |
|---|---|
| Up to 35°C (95°F) | Maximum temperature is reduced by 1°C/300 m (1°F/547 ft) above 950 m (3,117 ft). |