Chassis dimensions

Figure 1. Chassis dimensions of PowerEdge C6300 enclosure
This figure shows the chassis dimensions of the PowerEdge C6300 enclosure.
Table 1. Dimensions of the Dell PowerEdge C6300 enclosureThe dimensions of the PowerEdge C6300 enclosure are as follows: Xa=482.3 mm, Xb=448 mm, Y=86.8 mm, Za (with bezel) =N/A, Za (without bezel) =41.4 mm, Zb=762.1 mm, and Zc=795.9 mm.
XaXbYZa (with bezel)Za (without bezel)ZbZc
482.3 mm448.0 mm86.8 mmN/A41.4 mm762.1 mm795.9 mm

Chassis weight

Table 1. Chassis weightFor PowerEdge C6300 enclosure and the PowerEdge C6320p sleds systems, the maximum chassis weight is 36.5 kg (80.4 lb).
System Maximum weight (with all sleds and hard drives/SSDs)
PowerEdge C6300 enclosure and the PowerEdge C6320p sleds 36.5 Kg (80.4 lb)

Processor specifications

The Dell PowerEdge C6320p supports an Intel Xeon Phi 72XXF or 72XX product family processor in four independent sleds.

PSU specifications

Dell PowerEdge C6300 enclosure supports up to two AC or HVDC power supply units (PSUs). Dell PowerEdge C6320p does not support a mixed installation of 1400 W and 1600 W PSUs. The 1400 W and 1600 W PSUs are hot swappable and support hot swap in any condition if the system has the power throttling feature enabled.

Table 1. PSU specifications For 1400 W AC PSUs, the maximum heat dissipation is 5220.763 BTU/hr, voltage is 200-240 V AC, and maximum input current is 9 A. Initial inrush current cannot exceed 55 A and secondary inrush current cannot exceed 25 A. For 1600 W AC and voltage of 100-120 V AC, heat dissipation is 5966.586 BTU/hr and maximum input current is 12 A. Initial inrush current and secondary inrush current cannot exceed 35 A. For 1600 W AC and voltage of 200-240 V AC, heat dissipation is 5966.586 BTU/hr and maximum input current is 10 A. For 1400 W HVDC, voltage is 240 V DC, maximum input current is 9 A, and maximum heat dissipation is 5220.763 BTU/hr. Initial inrush current cannot exceed 55 A and Secondary inrush current cannot exceed 25 A. For 1600 W HVDC, voltage is 240 V DC, maximum input current is 9 A, and maximum heat dissipation is 5966.586 BTU/hr. Initial inrush current cannot exceed 55 A and Secondary inrush current cannot exceed 25 A.
PSU Heat dissipation (maximum) Frequency Voltage Maximum input current Maximum inrush current (peak)

1400 W AC

5220.763 BTU/hr

50/60 Hz

200-240 V AC

9 A

Initial inrush current cannot exceed 55 A (peak).

Secondary inrush current cannot exceed 25 A (peak).

1400 W HVDC (China only)

240 V DC

9 A

1600 W AC

5966.586 BTU/hr

50/60 Hz

100-120 V AC

200-240 V AC

12 A

10 A

Initial inrush current and secondary inrush current cannot exceed 35 A (peak).

1600 W HVDC

240 V DC

10 A

System battery specifications

Dell PowerEdge C6320p sled supports CR2032 3.0-V lithium coin cell battery.

Memory specifications

Dell PowerEdge C6320p system supports DDR4 registered DIMMs (RDIMMs) and Load Reduced DIMMS (LRDIMMS).

Table 1. Memory specificationsYour system supports six memory module sockets of 288-pins each. The system supports 2400 MT/s DDR4 RDIMMs and LRDIMMS with support for advanced ECC or memory optimized operation. The supported memory capacity is 8 GB, 16 GB, 32 GB, and 64 GB dual-rank. Minimum RAM supported is 6 GB while the maximum RAM supported is 512 GB.
Memory module sockets Architecture Memory capacity and ranking Minimum RAM Maximum RAM
Six 288-pin 2400 MT/s DDR4 RDIMMs and LRDIMMS with support for memory optimized operation
  • Single rank - 8 GB
  • Dual rank - 16 GB
  • Dual rank - 32 GB
  • Quad rank - 64 GB
8 GB Up to 384 GB
NOTE: Memory modules of different speeds and capacities cannot be mixed.

Hard drives and storage specifications

The PowerEdge C6320p sled supports SAS, SATA, Solid State Drives (SSDs), and SDHC storage options.

NOTE: SAS hard drives are supported only if the LSI 2008 Mezzanine card is installed.
Table 1. Supported hard drive, SSD, and storage options for the PowerEdge C6320p sledThis table lists out the supported drive options for the PowerEdge C6320p system.
2.5" hard drive per server node (6 Gbps SATA/SAS) 6
Internal 1.8" SSD (optional) for boot (120 GB or 240 GB) 1
SDHC Card (optional) for boot (up to 16 GB) 1

Internal SD card slot

The PowerEdge C6320p sled supports a Micro Secure Digital (SD) card slot on the PCIe riser card.

USB ports

The PowerEdge C6320p sled supports one USB 3.0 compliant and one micro USB 2.0 compliant port on the back panel.

The following table provides more information about the USB specifications:

Table 1. USB specificationsThe PowerEdge C6320p system supports one 9-pin, USB 3.0 compliant port and one 4-pin, micro USB 2.0 compliant port on the back panel.
PowerEdge C6320p back panel

One 9-pin, USB 3.0 compliant port

One 4-pin, micro USB 2.0 compliant port

NOTE: The micro USB port should not be used for general USB purposes, it is reserved for use as a serial port only.

NIC ports

The PowerEdge C6320p sled supports one 10/100/1000 Mbps Network Interface Controller (NIC) port and Mellanox ConnectX-4 VPI EDR / 100 GbE Embedded Port (optional) on the back panel.

VGA ports

The Video Graphic Array (VGA) port enables you to connect the sled to a VGA display. The PowerEdge C6320p sled supports one 15-pin VGA port on each sled's back panel.

Video specifications

The PowerEdge C6320p sled supports a Matrox G200 graphics card with 16 MB RAM.
Table 1. Supported video resolution optionsFor 640 x 480 resolution, the refresh rate is 60 to 70 Hz and the color depth is 8, 16, 32 bit. For 800 x 600 resolution, the refresh rate is 60, 75, 85 Hz and color depth is 8, 16, 32 bit. For 1024 x 768 resolution, the refresh rate is 60, 75, 85 Hz and color depth is 8, 16, 32 bit. For 1152 x 864 resolution, the refresh rate is 60, 75, 85 Hz and color depth is 8, 16, 32 bit. For 1280 x 1024 resolution, the refresh rate is 60, 75 Hz and color depth is 8, 16, 32 bit. For 1440 x 900 resolution, the refresh rate is 60 Hz and color depth is 8, 16, 32 bit.
Resolution Refresh rate (Hz) Color depth (bits)
640 x 480 60, 70 8, 16, 32
800 x 600 60, 75, 85 8, 16, 32
1024 x 768 60, 75, 85 8, 16, 32
1152 x 864 60, 75, 85 8, 16, 32
1280 x 1024 60, 75 8, 16, 32
1440 x 900 60 8, 16, 32

Environmental specifications

NOTE: For additional information about environmental measurements for specific system configurations, see Dell.com/environmental_datasheets.
Table 1. Temperature specificationsWhen the system is in continuous operation (for altitude less than 950 m or 3117 ft), the temperature specification ranges from 10°C to 35°C (50°F to 95°F) with no direct sunlight on the equipment. NOTE: Maximum of 145 W 22 core processor is supported in systems with eight 2.5-inches drives, two PCI slot chassis, and 75 W single wide active GPU. When the system is not in operation, the temperature specification is –40°C to 65°C (–40°F to 149°F). The Maximum temperature gradient for both operation and non-operational systems is 20°C/h (36°F/h).
Temperature Specifications
Storage –40°C to 65°C (–40°F to 149°F)
Continuous operation (for altitude less than 950 m or 3117 ft) 10°C to 35°C (50°F to 95°F) with no direct sunlight on the equipment.
NOTE: Certain system configurations may require reductions in the upper temperature limits.
Maximum temperature gradient (operating and storage) 20°C/h (36°F/h)
Table 2. Relative humidity specificationsFor a non-operational system, the ambient relative humidity ranges from 5% to 95% with 33°C (91°F) maximum dew point. Atmosphere must be non-condensing at all times. For an operational system, the ambient relative humidity ranges from 10% to 80% with 29°C (84.2°F) maximum dew point.
Relative humidity Specifications
Storage 5% to 95% (non-condensing)
Operating 20% to 80% (non-condensing) with a maximum humidity gradation of 10% per hour.
Table 3. Maximum vibration specificationsThe maximum vibration specification of an operational system is 0.26 Grms at 5 Hz to 350 Hz (all operation orientations).The maximum vibration specification of a non-operational system is 1.88 Grms at 10 Hz to 500 Hz for 15 min (all six sides tested).
Maximum vibration Specifications
Operating 0.26 Grms at 5 Hz–350 Hz (all operation orientations).
Storage 1.88 Grms at 10 Hz–500 Hz for 15 min (all six sides tested).
Table 4. Maximum shock specificationsThe maximum shock specification of an operational system is six consecutively executed shock pulses in the positive and negative x, y, and z axes of 40 G for up to 2.3 ms. The maximum shock specification of a non-operational system is six consecutively executed shock pulses in the positive and negative x, y, and z axes (one pulse on each side of the system) of 71 G for up to 2 ms.
Maximum shock Specifications
Operating One shock pulse in the positive z axis of 31 G for 2.6 ms in the operational orientation
Storage

Six consecutively executed shock pulses in the positive and negative x, y, and z axes (one pulse on each side of the system) of 27 G faired square wave pulse with velocity change at 235 inches per second (597 centimeters per second)

Table 5. Maximum altitude specificationsThe maximum altitude specification for an operational system is 3048 m (10,000 ft). The maximum altitude specification for a non-operational system is 12,000 m (39,370 ft).
Maximum altitude Specifications
Operating -15.2 m–3,048 m (-50–10,000 ft.)
Storage -15.2 m–10,668 m (-50–35,000 ft.)
Table 6. Airborne contaminant level specification The airborne contaminant level is Class G1 as defined by ISA-S71.04-1985.
Airborne contaminant level (Class) G1 as defined by ISA-S71.04-1985
Table 7. Operating temperature de-rating specificationsIf the operating temerature of a system is up to 35 °C (95 °F), the maximum temperature is reduced by 1 °C/300 m (1 °F/547 ft) above 950 m (3,117 ft). If the operating temperature of a system ranges from 35 °C to 40 °C (95 °F to 104 °F), the maximum temperature is reduced by 1 °C/175 m (1 °F/319 ft) above 950 m (3,117 ft). If the operating temperature of a system ranges from 40 °C to 45 °C (104 °F to 113 °F), the maximum temperature is reduced by 1 °C/125 m (1 °F/228 ft) above 950 m (3,117 ft).
Operating temperature de-rating Specifications
Up to 35°C (95°F) Maximum temperature is reduced by 1°C/300 m (1°F/547 ft) above 950 m (3,117 ft).